5 Transmitter
Troubleshooting Manual
Document:NHB-NV7.5-NV10-TRB-3.3
Status: Standard
Nautel Limited
10089 Peggy’s Cove Road
Hackett’s Cove, NS Canada B3Z 3J4
Phone: +1.902.823.3900 or
Toll Free: +1.877.6NAUTEL (6628835) (Canada & USA only)
Fax: +1.902.823.3183
Nautel Inc.
201 Target Industrial Circle
Bangor, Maine USA 04401
Phone: +1.207.947.8200
Fax: +1.207.947.3693
Email: support@nautel.com
Web: www.nautel.com
Contents
Page v
NV10/NV7.5 Troubleshooting Manual Table of contents
• Corrective maintenance
• Fan, IPA and Module Power Supply Replacement - see page 1-45
If none of the procedures and alarms described in this section address your problem, contact
Nautel for assistance. See “Technical support” on page ix.
Corrective maintenance
Corrective maintenance procedures consist of identifying and correcting defects or deficiencies
that arise during transmitter operation. Local and/or remote alarm signals are generated when
a malfunction occurs. If an alarm condition is caused by a malfunction in the RF power stage,
the transmitter may maintain operation at a reduced RF output level. The nature of the fault –
and station policy – will dictate whether an immediate maintenance response is necessary.
Fault analysis and rectification may be conducted from three different levels, with a different
technical competence level required for each: on-air troubleshooting, remote or local, and off-
air troubleshooting.
CAUTION:
The transmitter contains many solid state devices that may be damaged if
subjected to excessive heat or high voltage transients. Every effort must be taken
to ensure that circuits are not overdriven or disconnected from their loads while
turned on.
On-air troubleshooting
On-air troubleshooting can be performed from a remote location, or locally at the transmitter
site.
Remote troubleshooting
Remote on-air troubleshooting consists of monitoring the transmitter's radiated signal using an
on-air monitor or via a LAN connection, and observing the status of each remote fault alarm
indicator. Information obtained from these sources should enable an operator to decide
whether an alarm response may be deferred to a more convenient time, an immediate
corrective action must be taken, or if a standby transmitter must be enabled (if one is
available). It is recommended that the significance of remote indications, and the appropriate
responses, be incorporated into a station's standard operating procedures. Refer to “Identifying
an alarm” on page 1-5 to determine the remedial action required for a given fault.
Local troubleshooting
Local on-air troubleshooting consists of monitoring the transmitter's integral meters and fault
alarm indicators. Analysis of this data will normally identify the type of fault, and in most
cases will determine what corrective action must be taken. Refer to “Identifying an alarm” on
page 1-5 to determine the remedial action required for a given fault.
The power amplifier stage contains an integral modular reserve (IMR) feature. This feature
permits the transmitter to operate at a reduced RF output level when a malfunction occurs in
one of its power modules. Station operating procedures will dictate whether a reduced RF
output level is acceptable. When a reduced RF output level can be tolerated, replacement of the
defective RF power module may be deferred to a convenient time.
A defective RF power module may be removed from the transmitter for servicing, while the
transmitter is operating, provided that the conditions in the removal instructions detailed in
“Removing an RF power module” on page 1-32 are met.
Off-air troubleshooting
Off-air troubleshooting must be performed when the replacement of a defective RF power
amplifier module, or routine on-air calibration adjustments, will not restore operation.
NOTE:
Reduce the RF output level to a minimal value when troubleshooting faults in
the power amplifier stage while the transmitter’s RF output is connected to the
antenna system.
Electrostatic protection
The transmitter's assemblies contain semiconductor devices that are susceptible to damage
from electrostatic discharge. The following precautions must be observed when handling an
assembly which contains these devices.
CAUTION:
Electrostatic energy is produced when two insulating materials are rubbed
together. A person wearing rubber-soled shoes, walking across a nylon carpet or a
waxed floor, can generate an extremely large electrostatic charge. This effect is
magnified during periods of low humidity. Semiconductor devices such as
integrated circuits, field-effect transistors, thyristors and Schottky diodes may be
damaged by this high voltage unless adequate precautions are taken.
Handling/Storage
An assembly should be placed in an anti-static bag when it is not installed in a host transmitter,
or when it is not undergoing maintenance. Electronic components should be stored in anti-
static materials.
Tools/Test equipment
Testing and maintenance equipment – including soldering and unsoldering tools – should be
suitable (i.e., grounded tip) for contact with static sensitive semiconductor devices.
