Professional Documents
Culture Documents
43-142 - A503 - Stair and Railing Details (Version)
43-142 - A503 - Stair and Railing Details (Version)
TYP.
CONC. WALL
1-1/2" DIA. ALUM. POST
1/4"
1-1/2" DIA. ALUM. HANDRAIL
2 1/4"
WITH WHITE ESP FINISH @ 34"
3"
1 1/2"
SUBMIT SHOP DRAWINGS
1 1/2"
P : 3 0 5 7 4 0 6 9 4 8
NEW CAST-IN-PLACE CONC. CONCEALED FLANGE
STAIR, SEE STRUCT. DWGS
2"
1067 5.5 1-1/2" DIA. ALUM. GUARDRAIL TO 2" X 2" ALUM. TOP RAIL DOCUMENTS & SPECIFICATIONS AS
OPEN GUARD RAILS SHALL HAVE INSTRUMENTS OF SERVICE ARE AND SHALL
EXTEND HORIZONTALLY BEYOND TOP REMAIN THE PROPERTY OF THE ARCHITECT
1-1/2" DIA. ALUM. POST MAX 48" O.C. INTERMEDIATE RAILS OR ORNAMENTAL
OF RISER. WHETHER THE PROJECT THEY ARE MADE
PATTERN SUCH THAT A 4 " (102mm) 3/4" X 3/4" ALUM. PICKETS FOR IS EXECUTED OR NOT. THEY SHALL
1-1/2" DIA. ALUM. BOTTOM RAIL ALUM. HANDRAIL MOUNTING DIAMETER SPHERE CANNOT PASS NOT BE USED BY THE OWNER OR OTHERS
ON OTHER PROJECTS OR FOR ADDITIONS
BRACKET THROUGH ANY OPENING UP TO A HEIGHT TO THIS PROJECT BY OTHERS, EXCEPT BY
AGREEMENT IN WRITING AND WITH
2'-10" HANDRAIL
OF 34". A BOTTOM RAIL OR CURB SHALL BE APPROPRIATE COMPENSATION TO
36"
CONC. LANDING, SEE STRUCT. ALUM. GUARDRAIL MOUNTING PROVIDED THAT WILL REJECT THE THE ARCHITECT.
42" MIN.
2"
DWGS 1'-0" BRACKET MAX 48" O.C. (TYP) PASSAGE OF 2" (51mm) DIAMETER. 4"
2'-10" HANDRAIL
CORE SLAB AND SET POST 2" X 2" ALUM. POST MAX 48" O.C.
3"
COMMENTS
WITH EPOXY NON SHRINK 2" X 2" ALUM. BOTTOM RAIL
GROUT OR QUICK SETTING
2"
CAST IN PLACE ABRASIVE METAL
ANCHOR CEMENT
TREAD NOSING
1'-0"
CONC. SLAB, SEE STRUCT.
2"
DWGS
3"
METAL TREAD NOSING
DATE
WITH EPOXY NON SHRINK
GROUT OR QUICK SETTING
ANCHOR CEMENT
NOTE:
REV NO.
GUARD RAILS OPENINGS: NEW CAST-IN-PLACE CONC. STAIR,
OPEN GUARD RAILS SHALL HAVE INTERMEDIATE RAILS OR SEE STRUCT. DWGS
ORNAMENTAL PATTERN SUCH THAT A 4 " (102mm) DIAMETER NEW CAST-IN-PLACE CONC.
SPHERE CANNOT PASS THROUGH ANY OPENING UP TO A HEIGHT LANDING, SEE STRUCT. DWS
OF 34". A BOTTOM RAIL OR CURB SHALL BE PROVIDED THAT WILL
REJECT THE PASSAGE OF 2" (51mm) DIAMETER.
UPPER LANDING LOWER LANDING
Railing Post Detail at Landings Handrails at Landings Typ. Aluminum Guardrail Section
4 5 6
3"=1'-0" 1"=1'-0" 3"=1'-0"
5050 RESIDENCES
RAILING AT FLIGHT
3'-6" GUARDRAIL
2'-10" HANDRAIL
2'-10" HANDRAIL
4"
4"
4"
3'-6" GUARDRAIL
3'-6" GUARDRAIL
3/4" DIA. ALUM. PICKET AT 4" 1-1/2" DIA. ALUM. VERTICAL FORMED BY THE VERTICAL
MAX. O.C. SUPPORTS AT 44" MAX. O.C. POSTS AND PICKETS
2'-10" HANDRAIL
AS NOTED
04-05-2021
PROJECT NO.: 20-004-00
PEC/JCC
3/4" DIA. ALUM. PICKET AT
DC/PEC
1-1/2" DIA. ALUM. VERTICAL 4" MAX. O.C.
6"
NEW CAST-IN-PLACE CONC.
SUPPORTS AT 44" MAX. O.C.
6" STAIR, SEE STRUCT. DWGS
ISSUE DATE:
LANDING, SEE STRUCT. DWGS
DRAWN BY:
CHECKED:
6" SPHERE SHALL NOT PASS THROUGH
6" SPHERE SHALL NOT PASS THROUGH THE TRIANGULAR OPENING FORMED BY
SCALE:
THE TRIANGULAR OPENING FORMED BY THE TREAD, RISER, AND BOTTOM RAIL
2"
Guardrail Elevation at Landings Stair Section Detail at Landings Stair Section Detail
7 8 9
1"=1'-0" 1"=1'-0" 1"=1'-0" A503