Low Riser: S.NO. Node No. Pipe Size (MM) Support Type

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 28

LOW RISER

S.NO. NODE NO. PIPE SIZE (mm) SUPPORT TYPE

1 50,010,905,001,090 150&200 (dia) TYPE-01

2 80,540,80,540, 80 (dia) TYPE-1A

3 220,810,220,810 200 &150 (dia) TYPE-02

4 23,402,790 80 (dia) TYPE-2A

5 40,630,40,630 150&200 (dia) TYPE-03


6 50,650 250300400450 (dia) TYPE-04

7 1460, 2020 250(dia) TYPE-05

8 1360, 1920 250(dia) TYPE-06


LOAD OBTAINED FROM CAESAR II
SUPPORT PHOTO
FX FY FZ Mx

0.67 0.5 0.67 0

0.5 0.5 0.5 0

0.5 16.7 0.5 0

1.8 13.27 0.5 0.5

0.5 80 0.5 0.5


5.1 2 0.5 0.5

0.5 25 0.5 0.5


ROM CAESAR II In this column, you have to provide what's the value
My Mz obtained from our staad calculation

0 0

0 0

0 0

0 1.37

0.5 0.5
0.5 0.5

0.5 0.5
In this column, please provide the allowable value
on which basis the software is saying that this
support is safe

ULTILTY RATIO = (Actual stress)/ (Allowable stress )


1 here the utlity ratio is 1 but the staad out put
utlity shown less than 1 so, the member is safe
MID RISER
S.NO. NODE NO. PIPE SIZE (mm) SUPPORT TYPE

80,540 , 80 ,540,80,540 , 80 ,
1 80, 100& 125 DIA TYPE-10
540

240,700,240,700,240,700,240,7
2 00, 100 &125 (DIA) TYPE-02

3 380 , 1430 200(DIA) TYPE-4A


4 450 ,1500 125 ,200 DIA TYPE-06

5 570 , 1670 150 DIA TYPE-09


LOAD OBTAINED FROM CAESAR II
SUPPORT PHOTO
FX FY FZ

0.5 3.6 0.5

0.5 14.5 0.5

0.5 9.5 0.5


1 84.5 0.5

0.5 14.8 0.5


OBTAINED FROM CAESAR II In this column, you have to provide what's the value
Mx My Mz obtained from our staad calculation

0 0 0

0.5 0.5 0.5

0 0 0
6.1 0.5 3.2

0.5 0.5 0.5


In this column, please provide the allowable value
on which basis the software is saying that this
support is safe

ULTILTY RATIO = (Actual stress)/ (Allowable stress )


1 here the utlity ratio is 1 but the staad out put
utlity shown less than 1 so, the member is safe
HIGH RISER
S.NO. NODE NO. PIPE SIZE (mm) SUPPORT TYPE

1 480 ,1460, 480 ,1460 80 ,100 ,125(DIA) TYPE-01

2 340, 1330,340, 1330, 200 &150 (DIA) TYPE-02

3 30, 1020, 30, 1020, 125,100 (DIA) TYPE-03


4 4040, 3000 80 ,100 &125 (DIA) TYPE-04

5 4110 , 3070 100 &125 DIA TYPE-05

6 3946 ,2950 ,3990 150(DIA) TYPE-07


7 3630 ,2600 150(DIA) TYPE-08

8 3900, 2870 150 DIA TYPE-09


LOAD OBTAINED FROM CAESAR II
SUPPORT PHOTO
FX FY FZ Mx

0.5 5 0.5 0

0.5 13.69 0.5 0.5

0.5 33.7 0.5 0.5


3 6.5 0.5 0.5

0.5 13.5 0.5 0.5

0.5 45.6 0.5 0.5


0.5 45.6 0.5 0.5

0.5 13.5 0.5 0.5


ROM CAESAR II In this column, you have to provide what's the value
My Mz obtained from our staad calculation

0 0

0.5 0.5

0.5 0
0.5 0.5

0.5 0.5

0.5 0.5
0.5 0.5

0.5 0.5
In this column, please provide the allowable value
on which basis the software is saying that this
support is safe

ULTILTY RATIO = (Actual stress)/ (Allowable stress )


1 here the utlity ratio is 1 but the staad out put
utlity shown less than 1 so, the member is safe

You might also like