Identifying an alarm
The best way to identify an alarm is by viewing the front panel’s Transmitter Status page
(Figure 1.1). If an alarm exists, the Status button at the bottom of the AUI display will be red.
Press or click the Status button to go to the Transmitter Status page.
1. View the list of active faults by pressing the Alarms tab. Alarms are listed by their
origin (Device column), then by name (Alarm column), and then by severity [1 = low
(RF output not affected), 5 = medium (RF output is reduced), 10 = high (RF output is
inhibited); see Level column]. See “List of current alarms” on page 1-6.
2. Attempt to clear any latching alarms by pressing the Reset button on the bottom
banner of the page. If the alarm persists, it will not be cleared from the display.
3. Refer to Table 1.1 on page 1-8 for troubleshooting tips on the offending alarm(s),
which may also reference replacement (see Table 1.2 on page 1-25) and subsequent re-
calibration procedures. Note the origin of the alarm (i.e., contained within Controller,
Exciter, or Module # sub-system folders).
NOTE:
Before undertaking any troubleshooting, record all AUI meter readings and note
if any other alarms are displayed on the Transmitter Status page. Record all
alarms. The most convenient way to do this is by using a web browser over a
LAN connection to save screen shots of critical status, meter and alarm pages.
From the System Review page, press the information (!) button for each sub-
device (Controller, Exciter and Module) to view (and save) detailed information.
Table 1.1 on page 1-8 contains a column for most Alarms that can occur, sorted
alphanumerically for each sub-system. The Description and Troubleshooting Action column
provides a brief description of the alarm, troubleshooting tips and a cross-reference to more
detailed troubleshooting, as applicable.
The AC OK LED indicates the status of the incoming ac source to the supply. The LED is green
when the ac source is at its normal operating level (between 175 and 180 V ac) and off when the
ac source is below an acceptable level or is not present.
The DC OK LED indicates the status of the dc output of the supply. The LED is green when the
dc output is within the adjustable range of its operation limits and off when the dc output is
outside the limits of normal operation.
Exciter LEDs
The front panel of each exciter contains two LEDs that provide specific status and alarm
indications.
The upper LED indicates the status of the exciter’s operating power. The LED is on (green)
when the exciter’s logic supply is enabled and operating at an acceptable level.
The lower LED indicates the RF operating status of the exciter; it has four different
appearances:
Controller: +12V This alarm occurs if the +12 V supply from SBC/AUI power supply A
Supply A (or B) Fault (U1) or B (U2) is outside its acceptable voltage range (between +10.8
and +13.2 V). Use a digital multimeter to measure between +V and -V
of the suspect +12 V supply’s output voltage. If necessary, replace the
+12 V supply (see “+12 V Power Supply Replacement” on page 1-
44). If the alarm persists after replacing the supply, suspect the
control/interface PWB (A1).
Controller: +15V This alarm occurs if the +15 V supply from LVPS module A (U3) or B
Supply A (or B) Fault (U4) is outside its acceptable voltage range (between +13.5 and
+16.5 V). Use a digital multimeter to measure between V2 and COM
of the suspect LVPS output voltage. If necessary, replace the LVPS
(see “LVPS Replacement” on page 1-42). If the alarm persists after
replacing the supply, suspect the control/interface PWB (A1).
Controller: -15V This alarm occurs if the +15 V supply from LVPS module A (U3) or B
Supply A (or B) Fault (U4) is outside its acceptable voltage range (between -13.5 and
-16.5 V). Use a digital multimeter to measure between V3 and COM of
the suspect LVPS output voltage. If necessary, replace the LVPS (see
“LVPS Replacement” on page 1-42). If the alarm persists after
replacing the supply, suspect the control/interface PWB (A1).
Controller: +5V This alarm occurs if the +5 V supply from LVPS module A (U3) or B
Supply A (or B) Fault (U4) is outside its acceptable voltage range (between +4.95 and
+6.05 V). Use a digital multimeter to measure between V1 and COM of
the suspect LVPS output voltage. If necessary, replace the LVPS (see
“LVPS Replacement” on page 1-42). If the alarm persists after
replacing the supply, suspect the control/interface PWB (A1).
Controller: Active This alarm occurs when a system inhibiting fault has occurred within
Exciter Fail the active exciter. The transmitter will be latched off (or changeover to
the standby exciter, if applicable). Check for associated Exciter
prefixed alarm(s) that may have caused the failure and refer to their
troubleshooting action.
