Technical Glass Products Architectural Specification Manual

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 68

Technical Glass Products

Architectural Specification Manual

800.426.0279 | fireglass.com
FIREFRAMES® CURTAINWALL SERIES ARCHITECTURAL SPECIFICATION MANUAL

The Fireframes® Curtainwall Series frame system allows for large, multi-story expanses of fire-rated glass and
frames in both interior and exterior applications. Envision expansive window openings, with more glass and less
frame. Along with exterior applications, lobbies and atriums are well suited to the use of fire rated curtain wall
to provide uninterrupted views. Floor to ceiling fire-rated curtain walls can be used to divide interior spaces
while offering security and aesthetic appeal as well as fire protection. In addition, Fireframes® Curtainwall
Hurricane Series is available for hurricane applications. Fireframes Curtainwall is just one of the many
expressions of creativity that are changing traditional thinking about fire-rated glass and framing. The future of
fire safety has never looked so good.

For specifications, photographs and additional information contact:

Technical Glass Products


8107 Bracken Place SE
Snoqualmie, WA 98065

Office: 800.426.0279
425.396.8200
Fax: 425.396.8300
E-mail: sales@fireglass.com
Web: fireglass.com

© November 2019 Technical Glass Products. Pilkington Pyrostop is a registered trademark of Pilkington PLC. Technical Glass Products, Fireframes, Fireglass
and One Source. Many Solutions. are registered trademarks of Technical Glass Products. This information is intended for general reference only.

800.426.0279 | fireglass.com Architectural Specification Manual 2


R191121
Table of Contents

System Exploded Assembly ............................................................................................................................. 4


Material Key Chart ........................................................................................................................................... 5
General Information ........................................................................................................................................ 7
Features ....................................................................................................................................................................... 7
Testing Data ................................................................................................................................................................ 7
Curtainwall Hurricane Testing Data.........................................................................................................................8
Listings .........................................................................................................................................................................8
Sizing Guidelines ....................................................................................................................................................... 9
Americans with Disability Act Standards on Fire Protection Doors.................................................................... 9
Doors in Fireframes Curtainwall Series Frames................................................................................................... 10
Conventional Wood or Hollow Metal Doors in Fireframes Curtainwall Series Frames ................................. 10
Fire-Rated Glazing Options ..................................................................................................................................... 10
Glazing Specifications............................................................................................................................................... 11
Angle Segmented Frames ....................................................................................................................................... 14
Recommended Guidelines .............................................................................................................................. 15
45 mm System Profile Options ........................................................................................................................ 18
45 mm System Elevations ............................................................................................................................... 19
45 mm System Interior Section Details .......................................................................................................... 20
45 mm System Interior Section Details - Doors ...............................................................................................25
45 mm System Exterior Section Details .......................................................................................................... 29
45 mm System Exterior Section Details - Doors ...............................................................................................34
60 mm System Profile Options....................................................................................................................... 38
60 mm System Elevations .............................................................................................................................. 39
60 mm System Interior Section Details ........................................................................................................... 41
60 mm System Interior Section Details - Doors .............................................................................................. 46
60 mm System Exterior Section Details ......................................................................................................... 50
60 mm System Exterior Section Details - Doors ..............................................................................................55
60 mm System Exterior Section Details – Hurricane Application .................................................................... 59
Section Details - Doors................................................................................................................................... 65
Corner Details ................................................................................................................................................ 67

800.426.0279 | fireglass.com Architectural Specification Manual 3


R191121
System Exploded Assembly

11
5
17 14
3
8
18 16

26
22 6
27
26
23 9 4
27 25 15
28
29 8
31
16
11

13
19 12
11
11

30
12
18 17
1

20 21
24
10 3
30

26
27

Figure 1 - System Exploded Assembly View

800.426.0279 | fireglass.com Architectural Specification Manual 4


R191121
Material Key Chart
Item(s) Material Fasteners Provided With Fireframes Curtainwall Series
Connecting plate screws (Torx T25) for connecting “T” and “X” type connecting plates over
16 CONNECTING PLATE SCREW
mullion gasket intersections.
M6-1.0 x 16mm stainless steel flat head socket cap screws are provided for connecting bolt-
13 GLAZING PLATFORM SCREW
on glazing platforms to horizontal mullions.
Self-drilling screw (Torx T27) provided at appropriate length for connecting pressure plates
29 PRESSURE PLATE SCREW
and temporary pressure plates to mullions.
#12-11 stainless steel Phillips flat head sheet metal screws are provided for connecting
18 PERIMETER SPACER SCREW
perimeter spacers to mullions.
Non-welded sill anchors will have an M6-1.0 x 25mm screw securing the anchor to the
10 SILL ANCHOR SCREW
mullion.
Frames using sliding shear clips have an M6-1.0 x 30mm screw used to lock the shear clip into
4 SLIDING SHEAR CLIP SCREW
position once installed.
Item(s) Material Components Provided With Fireframes Curtainwall Series
Head and Sill anchors at vertical mullions are provided for jamb and intermediate mullion
1, 2, and 3 ANCHORS conditions. For Hurricane applications, anchors are available for concrete, steel, or timber
surrounding conditions.
Connecting plates, “T” and “X” styles, fit over freshly sealed mullion gasket joints at horizontal
14 and 15 CONNECTING PLATE
and vertical mullion intersections.
30 and 31 COVER CAP Snap on cover caps are provided for horizontal and vertical members.
Cover plates, similar to the connection plates, are used at the horizontal and vertical pressure
23 and 24 COVER PLATE
plate intersections and are applied to the exterior face of the glass under the pressure plates.
The diverter gasket may be integral to the horizontal mullion gasket, or it may be supplied as
22 DIVERTER GASKET
a separate gasket. See Fireframes project drawings for details.
FIRE-RATED GLAZING Refer to the Fire-Rated Glazing Options and Specifications, and Glazing Installation
20
MATERIAL Instructions.
On exterior applications, silicone linear flexible flashing and molded corner flashings may be
- FLEXIBLE FLASHING
provided.
A foam baffle (M2-045) is required at intermediate weeps (Section 15) on exterior elevations
- FOAM BAFFLE
over 20 feet (6m) tall.
12 GLAZING PLATFORM Bolt on glazing platforms are installed on sill and intermediate horizontals mullions.
Guide Bushings and Bushing Separators are provided to help guide the pressure plate screws
25 and 28 GUIDE BUSHING
and protect the glass during installation.
REQUIRED on all applications, fire-rated intumescent tape as supplied must be installed on
21 INTUMESCENT TAPE
the glass at each opening.
5, 6, and 8 MULLIONS Vertical and horizontal mullions are cut to size and pre-machined.
Black silicone gaskets for horizontal and vertical mullions may be shipped loose for field
11 MULLION GASKET
installation.
Spacers are made of hardwood, and are typically supplied in stock lengths not exceeding 96”
17 PERIMETER SPACER
for field trimming.
27 PRESSURE PLATE Pressure plate, gaskets, and guide bushings are provided.
26 PRESSURE PLATE GASKET EPDM seal required for pressure plate.
6 mm calcium silicate setting blocks shipped loose for field installation. Hardwood or silicone
19 SETTING BLOCKS
setting blocks are also allowable.
9 SHEAR CLIPS Sliding shear clips (or welded shear clips) are provided for each horizontal mullion.
- TEMPORARY PRESSURE PLATE A quantity of temporary pressure plates are provided to aid in the installation of the glass.
Figure 2 - Provided by TGP Material Key Chart

800.426.0279 | fireglass.com Architectural Specification Manual 5


R191121
Material Key Chart
Material Required Material NOT PROVIDED With Fireframes Curtainwall Series
If required per the approved Fireframes drawings, intermediate wind-load (dynamic) and/or dead load
ANCHORS (Special)
(fixed) anchors provided by other trades.
ANCHOR FASTENER As constructions vary widely in design, perimeter fasteners (anchors) are supplied by others.
Sealant installed into the interior and exterior perimeter cavity. Select color for sealant to match frame
FINISH SEALANT
or as directed by project architect.
REQUIRED on all applications, mineral wool and/or fire rated caulking must be installed between the
perimeter frame and surrounding conditions. Intumescent sealant or firmly packed mineral wool must be
FIRESAFING installed in a continuous fashion between frame assembly and wall construction, being interrupted only
by the perimeter anchor and/or anchor shims. Sealant manufacturers such as Tremco, Pemko and many
others supply intumescent sealants.
Perimeter shims at anchor locations are to be of hardwood (oak) or non-combustible (steel) materials.
SHIMS
Plastic shims may not be used.
When weeps or baffles are required at the sill condition of exterior applications, a 5/16” minimum inside
WEEPS AND BAFFLES diameter weep is recommended.
A 30 ppi reticulated foam baffle, compressed to 50% original size is recommended.
WALL CONDITION Rated wall construction by other trades.
Figure 3 - Not Provided by TGP Material Key Chart

800.426.0279 | fireglass.com Architectural Specification Manual 6


R191121
General Information
This document is meant as a general description of typical installations. As such, it is the responsibility of the
installer to ensure the frame materials are installed per the conditions that exist on any given project in
accordance with these instructions and project drawings. TGP project drawings may detail modifications to the
surrounding conditions required for a given project, (if architectural details or sketches were provided to TGP)
and should be used in conjunction with these instructions. In the event of any conflict between these
instructions and TGP project drawings, the TGP project drawings shall govern. TGP does not accept any warranty
and/or liability for installations not in compliance with this document or other non-conforming use of the TGP
products and/or system. Contact TGP with questions concerning these details as they apply to the particulars of
a given project.

FEATURES
• Fire ratings of 45, 60, 90, and 120 minutes.
• Unrestricted glazing area for use in locations where total glazing exceeds 25% of wall area (except for
45 minute rating).
• Full-lite doors available in single leaf or double leaf design (see Fireframes Designer Series or
Fireframes Heat Barrier Series).
• Narrow steel profiles.
• Air and water pressure tested and approved for exterior use.
• Easy installation; similar to typical pressure plate curtain wall.
• Frames supplied as “K.D.” (knock-down) for field installation.
• Pressure-glazed with EPDM or silicone gaskets.
• Can incorporate large individual panes of Pilkington Pyrostop® glass.
• Durable steel frames ensure low maintenance system.
• Custom cover caps (aluminum, stainless steel, etc.) to meet project needs.
• Factory finished to match desired color scheme.
• Fabricated in the U.S.A.
• Available for hurricane applications.

TESTING DATA

Test Type Per Standards Measured Results

CFM per square foot @ 1.57 PSF 0.1


Air Infiltration ASTM E283-91 Reported to the second decimal 0.07 Passed
TOTAL CFM 3.93
@ 30.00 PSF leakage after:
ASTM E547-00
Water Resistance 4 cycles of 5 minutes None Passed
ASTM E331-00
1 cycle of 15 minutes
Damage from a load of:
None
+125.00 PSF
None
Uniform Structural Load ASTM E330-97 -125.00 PSF Passed
0.005”
Permanent Set
0.317”
Deflection

800.426.0279 | fireglass.com Architectural Specification Manual 7


R191121
General Information
CURTAINWALL HURRICANE TESTING DATA

Test Type Per Standards Measured Results

Level of Protection ASTM E1996-09 Basic Protection None Passed

> 140 mph


Wind Zone ASTM E1996-09 Wind Zone 4 – Basic Wind Speed Passed
(63 m/s)
Damage From a Load of:
ASTM E1886-05
Design Pressure +110.00 PSF (+5267 Pa) No Damage Passed
TAS 202-94
-110.00 PSF (-5267 Pa)
0.063 cfm/ft2
Air Infiltration TAS 202-94 Tested at 6.24 PSF (299 Pa) Passed
(0.32 L/s*m2)
No Leakage at
Water Penetration
TAS 202-94 Tested at 16.5 PSF (790 Pa) 16.5 PSF Passed
Resistance Pressure
(790 Pa)
TAS 201-94 Damage From a Load of: No Openings
Impact Testing
ASTM E1886-05 +110.00 PSF (+5267 Pa) Greater Than Passed
(Large Missile)
ASTM E1996-09 -110.00 PSF (-5267 Pa) 130 mm x 1 mm
Anchors Fully
Damage From a Load of: Intact and No
Cyclic Wind Pressure TAS 203-94
+110.00 PSF (+5267 Pa) Openings Passed
Load Testing ASTM E1886-05
-110.00 PSF (-5267 Pa) Greater Than
130 mm x 1 mm
Standard Test Methods for
Measuring the Forced Entry
Forced Entry Test TAS 202-94 Resistance of Window No Damage Passed
Assemblies, Excluding Glazing
Impact

LISTINGS
• Listed and labeled by Underwriters Laboratories, Inc.® as Design Number U537 and Underwriters
Laboratories of Canada as W473.
• Frame tests performed in accordance with ASTM E-119 (60-120 minutes), NFPA 251, NFPA 257, UL
263, UL 9, UL 10C, ASTM E283, ASTM E330, ASTM E331, ASTM E547, AAMA 501.1, CAN/ULC-S101, and
CAN4 S-106.
• Approved for use in Los Angeles – LARR 25798.
• Fireframes Curtainwall Hurricane Series is approved under FL24474 and tests performed in accordance
with AAMA 501-05, ASTM E1886-05, ASTM E1996-09, ASTM E330, TAS 201-94, TAS 202-94, and TAS
203-94.

