The front panel of the OmniScan MX2 contains all the main controls and indicators. This panel is divided To start up the OmniScan MX2
into seven areas: the touch-screen display, the main control area, the function keys, the power button, the
Press the power button.
increment keys, the Help key, and the indicator lights.
Getting Started
The system starts up and performs a memory check. If there is more than one application installed on
Display touch Alarm indicator your instrument, each application will be displayed in one of the buttons appearing on the OmniScan
screen lights MX2 touch screen. Choose the desired inspection application by tapping the appropriate menu on the
OmniScan MX2
touch screen.
If the system encounters a problem during its start-up phase, the power indicator light uses a color
code to identify the nature of the problem. Refer to the OmniScan MX and MX2 — User’s Manual (P/N:
Increment DMTA-20015-01EN [U8778402]) for more details. Intended Use
keys
Main control To shut down the OmniScan MX2 The OmniScan MX2 is designed to perform nondestructive inspections of industrial and commercial
area materials. Do not use the OmniScan MX2 for any purpose other than its intended use.
Press down and hold the power button for three seconds.
Acquisition
indicator light
Adaptors Instruction Manual
The following figure shows how the OmniScan MX2 can be integrated with your existing equipment. Before use, thoroughly review the OmniScan MX and MX2 — User’s Manual (P/N: DMTA-20015-01EN
Function keys Function [U8778402]), and use the product as instructed. The User’s Manual contains essential information on how
keys to use this Olympus product safely and effectively. Keep the User’s Manual in a safe, accessible location.
Scanner with DE15 encoder
cable
Safety Signal Words
Power
indicator light
Indicates an imminently hazardous situation calling attention to a procedure, practice, or the like,
which, if not correctly performed or adhered to, could result in death or serious personal injury.
Help key Power button DE15 to Lemo encoder
cable adaptor (U8775201)
Indicates a potentially hazardous situation calling attention to a procedure, practice, or the like,
Adaptors which, if not correctly performed or adhered to, could result in death or serious personal injury.
Main Control Area Phased array extension
To scanner interface
cable (U8800635 or
You can control the OmniScan MX2 using the main control area alone. similar)
Indicates a potentially hazardous situation calling attention to a procedure, practice, or the like,
which, if not correctly performed or adhered to, could result in minor or moderate personal injury,
Element Name Description material damage, particularly to the product, destruction of part or all of the product, or loss of data.
For other status indications, refer to the OmniScan MX and MX2 User’s Manual (P/N: DMTA-20015-01EN
[U8778402]).
The OmniScan MX2 DC power adaptor (P/N: OMNI-A-AC [U8767093]) is designed to charge
OmniScan MX2 batteries only (P/N: OMNI-A-BATT [U8760010]). Do not attempt to charge any other
type of battery, or use any other chargers/adaptors. Doing so could cause an explosion or injury.
Do not attempt to power or charge other electronic equipment with the OMNI-A-AC DC power
Serial port adaptor, as doing so could cause an explosion resulting in death or serious personal injury.
SDHC memory card slot