Controller: Active This alarm occurs if the active exciter is not responding to serial
Exciter Not messages. Check the integrity of the cable between the exciter’s TX
Responding LINK connector and J5 or J6 (as applicable) of the control/interface
PWB. If the connection is secure, the problem is likely exciter related.
Check for associated Exciter prefixed alarm(s) that may have caused
the failure and refer to their troubleshooting action.
Controller: Check This alarm occurs when a non system inhibiting fault has occurred
Active Exciter within the active exciter. The transmitter will likely resume operation.
Examples of such faults are IBOC data loss, fan failure, high
temperature, or an exciter low voltage power supply rail voltage is out-
of-tolerance. Check for associated Exciter prefixed alarm(s) that may
have caused the failure and refer to their troubleshooting action.
Controller: Combiner This alarm occurs if two or more RF power modules are reporting a
Matching Shutdown Module #: Output Network Shutdown alarm. The transmitter will be
inhibited until a reset occurs. The alarm is indicative of a transmitter
combiner fault. Contact Nautel.
Controller: CPLD This alarm occurs when there is an incompatible software release in
Compatibility Fault the control/interface PWB’s CPLD. Update the software to clear the
fault or contact Nautel.
Controller: Cutback This alarm occurs whenever the transmitter experiences a cutback. A
cutback (reduction in power) occurs when repeated shutback alarms
occur within a prescribed time period. Shutbacks occur when the
transmitter’s peak reflected power exceeds 2:1 (1200 W for all
modes) due to a transient SWR condition (arc or lightning) within the
output transmission line or antenna system. The transmitter shuts
back and recovers to a series of cutback levels (depending on the
severity of the alarm), with each level representing a 1/8th reduction
in power from the preset value. Attempt to reset the latched condition
by pressing Reset. Inspect the output transmission line for punctures
or damage. If no damage can be found, suspect a fault with the
control/interface PWB (A1).
Controller: Disable With one IPA power supply operational, this alarm should not occur.
Module # (1 -16) Check for associated alarm(s) that may have caused the failure and
refer to their troubleshooting action.
Controller: EEP Fail This alarm occurs if there is no valid EEPROM configuration data to
Configuration load. Various parameters will revert back to their failsafe default
values. See “Controller: EEP Fail alarms” on page 1-27.
Controller: EEP Fail This alarm occurs if there is no valid EEPROM meter scale data to
Meter Scales load. All calibrated meter scales will revert back to their failsafe
default values. See “Controller: EEP Fail alarms” on page 1-27.
Controller: EEP Fail This alarm occurs if there is no valid EEPROM module threshold data
Module Thresholds to load. All module threshold values will revert back to their failsafe
default values. See “Controller: EEP Fail alarms” on page 1-27.
Controller: EEP Fail This alarm occurs if there is no valid EEPROM remote data to load.
Remotes All configurable remote input/output settings will revert back to their
failsafe default settings. See “Controller: EEP Fail alarms” on page 1-
27.
Controller: EEP Fail This alarm occurs if there is no valid EEPROM threshold data to load.
Thresholds All controller threshold values will revert back to their failsafe default
values. See “Controller: EEP Fail alarms” on page 1-27.
Controller: Exciter This event is caused by a fault in the active exciter while the
Changeover automatic changeover function is enabled. No further exciter
changeovers can occur until the fault is cleared and the automatic
changeover function is re-armed (using the Changeovers page; refer
to the Operations and Maintenance Manual). Check for associated
alarm(s) that may have caused the changeover and refer to their
troubleshooting action.
Controller: Exciter This alarm occurs when there is an incompatible software release in
Compatibility Fault the exciter. Update the exciter software to clear the fault.
Controller: External This event is caused if the NAPC156 controller experiences a reboot
Watchdog Reset due to assertion of the ATmega2560 CPU's /RESET pin.
Cause The timestamp that appears in the log reflects the instant immediately
AFTER the controller has been released from reset; it does not
attempt to reflect the time at which the failure occurred which
triggered the reset in the first place. If it is an isolated incident, the
event log is merely an indication that the transmitter has successfully
self-healed from whatever triggered the event in the first place. No
action is necessary. If happening repeatedly, then suspect a
hardware failure on the NAPC156 or power supply issues.