800.426.0279 | fireglass.com Architectural Specification Manual 8


R191121
General Information
SIZING GUIDELINES
Maximum Exposed Glass Maximum Exposed Glass
Frame Rating Maximum Frame Size
Area Per Piece Single Dimension
Maximum area:
152 sq. ft.
31.25 sq. ft. (22,888 sq.in.)
95-1/4”
45 Minutes * 4,500 sq. in. 14.12 sq. m.
2419 mm
2.9 sq. m. Maximum single dimension:
13’-6”
4,115 mm
39 sq. ft.
60 Minutes 96”
5,616 sq. in. n/a **
(Pyrostop 23 mm) 2,438 mm
3.62 sq. m.
Maximum width:
96”
51.7 sq. ft.
60 Minutes 2,438 mm
7442 sq. in. n/a **
(Pyrostop ≥ 26 mm) Maximum height:
4.8 sq. m.
118-1/8”
3,000 mm
25.9 sq. ft.
111”
120 Minutes 3,730 sq. in. n/a **
2,819 mm
2.41 sq. m.
Fireframes® Curtainwall Hurricane Series
39 sq. ft.
96”
60 Minutes 5,616 sq. in. n/a **
2,438 mm
39 sq. ft.
25.9 sq. ft.
96”
120 Minutes 3,730 sq. in. n/a **
2,438 mm
2.41 sq. m.

Sizing and Glazing Notes: Refer to the rows above.

* Opening Protective – Limited size IBC Fire Window Assembly Fire Protection Rating Table 715.4
** 60 and 120 minute tests conducted per UL 263 / ASTM E119. Therefore assembly is classified as a wall assembly, and
not subject to “opening” area limitations.

AMERICANS WITH DISABILITY ACT STANDARDS ON FIRE PROTECTION DOORS


If fire doors were required to meet A.D.A. (Americans with Disability Act) Standards, many would not open or
close with adequate force to prevent passage of flame and smoke. Recognizing this special fire safety need,
NFPA 101 (National Fire Protection Association) allows operational features for fire doors (opening forces,
closing speeds, etc.) that are different than for non-fire-rated doors. These fire “protective” steel doors carry
ratings from 20-90 minutes for fire protection. Heat transfer through the door is not an issue, so they are
constructed without interior insulation.

800.426.0279 | fireglass.com Architectural Specification Manual 9


R191121
General Information
DOORS IN FIREFRAMES CURTAINWALL SERIES FRAMES
Fireframes Designer Series and Fireframes Heat Barrier Series door frames and doors may be installed into the
Fireframes Curtainwall Series frames. For more details on installation, refer to those specific product’s
Architectural Specification Manuals.

CONVENTIONAL WOOD OR HOLLOW METAL DOORS IN FIREFRAMES CURTAINWALL SERIES FRAMES


Fireframes® Designer Series or Fireframes® Heat Barrier Series doors are compatible with Fireframes Curtainwall
Series framing. Additionally, conventional fire-rated wood or hollow metal doors can also be installed into
Fireframes Curtainwall Series frames, but will require coordination with respect to preparation of door
hardware. Prior to producing your shop drawings, TGP will need to evaluate relevant hardware schedule
information. When ordering wood or hollow metal doors, you must supply our engineering staff with the
manufacturer, model number, fabrication templates, door handing and, if required, physical samples. If TGP
must prepare special fabrication drawings to accommodate your hardware needs, your project lead time may be
extended.

FIRE-RATED GLAZING OPTIONS


Technical Glass Products provides a complete line of fire-rated glazing options to complement the Fireframes
Curtainwall Series frame system. Refer to your Technical Glass Products SpeciFIRE® Selection Guide, available
from your sales representative or online at www.fireglass.com.

Please consult your Technical Glass Products sales representative to determine the best option for your
application.
Complies with
Reduces Heat
Impact Safety

Energy Codes
Passes Hose
Stream Test

Compatible
Offers High

Available
with TGP

Provides
Acoustic
Transfer

Framing

Barrier
Glazing Advantages /
Fire Rating
Product Disadvantages
(minutes)

+ High clarity
Pilkington
45/60/120 ●* ● ● ● ● + Larger sizes
Pyrostop®
- Can be heavy

Pilkington + High clarity


Pyrostop® 45/60/120 ●* ● ● ● ● ● + Larger sizes
IGU - Can be heavy

Note: * Meets CPSC 16CFR1201: Category I and II.

800.426.0279 | fireglass.com Architectural Specification Manual 10


R191121
General Information
GLAZING SPECIFICATIONS
Pilkington Pyrostop® fire resistant glass provides up to a two (2) hour fire rating. It can also be combined with
other glazing products to achieve nearly any level of security protection and performance.

The Fireframes Curtainwall Series when combined with Pilkington Pyrostop at 60 minutes or greater, is classified
and listed with UL as a transparent wall; a fire resistive assembly that blocks the transfer of radiant heat during a
fire. Lower ratings (45 minute) are considered a window assembly.

45-260 60-261 120-262 120-203


Manufacturer’s
45-200 or 60-101 60-201 or 120-202 120-104 or or
Designation
*45-360 *60-361 *120-362 120-203 TI
Fire Rating
45 45 60 60 60 120 120 120 120
(minutes)

Glazing Type Single IGU Single Single IGU Single IGU IGU IGU

Interior Interior Interior Interior Interior Interior Interior


Application Interior Interior
Exterior Exterior Exterior Exterior Exterior Exterior Exterior

2-1/8”
54 mm
Nominal 3/4” 1-1/4” 7/8” 1-1/16” 1-5/8” 1-9/16” 2-1/8” 2-3/8”
or
Thickness 19 mm 33 mm 23 mm 27 mm 41 mm 40 mm 54 mm 61 mm
2-3/8”
60 mm
Weight -
Pounds per Sq. 9.22 12.49 10.85 12.90 15.77 19.46 21.71 22.12 24.99
Ft. (approx.)
Daylight 74%
Transmission 84% 75% 88% 88% 78% 85% 78% 75%
(approx.) 63% (TI)

STC Rating (dB)


40 40 41 44 44 46 46 46 44
(approx.)
UL-752 Bullet
Resistance Level I Level II
Rating
NOTES: ∗ Exterior IGU is available with Low E or Solar Control coating.
∆ Opening Protective – Limited size IBC Fire Window Assembly Fire Protection Rating Table 715.4
□ UL Listed as Wall Assembly as per UL 263 / ASTM E-119.

800.426.0279 | fireglass.com Architectural Specification Manual 11


R191121
General Information
Fireframes® Curtainwall Hurricane Series
60-260 60-260 TI 60-360 60-360 TI 120-260 120-360
Manufacturer’s Designation
HR Triple HR Triple HR Triple HR Triple HR Triple HR Triple

Fire Rating (minutes) 60 60 60 60 120 120

Glazing Type IGU IGU IGU IGU IGU IGU

Interior Interior Interior Interior Interior Interior


Application
Exterior Exterior Exterior Exterior Exterior Exterior

2-3/4” 2-3/4” 2-3/4” 2-3/4” 3-1/4” 3-1/4”


Nominal Thickness
69 mm 69 mm 69 mm 69 mm 82 mm 82 mm

Weight - Pounds per Sq. Ft. (approx.) 22.22 22.22 22.22 22.22 27.96 27.96

800.426.0279 | fireglass.com Architectural Specification Manual 12


R191121
General Information
GLAZING SPECIFICATIONS
60-101 – 60 Minute 60-201 – 60 Minute
Interior Window Exterior Window

7 " [23]

3 " [35.5]

11 2" [38]
1116" [27]
8

60-261 / 60-361 – 60 Minute 120-104 – 120 Minute


Exterior Window Interior Window

7 " [23]
1116" [27]

[66.5]
25 8"
[54]
21 8"
[53.5]
21 8"
[41]
15 8"

7 " [23]

16" [8]
1 " [6]

16" [8]

8
4

5
5

120-202 – 120 Minute 120-262 / 120-362 – 120 Minute


Exterior Window Exterior Window

19 16" [40]

[66.5]
25 8"
[54]
21 8"
2116" [52.5]
19 16" [40]

1 " [6]

16" [8]
4

45-200 – 45 Minute 45-260 / 45-360 – 45 Minute


Interior Window Exterior Window
3 " [19]

11 4" [31.5]

15 16" [33]

113 16" [45.5]


4

800.426.0279 | fireglass.com Architectural Specification Manual 13


R191121
General Information
Fireframes® Curtainwall Hurricane Series
60-260 HR Triple / 60-260 TI HR Triple – 60 Minute
120-260 HR Triple / 120-360 HR Triple – 120 Minute
60-360 HR Triple / 60-360 TI HR Triple – 60 Minute
Exterior Window
Exterior Window

1116" [27]

19 16"
[40]
33 16" [81.5]

33 4" [94.5]
21116" [69]

31 4" [82]
1 " [6]

16" [14]
16" [8]

16" [14]

16" [8]
1 " [6]

16" [14]

16" [14]
4

4
5

5
9
9

9
ANGLE SEGMENTED FRAMES
For interior and exterior applications utilizing the 60 mm wide profiles, the horizontals and glass can be angled
up to a maximum of six degrees (6°) on either side of the shared vertical mullion (Figures 4 and 5). This
configuration requires welded shear clips which have exposed fasteners on each side of the horizontal mullion.
Angle segmented frames are not allowed in Fireframes® Curtainwall Hurricane Series.

SEE DETAIL

SEG NT
ME
NT ME
SEG

SEGM ENT
ENT SEGM
SEGMENT
6° MAXIMUM ANGLE
Figure 4 - Segmented Frame Plan View

VERTICAL MULLION

HORIZONTAL MULLION
MULLION HORIZONTAL

GLASS GLASS

HORIZONTAL COVER CAP


COVER CAP HORIZONTAL

6° MAXIMUM ANGLE 6° MAXIMUM ANGLE


Figure 5 - Segmented Frame Detail

800.426.0279 | fireglass.com Architectural Specification Manual 14


R191121
Recommended Guidelines
1. REVIEW CONTRACT DOCUMENTS
Review architectural drawings, specifications, approved TGP project drawings, installation instructions, and shipping
lists to become thoroughly familiar with the project. The TGP project drawings take precedence and include specific
details for your installation. These installation instructions are of a general nature and cover most conditions.

2. BUILDING CODES
Due to the diversity in local, state / provincial, or federal laws and the codes that govern design and application of
architectural products, it is the responsibility of the individual architect / owner and installer to ensure that products
selected for use on projects comply with all the applicable building codes and laws. Technical Glass Products exercises
no control over the use or application of its products, glazing materials, and operating hardware and assumes no
responsibility thereof. Compliance of TGP project drawings with applicable codes for a given project shall be the
responsibility of the Buyer.

3. COORDINATION WITH OTHER TRADES


Coordinate with the general contractor any sequence with other trades which impact installation (i.e. fire proofing,
back-up walls, partitions, ceilings, mechanical ducts, converters etc.) or in which installation may impact the work of
adjacent trades.

4. INSTALLATION
All materials are to be installed plumb and level.

5. BENCH MARKS
All work should start from bench marks and/or column lines as established by the architectural drawings and the
general contractor with guaranteed accuracy. Using these datum points and lines, determine:
a. The plane of the wall in reference to offset lines provided on each floor;
b. The finish floor lines in reference to bench marks on the outer building columns; and
c. Mullion spacing from both ends of openings to prevent dimensional build-up of daylight opening.

6. SURROUNDING CONDITIONS
Unless specifically contracted to do so, TGP does not draw or detail the project specific surrounding conditions (the
area of the building that surrounds the TGP framing). Coordination of adjacent material and construction tolerances
to TGP’s systems must be facilitated by the installer. TGP recommends that a professional engineer review the project
drawings to verify the structural integrity of the installation. Please contact TGP if you would like a quote for fully
detailed project drawings including surrounding details and or Professional Engineering (PE) services.
a. Coordination of adjacent material and construction tolerances to TGP’s systems may be facilitated by TGP
as part of preparing project drawings, and these drawings may indicate acceptable tolerances for critical
dimensions. The installer should verify that surrounding construction is in accordance with the approved
project drawings. Do not accept rough opening dimensions less than shown on project drawings. It is
assumed that the minimal joint dimensions shown on the TGP project drawings match the field conditions.
A frame may fit within a given opening but sealants may not perform as detailed if a smaller sealant joint is
installed. Expansion / contraction issues may also be compromised. IF THE JOINTS ARE SMALLER THAN
THAT SHOWN ON THE TGP PROJECT DRAWINGS, DO NOT PROCEED. Notify the General Contractor that the
conditions are not as detailed and wait for corrective work to be completed before starting this work.

