Professional Documents
Culture Documents
Le Plasma Range Eng
Le Plasma Range Eng
VIBRATION
PERFORMANCE PC-210 MOTOR GENERATOR COMPATIBILITY:
Input
Comparison at 25A Motor generator
• minimum power 4kW
TEST compatibility • Vac peak voltage: below 410V.
180
• RMS voltage of the AC waveform:
160
230Vac ± 10%. Output
Travel speed (cm/min)
140
120 N E LEC
2
OL
100
TR
C
LIN
IC
Year warranty
80
N
PER
TIO
INTERNAL
Parts &
FO
EC
M Labour
OT
R
AN
CE PLUS PR
60 Unit Includes
DUST TEST
40 COMPRESSOR 2 m input cable with 16A plug
20 OR EXTERNAL Mounted 3 m hand cutting
0 torch
0 2 4 6 8 10 12 14 AIR Ground clamp and cable
Plate thickness (mm) Air connection kit
Cutting torch consumables kit
PC-210
DROP TEST external compressed air
SPECIFICATIONS
Item Primary Voltage Rated Cutting Inlet Output Weight Dimensions
Product Flow Rate
Number (50-60Hz) Output Capacity (mm) Pressure Range (A) (kg) HxWxD (mm)
25A/90V/35% 80l/min+/-
Invertec® PC210 K12038-1 230V/1Ph 20A/88V/60% 10 6,0 bar 10-25 18,5 385 x 215 x 480
20%@5,0bar
15A/86V/100%
3
OL
TR
C
LIN
250 250
IC
N E LEC
3
Year warranty OL
N
PER
TIO
TR
Parts &
C
FO
EC
LIN
M Labour
OT
Output
R
AN
IC
CE PLUS PR
Travel speed (cm/min)
N
PER
TIO
Parts &
FO
EC
M Labour
OT
R
AN
CE PLUS PR
150 150
100 100
Unit Includes
2 m-input cable 50 50
7,5 m-hand cutting torch
Ground clamp and cable 0 0
0 10 20 30 40 0 10 20 30 40 50
Air connection kit
Plate thickness (mm) Plate thickness (mm)
Cutting torch consumables kit
Aluminium Mild Stainless
SPECIFICATIONS
Item Primary Voltage Rated Cutting Piercing Capacity Inlet Output Weight Dimensions
Product Flow Rate
Number (50-60Hz) Output Capacity (mm) (mm)* Pressure Range (A) (kg) HxWxD (mm)
60A/40% 130l/min
Tomahawk® 1025 K12048-1 25 Max. 12 6,0 - 7,5 bar 20-60 22 389 x 247 x 489
40A/100% +/- 20%@5,0bar
400V/3Ph
100A/40% 280l/min
Tomahawk® 1538 K12039-1 40 Max. 20 6,0 - 7,5 bar 20-100 36 455 x 301 x 618
60A/100% +/- 20%@5,0bar
Undercarriage W0200002
Undercarriage K2694-1
PTM-061A-CX-7M5A
LC65M (Machine)
PTM-061A-CX-15A
PTH-101A-CX-7M5A
LC105 (Hand) CUTTING CIRCLES
PTH-101A-CX-15A (max diam. 820mm)
W0300699A
PTM-101A-CX-7M5A
LC105M (Machine)
PTM-101A-CX-15MA
er
Primary and secondary flow
ep
de
C
oncentrated plasma
m m
9,9
L
ong life electrodes and nozzles
Torch Connection –central connector, 9-pin
For connection equipment /torch the Tomahawk are provided by CENTRAL CONNECTOR
HIGHER TRAVEL
SPEED AND
LONGER LIFE TIME
CONSUMABLES
CONTACT STAND-OFF GOUGE
OPTION 1 OPTION 2 OPTION 3
Cooling
10/12 mm
LC 25 (Hand)
LC 25 Hand 3M PTH-C25A-SL-3MR
SHIELD CUP
GAS Part Quantity Reference
LC 25 ELECTRODE
DISTRIBUTOR
TIP BODY SPACER
Electrode 10 W03X0893-75A
Gas distributor 3 W03X0893-5R
Tip shielded - 25A 10 W03X0893-76A
W03X0893-75A W03X0893-5R W03X0893-76A Shield cap body 1 W03X0893-77A
(25A) W03X0893-77A W03X0893-78R Spacer 40 - 80A 3 W03X0893-78R
Air cooled
96 l/min@5,0 bar
25A@60%