Controller: Fan PS A This alarm occurs if fan power supply module A (U7) or B (U8) is
(or B) AC Fail reporting an ac failure, indicating its ac input voltage is less than
175 V ac. Check the ac voltage applied to the suspect fan power
supply module. If the ac voltage is acceptable, replace the fan supply
module (see “Fan, IPA and Module Power Supply Replacement” on
page 1-45).
Controller: Fan PS A This alarm occurs if fan power supply module A (U7) or B (U8) is
(or B) Fail reporting a PS failure, indicating its output voltage is outside of its
acceptable range. The transmitter will inhibit its RFoutput until the
alarm is cleared. Check the dc voltage output of the suspect fan
power supply module. If the dc voltage is out of tolerance, replace the
fan supply module (see “Fan, IPA and Module Power Supply
Replacement” on page 1-45). If the voltage is acceptable, suspect the
control/interface PWB (A1) or interconnect cabling.
Controller: Fan PS A This alarm occurs if fan power supply module A (U7) or B (U8) is
(or B) High Temp reporting a high temperature alarm, indicating its operating
temperature has exceeded its internal threshold. This alarm is most
likely caused by a module fan failure or blockage. Allow the module to
cool and attempt to Reset the alarm. Verify the module turns on and
its fan is operational. If the fan is not operational, inspect it for
possible blockage. If necessary, replace the fan supply module (see
“Fan, IPA and Module Power Supply Replacement” on page 1-45). If
the alarm persist after replacing the module, suspect the control/
interface PWB (A1) or interconnect cabling.
Controller: Fan PS A This alarm occurs if fan power supply module A (U7) or B (U8) is not
(or B) Module Not being detected or has been removed.
Present
Controller: Forward When the High Forward Power alarm is active, this alarm occurs if the
Power Limiting high forward power limiting threshold is exceeded [1.063 times the
maximum power setting for all modes; e.g., 11,693 W (NV10) or 8,770
(NV7.5) for FM mode]. The transmitter will fold back the forward
power each time the threshold is exceeded. This alarm occurs only if
the exciter ALC cannot respond fast enough to transmitter load
changes. Suspect the control/interface PWB (A1).
Controller: Forward This alarm occurs if the transmitter tries to reduce the forward power
Power Shutdown below minimum due to repeated Forward Power Limiting alarms. The
transmitter latches off. See Controller: Forward Power Limiting for
troubleshooting tips.
Controller: High This alarm occurs if the ambient temperature sensed by the control/
Ambient Temperature interface PWB (A1) exceeds 60°C (140°F). Check the intake air
system.
Controller: High This alarm occurs if the transmitter’s average forward power exceeds
Forward Power the high forward power threshold [1.036 times the maximum power
setting for all modes; e.g., 11,396 W (NV10) or 8,547 W (NV7.5) for
FM mode]. This alarm occurs only if the exciter ALC cannot respond
fast enough to transmitter load changes. Suspect the control/interface
PWB (A1).
Controller: High PA This alarm occurs when the calculated average power amplifier
Dissipation dissipation exceeds 200 W.
Controller: High This alarm occurs if the transmitter’s average reflected power
Reflected Power exceeds the high SWR threshold [276 W (NV10 or NV7.5) for FM
mode, 197 W (NV10 or NV7.5) for FM+HD mode, 79 W (NV10 or
NV7.5) for HD mode]. Check for associated alarm(s) that may have
caused the alarm and refer to their troubleshooting action. Inspect the
antenna and transmission line system for damage or de-tuning, else
suspect the control/interface PWB.
Controller: High This alarm occurs if the power in any single reject load exceeds 67%
Reject Power of the reject shutback threshold (default is 1800 W in FM or FM+HD
mode; 900 W in HD mode). The alarm will also occur if the summed
power of reject loads 1/2 or 3/4 exceeds 89% of the reject shutback
threshold, or if the summed power of reject loads 1, 2, 3 and 4
exceeds 133% of the reject shutback threshold. Check for associated
alarm(s) that may have caused the alarm and refer to their
troubleshooting action. This alarm may be accompanied by a Reject
Power Foldback alarm. Typically, high reject power is a result of RF
power module failure or removal. If no other alarms are indicated,
suspect the control/interface PWB.
Controller: High RF This alarm occurs if the active exciter’s power is greater than the high
Drive Power RF drive threshold [55 W for analog (FM) mode and 36 W for hybrid
(FM+HD) and all-digital (HD) mode). Compare the exciter’s
programmed level to its actual output. If a difference exists, there may
be an exciter regulation problem.