800.426.0279 | fireglass.com Architectural Specification Manual 15


R191121
Recommended Guidelines
b. The installer MUST notify and receive approval from TGP and the general contractor when conditions are
not in accordance with approved project drawings and/or change any aspect of the structural performance
of the Fireframes Series before making any modifications to the TGP-furnished material or making changes
which are different from those shown on the TGP project drawings. These conditions include, but are not
limited to, anchor placement/location, changes in adjacent materials the anchor is being connected to or
changes to dimensional relationships between framing, anchors and connection to adjacent materials.
c. TGP must review and approve in writing any changes required prior to the subcontractor installing any
“corrective” work. These reviews may incur additional charges, which must be approved by the TGP
customer prior to TGP’s review.

7. FRAME CONSTRUCTION VARIES


All frames are shipped “K-D” (knock-down) and are to be assembled on site. TGP does not pre-assemble frames prior
to shipment as the method for doing so is not intended for long shipping distances. Component parts such as anchors,
spacers, and gaskets are shipped loose. Depending on the installer’s preference, some of these components may be
pre-assembled at your shop prior to transporting to job site.

8. FASTENING
Within the body of these instructions, “fastening” means any method of securing one part to another or to adjacent
materials by means other than welding, adhering or using a mechanical fastener as shown on the approved details.
Only those fasteners used within the system are specified in these instructions. Due to the varying perimeter
conditions and performance requirements, perimeter and anchor fasteners are not specified in these instructions
and are the responsibility of the installer.

9. SEALANTS
a. Sealants must be compatible with all materials they are in contact with, including other sealant surfaces.
Consult with sealant manufacturer for recommendations relative to joint size, shelf life, compatibility,
cleaning/priming, tooling, adhesion, etc.
b. The chemical compatibility and/or adhesion of all glazing materials and framing sealants with each other
and with like materials used in glass and frame fabrication must be established by the installer. This is
required on every project.
c. If required by the project specifications, it is the responsibility of the glazing contractor to submit any
documentation or samples from the sealant manufacturer indicating that glass and glazing material has
been tested for chemical compatibility and/or adhesion with glazing sealants. This applies to all TGP
materials in contact with any sealant. TGP will furnish samples of these materials upon request.
d. The implementation of the test results is the responsibility of the installing contractor, and includes
material performance and recommendations for primers and substrate preparation required to obtain
adhesion.

10. PERIMETER JOINTS


Perimeter seals and/or expansion joints shown in these instructions and in the TGP project drawings are shown at
nominal size. Actual dimensions may vary due to perimeter conditions and/or difference in metal temperature
between the time of fabrication and the time of installation. Design and detailing have been based on a fabrication /
installation temperature of 70° F (21° C). If extreme temperatures exist at time of installation, gaps between
expansion members may require slight adjustment.

800.426.0279 | fireglass.com Architectural Specification Manual 16


R191121
Recommended Guidelines
11. CLAMPING SCREW TORQUE
Edge pressure must not exceed 11.5 pounds per linear inch. This pressure is required on the Fireframes Curtainwall
Series mullion gaskets. It must be uniformly applied by the exterior mounted pressure plate, through the glass, to the
mullion gaskets. Excessive or irregular edge pressure WILL CAUSE deformation and breakage.

12. WATER HOSE TEST


Exterior installations may require a water test in accordance with AAMA 501.2. As soon as a representative amount
of the wall has been glazed (500 square feet or 46.5 square meters) a water hose test should be conducted. This test
should be repeated for every 500 square feet (46.5 square meters), or as stipulated by specification, after all
components have been installed.

13. FIELD ANCHORS


Steel or stainless steel anchors that are welded to steel structure or are bolted to embed must be line set before
mullions are placed. Outstanding leg of anchors must be at 90° to offset lines. Mullion spacing should be held to
±1/32” (0.8 mm). Anchors may vary per job conditions. On stainless steel mullion projects, stainless steel anchors may
be used, therefore, proper welding procedures must be followed. Always refer to approved project drawings for
specific job site conditions.
a. AWS-certified welders are recommended to be used to install all field weld conditions called out in the TGP
project drawings. The responsibility of using experienced, certified welders is the installing contractor’s, not
TGP’s.
b. All field welding must be adequately shielded to avoid any splatter on glass or frame components. Results
of inadequately shielded field welding will be unsightly and /or structurally unsound. Advise general
contractor and other trades accordingly.
c. TGP typically finishes all steel material to protect from corrosion during shipping and storage on site prior to
installation. For powder coated finishes, it is required to grind off the finish at the expected weld location
prior to welding operations. The field weld must be re-finished with a zinc rich primer (in unexposed areas)
or with touch-up paint (in exposed areas) after the welding is completed. Welds should never be left
unpainted or unfinished. TGP can furnish small quantities of touch-up paint as required to match the
original finish.

14. STAINLESS STEEL


On projects with stainless steel mullions specified, certain precautions must be taken for proper installation.
a. When fastening any screw into the mullion, a constant torque tool such as a regular drill or screw gun must
be used. Impact style “bit-drivers” must NOT be used as the increased torque will likely break the screws.
b. If field drilling the mullions is required, sharp drill bits must be used with constant pressure maintained on
the drill bit at all times to avoid work-hardening the hole. Lubrication, such as a cutting fluid, is
recommended.
ATTENTION: Stainless steel fasteners used on this system need special care during installation. Loctite® brand
anti-seize must be used for all stainless steel fastener installation. If no lubrication is used, the fasteners have a
higher chance of galling and seizing during installation; this will either strip or break fasteners. If the fastener
seizes or strips, the fastener must be removed and replaced. Final fastener tightening should be done in
accordance with other sections as described herein.

800.426.0279 | fireglass.com Architectural Specification Manual 17


R191121
45 mm System Profile Options
45 mm MULLION PROFILE OPTIONS

13 4" [45] MULLION/TRANSOM PROFILE


· 18" [2.5] STEEL,
PRE-GALVANIZED
1815
* AVAILABLE IN 304 STAINLESS
STEEL WITH #4 BRUSH FINISH
1790
* SELF DRILLING FACADE SCREWS
1789 · CREATES SECURE FASTENING WITH
EXTREMELY HIGH PULLOUT VALUES
57 8" [148.5]

1788
*
53 8" [136.5]

WATER RESISTANT PENETRATION


· PREVENTS WATER INFILTRATION
41 2" [114]

1787
*
35 8" [91.5]

GLASS POCKET BUSHING


1 " [1.5]

· GUIDED DRILLING
21116"
[69]

SEAL
16

· ALIGNS EASILY IN PROFILE GROOVES


· OVERLAPPING JOINERY CREATES
SECURE FACADE SEAL

FACE OF HORIZONTAL COVER CAP


16" [7.5]

VARIES

1 " [3.5]

1 " [3]
8

1 " [12.8] (DLO)


2
5

8
REF: GLASS
DIMENSION

PRESSURE PLATE AND GASKET COVER CAP, PRESSURE PLATE AND GASKET

STAINLESS STEEL STAINLESS STEEL COVER CAPS ALUMINUM COVER CAPS


16" [13.5]

300381
3 " [18.5]

3 " [18.5]
3 " [10]

16" [15]
16" [15]

430050
8

411550
4

413630
9

9
9
7 " [21.5]

7 " [21.5]
11 " [18]

11 " [18]
16

16
8

411560 413640

113 16" [46]


16" [24.5]

16" [21]

413690
13
15

13 4" [45]

800.426.0279 | fireglass.com Architectural Specification Manual 18


R191121
45 mm System Elevations
1 16

8
23
IN-FILL PANEL OR
SPANDREL UNIT 4 19
BUILDING
SLAB OR 5
1 16 SUPPORT
20

8
23 11 26

14 15
29 30
2 17
2 17

6 9 6 9
21 24 21 24

CORNER DETAILS
3 18 7 22 3 18 7 22
77 78 79 80 81
WINDOW AND SINGLE DESIGNER SERIES DOOR WINDOW
A 45 MM SYSTEM B 45 MM SYSTEM

84" [2134] 84" [2134]


MAXIMUM DOOR OPENING MAXIMUM DOOR OPENING

10 25 10 25

12 12 13
27 74 27 76 28
MAXIMUM DOOR OPENING
MAXIMUM DOOR OPENING

75
96" [2438]
96" [2438]

ACTIVE / ACTIVE DESIGNER SERIES DOOR ACTIVE / FIXED DESIGNER SERIES DOOR
C 45 MM SYSTEM D 45 MM SYSTEM

800.426.0279 | fireglass.com Architectural Specification Manual 19


R191121
45 mm System Interior Section Details

CAULK
JOINT
ANCHOR BOLT
(BY OTHERS)
PERIMETER SPACER MINERAL WOOL (BY OTHERS)
PERIMETER SPACER SCREW SEALANT AND BACKER
ROD (BY OTHERS)
COVER CAP

300381
SLIDING SHEAR CLIP
ROUGH OPENING (RO)

13 4"
[45]

PRESSURE PLATE
CONNECTING PLATE 1/4" THICK HEAD ANCHOR
DIMENSION (FD)

300381
COVER PLATE BETWEEN
FRAME

GASKET AND GLASS


(DLO)

FIRE-RATED
GLASS

2 1116" - 5 7 8"
VARIES
[69.0 - 148.5]

HEAD SECTION
1 INTERIOR APPLICATION

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

SETTING BLOCK
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

PRESSURE PLATE SLIDING SHEAR CLIP

PRESSURE PLATE
300381

SCREW
13 4"
[45]

COVER CAP
300381

PRESSURE PLATE GASKET


INTUMESCENT TAPE
(DLO)

CONNECTING PLATE
MULLION GASKET
HORIZONTAL MULLION SECTION
2 INTERIOR APPLICATION

SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR


ATTACHED TO END OF
COVER PLATE BETWEEN
ROUGH OPENING (RO)

(DLO)
DIMENSION (FD)

VERTICAL MULLION
GASKET AND GLASS
FRAME

SLIDING SHEAR CLIP


PRESSURE PLATE
MINERAL WOOL (BY OTHERS)
CONNECTING PLATE
300381

FULL BEARING SHIM


13 4"
[45]

(BY OTHERS)
300381

SEALANT AND BACKER


ROD (BY OTHERS)
ANCHOR BOLT (BY OTHERS)
CAULK
JOINT

SILL SECTION
3 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 20


R191121
45 mm System Interior Section Details
FIRE-RATED GLASS
COVER PLATE BETWEEN
GASKET AND GLASS SLIDING SHEAR CLIP
(DLO)

SETTING BLOCK LINE OF


PRESSURE PLATE INTERIOR FINISH

PRESSURE PLATE

300381
SCREW
13 4"
[45]

COVER CAP

300381
PRESSURE PLATE GASKET
INTUMESCENT TAPE
(DLO)

CONNECTING PLATE
MULLION GASKET

BUILDING SLAB
OR SUPPORT
FACE OF VERTICAL COVER CAP
(DLO)

MULLION ANCHORS (SPECIAL)


PER PROJECT REQUIREMENTS
(TYP.)
(DLO)

SLIDING SHEAR CLIP


300381

LINE OF
13 4"
[45]

INTERIOR FINISH
300381
(DLO)

VARIES
HORIZONTAL MULLION SECTION WITH MULLION ANCHOR AT SLAB EDGE
4 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 21


R191121
45 mm System Interior Section Details

SLIDING PAD NOT PER BUILDING SLAB


PROJECT REQUIREMENTS OR SUPPORT
(BY OTHERS)

ANCHOR BOLTS
PER PROJECT

[69.0 - 148.5mm]
REQUIREMENTS

2 1116" - 5 7 8"
(BY OTHERS)

MULLION GASKET MULLION ANCHORS


(SPECIAL) PER PROJECT
FIRE-RATED GLASS REQUIREMENTS (BY OTHERS)

VARIES
FACE OF HORIZONTAL COVER CAP FACE OF HORIZONTAL COVER CAP

PRESSURE PLATE PRESSURE PLATE GASKET


SCREW
COVER CAP

(DLO) 13 4" (DLO)


[45]

VERTICAL MULLION SECTION AT SLAB


5 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 22


R191121
45 mm System Interior Section Details
1/4" THICK SILL ANCHOR 10GA WELDED SHEAR CLIP
SEALANT AND BACKER #10-24X1/2 UFHMS
ROD (BY OTHERS)
ANCHOR BOLT (BY OTHERS)
SILL ANCHOR SCREW

[69.0 - 148.5]
2 1116" - 5 7 8"
PERIMETER SPACER SCREW
MINERAL WOOL
(BY OTHERS)
SEALANT AND BACKER FIRE-RATED GLASS
ROD (BY OTHERS)

