Proportional Directional Valve, Direct Operated Without Electrical Position Feedback Type WRA XE
Proportional Directional Valve, Direct Operated Without Electrical Position Feedback Type WRA XE
29055-XE
Edition: 2019-09
Replaces: 2016-04
RA78494041_AA
ATEX units
For potentially explosive atmospheres
Information on explosion protection:
▶▶ Area of application in accordance with the
Explosion Protection Directive 2014/34/EU: II 2G
▶▶ Type of protection valve:
Ex h IIC T4 Gb X according to EN 80079-36
▶▶ Type of protection valve solenoids:
Ex eb mb IIC T4 Gb according to
EN 60079-7 / EN 60079-18
H8091 ▶▶ Valve solenoid certified according to IECEx
Features Contents
Ordering code
01 02 03 04 05 06 07 08 09
4WRA 6 – 2X / G24 XE J / V
02 Size 6 6
Rated flow
04 6 l/min 07
10 l/min 15
18 l/min 30
Explosion protection
07 "Increased safety" XE
For details, see information on the explosion protection page 6
Seal material (observe compatibility of seals with hydraulic fluid used, see page 5)
09 NBR seals M
FKM seals V
Symbols
A B A B A B A B
a 0 a 0 a 0 b a 0 b
a b a b
P T P T P T P T
EA E
E1-
WA W
W1-
Notice:
▶▶ In spool position "0", symbols W, W1-, and WA have
a connection from A → T and B → T with approx. 3% of the
relevant nominal cross-section.
▶▶ Representation according to DIN ISO 1219-1.
▶▶ Hydraulic interim positions are shown by dashes.
Function, section
Notice:
Regarding the 4/3-way version of the valves,
only one solenoid may be actuated at a time.
„a“ „b“
A T B
Type 4WRA 6 ...XE (P)
5 3 1 2 4 7 6
Notice:
The tank line must not be allowed to run empty. With
corresponding installation conditions, a preload valve
(preload pressure approx. 2 bar) must be installed.
Technical data
(for applications outside these values, please consult us!)
General
Installation position Any, preferably horizontal
Storage temperature range °C +5 … +40
Maximum storage time Years 1
Ambient temperature range °C –20 … +60
Weight ▶▶ 3 spool positions kg 4.4
▶▶ 2 spool positions kg 2.7
Surface protection galvanized
Maximum surface temperature °C See information on explosion protection, page 6
Hydraulic
Maximum operating pressure ▶▶ Ports P, A, B bar 315
▶▶ Port T bar 210
Rated flows qv rated with ∆p = 10 bar l/min 6; 10; 18
Maximum flow l/min 22
Hydraulic fluid see table page 5
Hydraulic fluid temperature range °C –20 ... +80 (NBR seals)
–15 ... +80 (FKM seals)
Viscosity range mm2/s 20 ... 380 (preferably 30 ... 46)
Maximum admissible degree of contamination of the hydraulic fluid; Class 17/15/12 1)
Technical data
(for applications outside these values, please consult us!)
Technical data
(for applications outside these values, please consult us!)
Electric
Voltage type Direct voltage
Type of signal analog
Maximum current per solenoid A 1.03
Duty cycle % 100
Control electronics 4)
Amplifier module for the control of explosion-proof proportional VT-MSPA2-200-1X/V0/0 according to data sheet 30228-200
directional valves 4WRA...XE, 3DREP 6...XE and 4WRZ...XE
Module for monitoring and limiting the solenoid currents with VT-MUXA2-2-1X/V0/1A according to data sheet 30290
proportional valves
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
Flow in l/min→
8
2 10 1
6 1 8
6
4
4
2
2
0 0
300 400 500 600 700 800 900 1000 300 400 500 600 700 800 900 1000
Current in mA → Current in mA →
Version "30"
24 3; 4
22 2
20 5
18 1
Flow in l/min→
16 1 ∆p = 10 bar constant
14 2 ∆p = 20 bar constant
12 3 ∆p = 30 bar constant
10 4 ∆p = 50 bar constant
8 5 ∆p = 100 bar constant
6
4 ∆p = valve pressure differential according to DIN 24311 (inlet
2 pressure minus load pressure and minus return flow pressure)
0
300 400 500 600 700 800 900 1000
Current in mA →
100 4
Change of input signal in %
1 0 → 25 → 0
2 0 → 50 → 0
75 3
Stroke in % →
3 0 → 75 → 0
4 0 → 100 → 0
50 2
Measured with pilot pressure pST = 10 bar
25 1
0
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Time in ms →
Performance limits
(measured with HLP46, ϑoil = 40 ±5 °C)
10 12
10
Flow in l/min→
Flow in l/min→
8
8
6
6
4
4
2 2
0 0
0 50 100 150 200 250 0 50 100 150 200 250
Pressure differential in bar → Pressure differential in bar →
Version "30"
25
20
Flow in l/min→
15
10
0
0 50 100 150 200 250
Pressure differential in bar →
Dimensions
(dimensions in mm)
2 4 5 1 3
98
74.5
„a“ „b“
23.5
42
13.6
91 55.6
155
224
285
6 7
T
A B
45
72
0,01/100
0.01/100
15
Rzmax 4
F1 F2
8
T
Required surface quality of the
8 valve contact surface
47
A B
F4 G F3
P Subplates (separate order) with porting pattern
according to ISO 4401-03-02-0-05, see data sheet 45100.
Electrical connection
1 2 1)
+(-)
Suppressor diode
DC/PWM
47 V, 1.5 kW
-(+)
PE
1) Recommended pre-fuse
3 characteristics medium time-lag according to DIN 41571, 1.25 A.
Cable gland
Type approval II 2G Ex e IIC Gb
Threaded connection M20 x 1.5
Protection class according to EN 60529 IP66 (With correctly installed electrical connection)
Line diameter mm 7 … 10.5
Sealing Outer sheath sealing
Connection line
Line type non-armored cables and lines (outer sheath sealing)
Temperature range °C ≤ -20 … ≥ +110
Notice: Notice:
A fuse which corresponds to the rated current according Only use finely stranded conductors if they have pressed-on wire
to DIN 41571 and EN / IEC 60127 has to be connected upstream end ferrules.
of every valve solenoid (max. 3 x Irated).
The shut-off threshold of the fuse has to match the prospective
short-circuit current of the supply source.
The prospective short-circuit current of the supply source may
amount to a maximum of 1500 A.
This fuse may only be installed outside the potentially explosive
atmospheres or must be of an explosion-proof design.
Installation conditions
(dimensions in mm)
≥ 55
≥ 60
≥ 58 ≥ 64
≥ 85
Notice:
Observe the "Special application conditions for safe application"
on page 6.
Further information