The document provides the technical specifications for a digital water flow meter for non-hazardous areas. The meter uses electromagnetic induction to measure flow and displays the flow rate and totalizer on an LCD screen. It has an operating temperature range of 5-55°C and humidity of 0-95%. The meter enclosure and sensor protection are rated IP67 and it interfaces via RS485 Modbus RTU. Each meter is factory calibrated and supplied with a certificate stating the calibration details and accuracy.
Original Description:
Original Title
Annexure A-TS of Digital Water flow meter Final 21.09.2020
The document provides the technical specifications for a digital water flow meter for non-hazardous areas. The meter uses electromagnetic induction to measure flow and displays the flow rate and totalizer on an LCD screen. It has an operating temperature range of 5-55°C and humidity of 0-95%. The meter enclosure and sensor protection are rated IP67 and it interfaces via RS485 Modbus RTU. Each meter is factory calibrated and supplied with a certificate stating the calibration details and accuracy.
The document provides the technical specifications for a digital water flow meter for non-hazardous areas. The meter uses electromagnetic induction to measure flow and displays the flow rate and totalizer on an LCD screen. It has an operating temperature range of 5-55°C and humidity of 0-95%. The meter enclosure and sensor protection are rated IP67 and it interfaces via RS485 Modbus RTU. Each meter is factory calibrated and supplied with a certificate stating the calibration details and accuracy.
TECHNICAL SPECIFICATION OF DIGITAL WATER FLOW METER (NON HAZARDOUS AREA)
Sr. Parameters Description
No. 1. Operating Principle Electromagnetic Induction Digital Display Cumulative flow totalizer (S.I Unit cubic meters m3, Litre) 2. Display Type LCD Display – 6 Digit for flow rate & 8 Digit for Totalizer flow 3. Application media Ground Water Input: 100 to 230 VAC, 50 Hz. 4. Power supply & Output Output: 4-20mA Ambient temperature - 5 °C to 55°C Non- 5. Operating Environment condensing Relative humidity (0-95%) Kindly refer Annexure-B for pipe dia. and its 6. Nominal diameter/ Line Size material. 7. Electronic Enclosure Aluminium Die Cast 8. Electronic Enclosure Weather Proof IP67 9. Sensor/Flow tube protection class Weather proof IP-67 10. Communication Communication Output 1 - RS485 (MODBUS RTU) 11. Process Connection Flanged 12. Flange Standard and Ratings Flange ANSI 150 B16.5 13. Process Connection (Flanged) MoC MS 14. MoC Coil Housing SS 15. Flow tube lining material PTFE 16. MOC Flow Tube/Sensor Rod SS 17. MOC Electrode SS 18. Max. pressure 10 kg/cm2 0-20,000 Liter per hour for 1.5 Inch Size 19. Max. flow 0-20,000 Liter per hour for 2.0 Inch Size +/- 1 % accuracy over complete velocity range as 20. Flow-meters accuracy supplied 21. Warranty 2 Years 22. Discharge side of meter Downstream of the meter 23. Intake side of the meter Upstream of the meter Each meter is to have a have a factory wet 24. Calibration calibration certificate stating the calibration date, time and accuracy of the meter. 25. Mounting in line Horizontal or Vertical mounted as per site conditions 26. fittings SS type 27. Electric Wiring Port and Cable Water Resistant Type