VARIES
PERIMETER SPACER
300381
300381

PRESSURE PLATE
GASKET
COVER CAP INTUMESCENT TAPE
PRESSURE PLATE
PRESSURE PLATE SCREW
13 4" (DLO)
[45]
CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH WELDED SHEAR CLIP AT SILL


6 INTERIOR APPLICATION

2 1116" - 5 7 8"
VARIES 1/4" THICK SILL ANCHOR
[69.0 - 148.5]
ATTACHED TO END OF
SILL ANCHOR SCREW VERTICAL MULLION
CONNECTING PLATE FIRE-RATED 10GA WELDED
GLASS SHEAR CLIP
FRAME DIMENSION (FD)

COVER PLATE BETWEEN


GASKET AND GLASS
ROUGH OPENING (RO)

#10-24X1/2 UFHMS
(DLO)

SETTING BLOCK ANCHOR BOLT


(BY OTHERS)
CAULK JOINT

PRESSURE PLATE
FULL BEARING SHIM
PRESSURE PLATE (BY OTHERS)
300381

SCREW
13 4"
[45]

SEALANT AND BACKER


COVER CAP ROD (BY OTHERS)
300381

PRESSURE PLATE GASKET ANCHOR BOLT


(BY OTHERS)
PERIMETER SPACER
MINERAL WOOL
(BY OTHERS)

SILL SECTION WITH WELDED SHEAR CLIP


7 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 23


R191121
45 mm System Interior Section Details
1/4" THICK SILL ANCHOR SLIDING SHEAR CLIP
SEALANT AND BACKER
ROD (BY OTHERS) ANCHOR BOLT
(BY OTHERS)

[69.0 - 148.5]
2 1116" - 5 7 8"
SILL ANCHOR SCREW
PERIMETER SPACER SCREW
MINERAL WOOL
(BY OTHERS)
FIRE-RATED GLASS
SEALANT AND BACKER
ROD (BY OTHERS)

VARIES
PERIMETER SPACER 300381
300381

PRESSURE PLATE
GASKET INTUMESCENT TAPE
COVER CAP PRESSURE PLATE
PRESSURE PLATE SCREW
13 4" (DLO)
[45]
CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)


JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL
8 INTERIOR APPLICATION

1/4" THICK SILL


ANCHOR [69.0 - 148.5]
2 1116" - 5 7 8"

ANCHOR BOLT (BY OTHERS)


SLIDING SHEAR CLIP

FIRE-RATED GLASS
VARIES

300381
300381

MULLION GASKET INTUMESCENT TAPE


PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP PRESSURE PLATE SCREW

(DLO) 13 4" (DLO)


[45]
FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION
9 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 24


R191121
45 mm System Interior Section Details - Doors

SEALANT AND BACKER ANCHOR BOLT MINERAL WOOL


ROD (BY OTHERS) (BY OTHERS) (BY OTHERS)
PERIMETER SPACER SLIDING SHEAR
CLIP
PERIMETER SPACER SCREW
1/4" THICK
COVER CAP

300381
CAULK JOINT

HEAD ANCHOR
PRESSURE PLATE
SCREW

300381
13 4" [45]

PRESSURE PLATE
14GA DOOR
ROUGH OPENING (RO)

ADAPTOR
FRAME DIMENSION (FD)
2116" [53]
DOOR OPENING (DO)

CLOSER
FACE OF VERTICAL COVER CAP

FACE OF VERTICAL COVER CAP


(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE

115 16" [50]

VARIES

GLAZING TAPE
PROVIDED ON 90 MIN.
RATED GLASS ONLY
(DLO)

SETTING BLOCK
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

SMOKE SEAL
16" [90]
39
1 " [13]
2

FINISHED FLOOR

HORIZONTAL MULLION, DOOR HEADER, AND BOTTOM RAIL


10 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 25


R191121
45 mm System Interior Section Details - Doors

FIRE-RATED
COVER PLATE BETWEEN GLASS
GASKET AND GLASS
CONNECTING PLATE
(DLO) SETTING BLOCK
SLIDING SHEAR
PRESSURE PLATE CLIP
COVER CAP

300381
13 4"
[45]

PRESSURE PLATE
SCREW
FRAME DIMENSION (FD)

300381
ROUGH OPENING (RO)

14GA DOOR
ADAPTOR
2116"
[53]
DOOR OPENING (DO)

CLOSER
(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE
(DLO)
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

FACE OF VERTICAL

FACE OF VERTICAL
COVER CAP

COVER CAP
39 16" [90]
(DLO)

GLAZING TAPE
PROVIDED ON 90 MIN.
RATED GLASS ONLY
SETTING BLOCK
(DLO)

SMOKE SEAL
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

39 16" [90]
1 " [13]
2

FINISHED FLOOR

DOOR HEADER WITH TRANSOM, DOOR MID RAIL, AND BOTTOM RAIL
11 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 26


R191121
45 mm System Interior Section Details - Doors
1/4" THICK ANCHOR ANCHOR BOLT (BY OTHERS)
SEALANT AND BACKER 14GA DOOR EXIT DEVICE
ROD (BY OTHERS) ADAPTOR
MINERAL WOOL (BY OTHERS)
PERIMETER SPACER SCREW
PERIMETER SPACER

115 16" [50]


PRESSURE PLATE
GASKET
COVER CAP 300381
300381

WELD ON
DOOR PIVOTS
PRESSURE PLATE GLAZING TAPE
PROVIDED FOR 90 MIN.
PRESSURE PLATE SCREW
GLASS ONLY
13 4" 2116" DOOR OPENING (DO)
[45] [53]
CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


12 INTERIOR APPLICATION

1/4" THICK ANCHOR


SEALANT AND BACKER
ROD (BY OTHERS)

MINERAL WOOL (BY OTHERS)

ANCHOR BOLT
14GA DOOR (BY OTHERS)
ADAPTOR
PERIMETER SPACER SCREW
PERIMETER SPACER
SEALANT AND BACKER
115 16"
[50]

ROD (BY OTHERS)


300381
300381
PRESSURE PLATE
GASKET
GLAZING TAPE PRESSURE PLATE
PROVIDED FOR 90 MIN.
GLASS ONLY PRESSURE PLATE SCREW
COVER CAP

DOOR OPENING (DO) 2116" 13 4" WELD ON


[53] [45] DOOR PIVOTS

FRAME DIMENSION (FD) CAULK JOINT

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


13 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 27


R191121
45 mm System Interior Section Details - Doors
SLIDING SHEAR CLIP 1/4" THICK ANCHOR EXIT DEVICE
PERIMETER SPACER
ANCHOR BOLT SCREW
(BY OTHERS)
[69.0 - 148.5]
2 1116" - 5 7 8"

14GA DOOR
ADAPTOR

115 16" [50]


VARIES

300381
300381

WELD ON
FIRE-RATED GLASS DOOR PIVOTS
INTUMESCENT TAPE COVER
PRESSURE PLATE
PRESSURE PLATE CAP
GASKET
PRESSURE PLATE SCREW
(DLO) 13 4" 2116" DOOR OPENING (DO)
[45] [53]
FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH SIDELITE DOOR JAMB AT PIVOT


14 INTERIOR APPLICATION

EXIT DEVICE 1/4" THICK ANCHOR SLIDING SHEAR CLIP


#12 S.S. FH
SCREW ANCHOR BOLT
(BY OTHERS)

[69.0 - 148.5]
2 1116" - 5 7 8"
14GA DOOR
ADAPTOR
115 16" [50]

VARIES

300381
300381

FIRE-RATED GLASS
INTUMESCENT TAPE
PRESSURE COVER PRESSURE PLATE
PLATE CAP
GASKET PRESSURE PLATE SCREW

DOOR OPENING (DO) 2116" 13 4" (DLO)


[53] [45]
FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH SIDELITE DOOR JAMB AT LEVER


15 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 28


R191121
45 mm System Exterior Section Details

CAULK
JOINT
ANCHOR BOLT
(BY OTHERS)
PERIMETER SPACER MINERAL WOOL (BY OTHERS)
PERIMETER SPACER SCREW SEALANT AND BACKER
ROD (BY OTHERS)
COVER CAP

300381
SLIDING SHEAR CLIP
ROUGH OPENING (RO)

13 4"
[45]

PRESSURE PLATE
CONNECTING PLATE 1/4" THICK HEAD ANCHOR
DIMENSION (FD)

300381
COVER PLATE BETWEEN
FRAME

GASKET AND GLASS


(DLO)

FIRE-RATED
GLASS

2 1116" - 5 7 8"
VARIES
[69.0 - 148.5]

HEAD SECTION
16 EXTERIOR APPLICATION

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

SETTING BLOCK
SLIDING SHEAR CLIP
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

PRESSURE PLATE

PRESSURE PLATE
300381

SCREW
13 4"
[45]

COVER CAP
300381

PRESSURE PLATE GASKET


DIVERTER GASKET
(DLO)

INTUMESCENT TAPE
CONNECTING PLATE
MULLION GASKET HORIZONTAL MULLION SECTION
17 EXTERIOR APPLICATION

SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR


ATTACHED TO END OF
COVER PLATE BETWEEN
ROUGH OPENING (RO)

(DLO)
DIMENSION (FD)

VERTICAL MULLION
GASKET AND GLASS
FRAME

SLIDING SHEAR CLIP


PRESSURE PLATE
MINERAL WOOL (BY OTHERS)
300381

FLEXIBLE SILICONE
FULL BEARING SHIM
13 4"
[45]

FLASHING SET IN
SEALANT BED (BY OTHERS)
300381

SEALANT AND BACKER


ROD (BY OTHERS)
ANCHOR BOLT
CAULK

(BY OTHERS)
JOINT

SILL SECTION
18 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 29


R191121
45 mm System Exterior Section Details
FIRE-RATED GLASS
COVER PLATE BETWEEN
GASKET AND GLASS SLIDING SHEAR CLIP
(DLO)

SETTING BLOCK LINE OF


PRESSURE PLATE INTERIOR FINISH

PRESSURE PLATE

300381
SCREW
13 4"
[45]

COVER CAP

300381
PRESSURE PLATE GASKET
DIVERTER GASKET
(DLO)

INTUMESCENT TAPE
CONNECTING PLATE
MULLION GASKET

BUILDING SLAB
OR SUPPORT
IN-FILL PANEL
OR SPANDREL UNIT
FACE OF VERTICAL COVER CAP
(DLO)

MULLION ANCHORS (SPECIAL)


PER PROJECT REQUIREMENTS
(TYP.)
(DLO)

SLIDING SHEAR CLIP


300381

LINE OF
13 4"
[45]

INTERIOR FINISH
300381
(DLO)

VARIES
HORIZONTAL MULLION SECTION WITH MULLION ANCHOR AT SLAB EDGE
19 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 30


R191121
45 mm System Exterior Section Details

SLIDING PAD NOT PER BUILDING SLAB


PROJECT REQUIREMENTS OR SUPPORT
(BY OTHERS)

ANCHOR BOLTS
PER PROJECT
REQUIREMENTS

[69.0 - 148.5]
2 1116" - 5 7 8"
FIRE-RATED GLASS.
SEE EXTERIOR GLAZING (BY OTHERS)
OPTIONS.
MULLION ANCHORS
(SPECIAL) PER PROJECT
REQUIREMENTS (BY OTHERS)

VARIES
FACE OF HORIZONTAL COVER CAP FACE OF HORIZONTAL COVER CAP

PRESSURE PLATE IN-FILL PANEL OR


SCREW SPANDREL UNIT
COVER CAP
13 4"
DLO DLO
[45]
VERTICAL MULLION SECTION AT SLAB
20 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 31


R191121
45 mm System Exterior Section Details
1/4" THICK SILL ANCHOR 10GA WELDED SHEAR CLIP
SEALANT AND BACKER #10-24X1/2 UFHMS
ROD (BY OTHERS)
ANCHOR BOLT (BY OTHERS)
SILL ANCHOR SCREW

[69.0 - 148.5]
2 1116" - 5 7 8"
PERIMETER SPACER SCREW
MINERAL WOOL
(BY OTHERS)
INTUMESCENT CAULK FIRE-RATED GLASS
(BY OTHERS)
FLEXIBLE SILICONE

VARIES
FLASHING SET IN
SEALANT BED 300381
300381

PERIMETER SPACER
PRESSURE PLATE INTUMESCENT TAPE
GASKET
PRESSURE PLATE
COVER CAP
PRESSURE PLATE SCREW
13 4" (DLO)
[45]
CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH WELDED SHEAR CLIP AT SILL


21 EXTERIOR APPLICATION

2 1116" - 5 7 8"
VARIES
[69.0 - 148.5]
SILL ANCHOR SCREW
FIRE-RATED 1/4" THICK SILL ANCHOR
CONNECTING PLATE GLASS ATTACHED TO END OF
VERTICAL MULLION
FRAME DIMENSION (FD)

COVER PLATE BETWEEN


GASKET AND GLASS
ROUGH OPENING (RO)

(DLO)

10GA WELDED
SETTING BLOCK SHEAR CLIP

PRESSURE PLATE #10-24X1/2 UFHMS


CAULK JOINT

FULL BEARING SHIM


SELF-DRILING S.S. (BY OTHERS)
300381

FACADE SCREW @ 12" O.C.