10mm mild steel PLASMA-BOX LC25
12mm severance W03X0893-118A
CONTACT
RETAINING
LC 65 (Hand) CAP
W03X0893-26A
PTH-061A-CX-7M5A (40A)
LC 65 Hand 7,5M
(contact) SPACER Part Quantity Reference
LC 65 Hand 15M PTH-061A-CX-15MA
STAND OFF
25 W03X0893-25A
W03X0893-41A Electrode
3 W03X0893-53A
W03X0893-27A Gas distributor 2 W03X0893-50R
(40A) 10 W03X0893-29A
W03X0893-14R
W03X0893-28A
GAS 5 W03X0893-34A
LC 65 DISTRIBUTOR
(50A) Tip
ELECTRODE W03X0893-29A 3 W03X0893-39A
(60A) 3 W03X0893-54A
(stand off)
SHIELD CAP
Retaining cap 1 W03X0893-41A
SHIELDED
W03X0893-25A W03X0893-50R Shield cap body 1 W03X0893-43A
(contact, stand off, Spacer 1 W03X0893-14R
Air cooled shielded & gouging)
130 l/min@5,0 bar W03X0893-33A 1 W03X0893-44A
(50A) W03X0893-44A
60A@60% W03X0893-48A
25mm mild steel W03X0893-34A
Shield cap 1 PLASMA-BOX LC65
(60A)
SHIELD CUP 1 W03X0893-21A
30mm severance BODY W03X0893-113A
(shielded) O-ring 2 -
GOUGING
Silicone lubricant 1 -
for o-ring
EXTENDED
W03X0893-53A W03X0893-40A
(40A) W03X0893-21A
(extended)
W03X0893-54A
(60A)
(extended)
LC 65M (Machine)
SHIELD CUP
ELECTRODE GAS TIP BODY SHIELD CAP
LC 65M Machine 7,5M PTM-061A-CX-7M5A LC 65M DISTRIBUTOR
SHIELDED
LC 65M Machine 15M PTM-061A-CX-15MA
SHIELDED
20 W03X0893-60A
W03X0893-62A Electrode
(60A) 3 W03X0893-57A
ELECTRODE W03X0893-63A Gas distributor 2 W03X0893-70R
(80A) W03X0893-67A
W03X0893-64A 5 W03X0893-62A
(100A) SHIELD CUP
LC 105 W03X0893-60A
GAS BODY Tip
15 W03X0893-64A
DISTRIBUTOR (shielded)
GOUGING
5 W03X0893-65A
(shielded & gouging)
3 W03X0893-73A
Shield cap body 1 W03X0893-66A
W03X0893-70R W03X0893-65A W03X0893-66A W03X0893-69A 1 W03X0893-67A
Air cooled (gouging) Shield cap 1 W03X0893-69A
EXTENDED
280 l/min@5,5 bar 1 W03X0893-74A
100A@60% PLASMA-BOX LC105
O-ring 2 -
40mm mild steel W03X0893-115A
45mm severance W03X0893-57A
Silicone lubricant 1 -
W03X0893-58A for o-ring
(extended) (40A) W03X0893-74A
W03X0893-59A
(60A)
W03X0893-72A
(80A)
W03X0893-73A
LC 105M (Machine) (100A)
(extended)
SHIELDED
Tip 10 W03X0893-106A
20 W03X0893-107A
Shield cap body 1 W03X0893-112A
W03X0893-101A W03X0893-102A W03X0893-104A
(40-80A) (40A) W03X0893-66A W03X0893-110A 2 W03X0893-110A
Air cooled W03X0893-103A W03X0893-105A (40-80A) Shield cap
W03X0893-112A 2 W03X0893-111A
280 l/min@5,5 bar (100A) (60A) (OHMIC) W03X0893-111A
100A@60% W03X0893-106A (100A) O-ring 2 - PLASMA-BOX LC105M
40mm mild steel (80A) Silicone lubricant - W03X0893-117A
for o-ring 1
45mm severance W03X0893-107A
(100A)
LE-E2-20EN-M191
employees, however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information
or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or
any warranty of fitness for any customers’ particular purpose is specifically disclaimed.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results
obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.eu for any updated information.
www.lincolnelectriceurope.com