Design Calculation of Typical Cantilever RC Slab 1m Span 125mm THK

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 14

Design Calculation of Typical Cantilever RC Slab 1m Span 125mm THK

variable value unit


span = 1.00 m
spacing = 1.00 m
slab thickness = 125.00 mm
concrete weight = 25.00 kN/m3
self weight of slab = 3.13 kN/m2
live load = 3.00 kN/m2
finishes = 1.25 kN/m2
Gk = 4.38 kN/m
Qk = 3.00 kN/m
factored uniform load = 10.41 kN/m
max moment = 5.20 kN m
max shear = 10.41 KN
fck = 25.00 N/mm2
fyk = 500.00 N/mm2
fctm = 2.56 N/mm2
b = 1000.00 mm
h = 125.00 mm
cover depth = 25.00 mm
rebar diameter = 10.00 mm
d = 95.00 mm

tension reinforcement
k = 0.02 < 0.167
0.5+(0.25-3k/3.4)^0.5 = 0.98 > 0.95
z = 90.25
As,req = 132.53 mm2
As,min = 126.46 mm2 > 123.5
As,max = 5000.00 mm2
As,prov = 524.00 mm2
> 132.53
> 126.464
< 5000
check for bending moment
Mrd = 37.68 kN m > 5.203125

check for deflection


preq = 0.14 %
basic l/d = 13.80
k = 0.40
f1 = 1.00
f2 = 1.00
Gk/Qk = 1.46
Ψ2 = 0.30
σsu = 220.50 N/mm2
δ = 1.00
σs = 55.77 N/mm2
f3 = 5.56
allowable l/d = 30.68
actual l/d = 10.53 < 30.68222

Design Calculation of Typical Cantilever RC Slab 2m Span 150mm THK


variable value unit
span = 2.00 m
spacing = 1.00 m
slab thickness = 150.00 mm
concrete weight = 25.00 kN/m3
self weight of slab = 3.75 kN/m2
live load = 3.00 kN/m2
finishes = 1.25 kN/m2
Gk = 5.00 kN/m
Qk = 3.00 kN/m
factored uniform load = 11.25 kN/m
max moment = 22.50 kN m
max shear = 22.50 KN
fck = 25.00 N/mm2
fyk = 500.00 N/mm2
fctm = 2.56 N/mm2
b = 1000.00 mm
h = 150.00 mm
cover depth = 25.00 mm
rebar diameter = 10.00 mm
d = 120.00 mm

tension reinforcement
k = 0.06 < 0.167
0.5+(0.25-3k/3.4)^0.5 = 0.94 < 0.95
z = 112.97
As,req = 457.85 mm2
As,min = 159.74 mm2 > 156
As,max = 6000.00 mm2
As,prov = 524.00 mm2
> 457.85
> 159.744
< 6000
check for bending moment
Mrd = 60.12 kN m > 22.5
check for deflection
preq = 0.38 %
basic l/d = 24.00
k = 0.40
f1 = 1.00
f2 = 1.00
Gk/Qk = 1.67
Ψ2 = 0.30
σsu = 228.13 N/mm2
δ = 1.00
σs = 199.34 N/mm2
f3 = 1.56
allowable l/d = 14.93
actual l/d = 16.67 < 14.92958

Design Calculation of Typical Cantilever RC Slab 3m Span 175mm THK


variable value unit
span = 3.00 m
spacing = 1.00 m
slab thickness = 175.00 mm
concrete weight = 25.00 kN/m3
self weight of slab = 4.38 kN/m2
live load = 3.00 kN/m2
finishes = 1.25 kN/m2
Gk = 5.63 kN/m
Qk = 3.00 kN/m
factored uniform load = 12.09 kN/m
max moment = 54.42 kN m
max shear = 36.28 KN
fck = 25.00 N/mm2
fyk = 500.00 N/mm2
fctm = 2.56 N/mm2
b = 1000.00 mm
h = 175.00 mm
cover depth = 25.00 mm
rebar diameter = 13.00 mm
d = 143.50 mm

tension reinforcement
k = 0.11 < 0.167
0.5+(0.25-3k/3.4)^0.5 = 0.90 < 0.95
z = 128.56
As,req = 973.15 mm2
As,min = 191.03 mm2 > 186.55
As,max = 7000.00 mm2
As,prov = 1062.00 mm2
> 973.15
> 191.0272
< 7000
check for bending moment
Mrd = 85.97 kN m > 54.42188

check for deflection


preq = 0.68 %
basic l/d = 16.50
k = 0.40
f1 = 1.00
f2 = 1.00
Gk/Qk = 1.88
Ψ2 = 0.30
σsu = 234.70 N/mm2
δ = 1.00
σs = 215.06 N/mm2
f3 = 1.44
allowable l/d = 9.51
actual l/d = 20.91 < 9.513502