13 4"
[45]

MINERAL WOOL (BY OTHERS)


COVER CAP
300381

SEALANT AND BACKER


PERIMETER SPACER ROD (BY OTHERS)
PRESSURE PLATE GASKET ANCHOR BOLT
FLEXIBLE SILICONE FLASHING (BY OTHERS)
SET IN SEALANT BED
INTUMESCENT CAULK
(BY OTHERS)
SILL SECTION WITH WELDED SHEAR CLIP
22 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 32


R191121
45 mm System Exterior Section Details
1/4" THICK SILL ANCHOR
SEALANT AND BACKER SLIDING SHEAR CLIP
ROD (BY OTHERS)
ANCHOR BOLT
SILL ANCHOR SCREW (BY OTHERS)

MULL. DIM.
35 8" [91.5]
PERIMETER SPACER SCREW
MINERAL WOOL (BY OTHERS)
INTUMESCENT
CAULK (BY OTHERS)
FLEXIBLE SILICONE
FLASHING SET IN

VARIES
SEALANT BED
PERIMETER SPACER 300381
300381

PRESSURE PLATE
GASKET INTUMESCENT TAPE
COVER CAP PRESSURE PLATE
PRESSURE PLATE SCREW
13 4" (DLO)
[45]
CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL


23 EXTERIOR APPLICATION

1/4" THICK SILL


ANCHOR
[69.0 - 148.5]
2 1116" - 5 7 8"
ANCHOR BOLT (BY OTHERS)
SLIDING SHEAR CLIP

FIRE-RATED GLASS
VARIES

300381
300381

MULLION GASKET INTUMESCENT TAPE


PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP PRESSURE PLATE SCREW

(DLO) 13 4" (DLO)


[45]
FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION
24 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 33


R191121
45 mm System Exterior Section Details - Doors

INTUMESCENT CAULK (BY OTHERS) ANCHOR BOLT MINERAL WOOL


(BY OTHERS) (BY OTHERS)
SEALANT AND BACKER
ROD (BY OTHERS) SLIDING SHEAR
CLIP
PERIMETER SPACER
1/4" THICK
PERIMETER SPACER SCREW
HEAD ANCHOR
COVER CAP
CAULK JOINT

300381
PRESSURE PLATE
SCREW
13 4" [45]

300381
PRESSURE PLATE
14GA DOOR
ROUGH OPENING (RO)

ADAPTOR
FRAME DIMENSION (FD)
2116" [53]
DOOR OPENING (DO)

CLOSER
FACE OF VERTICAL COVER CAP

FACE OF VERTICAL COVER CAP


(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE

115 16" [50]

VARIES

GLAZING TAPE
PROVIDED ON 90 MIN.
RATED GLASS ONLY
(DLO)

SETTING BLOCK
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

SMOKE SEAL
16" [90]
39
1 " [13]
2

FINISHED FLOOR

HORIZONTAL MULLION, DOOR HEADER, AND BOTTOM RAIL


25 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 34


R191121
45 mm System Exterior Section Details - Doors
COVER PLATE BETWEEN FIRE-RATED
GASKET AND GLASS GLASS
(DLO)
SETTING BLOCK CONNECTING PLATE
PRESSURE PLATE SLIDING SHEAR
CLIP
COVER CAP

300381
13 4"
[45]

PRESSURE PLATE
SCREW
FRAME DIMENSION (FD)

300381
ROUGH OPENING (RO)

14GA DOOR
ADAPTOR
2116"
[53]
DOOR OPENING (DO)

CLOSER
(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE
(DLO)
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

FACE OF VERTICAL

FACE OF VERTICAL
COVER CAP

COVER CAP
39 16" [90]
(DLO)

GLAZING TAPE
PROVIDED ON 90 MIN.
RATED GLASS ONLY
SETTING BLOCK
(DLO)

SMOKE SEAL
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

39 16" [90]
1 " [13]
2

FINISHED FLOOR

DOOR HEADER WITH TRANSOM, DOOR MID RAIL, AND BOTTOM RAIL
26 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 35


R191121
45 mm System Exterior Section Details - Doors
1/4" THICK ANCHOR
SEALANT AND BACKER ANCHOR BOLT (BY
ROD (BY OTHERS) OTHERS)
EXIT DEVICE
MINERAL WOOL (BY OTHERS) 14GA DOOR
ADAPTOR
PERIMETER SPACER SCREW
INTUMESCENT
CAULK (BY OTHERS)
FLEXIBLE SILICONE

115 16" [50]


FLASHING SET IN
SEALANT BED
SEALANT AND BACKER 300381
300381

ROD (BY OTHERS)


PERIMETER SPACER WELD ON
DOOR PIVOTS
PRESSURE PLATE
GLAZING TAPE
GASKET PRESSURE PLATE
PROVIDED FOR 90 MIN.
COVER CAP PRESSURE PLATE SCREW GLASS ONLY
13 4" 2116" (DO)
[45] [53]
CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


27 EXTERIOR APPLICATION

1/4" THICK ANCHOR


SEALANT AND BACKER
ROD (BY OTHERS)
MINERAL WOOL (BY OTHERS)
ANCHOR BOLT (BY OTHERS) PERIMETER SPACER SCREW
14GA DOOR INTUMESCENT
ADAPTOR CAULK (BY OTHERS)
FLEXIBLE SILICONE
FLASHING SET IN
115 16"
[50]

SEALANT BED

300381
300381
PERIMETER SPACER
SEALANT AND BACKER
ROD (BY OTHERS)
GLAZING TAPE WELD ON
PROVIDED FOR 90 MIN. DOOR PIVOTS PRESSURE PLATE
GLASS ONLY GASKET
PRESSURE
PLATE PRESSURE PLATE SCREW
DOOR OPENING (DO) 2116" 13 4"
COVER CAP
[53] [45]
FRAME DIMENSION (FD) CAULK JOINT

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


28 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 36


R191121
45 mm System Exterior Section Details - Doors
SLIDING SHEAR CLIP 1/4" THICK ANCHOR EXIT DEVICE

ANCHOR BOLT 14GA DOOR


(BY OTHERS) ADAPTOR
[69.0 - 148.5]
2 1116" - 5 7 8"

PERIMETER
SPACER
SCREW

115 16" [50]


VARIES

300381
300381

FIRE-RATED GLASS
INTUMESCENT TAPE COVER PRESSURE WELD ON GLAZING TAPE
PRESSURE PLATE CAP PLATE DOOR PIVOTS PROVIDED FOR 90 MIN.
GASKET GLASS ONLY
PRESSURE PLATE SCREW
(DLO) 13 4" 2116" DOOR OPENING (DO)
[45] [53]
FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH SIDELITE DOOR JAMB AT PIVOT


29 EXTERIOR APPLICATION

EXIT DEVICE 1/4" THICK ANCHOR SLIDING SHEAR CLIP


PERIMETER SPACER ANCHOR BOLT
SCREW (BY OTHERS)

[69.0 - 148.5]
2 1116" - 5 7 8"
14GA DOOR
ADAPTOR
115 16" [50]

VARIES

300381
300381

PRESSURE
PLATE FIRE-RATED GLASS
GASKET INTUMESCENT TAPE
COVER PRESSURE PLATE
CAP
PRESSURE PLATE SCREW
(DO) 2116" 13 4" (DLO)
[53] [45]
FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH SIDELITE DOOR JAMB AT LEVER


30 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 37


R191121
60 mm System Profile Options
60 mm MULLION PROFILE OPTIONS

23 8" [60]

MULLION/TRANSOM PROFILE
· 18" [2.5] STEEL,
1806
* PRE-GALVANIZED
* AVAILABLE IN 304 STAINLESS
STEEL WITH #4 BRUSH FINISH
1804
* SELF DRILLING FACADE SCREWS
· CREATES SECURE FASTENING WITH
EXTREMELY HIGH PULLOUT VALUES
71 8" [181.5]

WATER RESISTANT PENETRATION


1802
*
53 8" [136.5]

· PREVENTS WATER INFILTRATION


35 8" [91.5]

GLASS POCKET BUSHING


· GUIDED DRILLING
1 " [1.5]
16

SEAL
· ALIGNS EASILY IN PROFILE GROOVES
· OVERLAPPING JOINERY CREATES
SECURE FACADE SEAL

FACE OF HORIZONTAL COVER CAP


16" [7.5]

1 " [3.5]
VARIES

1 " [3]
8

13 (DLO)
16" [20]
5

8
REF: GLASS
DIMENSION

PRESSURE PLATE AND GASKET COVER CAP, PRESSURE PLATE AND GASKET

STAINLESS STEEL STAINLESS STEEL COVER CAPS ALUMINUM COVER CAPS


16" [13.5]

16" [24.5]
16" [24.5]

3 " [18.5]
3 " [10]

300381
16" [15]
16" [21]

16" [21]
430060
8

413510
9

430530 413530
13

13
15
15

7 " [21.5]
1116" [27.5]

1116" [27.5]
11 " [18]
16" [24]

16" [24]
16
8

413520
15

15

430540 413540

23 8" [61] 23 8" [60] 23 8" [60]

800.426.0279 | fireglass.com Architectural Specification Manual 38


R191121
60 mm System Elevations
31 46

38
53
IN-FILL PANEL OR
SPANDREL UNIT 34 49
BUILDING
SLAB OR 35
31 46 SUPPORT
50

38
53 41 56

44 45
59 60
32 47
32 47

36 39 36 39
51 54 51 54

CORNER DETAILS
33 48 37 52 33 48 37 52
77 78 79 80 81
WINDOW AND SINGLE DESIGNER SERIES DOOR WINDOW
E 60 MM SYSTEM F 60 MM SYSTEM

84" [2134] 84" [2134]


MAXIMUM DOOR OPENING MAXIMUM DOOR OPENING

40 55 40 55

42 42 43
57 74 57 76 58
MAXIMUM DOOR OPENING

MAXIMUM DOOR OPENING

75
96" [2438]

96" [2438]

ACTIVE / ACTIVE DESIGNER SERIES DOOR ACTIVE / FIXED DESIGNER SERIES DOOR
G 60 MM SYSTEM H 60 MM SYSTEM

800.426.0279 | fireglass.com Architectural Specification Manual 39


R191121
60 mm System Elevations
Hurricane Application

61 66 70

64 65
68 69
72 73

62

63 67 71
CURTAINWALL HURRICANE WINDOW
I 60 MM SYSTEM

800.426.0279 | fireglass.com Architectural Specification Manual 40


R191121
60 mm System Interior Section Details
CAULK
JOINT
PERIMETER SPACER ANCHOR BOLT MINERAL WOOL (BY OTHERS)
(BY OTHERS)
SEALANT AND BACKER
PERIMETER SPACER SCREW ROD (BY OTHERS)
COVER CAP SLIDING SHEAR CLIP

300381
ROUGH OPENING (RO)

23 8" [60]

PRESSURE PLATE 1/4" THICK HEAD ANCHOR


DIMENSION (FD)

CONNECTING PLATE
FRAME

300381
COVER PLATE BETWEEN
GASKET AND GLASS
(DLO)

FIRE-RATED GLASS

3 5 8" - 7 1 8"
VARIES
[91.5 - 181.5]

HEAD SECTION
31 INTERIOR APPLICATION

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

SETTING BLOCK
SLIDING SHEAR CLIP
PRESSURE PLATE
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

PRESSURE PLATE
300381
23 8" [60]

SCREW
COVER CAP
PRESSURE PLATE GASKET
300381

INTUMESCENT TAPE
(DLO)

CONNECTING PLATE
MULLION GASKET

HORIZONTAL MULLION SECTION


32 INTERIOR APPLICATION

SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR


ATTACHED TO END OF
COVER PLATE BETWEEN
VERTICAL MULLION
(DLO)

GASKET AND GLASS


ROUGH OPENING (RO)

DIMENSION (FD)

SLIDING SHEAR CLIP


PRESSURE PLATE
FRAME

MINERAL WOOL (BY OTHERS)


CONNECTING PLATE
300381

FULL BEARING SHIM


23 8" [60]

(BY OTHERS)
SEALANT AND BACKER
300381

ROD (BY OTHERS)


ANCHOR BOLT (BY
OTHERS)
CAULK
JOINT

SILL SECTION
33 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 41


R191121
60 mm System Interior Section Details
FIRE-RATED GLASS
COVER PLATE BETWEEN
GASKET AND GLASS SLIDING SHEAR CLIP
(DLO)