Controller: Host This alarm indicates that the microcontroller that runs the remote
Network Down interfacing applications is unable to acquire an IP address. When this
alarm is present, the communication between the LAN controller
(server) and the transmitter server that was once established has now
been lost. It will not be possible to access any of the remote AUI
functionality. Check that the Ethernet cable is properly connected to
A1J8A (LAN) on the rear of the transmitter. If the alarm is still present
see “Setting up the network” on page 2-98 of the Operations and
Maintenance Manual for information on setting up the network
connection. Disable the alarm by setting DHCP to OFF and setting
the IP Address to all zeroes (i.e. 0.0.0.0).
Controller: Injection This alarm indicates a requested injection level for a given analog
Level Over-ridden TPO (licensed power level) cannot be achieved. The transmitter will
automatically reduce the injection level to maintain spectral
compliance.
Controller: Interlock The external interlock input wired to the control/interface PWB (A1) is
Open open. Check the interlock connection between TB2-1 and TB2-2 on
the control/interface PWB (verify a ground potential at TB2-1). If the
interlock is intact, check all external interlock switches. Otherwise,
suspect a problem with the interlock circuitry on the control/interface
PWB.
Controller: IPA High This alarm occurs if there is a failure in one or more IPA power supply
Current Cutback module [A (U9), B (U10)] and the remaining IPA power supply module
is unable to provide the current required by the IPAs. This alarm is
typically accompanied by one or more Controller: Disable Module
alarms. Check the troubleshooting action in the associated alarm(s).
Controller: IPA PS A This alarm occurs if IPA power supply module A (U9) or B (U10) is
(or B) AC Fail reporting an ac failure, indicating its ac input voltage is less than 175
V ac. If a bank of power supply modules are indicating an AC Fail
alarm, it is possible that an ac phase loss has occurred. Check the ac
voltage applied to the suspect IPA power supply module. If the ac
voltage is acceptable, replace the IPA supply module (see “Fan, IPA
and Module Power Supply Replacement” on page 1-45).
Controller: IPA PS A This alarm occurs if IPA power supply module A (U9) or B (U10) is
(or B) Fail reporting a PS failure, indicating its output voltage is less than 40 Vdc.
Check the dc voltage output of the suspect IPA power supply module.
If the dc voltage is out of tolerance, replace the IPA supply module
(see “Fan, IPA and Module Power Supply Replacement” on page 1-
45). If the voltage is acceptable, suspect the control/interface PWB
(A1) or interconnect cabling.
Controller: IPA PS A This alarm occurs if IPA power supply module A (U9) or B (U10) is
(or B) High Temp reporting a high temperature alarm, indicating its operating
temperature has exceeded its internal threshold. This alarm is most
likely caused by a module fan failure or blockage. Allow the module to
cool and attempt to Reset the alarm. Verify the module turns on and
its fan is operational. If the fan is not operational, inspect it for
possible blockage. If necessary, replace the IPA supply module (see
“Fan, IPA and Module Power Supply Replacement” on page 1-45). If
the alarm persist after replacing the module, suspect the control/
interface PWB (A1) or interconnect cabling.
Controller: IPA PS A This alarm occurs if IPA power supply module A (U9) or B (U10) is not
(or B) Module Not being detected or has been removed.
Present
Controller: Low AC This alarm occurs if the ac input voltage is below the switching power
supplies’ internal threshold or one of the phases of a 3-phase source
has been lost. For 1-phase or 208 V ac 3-phase sources the low ac
threshold voltage is 175 V ac. For 400 V ac sources the low ac
threshold voltage is 303 V ac. Check the three amber LEDs (DS1
through DS3) in the bottom, left-hand of the transmitter. If the LEDs
are off, there is likely a problem with the ac service. Measure the ac
source voltage at the service entrance. Normally this should measure
between 180 and 264 V ac line-line [for 3-phase (nominal 208 V ac)
and 1-phase (nominal 230 V ac)] or between 312 and 457 V ac line-
line [for 3-phase (nominal 400 V ac)].
Controller: Low This alarm occurs if the backup battery voltage falls below an
Battery/Memory Fail acceptable level (2.7 V). Check the battery voltage (with ac power
on). If battery voltage is low, replace battery. If battery voltage is OK,
cycle ac power (off, then on). If the alarm does not clear, suspect the
control/interface PWB.
Controller: Low This alarm occurs if the transmitter’s average forward power falls
Forward Power below the low forward power threshold (defaulted to 50% of the
preset power level for all modes) due to module failures, combiner/
filter faults, reject load faults, or SWR foldback. If no other alarms are
being indicated, suspect the control/interface PWB.