Design Calculation of Typical Cantilever RC Slab 4m Span 200mm THK


variable value unit
span = 4.00 m
spacing = 1.00 m
slab thickness = 200.00 mm
concrete weight = 25.00 kN/m3
self weight of slab = 5.00 kN/m2
live load = 3.00 kN/m2
finishes = 1.25 kN/m2
Gk = 6.25 kN/m
Qk = 3.00 kN/m
factored uniform load = 12.94 kN/m
max moment = 103.50 kN m
max shear = 51.75 KN
fck = 25.00 N/mm2
fyk = 500.00 N/mm2
fctm = 2.56 N/mm2
b = 1000.00 mm
h = 200.00 mm
cover depth = 25.00 mm
rebar diameter = 16.00 mm
d = 167.00 mm
tension reinforcement
k = 0.15 < 0.167
0.5+(0.25-3k/3.4)^0.5 = 0.84 < 0.95
z = 141.11
As,req = 1686.10 mm2
As,min = 222.31 mm2 > 217.1
As,max = 8000.00 mm2
As,prov = 2011.00 mm2
> 1686.10
> 222.3104
< 8000
check for bending moment
Mrd = 116.44 kN m > 103.5

check for deflection


preq = 1.01 %
basic l/d = 15.00
k = 0.40
f1 = 1.00
f2 = 1.00
Gk/Qk = 2.08
Ψ2 = 0.30
σsu = 240.41 N/mm2
δ = 1.00
σs = 201.57 N/mm2
f3 = 1.54
allowable l/d = 9.23
actual l/d = 23.95 < 9.227783

Design Calculation of Typical Cantilever RC Slab 5m Span 250mm THK


variable value unit
span = 5.00 m
spacing = 1.00 m
slab thickness = 250.00 mm
concrete weight = 25.00 kN/m3
self weight of slab = 6.25 kN/m2
live load = 3.00 kN/m2
finishes = 1.25 kN/m2
Gk = 7.50 kN/m
Qk = 3.00 kN/m
factored uniform load = 14.63 kN/m
max moment = 182.81 kN m
max shear = 73.13 KN
fck = 25.00 N/mm2
fyk = 500.00 N/mm2
fctm = 2.56 N/mm2
b = 1000.00 mm
h = 250.00 mm
cover depth = 25.00 mm
rebar diameter = 20.00 mm
d = 215.00 mm

tension reinforcement
k = 0.16 < 0.167
0.5+(0.25-3k/3.4)^0.5 = 0.83 < 0.95
z = 178.94
As,req = 2348.57 mm2
As,min = 286.21 mm2 > 279.5
As,max = 10000.00 mm2
As,prov = 2513.00 mm2
> 2348.57
> 286.208
< 10000
check for bending moment
Mrd = 192.99 kN m > 182.8125

check for deflection


preq = 1.09 %
basic l/d = 14.50
k = 0.40
f1 = 1.00
f2 = 1.00
Gk/Qk = 2.50
Ψ2 = 0.30
σsu = 249.85 N/mm2
δ = 1.00
σs = 233.50 N/mm2
f3 = 1.33
allowable l/d = 7.70
actual l/d = 23.26 < 7.700282

Design Calculation of Typical Cantilever RC Slab 6m Span 300mm THK


variable value unit
span = 6.00 m
spacing = 1.00 m
slab thickness = 300.00 mm
concrete weight = 25.00 kN/m3
self weight of slab = 7.50 kN/m2
live load = 3.00 kN/m2
finishes = 1.25 kN/m2
Gk = 8.75 kN/m
Qk = 3.00 kN/m
factored uniform load = 16.31 kN/m
max moment = 293.63 kN m
max shear = 97.88 KN
fck = 25.00 N/mm2
fyk = 500.00 N/mm2
fctm = 2.56 N/mm2
b = 1000.00 mm
h = 300.00 mm
cover depth = 25.00 mm
rebar diameter = 16.00 mm
d = 267.00 mm

tension reinforcement
k = 0.16 < 0.167
0.5+(0.25-3k/3.4)^0.5 = 0.82 < 0.95
z = 219.87
As,req = 3070.06 mm2
As,min = 355.43 mm2 > 347.1
As,max = 12000.00 mm2
As,prov = 3352.00 mm2
> 3070.06
> 355.4304
< 12000
check for bending moment
Mrd = 297.63 kN m > 293.625

check for deflection


preq = 1.15 %
basic l/d = 14.20
k = 0.40
f1 = 1.00
f2 = 1.00
Gk/Qk = 2.92
Ψ2 = 0.30
σsu = 257.33 N/mm2
δ = 1.00
σs = 235.69 N/mm2
f3 = 1.32
allowable l/d = 7.47
actual l/d = 22.47 < 7.470875
pan 125mm THK
comment

compression steel not required

H10-150

OK

OK

from figure 7
residential area

zero moment redistribution

OK

pan 150mm THK


comment

compression steel not required

H10-150

OK

OK
from figure 7

residential area

zero moment redistribution

NG

pan 175mm THK


comment

compression steel not required


H13-125

OK

OK

from figure 7

residential area

zero moment redistribution

NG

pan 200mm THK


comment
compression steel not required

H16-100

OK

OK

from figure 7

residential area

zero moment redistribution

NG

pan 250mm THK


comment
compression steel not required

H20-125

OK

OK

from figure 7

residential area

zero moment redistribution

NG

pan 300mm THK


comment
compression steel not required

H16-60

OK

OK

from figure 7

residential area

zero moment redistribution

NG