SETTING BLOCK LINE OF


INTERIOR FINISH
PRESSURE PLATE
PRESSURE PLATE

300381
SCREW
23 8" [60]

COVER CAP
PRESSURE PLATE GASKET
INTUMESCENT TAPE 300381
(DLO)

CONNECTING PLATE
MULLION GASKET

BUILDING SLAB
OR SUPPORT
FACE OF VERTICAL COVER CAP
(DLO)

MULLION ANCHORS
(SPECIAL) PER PROJECT
REQUIREMENTS
(TYP.)
(DLO)

300381
23 8" [60]

SLIDING SHEAR CLIP


LINE OF
INTERIOR FINISH
300381
(DLO)

VARIES

HORIZONTAL MULLION SECTION WITH MULLION ANCHOR AT SLAB EDGE


34 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 42


R191121
60 mm System Interior Section Details

SLIDING PAD NOT PER BUILDING SLAB


PROJECT REQUIREMENTS OR SUPPORT
(BY OTHERS)

ANCHOR BOLTS
PER PROJECT
REQUIREMENTS

[91.5 - 181.5]
3 5 8" - 7 1 8"
(BY OTHERS)

MULLION GASKET MULLION ANCHORS


(SPECIAL) PER PROJECT
FIRE-RATED GLASS
REQUIREMENTS (BY OTHERS)

VARIES
FACE OF HORIZONTAL COVER CAP FACE OF HORIZONTAL COVER CAP

PRESSURE PLATE PRESSURE PLATE GASKET


SCREW
COVER CAP

(DLO) 23 8" [60] (DLO)

VERTICAL MULLION SECTION AT SLAB


35 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 43


R191121
60 mm System Interior Section Details
10GA WELDED SHEAR CLIP
#10-24X1/2 UFHMS

ANCHOR BOLT (BY OTHERS)


SEALANT AND BACKER
ROD (BY OTHERS)
1/4" THICK ANCHOR

[91.5 - 181.5]
3 5 8" - 7 1 8"
SILL ANCHOR SCREW
PERIMETER SPACER SCREW
MINERAL WOOL
(BY OTHERS)
PERIMETER SPACER FIRE-RATED GLASS
PRESSURE PLATE
GASKET

VARIES
COVER CAP
300381
300381

INTUMESCENT TAPE
PRESSURE PLATE
PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSIONS (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH WELDED SHEAR CLIP AT SILL


36 INTERIOR APPLICATION

3 5 8" - 7 1 8"
VARIES
[91.5 - 181.5]
SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR
ATTACHED TO END OF
FIRE-RATED GLASS
VERTICAL MULLION
FRAME DIMENSION (FD)

(DLO)

CONNECTING PLATE
ROUGH OPENING (RO)

#10-24X1/2 UFHMS
COVER PLATE BETWEEN
GASKET AND GLASS 10GA WELDED
SHEAR CLIP
SETTING BLOCK
ANCHOR BOLT (BY OTHERS)
PRESSURE PLATE
300381
CAULK JOINT

FULL BEARING SHIM


23 8" [60]

PRESSURE PLATE SCREW (BY OTHERS)


COVER CAP SEALANT AND BACKER
PRESSURE PLATE GASKET ROD (BY OTHERS)
300381

PERIMETER SPACER
MINERAL WOOL
(BY OTHERS)

SILL SECTION WITH WELDED SHEAR CLIP


37 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 44


R191121
60 mm System Interior Section Details
1/4" THICK SILL ANCHOR SLIDING SHEAR CLIP
SEALANT AND BACKER
ROD (BY OTHERS) ANCHOR BOLT
(BY OTHERS)
SILL ANCHOR SCREW
PERIMETER SPACER SCREW

[91.5 - 181.5]
3 5 8" - 7 1 8 "
MINERAL WOOL
(BY OTHERS)
PERIMETER SPACER
SEALANT AND BACKER
ROD (BY OTHERS)
FIRE-RATED GLASS
PRESSURE PLATE
GASKET

VARIES
COVER CAP
300381
300381

INTUMESCENT TAPE
PRESSURE PLATE
PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)


JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL
38 INTERIOR APPLICATION

1/4" THICK SILL


ANCHOR
ANCHOR BOLT
[91.5 - 181.5]
3 5 8" - 7 1 8"

(BY OTHERS)
SLIDING SHEAR CLIP
FIRE-RATED GLASS
VARIES

300381
300381

MULLION GASKET INTUMESCENT TAPE


PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP PRESSURE PLATE
SCREW

(DLO) 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION
39 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 45


R191121
60 mm System Interior Section Details - Doors

SEALANT AND BACKER ANCHOR BOLT MINERAL WOOL


ROD (BY OTHERS) (BY OTHERS) (BY OTHERS)
PERIMETER SPACER SLIDING SHEAR
CLIP
PERIMETER SPACER SCREW
COVER CAP 1/4" THICK

300381
CAULK JOINT

HEAD ANCHOR
23 8" [60]

PRESSURE PLATE
SCREW
PRESSURE PLATE

300381
14GA DOOR
2116" [53]
ROUGH OPENING (RO)

ADAPTOR
FRAME DIMENSION (FD)

DOOR OPENING (DO)

CLOSER
FACE OF VERTICAL COVER CAP

FACE OF VERTICAL COVER CAP


(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE

115 16" [50]

VARIES

DOOR FIRE RATED


GLASS
GLAZING TAPE
PROVIDED ON 90 MIN.
(DLO)

RATED GLASS ONLY


FRAME DIMENSION (FD)
ROUGH OPENING (RO)

SETTING BLOCK
DOOR OPENING (DO)

SMOKE SEAL
39 16" [90]
1 " [13]
2

FINISHED FLOOR

HORIZONTAL MULLION, DOOR HEADER, AND BOTTOM RAIL


40 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 46


R191121
60 mm System Interior Section Details - Doors
COVER PLATE BETWEEN FIRE-RATED GLASS
GASKET AND GLASS
CONNECTING PLATE
(DLO) SETTING BLOCK
SLIDING SHEAR
PRESSURE PLATE CLIP

300381
COVER CAP
23 8" [60]

PRESSURE PLATE
SCREW
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

300381
14GA DOOR
2116" [53]

ADAPTOR
DOOR OPENING (DO)

CLOSER
(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE
(DLO)
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

FACE OF VERTICAL

FACE OF VERTICAL
COVER CAP

COVER CAP
39 16" [90]
(DLO)

GLAZING TAPE
PROVIDED ON 90 MIN.
RATED GLASS ONLY
SETTING BLOCK
(DLO)

SMOKE SEAL
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

39 16" [90]
1 " [13]
2

FINISHED FLOOR

DOOR HEADER WITH TRANSOM, DOOR MID RAIL, AND BOTTOM RAIL
41 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 47


R191121
60 mm System Interior Section Details - Doors
1/4" THICK ANCHOR ANCHOR BOLT
(BY OTHERS)
SEALANT AND BACKER
ROD (BY OTHERS) 14GA DOOR
ADAPTOR EXIT DEVICE
MINERAL WOOL
(BY OTHERS)
PERIMETER SPACER SCREW
PERIMETER SPACER
PRESSURE PLATE
GASKET

115 16" [50]


COVER CAP

300381
300381

WELD ON GLAZING TAPE


DOOR PIVOTS PROVIDED FOR 90 MIN.
GLASS ONLY
PRESSURE PLATE
PRESSURE PLATE SCREW

23 8" [60] 2116" [53] (DO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


42 INTERIOR APPLICATION

SEALANT AND BACKER


ROD (BY OTHERS)
1/4" THICK ANCHOR
MINERAL WOOL
(BY OTHERS)
ANCHOR BOLT
14GA DOOR (BY OTHERS)
ADAPTOR
PERIMETER SPACER SCREW
PERIMETER SPACER
115 16" [50]

SEALANT AND BACKER


ROD (BY OTHERS)
300381
300381
PRESSURE PLATE
GASKET
PRESSURE PLATE
GLAZING TAPE
PRESSURE PLATE SCREW
PROVIDED FOR 90 MIN.
GLASS ONLY COVER CAP

(DO) 2116" [53] 23 8" [60]

FRAME DIMENSION (FD) CAULK JOINT

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


43 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 48


R191121
60 mm System Interior Section Details - Doors

SLIDING SHEAR CLIP 1/4" THICK


ANCHOR
ANCHOR BOLT
[91.5 - 181.5]

(BY OTHERS) PERIMETER SPACER EXIT DEVICE


3 5 8" - 7 1 8"

SCREW
14GA DOOR
ADAPTOR

115 16" [50]


VARIES

300381
300381

FIRE-RATED GLASS WELD ON GLAZING TAPE


INTUMESCENT TAPE DOOR PIVOTS PROVIDED FOR 90 MIN.
GLASS ONLY
PRESSURE PLATE COVER PRESSURE PLATE
PRESSURE PLATE SCREW CAP GASKET

(DLO) 23 8" [60] 2116" [53] (DO)


FRAME DIMENSION (FD)
ROUGH OPENING (RO)

VERTICAL MULLION WITH SIDELITE DOOR JAMB AT PIVOT


44 INTERIOR APPLICATION

1/4" THICK ANCHOR SLIDING SHEAR CLIP


PERIMETER SPACER
SCREW ANCHOR BOLT
EXIT DEVICE
(BY OTHERS)
14GA DOOR

[91.5 - 181.5]
3 5 8" - 7 1 8"
ADAPTOR
115 16" [50]

VARIES

300381
300381

GLAZING TAPE FIRE-RATED GLASS


PROVIDED FOR 90 MIN.
PRESSURE INTUMESCENT TAPE
GLASS ONLY
PLATE
GASKET COVER PRESSURE PLATE
CAP
PRESSURE PLATE SCREW
(DO) 2116" [53] 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION WITH SIDELITE DOOR JAMB AT LEVER
45 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 49


R191121
60 mm System Exterior Section Details
CAULK
JOINT
ANCHOR BOLT MINERAL WOOL (BY OTHERS)
PERIMETER SPACER (BY OTHERS)
SEALANT AND BACKER
PERIMETER SPACER SCREW ROD (BY OTHERS)
SLIDING SHEAR CLIP

300381
ROUGH OPENING (RO)

COVER CAP
23 8" [60]

1/4" THICK HEAD ANCHOR


PRESSURE PLATE
DIMENSION (FD)

CONNECTING PLATE
FRAME

300381
COVER PLATE BETWEEN
GASKET AND GLASS
(DLO)

FIRE-RATED GLASS

3 5 8" - 7 1 8"
VARIES
[91.5 - 181.5]

HEAD SECTION
46 EXTERIOR APPLICATION

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

SETTING BLOCK
SLIDING SHEAR CLIP
PRESSURE PLATE
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

PRESSURE PLATE
300381

SCREW
23 8" [60]

COVER CAP
PRESSURE PLATE GASKET
300381

DIVERTER GASKET
(DLO)

INTUMESCENT TAPE
CONNECTING PLATE
MULLION GASKET
HORIZONTAL MULLION SECTION
47 EXTERIOR APPLICATION

SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR


(DLO)

ATTACHED TO END OF
ROUGH OPENING (RO)

COVER PLATE BETWEEN


DIMENSION (FD)

VERTICAL MULLION
GASKET AND GLASS
FRAME

SLIDING SHEAR CLIP


PRESSURE PLATE
300381

MINERAL WOOL (BY OTHERS)


23 8" [60]

FLEXIBLE SILICONE
FLASHING SET IN FULL BEARING SHIM
SEALANT BED (BY OTHERS)
300381

SEALANT AND BACKER


ROD (BY OTHERS)
ANCHOR BOLT
CAULK
JOINT

(BY OTHERS)
SILL SECTION
48 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 50


R191121
60 mm System Exterior Section Details
FIRE-RATED GLASS
COVER PLATE BETWEEN
GASKET AND GLASS SLIDING SHEAR CLIP
(DLO)

SETTING BLOCK LINE OF


PRESSURE PLATE INTERIOR FINISH
PRESSURE PLATE

300381
SCREW
23 8" [60]

COVER CAP
PRESSURE PLATE GASKET
300381
DIVERTER GASKET
(DLO)

INTUMESCENT TAPE
CONNECTING PLATE
MULLION GASKET

IN-FILL PANEL BUILDING SLAB


OR SPANDREL UNIT OR SUPPORT
FACE OF VERTICAL COVER CAP
(DLO)

MULLION ANCHORS
(SPECIAL) PER PROJECT
REQUIREMENTS (TYP.)
(DLO)

300381
23 8" [60]

SLIDING SHEAR CLIP


LINE OF
INTERIOR FINISH
300381
(DLO)

