TRG 1-8 X 27 - NPTF

You might also like

Download as pdf
Download as pdf
You are on page 1of 4
ni calibration lab ‘Ist Floor, Office No. 2, Opp. Atika Railway Crossing, Near Rajshri Bajaj, Gondal Road, Rajkot - 360 002. Ph. 0281 - 2373109 Web : www.gclr.co.in / Email : germancalibration@gmail.com CERTIFICATE OF CALIBRATION {ULR-062065 19000005633 Certificate No. Date of Calibration ‘Due Date * issue Date Page (00005533/19 06/04/2019 ‘05/04/2020 06/04/2019 Toft ‘Customer Name : Jakap Metind Pvt. Ltd. ‘Address. : Plot No. 3864, Phase -Il, Dared, Jamnagar ‘Customer Reference : 000197, 01/04/2019 Receipt No. / Date : 00386/19, 03/04/2019 Nay Fa Test item : Taper Thread Ring Gauge L . Y Identity Number Make : Baker Serial Number: SYR-6022 Size : 1/8x27-NPTF-L1 Least Count = ‘As Received Condition : Ok Ref.Standard No. : ANS! B1.20.5:1991 Environmental Condition + Temprature : 20° + 2° C Relative Humidity : 50+ 10% Calibration Method : GO”WIN8 Labi : 0036/18/58 Master Details & Traceability Sr.No. Master Equipments 1D.No. Calibration Report No. 1 Universal Length Measuring Machine ccna caiuzoteo7z7ic-001 2 [Master Seting Ring -C Gomsric LABICAV0401/1756 Uncertainty of Measurement : £3 ym Calibration Result - Effective Pitch Diameter (All Reading are in mm) Specified Size | Worn Limit Observed Size 9.4046 19.4945 9.5188 9.4939 / 9.4944 es Gauge Plane ‘Small End “The Uncertainty Stated isthe expanded uncertainty of measurement obtained by multiplying the standard uncertainty by the coverage factor K=2 corresponds o confidence level of $5 % This Certificate refers only tothe particular item () submitted for Calibration ‘The Calibration results reported inthis Certificate are valid atthe me of & under the stated condition of measurement ‘This Certificate Shall not be reproduced, except in ful, unless written permission from GCL * Due Date Suggested By Customer Calibrated By Technical Manager PRCHAVDA P.RCHAVDA cewcn7 Rev.3.09002017 =e calibration lab 1st Floor, Office No. 2, Opp. Gondal Road, Rajkot - 360 002. Web : www.gelr.co.in / Email : germancalibration@gmai Railway Crossing, Near Rajshri Bajaj, h. 0281 - 2373109 Seem, CERTIFICATE OF CALIBRATION —inccoresionooosssor Carats Wo Dat of Calbraton Due Dae Toe Bate i ccobe88279 TaowzOT8 outa or Tot Ccuntomer Name + Jap Motnd Pri “addres, : Plt No, 3864, Phse I, Dared, Jamnager customer Reference : 000107, 070472019 Receipt No. Date : 008869, 03042018 Testitom + Teper Tread Fing Gauge v Kdeotip enter: Make : Baker Serial Number : SAT-2027 Sie 178427 -NPTE-L2 (aos: ‘As Received Condition : Ok Ref.Standard No. : ANSI B1.20.5 :1991 Environmental Condition : Temprature : 20°+2°C Relative Humidity : 50+ 10% Calibration Method : GCMW18 Labi : 00386/1957 Master Details & Traceability Seno. | te Eauipot Catan Reporto. | Valid Up To 1 Universal Length Measuring Machine ~ ©GIL/2018/0727/C-001 ‘26/07/2020 2._“MasterSeting Ring -C “LABICADAIOUA755 20/05/2020 Uncertainty of Measurement : £3 ym Effective Pitch Diameter (All Reading are in mm) ~ Observed Size 9.6529 / 9.6539 ‘The UnceiniyStsted fhe expanded uncertainty of measurement band by miipying the standard uncertainty bye overage factor K-2 coneaponds to confidence level of 95% “This Ceticat refers oni tothe patclar tem (submited for Caltaton. ‘The Calbraion resutsfopored nhs Create ve vad atthe tme of & under he sated condton of measurement “This Cericate Sha nt reproduced, exceptn il unless writen permission rom GCL "Due Date Suppested By Customer Caterated By “echnical Manager Ohnh. Oud PRRCHAVDA PRCHAVOA scree? Rev.3.09/002017 Erman 1 Uf Tela lola e-] os) 1st Floor, Office No. 2, Opp. Atika Railway Crossing, Near Rajshri Bajaj, Gondal Road, Rajkot - 360 002. Ph, 0281 - 2373109, Web : wwwgelrco.in / Email : germancalibration@gmail.com CERTIFICATE OF CALIBRATION Certificate No. Date of Calibration[ Due Date * issue Date Page GCHJM/19/04/009 02.04.2019 01.04.2020 02.04.2019 | 10f2 Customer Name : Jakap Metind Pvt. Ltd Address : Plot No.3686B&C,Phase II, Dared, Jamnagar Customer Reference : 197, 01.04.2019 Receipt Date. : 02.04.2019 Vv Test item : Taper Plain Ring Gauge Indentity Numer : ‘Make : Baker Serial Number: SAT 942 Range : 1/8-27 NPTF Crest Check Ring Gauge ‘As Received Condition : Ok Ref . Standard. No. ASME 1205 Temperature : 20°+2°C Relative Humidity: 40-60 % Calibration Method : GC/wi/os Master Details & Traceability \Y SN. | Master Equipments | ID No. Calibration Report No. Valid up to 1 ULM Gcfum/a | CGiL/2018/0727/¢-001 26/07/2020, Uncertainty of Measurment = 25 um ‘The Uncertainty Stated is the expanded uncertainty of measurment obtained by multiplying the Standard uncertainty by the coverage factor K=2 corresponds to confidence level of 95. % ‘This certficate refers ony tothe particular item(s) submited for calibration. ‘The Calibration results inthis cerificate are valid at the time of & under the stated condition of measurment. Erman calibration lab Ast Floor, Office No. 2, Opp. Atika Rallway Crossing, Near Rajshri Bajaj, Gondal Road, Rajkot - 360 002. Ph. 0281 - 2373109, Web : www.gelr.co.in / Email CERTIFICATE OF CALIBRATION Certificate No.__| Date of Calibration [Due Date * issue Date Page GC/JM/19/04/009 02.04.2019 01.04.2020 02.04.2019 2of2 CALIBRATION RESULT : (All are in mm) Parameter [Specified Value Observed Value Basic Thread Min Truction B 5..2629/5.3137 5.3100 Basic Thread Max Trucation BT 6.8523/6.7031 6.7000 ‘Minimum Thread . Min Trucation MN 5.8903/5.9411 5.9380 ‘Minimum Thread , Max Truncation MNT 7.2796/7.3304 7.3290 ‘Maximum Thread, Min Truncation MX 4.6355/4.6863 467 Maxie Thread , Max Truncation MT 6.0249/6.0757 6.0709 Major Diameter 10.28669/10.2895 10.2884 Taper On Diameter 0.0620/0.0630 0.0824 Calibrated By Technical Manager P.R.CHAVDA P.R.CHAVDA

You might also like