Controller: Low Fan This alarm occurs if fan voltage A or B falls below 40 volts. Check the
Volts A (or B) dc voltage output of the suspect fan power supply module (U7 or U8).
If the dc voltage is out of tolerance, replace the fan supply module
(see “Fan, IPA and Module Power Supply Replacement” on page 1-
45).
Controller: Low RF This alarm occurs - in analog (FM) mode only - if the active exciter’s
Drive Power power is less than the low RF drive threshold (18 W). Increase the
exciter output power until the alarm clears. Check RF drive cabling.
Controller: Mode/ This alarm occurs if there is a mismatch between the operating mode
Frequency Mismatch or carrier frequency of the transmitter and one or more of the
associated exciters. Using the AUI verify the active presets of the
transmitter and exciter match. If necessary, set and save the
transmitter’s or exciter’s preset accordingly.
Controller: Module 1 - This alarm occurs if one or more of the RF power modules is not
4 Not Responding responding to serial messages. Try swapping the affected module
with a module in another location (see “Operating with defective or
missing RF power modules” on page 1-30). If the alarm follows the
module, troubleshoot or replace the module. If the alarm follows the
location, check the connections between the module location and its
associated module backplane PWB.
Controller: Module This alarm occurs when the controller has reduced the target power
Failure Foldback level (below the set-point) due to a number of PA or RF module
failures. The desired power level is not achievable with the failures
and reduces the exciter’s output. The amount of foldback is a function
of the number of failures.
Controller: Reject A This alarm occurs if one of the reject load cooling fans (B1 though B3
Fan # (1- 3) Fail in reject load assembly A) is reporting a failure. With RF on, remove
the transmitter’s upper, back panels and check the associated fans
for blockage. If the fan is functioning properly (as compared to
adjacent fans), but the indicated fan speed on the AUI is zero, there
may be a problem with the fan’s tachometer circuitry on the control/
interface PWB. Disconnect the fan’s power plug and verify there is a
nominal 48 V on the plug. If so, replace the fan. If not, suspect a
defective fan power supply module or interconnect cabling. Refer to
Mechanical Drawings for Reject Load and fan locations.
Controller: Reject A This alarm occurs if any of the reject load power samples exceeds its
Power High # (1-8) high reject power threshold (600 W in analog or hybrid mode; 300 W
in all-digital mode). Typically, high reject power is a result of RF power
module failure or removal. If no other alarms are being indicated,
suspect the control/interface PWB.
Controller: Reject This alarm occurs if the transmitter’s reject load’s average power
Power Foldback exceeds its reject power foldback threshold (750 W in analog or
hybrid mode; 375 W in all-digital mode). The transmitter’s forward
power will be reduced each time the alarm occurs, until the fault
clears. Typically, high reject power is a result of RF power module
failure or removal. If no other alarms are being indicated, suspect the
control/interface PWB.
Controller: Reject This alarm occurs if the transmitter tries to reduce the forward power
Power Shutdown below minimum due to repeated Reject Power Foldback alarms. The
transmitter latches off. See Controller: Reject Power Foldback for
troubleshooting tips.
Controller: Residual This alarm occurs if the IPA Volts haven‘t fully discharged and the
IPA Volts transmitter is held in an RF Off state. When the IPA volts fall below
3 V, the alarm will clear and the transmitter will recover.
Controller: Residual This alarm occurs if the PA Volts haven‘t fully discharged and the
PA Volts transmitter is held in an RF Off state. When the PA volts fall below 3 V,
the alarm will clear and the transmitter will recover.
Controller: Restore This alarm occurs if the control/interface PWB was unable to maintain
Status CRC Failure the state of the transmitter through the most recent ac power cycle.
Replace the control/interface PWB’s backup battery (see the Routine
Maintenance section of the Operations and Maintenance Manual). If
battery is OK, cycle ac power (off, then on). If the alarm does not
clear, replace the control/interface PWB.
Controller: SBC This event is caused by the controller failing to receive any
Watchdog Reset communication from the SBC within a prescribed timeframe (default 2
minutes). The controller assumes that a software failure has occurred
on the SBC, and it resets the SBC in an attempt to re-initialize its
software and resume normal operation. Suspect either the SBC or
Controller/Monitor PWB.