VARIES

HORIZONTAL MULLION SECTION WITH MULLION ANCHOR AT SLAB EDGE


49 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 51


R191121
60 mm System Exterior Section Details

SLIDING PAD NOT PER BUILDING SLAB


PROJECT REQUIREMENTS OR SUPPORT
(BY OTHERS)

ANCHOR BOLTS
PER PROJECT
REQUIREMENTS

[91.5 - 181.5]
3 5 8" - 7 1 8"
FIRE-RATED GLASS.
(BY OTHERS)
SEE EXTERIOR GLAZING
OPTIONS. MULLION ANCHORS
(SPECIAL) PER PROJECT
REQUIREMENTS (BY OTHERS)

VARIES
FACE OF HORIZONTAL COVER CAP FACE OF HORIZONTAL COVER CAP
IN-FILL PANEL OR
PRESSURE PLATE
SPANDREL UNIT
SCREW
COVER CAP

DLO 23 8" [60] DLO

VERTICAL MULLION SECTION AT SLAB


50 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 52


R191121
60 mm System Exterior Section Details
1/4" THICK ANCHOR 10GA WELDED SHEAR CLIP
SEALANT AND BACKER #10-24X1/2 UFHMS
ROD (BY OTHERS)
ANCHOR BOLT (BY OTHERS)
SILL ANCHOR SCREW
PERIMETER SPACER SCREW

[91.5 - 181.5]
MINERAL WOOL

3 5 8 " - 7 1 8"
(BY OTHERS)
INTUMESCENT
CAULK (BY OTHERS)
PERIMETER SPACER
FLEXIBLE SILICONE
FLASHING SET
IN SEALANT BED

VARIES
PRESSURE PLATE
GASKET 300381
300381

COVER CAP
INTUMESCENT TAPE
PRESSURE PLATE
PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH WELDED SHEAR CLIP AT SILL


51 EXTERIOR APPLICATION

3 5 8" - 7 1 8"
VARIES
[91.5 - 181.5]
SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR
ATTACHED TO END OF
CONNECTING PLATE FIRE-RATED
VERTICAL MULLION
FRAME DIMENSION (FD)

GLASS
(DLO)

COVER PLATE BETWEEN


ROUGH OPENING (RO)

GASKET AND GLASS 10GA WELDED SHEAR CLIP


#10-24X1/2 UFHMS
SETTING BLOCK
ANCHOR BOLT (BY OTHERS)
PRESSURE PLATE
FULL BEARING SHIM
CAULK JOINT

SELF-DRILING S.S. FACADE


300381

(BY OTHERS)
SCREW @ 12" O.C.
23 8" [60]

COVER CAP MINERAL WOOL (BY OTHERS)

PRESSURE PLATE GASKET SEALANT AND BACKER


300381

ROD (BY OTHERS)


PERIMETER SPACER
FLEXIBLE SILICONE FLASHING
SET IN SEALANT BED
INTUMESCENT
CAULK (BY OTHERS)
SILL SECTION WITH WELDED SHEAR CLIP
52 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 53


R191121
60 mm System Exterior Section Details
SEALANT AND BACKER
ROD (BY OTHERS) 1/4" THICK SILL ANCHOR

SILL ANCHOR SCREW SLIDING SHEAR CLIP


ANCHOR BOLT
MINERAL WOOL (BY

[91.5 - 181.5]
(BY OTHERS)

3 5 8" - 7 1 8"
OTHERS)
PERIMETER SPACER SCREW

INTUMESCENT
CAULK (BY OTHERS)
FLEXIBLE SILICONE
FIRE-RATED GLASS
FLASHING SET IN
SEALANT BED
SEALANT AND BACKER

VARIES
ROD (BY OTHERS)
300381
300381

PERIMETER SPACER
PRESSURE PLATE
INTUMESCENT TAPE
GASKET
PRESSURE PLATE
COVER CAP
PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)


JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL
53 EXTERIOR APPLICATION

1/4" THICK SILL


ANCHOR
[91.5 - 181.5]
3 5 8" - 7 1 8"

ANCHOR BOLT
(BY OTHERS)
SLIDING SHEAR CLIP
FIRE-RATED GLASS
VARIES

300381
300381

MULLION GASKET INTUMESCENT TAPE


PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP PRESSURE PLATE
SCREW

(DLO) 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION
54 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 54


R191121
60 mm System Exterior Section Details - Doors
INTUMESCENT CAULK (BY OTHERS) ANCHOR BOLT MINERAL WOOL
(BY OTHERS) (BY OTHERS)
FLEXIBLE SILICONE FLASHING
SET IN SEALANT BED SEALANT AND
BACKER ROD
PERIMETER SPACER
(BY OTHERS)
PERIMETER SPACER SCREW
SLIDING SHEAR
COVER CAP CLIP

300381
CAULK JOINT

23 8" [60]

PRESSURE PLATE 1/4" THICK


SCREW HEAD ANCHOR
PRESSURE PLATE

300381
14GA DOOR
2116" [53]
ROUGH OPENING (RO)

ADAPTOR
FRAME DIMENSION (FD)

DOOR OPENING (DO)

CLOSER
FACE OF VERTICAL COVER CAP

FACE OF VERTICAL COVER CAP


(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE

115 16" [50]

VARIES

GLAZING TAPE
PROVIDED ON 90 MIN.
(DLO)

RATED GLASS ONLY


FRAME DIMENSION (FD)
ROUGH OPENING (RO)

SETTING BLOCK
DOOR OPENING (DO)

SMOKE SEAL
16" [90]
39
1 " [13]
2

FINISHED FLOOR

HORIZONTAL MULLION, DOOR HEADER, AND BOTTOM RAIL


55 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 55


R191121
60 mm System Exterior Section Details - Doors
COVER PLATE BETWEEN FIRE-RATED GLASS
GASKET AND GLASS
CONNECTING PLATE
(DLO)

SETTING BLOCK
SLIDING SHEAR
PRESSURE PLATE CLIP

300381
COVER CAP
23 8" [60]

PRESSURE PLATE
SCREW
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

300381
14GA DOOR
2116" [53]

ADAPTOR
DOOR OPENING (DO)

CLOSER
(DLO)

PULL PUSH
SIDE SIDE
SECURE EGRESS
SIDE SIDE
(DLO)
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

FACE OF VERTICAL

FACE OF VERTICAL
COVER CAP

COVER CAP
39 16" [90]
(DLO)

GLAZING TAPE
PROVIDED ON 90 MIN.
RATED GLASS ONLY
SETTING BLOCK
(DLO)

SMOKE SEAL
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

DOOR OPENING (DO)

39 16" [90]
1 " [13]
2

FINISHED FLOOR

DOOR HEADER WITH TRANSOM, DOOR MID RAIL, AND BOTTOM RAIL
56 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 56


R191121
60 mm System Exterior Section Details - Doors
1/4" THICK ANCHOR
SEALANT AND BACKER
ROD (BY OTHERS)
ANCHOR BOLT (BY OTHERS)
MINERAL WOOL (BY OTHERS) 14GA DOOR EXIT DEVICE
ADAPTOR
PERIMETER SPACER SCREW
INTUMESCENT CAULK
(BY OTHERS)
PERIMETER SPACER
FLEXIBLE SILICONE

115 16" [50]


FLASHING SET IN
SEALANT BED
PRESSURE PLATE 300381
300381

GASKET WELD ON
DOOR PIVOTS
COVER CAP GLAZING TAPE
PRESSURE PLATE
PROVIDED FOR 90 MIN.
PRESSURE PLATE SCREW GLASS ONLY

23 8" [60] 2116" [53] (DO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

VERTICAL MULLION WITH DOOR JAMB AT PIVOT


57 EXTERIOR APPLICATION

1/4" THICK ANCHOR


SEALANT AND BACKER
ROD (BY OTHERS)
MINERAL WOOL (BY OTHERS)

ANCHOR BOLT PERIMETER SPACER SCREW


(BY OTHERS) PERIMETER SPACER
14GA DOOR INTUMESCENT
ADAPTOR CAULK (BY OTHERS)
FLEXIBLE SILICONE
FLASHING SET IN
115 16" [50]

SEALANT BED
SEALANT AND BACKER
ROD (BY OTHERS)
300381
300381

PRESSURE PLATE
GASKET
GLAZING TAPE WELD ON PRESSURE PLATE
PROVIDED FOR 90 MIN. DOOR PIVOTS
GLASS ONLY PRESSURE PLATE SCREW
(DO) 2116" [53] 23 8" [60] COVER CAP

FRAME DIMENSION (FD) CAULK JOINT

ROUGH OPENING (RO)


VERTICAL MULLION WITH DOOR JAMB AT PIVOT
58 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 57


R191121
60 mm System Exterior Section Details – Doors

SLIDING SHEAR CLIP


ANCHOR BOLT 1/4" THICK
ANCHOR
[91.5 - 181.5]

(BY OTHERS)
3 5 8" - 7 1 8"

PERIMETER SPACER EXIT DEVICE


SCREW
14GA DOOR
ADAPTOR

115 16" [50]


VARIES

300381
300381

FIRE-RATED GLASS WELD ON GLAZING TAPE


INTUMESCENT TAPE DOOR PIVOTS PROVIDED FOR
90 MIN. GLASS ONLY
PRESSURE PLATE COVER PRESSURE PLATE
PRESSURE PLATE SCREW CAP GASKET

(DLO) 23 8" [60] 2116" [53] (DO)


FRAME DIMENSION (FD)
ROUGH OPENING (RO)
VERTICAL MULLION WITH SIDELITE DOOR JAMB AT PIVOT
59 EXTERIOR APPLICATION

1/4" THICK ANCHOR SLIDING SHEAR CLIP


PERIMETER SPACER
SCREW ANCHOR BOLT
EXIT DEVICE
(BY OTHERS)

[91.5 -181.5]
3 5 8" - 7 1 8"
14GA DOOR
ADAPTOR
115 16" [50]

VARIES

300381
300381

GLAZING TAPE FIRE-RATED GLASS


PROVIDED FOR 90 MIN. PRESSURE INTUMESCENT TAPE
GLASS ONLY PLATE COVER PRESSURE PLATE
GASKET CAP
PRESSURE PLATE SCREW
(DO) 2116" [53] 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION WITH SIDELITE DOOR JAMB AT LEVER
60 EXTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 58


R191121
60 mm System Exterior Section Details
CAULK Hurricane Application – Concrete Surrounding Condition
JOINT

SEPARATOR BUSHING ANCHOR BOLT MINERAL WOOL (N.B. TGP)


(N.B. TGP)
PERIMETER SPACER SEALANT AND BACKER
ROD (N.B. TGP)
PERIMETER SPACER SCREW
SLIDING SHEAR CLIP

300381
ROUGH OPENING (RO)

COVER CAP 1/4" THICK HEAD ANCHOR


23 8" [60]

PRESSURE PLATE
DIMENSION (FD)

FIRE-RATED GLASS
CONNECTING PLATE
FRAME

300381
COVER PLATE BETWEEN
GASKET AND GLASS
(DLO)

VARIES 71 8" [181.5]

HEAD SECTION
61 CURTAINWALL HURRICANE

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

SETTING BLOCK
SLIDING SHEAR CLIP
PRESSURE PLATE
FRAME DIMENSION (FD)
ROUGH OPENING (RO)

PRESSURE PLATE
300381

SCREW
23 8" [60]

COVER CAP
PRESSURE PLATE GASKET
300381

DIVERTER GASKET
(DLO)

INTUMESCENT TAPE
CONNECTING PLATE
MULLION GASKET
HORIZONTAL MULLION SECTION
62 CURTAINWALL HURRICANE

SILL ANCHOR SCREW 1/4" THICK SILL ANCHOR


(DLO)

ATTACHED TO END OF
ROUGH OPENING (RO)

COVER PLATE BETWEEN


DIMENSION (FD)

VERTICAL MULLION
GASKET AND GLASS
FRAME

SLIDING SHEAR CLIP


PRESSURE PLATE
300381

MINERAL WOOL (N.B. TGP)


23 8" [60]

FLEXIBLE SILICONE
FLASHING SET IN FULL BEARING SHIM
SEALANT BED (N.B. TGP)
300381

SEALANT AND BACKER


ROD (N.B. TGP)
ANCHOR BOLT (N.B. TGP)
SILL SECTION
CAULK
JOINT

63 CURTAINWALL HURRICANE

800.426.0279 | fireglass.com Architectural Specification Manual 59


R191121
60 mm System Exterior Section Details
Hurricane Application – Concrete Surrounding Condition
1/4" THICK SILL ANCHOR
SEALANT AND BACKER
ROD (N.B. TGP)
SLIDING SHEAR CLIP
MULLION REINFORCEMENT
ANCHOR BOLT
SILL ANCHOR SCREW (N.B. TGP)
MINERAL WOOL (N.B. TGP)

