IMPULSE ENGINEERING CONSULTANTS

About us: A leading provider of MEP Design & Drafting services. We aim for client satisfaction,
value addition & customer service. Our work is completely process driven & result oriented. We
strive to continually improve & update our process and systems to stay in tune with the modern
technology.

----------------------------------------------------------------------------------------------------------

HVAC DESIGNING AND DRAFTING

INTRODUCTION:

( This field includes the details of the civil plan with location )
Total coverage of space for Air conditioning is ............ sq. mts. ( .......... sq. ft). Building
related data and cooling load estimation details are given in Table – I.

DESIGN PHILOSOPHY:

Primary objective of HVAC system design is to realize the end objectives of


(a) cost effectiveness
(b) energy conservation
(c) Fire safety
(d) Indoor air quality (IAQ)
(e) design flexibility providing ample scope for expansion / modifications
(f) Induction of new concepts / new technologies and
(g) ease of maintenance.

DESIGN STANDARDS:

The HVAC systems will be designed in accordance with the current edition of the following
Codes and Standards:

 American Society of Heating Refrigerating Air-conditioning Engineers (ASHRAE)


 Indian Society of Heating Refrigerating Air-conditioning Engineers (ISHRAE)
 National Fire Protection Association (NFPA)
 International Association of Plumbing and Mechanical Officials (IAPMO)

SOFTWARE HANDLING

 Hourly Analysis Program (HAP)


 ASHRAE Duct Fitting Database
 BETA Industrial LCC
 McQuay Duct sizer
 McQuay Pipe sizer
 AutoCAD 2013
 Manual Checking of Heat Load Calculation through E-20

SCHEMATIC DESIGN
IMPULSE ENGINEERING CONSULTANTS

CALCULATIONS:

No Space Floor Area Proposed TR


( Sq. Ft ) CFM ( Air flow )
1 Room 1

SALIENT FEATURES OF HVAC

o Total Estimated load : .................. TR


o Plant capacity proposed :
IMPULSE ENGINEERING CONSULTANTS
o Type of AC System : Chilled water

o Refrigeration Plant proposed : Reciprocating/Screw/Centrifugal


compressor with air cooled condensers
o No. of modules of main : ............ machines + one
refrigeration plant additional unit for redundancy
o Condensing system : Air cooled condensers
o Fresh air system : It is proposed to have centralized fresh
air system located on terrace.
o Air Filtration : By providing filters Type EU-2,
Filtration efficiency 90 % down to 20
microns
o Air Distribution System : By means of factory fabricated G. I.
Ducts both for supply and return. Supply
air duct internally insulated with thermal
insulation. Return air duct without
insulation.
o Winter Heating : By hot water generator with heating
coil for each AHU separately
o Fire safety provision : Fire dampers in supply and return air
duct. Heat/smoke detectors in return air.
Dampers & detectors integrated with
BIMS.
o Electric supply for HVAC :NDMC Mains supply as well as standby
supply by DG Sets.
o Monitoring & control of HVAC : Hook up with Building Integrated
Management System (BIMS)
IMPULSE ENGINEERING CONSULTANTS
Final Drawing:

Submitted by :