Download as pdf
Download as pdf
You are on page 1of 4
aaa calibration lab ‘st Floor, Office No. 2, Opp. Atika Railway Crossing, Near Rajshri Bajaj, Gondal Road, Rajkot - 360 002, Ph, 0281 - 2373109 Web : wwwgelr.co.in / Email : germancalibration@gmail.com CERTIFICATE OF CALIBRATION {ULR-£0206519000004414F Certificate No, Date of Calibration Due Date Tssue Date Page ‘o0004414/19 14/03/2019 13/03/2020 14/03/2019) Toft Customer Name: Jakap Metind Pvt. Lid. Plot No. 3864, Phase Il, Dared, Jamnagar +: 187, 130372019 Receipt No. / Date : 00307/19, 14/03/2019 Test item : Taper Thread Plug Gauge u Identity Number Make : Baker Serial Number : PKR-8673 Size : 1/8x27-NPTF-L1 Least Count : ‘As Received Condition : Ok Ret Standard No. : ANSI B1 20.5 1991 Environmental Condition : Temprature : 20°+2°C Relative Humidity : 50 + 10% Calibration Method : GCMI17 LabiiD : 0307/1915 Master Details & Traceability [Seno TT es Calibration Report No. | Valid Up To | ‘Universal Length Measuring Machine €GIL/2018/0727/C-001 26/07/2020 L Master Setting Ring -C LABICAO4/01/1756 28/05/2020 Uncertainty of Measurement : £3 um Calibration Result - Effective Pitch Diameter (All Reading are in mm) Specified Size | Wom Limit | Observed Size 9.4846 19.4945 9.4600 9.4850 / 9.4860 ‘The Uncertainty Stated is the expanded uncertainty of measurement obtained by multiplying the standard uncertainty by the coverage factor K=2 corresponds to confidence level of 95 % ‘This Certificate refers only tothe particular ten () submitted for Calibration. ‘The Calibration results reported inthis Certificate are valid tthe time of & under the stated condition of measurement ‘This Certificate Shall not be reproduced, except in ful unless writen permission from GCL “Due Date Suggested By Customer Catorated| ‘Technical Manager PRCHAVDA P.RCHAVDA, ceccns Rev.3.09/0072017 efrman calibration lab 1st Floor, Office No. 2, Opp. Railway Crossing, Near Rajshri Bajaj, Gondal Road, Rajkot - 360 002. Ph. 0281 - 2373109 Web : www.gelr.co.in / Email : germancalibration@gmail CERTIFICATE OF CALIBRATION viR.00706519000004415F Certificate No. Date of Calibration Due Date™ Tssue Date Page (00004415/19 14/03/2019 19/03/2020 14/03/2019 toft Customer Name: Jakap Metind Pvt. Ltd. Address: Plot No, 3864, Phase Il, Dared, Jamnagar Customer Reference : 187, 13/03/2019 Receipt No. / Date : 00307/19, 14/03/2019 Test item : Taper Thread Plug Gauge w Identity Number = Make : Baker ‘Serial Number : PHP-2806 Size : 1/8 x27 -NPTF-L3 [Least Count = ‘As Received Condition : Ok RefStandard No. : ANSI B1.20.5:1991 Environmental Condition : Temprature : 20°+2°C Relative Humidity : 50 + 10% Calibration Method : GCAWV/17 LabiID : 0307/1916 Master Details & Traceability A Calraion Report Ne. | Valid Up To ceiuzoreorz7-a01 2s)o72000 == “Csreaoaoirtrss 2a)osn000 Uncertainty of Measuroment = #3 um Calibration Result - Effective Pitch Diamator (Al Reading ar in mm) ww Gauge Plane Specified Size Worn Limit Observed Size sal End 2.0526 16.0627 20282 9.05887 8.0005 ‘he cata Sleds be enended neatly nearer ine by mihi te sandr weet Dye conrays ast? consonants eel of 6% This Catt ref ont parca om) sited er Clireon Te Calton ents oes eGo wv te ne ot unde ste canon ef mesure Tretia Marapr P.RCHAVDA German Calibration lab 4st Floor, Office No. 2, Opp. Atika Railway Crossing, Near Rajshri Bajai, Gondal Road, Rajkot - 360 002. Ph, 0281 - 2373109 4 Web : www.gelr.co.in / Email : germancalibration@gmail.com ' CERTIFICATE OF CALIBRATION Certificate No.__| Date of Calibration [Due Date * issue Date Page GCIJM/19/03/002 14.03.2019 14.03.2020 14.03.2019 | 1 of2 Customer Name : Jakap Metind Pvt.Ltd, ' Address : Plot No. 3864, Phase, Dared Customer Reference : 187,13,03.2019 Receipt Date. : 14.03.2019 ww ' Testitem : Taper Plug Gauge : Indentity Numer Make : BAKER Serial Number: 2H4902/a Range : 1/8-27 NPTF 6 STEP ‘As Received Condition : OK Ref. Standard. No. ANsi 81 205 Tethperature : 20° 2°C Relative Humidity: 40-60% Calibration Method: Gc/wi/os Master Details & Traceability @ ‘SN. [ Master Equipments | 1D No. Calibration Report No. Valid up to | ULM sc/uum/a | CGit/2018/0727/C-001 7/26/2820 Uncertainty of Measurment. : 25 um ‘The Uncertainty Stated is the expanded uncertainty of measurment obtained by multiplying the Standard uncertainty by the coverage factor K=2 corresponds to confidence level of 95 % ‘This cerficate refers only to the particular item(s) eubmited for calibration. ‘The Calioration results inthis cerficate are ald at the time of & under the stated condition of measurment. ' German Calibration lab 1st Floor, Office No. 2, Opp. Atika Railway Crossing, Near Rajst GGondal Road, Rajkot - 360 002. Ph, 0284 - 7373108 Email: germancalibration@gmail.com Web : www.gelr.co, CERTIFICATE OF CALIBRATION Certificate No. Date of Calibration | Due Date * issue Date__| Page GCiM19/03/002 | __14.03.2019 14.03.2020 14.03.2019 | _2of2 1 CALIBRATION RESULT : (All aro in mm) Parameter [Specified Value Observed Value : Basic Pipe Thvead Min Trzaon B 5.489915.5347 5.5290 Basic Pipe Thread Max Truston 8 6.873216.9240 6.9080! Mirman Teed Min Trvcaton WN 4.8565/4.9073 48890 Minimum Thread. Max Trncaten MNT | 6.2967/6.2459 6.2390 Maximum Teas Nin Tancation MX esiieeneed cn Maxi Thrend, Max uration MAT cece ee piraw aoe ce 8.4201/8.42301 8.4220 Feser on Obes 0.0620/0.0630 0.0825 Calibrated P.R.CHAVDA Technical Manager 0) ; ' P.RCHAVDA

You might also like