71 8" [181.5]
PERIMETER SPACER SCREW

CONNECTING PLATE
INTUMESCENT
CAULK (N.B. TGP )
MULLION GASKET
SEPARATOR BUSHING FIRE-RATED GLASS

PERIMETER SPACER
PRESSURE PLATE
GASKET

VARIES
FLEXIBLE SILICONE
FLASHING SET IN
SEALANT BED 300381 300381

SEALANT AND BACKER


ROD (N.B. TGP) INTUMESCENT TAPE

COVER CAP PRESSURE PLATE


PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL


64 CURTAINWALL HURRICANE

MULLION REINFORCEMENT
1/4" THICK SILL ANCHOR
ANCHOR BOLT
71 8" [181.5]

(N.B. TGP)
CONNECTING PLATE
MULLION GASKET
SLIDING SHEAR CLIP
FIRE-RATED GLASS
SEPARATOR BUSHING
VARIES

300381 300381

COVER PLATE BETWEEN INTUMESCENT TAPE


GASKET AND GLASS
PRESSURE PLATE
PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP SCREW

(DLO) 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION
65 CURTAINWALL HURRICANE

800.426.0279 | fireglass.com Architectural Specification Manual 60


R191121
60 mm System Exterior Section Details
Hurricane Application – Steel Surrounding Condition

SEPARATOR BUSHING
CAULK
JOINT

PERIMETER SPACER ANCHOR BOLT MINERAL WOOL (N.B. TGP)


(N.B. TGP)
PERIMETER SPACER SCREW SEALANT AND BACKER
ROD (N.B. TGP)
DIVERTER GASKET
SLIDING SHEAR CLIP

300381
COVER CAP 1/4" THICK HEAD ANCHOR
23 8" [60]

PRESSURE PLATE SCREW


ROUGH OPENING (RO)

FRAME DIMENSION (FD)

PRESSURE PLATE
300381

CONNECTING PLATE

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

INTUMESCENT TAPE
FIRE-RATED GLASS
MULLION GASKET

VARIES 71 8" [181.5]


HEAD SECTION
66 CURTAINWALL HURRICANE

SILL ANCHOR SCREW


MULLION GASKET
FIRE-RATED GLASS
FRAME DIMENSION (FD)

(DLO)

CONNECTING PLATE
ROUGH OPENING (RO)

COVER PLATE BETWEEN 1/4" THICK SILL ANCHOR


GASKET AND GLASS ATTACHED TO END OF
VERTICAL MULLION
SETTING BLOCK
SLIDING SHEAR CLIP
PRESSURE PLATE
300381

MINERAL WOOL (N.B. TGP)


23 8" [60]

COVER CAP
FULL BEARING SHIM
PERIMETER SPACER (N.B. TGP)
300381

SEALANT AND BACKER


SEALANT AND BACKER ROD (N.B. TGP)
ROD (N.B. TGP)
ANCHOR BOLT (N.B. TGP)
CAULK

FLEXIBLE SILICONE SILL SECTION


JOINT

FLASHING SET IN 67 CURTAINWALL HURRICANE


SEALANT BED

800.426.0279 | fireglass.com Architectural Specification Manual 61


R191121
60 mm System Exterior Section Details
Hurricane Application – Steel Surrounding Condition
1/4" THICK SILL ANCHOR
SEALANT AND BACKER
ROD (N.B. TGP)
MULLION REINFORCEMENT SLIDING SHEAR CLIP
SILL ANCHOR SCREW ANCHOR BOLT
(N.B. TGP)
MINERAL WOOL (N.B. TGP)

71 8" [181.5]
PERIMETER SPACER SCREW

CONNECTING PLATE
INTUMESCENT
CAULK (N.B. TGP )
MULLION GASKET
SEPARATOR BUSHING
PERIMETER SPACER
PRESSURE PLATE
GASKET

VARIES
FLEXIBLE SILICONE
FLASHING SET IN
SEALANT BED 300381 300381

SEALANT AND BACKER


ROD (N.B. TGP) INTUMESCENT TAPE

COVER CAP PRESSURE PLATE


PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL


68 CURTAINWALL HURRICANE

MULLION REINFORCEMENT
1/4" THICK SILL ANCHOR
ANCHOR BOLT
71 8" [181.5]

(N.B. TGP)
CONNECTING PLATE
MULLION GASKET
SLIDING SHEAR CLIP
FIRE-RATED GLASS
SEPARATOR BUSHING
VARIES

300381 300381

COVER PLATE BETWEEN INTUMESCENT TAPE


GASKET AND GLASS
PRESSURE PLATE
PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP SCREW

(DLO) 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION
69 CURTAINWALL HURRICANE

800.426.0279 | fireglass.com Architectural Specification Manual 62


R191121
60 mm System Exterior Section Details
Hurricane Application – Timber Surrounding Condition

ANCHOR BOLT
SEPARATOR BUSHING (N.B. TGP)
CAULK
JOINT

PERIMETER SPACER MINERAL WOOL (N.B. TGP)

PERIMETER SPACER SCREW SEALANT AND BACKER


ROD (N.B. TGP)
DIVERTER GASKET
SLIDING SHEAR CLIP

300381
COVER CAP 1/4" THICK HEAD ANCHOR
23 8" [60]

PRESSURE PLATE SCREW


ROUGH OPENING (RO)

FRAME DIMENSION (FD)

PRESSURE PLATE
300381

CONNECTING PLATE

COVER PLATE BETWEEN


GASKET AND GLASS
(DLO)

INTUMESCENT TAPE
FIRE-RATED GLASS
MULLION GASKET

VARIES 71 8" [181.5]

HEAD SECTION
70 CURTAINWALL HURRICANE

SILL ANCHOR SCREW


MULLION GASKET
FIRE-RATED GLASS
FRAME DIMENSION (FD)

(DLO)

CONNECTING PLATE
ROUGH OPENING (RO)

COVER PLATE BETWEEN 1/4" THICK SILL ANCHOR


GASKET AND GLASS ATTACHED TO END OF
VERTICAL MULLION
SETTING BLOCK
SLIDING SHEAR CLIP
300381

PRESSURE PLATE
MINERAL WOOL (N.B. TGP)
23 8" [60]

COVER CAP
FULL BEARING SHIM
PERIMETER SPACER (N.B. TGP)
300381

SEALANT AND BACKER


SEALANT AND BACKER ROD (N.B. TGP)
ROD (N.B. TGP)
ANCHOR BOLT
CAULK

FLEXIBLE SILICONE SILL SECTION


JOINT

71 (N.B. TGP)
FLASHING SET IN CURTAINWALL HURRICANE
SEALANT BED

800.426.0279 | fireglass.com Architectural Specification Manual 63


R191121
60 mm System Exterior Section Details
Hurricane Application – Timber Surrounding Condition
1/4" THICK SILL ANCHOR
SEALANT AND BACKER
ROD (N.B. TGP)
MULLION REINFORCEMENT
SILL ANCHOR SCREW
SLIDING SHEAR
MINERAL WOOL (N.B. TGP) CLIP

71 8" [181.5]
PERIMETER SPACER SCREW ANCHOR BOLT
(N.B. TGP)
CONNECTING PLATE
INTUMESCENT
CAULK (N.B. TGP )
MULLION GASKET
SEPARATOR BUSHING
PERIMETER SPACER
PRESSURE PLATE
GASKET

VARIES
FLEXIBLE SILICONE
FLASHING SET IN
SEALANT BED 300381 300381

SEALANT AND BACKER


ROD (N.B. TGP) INTUMESCENT TAPE

COVER CAP PRESSURE PLATE


PRESSURE PLATE SCREW
23 8" [60] (DLO)

CAULK JOINT FRAME DIMENSION (FD)

ROUGH OPENING (RO)

JAMB SECTION WITH SLIDING SHEAR CLIP AT SILL


72 CURTAINWALL HURRICANE

MULLION REINFORCEMENT
1/4" THICK SILL ANCHOR
ANCHOR BOLT
71 8" [181.5]

(N.B. TGP)
CONNECTING PLATE
MULLION GASKET
SLIDING SHEAR CLIP
FIRE-RATED GLASS
SEPARATOR BUSHING
VARIES

300381 300381

COVER PLATE BETWEEN INTUMESCENT TAPE


GASKET AND GLASS
PRESSURE PLATE
PRESSURE PLATE GASKET PRESSURE PLATE
COVER CAP SCREW

(DLO) 23 8" [60] (DLO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)


VERTICAL MULLION
73 CURTAINWALL HURRICANE

800.426.0279 | fireglass.com Architectural Specification Manual 64


R191121
Section Details - Doors
Fireframes Designer Series or Fireframes Heat Barrier Series doors, or appropriately rated door by others in a
Fireframes Designer Series door frame may be used within the Fireframes Curtainwall Series frames. Doors must
be installed before glazing.

NOTE: Refer to product specific Installation Manual for the door(s) supplied with your order.

GLAZING BEAD
BEAD STUD
INTERIOR
BEAD LOCK SCREW
2" [50]

EXTERIOR
FIRE-RATED GLASS
GLAZING TAPE
WEATHERSTRIPPING
LEVERS SEAL

(DLO) 61 8" [156] (DLO)

DOOR OPENING (DO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)

ACTIVE / ACTIVE MEETING STILE (STAINLESS STEEL PROFILES)


74 DESIGNER SERIES FRAME

EXIT DEVICE EXIT DEVICE

GASKET GLAZING BEAD


BEAD STUD
INTERIOR
BEAD LOCK SCREW
115 16" [50]

EXTERIOR FIRE-RATED GLASS


GLAZING TAPE

LEVERS
(DLO) 6" [152] (DLO)

DOOR OPENING (DO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)

ACTIVE / ACTIVE MEETING STILE (STEEL PROFILES)


75 DESIGNER SERIES FRAME

800.426.0279 | fireglass.com Architectural Specification Manual 65


R191121
Section Details – Doors

EXIT DEVICE
STRIKE

GLAZING BEAD
BEAD LOCK SCREW
BEAD STUD
115 16" [50]

FIRE-RATED GLASS

LEVER

(DLO) 57 8" [150] (DLO)

DOOR OPENING (DO)

FRAME DIMENSION (FD)

ROUGH OPENING (RO)

ACTIVE / FIXED MEETING STILE


76 DESIGNER SERIES FRAME

800.426.0279 | fireglass.com Architectural Specification Manual 66


R191121
Corner Details
CORNER MULLION (INTERIOR APPLICATIONS ONLY)
• Corner mullions MUST be installed before the glazing material.
• Corners may be inside or outside corners ranging from 10° to 135°.
• Corner mullion should be set and installed next to first vertical mullion before setting second vertical
mullion.

VARIES ON MULLION
DEPTH

0.050 ALUMINUM TRIM CLADDING, VERTICAL MULLION


ADHERED WITH SUPPLIED 3M VHB WITH GASKETS
TAPE, FINISHED TO MATCH FRAME
CORNER
CORNER MULLION
MULLION

FIRE-RATED 3M VHB DOUBLE


INSULATION SIDED TAPE
90
°

FIRE-RATED INSULATION: MINERAL


WOOL OR INTUMESCENT CAULK 3M
CP25, BACKER ROD AND SEALANT
(BY INSTALLER)

VERTICAL MULLION PEEL BACKING FROM


3M VHB TAPE AND
CAREFULLY APPLY
TRIM CLADDING

90 DEGREE INSIDE CORNER CORNER CLADDING INSTALLATION ISOMETRIC VIEW


77 INTERIOR APPLICATION 79 INTERIOR APPLICATION

0.050 ALUMINUM TRIM CLADDING,


ADHERED WITH SUPPLIED 3M VHB
TAPE, FINISHED TO MATCH FRAME

VARIES ON MULLION FIRE-RATED INSULATION


DEPTH CORNER MULLION
FIRE-RATED INSULATION:
MINERAL WOOL OR
INTUMESCENT CAULK 3M CP25
(BY INSTALLER)

CORNER MULLION
3M VHB DOUBLE SIDED TAPE
REMOVE PSA BACKING
0.050 ALUMINUM
TRIM CLADDING
°
90

VERTICAL MULLION

90 DEGREE OUTSIDE CORNER CORNER CLADDING INSTALLATION TOP VIEW


78 INTERIOR APPLICATION 80 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 67


R191121
Corner Detail

REMOVE DART ON FLEXIBLE


FLASHING WHERE SHOWN
VERTICAL MULLION

HORIZONTAL MULLION
VERTICAL MULLION GASKET
(DART REMOVED AT
VERTICAL FLASHING)

CONNECTING PLATE
AND SCREWS MOLDED CORNER FLASHING

FLEXIBLE FLASHING

VERTICAL MULLION GASKET


(DART REMOVED AT JAMB)
REMOVE GASKET BULB
WHERE SHOWN
HORIZONTAL MULLION GASKET
(DART REMOVED AT SILL FLASHING)

CORNER DETAIL
81 INTERIOR APPLICATION

800.426.0279 | fireglass.com Architectural Specification Manual 68


R191121

You might also like