Controller: SWR This alarm occurs if the transmitter’s average reflected power
Foldback exceeds the SWR foldback threshold [396 W (NV10 or NV7.5) for FM
mode, 282 W (NV10 or NV7.5) for FM+HD mode, 113 W (NV10 or
NV7.5) for HD mode) due to a gradual degrading load match. Each
time the SWR foldback threshold is exceeded, the transmitter’s
forward power will be reduced until it reaches minimum power,
beyond which the transmitter will shut down. If the load match
improves while the transmitter is producing RF output, the forward
power will increase. Visually inspect the antenna system for ice
buildup and inspect hardline connections. If no problems are found,
suspect the fault detection circuitry on the control/interface PWB (A1).
Controller: SWR This alarm occurs if the transmitter’s peak reflected power exceeds
Shutback the SWR shutback threshold [2:1 SWR, 1200 W (NV10 or NV7.5) due
to a transient SWR condition (arc or lightning) within the output
transmission line or antenna system. Attempt to reset the latched
condition by pressing Reset. Inspect the output transmission line for
punctures or damage. If no damage can be found, suspect a fault with
the control/interface PWB (A1). See also Controller: Cutback alarm.
Controller: SWR This alarm occurs if the transmitter tries to reduce the forward power
Shutdown below 1630 W (NV10 or NV7.5) (FM mode), 1164 W (NV10 or NV7.5)
(FM+HD mode) or 465 W (NV10 or NV7.5) (HD mode) due to
repeated SWR Foldback alarms (equivalent to a 3:1 SWR). The
transmitter latches off. See Controller: SWR Foldback for
troubleshooting tips.
Controller: VDC A (or This alarm occurs if the fan A or B voltage, measured on the power
B) Fan Fail supply distribution PWB (A7), is below the low fan voltage threshold
(40 V). If there is an associated Controller: Fan PS A (or B) Fail alarm,
follow that alarm’s troubleshooting action. Verify the voltage on TP1
(A) or TP2 (B) of the power supply distribution PWB. If the voltage is
low, check the connections between the fan power supply module, its
PS interface PWB and the power supply distribution PWB. If it is OK,
suspect the control/interface PWB (A1).
Controller: Very Low This alarm occurs if transmitter’s average forward power falls below
Forward Power the low forward power threshold (defaulted to 25% of the preset
power level for all modes) due to module failures, combiner/filter
faults, reject load faults, or SWR foldback. If no other alarms are
being indicated, suspect the control/interface PWB.
Controller: Watchdog This alarm occurs if the Single Board Computer (SBC) loses
Asserted communication with the controller for over 2 minutes. The controller
reboots the SBC in an attempt to re-establish communication.
Exciter A/B: Audio This alarm occurs if the exciter’s audio processing and FM
Shutdown modulation code is shut down. Should display only during a software
upgrade.
Exciter A/B: Analog This alarm indicates the analog left or right audio input level is too low
Left (or Right) Low (default threshold is 22.5 dB below full scale) or is not applied.
Exciter A/B: This alarm indicates the composite audio input level is too low (default
Composite Low threshold is 22.5 dB below full scale).
Exciter A/B: Dead Air This alarm indicates that the exciter’s audio modulation level is below
the level specified in the dead air settings of the active preset. Check
the appropriate program input(s) and the dead air setting for the
preset.
Exciter A/B: Digital 1 This alarm indicates the corresponding digital input level is too low
(or 2) Low (default threshold is 22.5 dB below full scale). Typically accompanied
by a Primary (or Secondary) Digital SRC Unlock alarm (see
associated troubleshooting action). If no accompanying SRC alarm
exists, check the external audio processor or studio feed.
Exciter A/B: Entered This alarm occurs when the exciter is in “firmware upgrade” mode. It
Firmware Upgrade should only be displayed during a transmitter software upgrade.
Exciter A/B: Exgine This alarm occurs, in FM+HD or HD mode, when the exciter is initally
Not Booted powered up, but the Exgine PWB (A3) has not finshed its boot-up
sequence. Normally, the alarm will clear on its own. If not, suspect a
defective Exgine PWB.
Exciter A/B: Exgine This alarm occurs, in FM+HD or HD mode, when the exciter is not
Offline communicating with the Exgine PWB (A3). Check the ribbon cable
between the Exgine PWB (A3) and J15 of the NVE exciter PWB (A1).
Check the Exgine PWB.
Exciter A/B: External This alarm occurs if a ground potential is applied to pin 7 of connector
Mute A1J4A or pin 1 of connector A1J7A on the exciter’s back panel. The
exciter’s RF output is reduced to 0 W.
