Annexure-A

TECHNICAL SPECIFICATION OF DIGITAL WATER FLOW METER (NON HAZARDOUS AREA)

Sr. Parameters Description


No.
1. Operating Principle Electromagnetic Induction
 Digital Display Cumulative flow totalizer
(S.I Unit cubic meters m3, Litre)
2. Display Type
 LCD Display – 6 Digit for flow rate & 8 Digit
for Totalizer flow
3. Application media Ground Water
Input: 100 to 230 VAC, 50 Hz.
4. Power supply & Output
Output: 4-20mA
 Ambient temperature - 5 °C to 55°C Non-
5. Operating Environment condensing
 Relative humidity (0-95%)
Kindly refer Annexure-B for pipe dia. and its
6. Nominal diameter/ Line Size
material.
7. Electronic Enclosure Aluminium Die Cast
8. Electronic Enclosure Weather Proof IP67
9. Sensor/Flow tube protection class Weather proof IP-67
10. Communication Communication Output 1 - RS485 (MODBUS RTU)
11. Process Connection Flanged
12. Flange Standard and Ratings Flange ANSI 150 B16.5
13. Process Connection (Flanged) MoC MS
14. MoC Coil Housing SS
15. Flow tube lining material PTFE
16. MOC Flow Tube/Sensor Rod SS
17. MOC Electrode SS
18. Max. pressure 10 kg/cm2
0-20,000 Liter per hour for 1.5 Inch Size
19. Max. flow
0-20,000 Liter per hour for 2.0 Inch Size
+/- 1 % accuracy over complete velocity range as
20. Flow-meters accuracy supplied
21. Warranty 2 Years
22. Discharge side of meter Downstream of the meter
23. Intake side of the meter Upstream of the meter
Each meter is to have a have a factory wet
24. Calibration calibration certificate stating the calibration date,
time and accuracy of the meter.
25. Mounting in line Horizontal or Vertical mounted as per site
conditions
26. fittings SS type
27. Electric Wiring Port and Cable Water Resistant Type

You might also like