Exciter A/B: Fan Fail This alarm occurs if the exciter’s cooling fan (B1) speed is too low.
This alarm does not directly inhibit the exciter’s RF output, but may
result in a PA Over Temperature alarm, which will inhibit the output.
Inspect the fan for a possible blockage.
Exciter A/B: FPGA There was a programming failure with the initial startup sequence of
Test Failed the NVE exciter PWB (A1). Possibly indicates a failed software
upgrade or a hardware failure on the NVE exciter PWB.
Exciter A/B: Invalid This alarms occurs, in FM+HD or HD mode, if IBOC data is detected
HD Data from the Exgine PWB, but is not usable (all logic 0s). Digital carriers
are muted. Check the IBOC data source.
Exciter A/B: IPA Volts This alarm indicates the first-stage amplifier’s PA voltage is outside its
Fail acceptable range of 24.3 to 29.7 V. Check the exciter’s power supply
(U3).
Exciter A/B: Low This alarm occurs if the backup battery voltage falls below an
Backup Battery acceptable level (2.7 V). Check the battery voltage. If battery voltage
is low, replace battery. If battery voltage is OK, cycle ac power (off,
then on). If the alarm does not clear, suspect the NVE exciter PWB.
Exciter A/B: Missing This alarm occurs if the transmitter has not sent a preset configuration
External Preset to the exciter. Can occur of the exciter has been power-cycled, but the
transmitter has not, in which case the alarm should clear on its own. If
the alarm persists, contact Nautel.
Exciter A/B: Need This alarm indicates that NVE setup changes have been made,
Reboot For Settings typically via the Hardware Configuration page of the AUI. Cycle (turn
off, then on) the power to the exciter to store the changes.
Exciter A/B: No This alarms occurs, in the transmitter log only, if no external or Exgine
Active 10 MHz 10 MHz clock is being detected. If the alarm persists, the exciter may
have experienced a TCXO failure or an improperly installed OCXO
upgrade.
Exciter A/B: No Ext This alarms occurs if no external 10 MHz is detected. Check the
10 MHz 10 MHz input.
Exciter A/B: No HD This alarms occurs, in FM+HD or HD mode, if IBOC data is not
Data detected from the Exgine PWB. Digital carriers are muted. Verify the
RJ45 cable between the Exgine PWB (A3) and J11 of the NVE exciter
PWB (A1) is seated properly. Check that the Exgine PWB is correctly
powered up.
Exciter A/B: No This alarm indicates the RF sample from the transmitter output is
Reverse Path below a preset threshold. The pre-correction function will not operate.
Exciter A/B: No This alarm, which is only displayed as a log entry, occurs if the
Transmitter Comms transmitter is not communicating with the exciter. Check the
transmitter link cable.
Exciter A/B: No 1PPS This alarm occurs if the pilot output locking to 1 PPS is enabled and
the 1 PPS signal is not present.
Exciter A/B: PA Over This alarm occurs if the temperature sensed within the exciter’s RF
Temperature power stage exceeds 70°C (158°F). The exciter’s RF output is
reduced to 0 W. Check the exciter fan’s air path.
Exciter A/B: PA Volts This alarm indicates the second-stage amplifier’s PA voltage is
Fail outside its acceptable range of 40.5 to 49.5 V. Check the exciter’s
power supply (U3).
Exciter A/B: Pilot This alarm occurs if there is no synchronization between the 10 MHz
Unsync and 1PPS signals. It may indicate that the GPS receiver is not
detecting a signal. Check the GPS receiver and antenna.
Exciter A/B: PLL This alarm indicates that the exciter’s master clock is not locked
Unlock Possible causes are an out-of-range 10 MHz input or a hardware
failure on the NVE exciter PWB (A1).
Exciter A/B: Primary This alarm indicate that no valid AES/EBU or SPDIF stream data is
Digital SRC Unlock being detected on the selected AES/EBU. Check cable connections
and verify the primary input assignments are set correctly in the
Hardware Configuration page of the AUI.
Exciter A/B: SCA 1 This alarm indicates the SCA 1 or 2 input level is too low (default
(or 2) Low threshold is 22.5 dB below full scale) or is not applied.
Exciter A/B: This alarm indicate that no valid AES/EBU or SPDIF stream data is
Secondary Digital being detected on the selected AES/EBU. Check cable connections
SRC Unlock and verify the primary input assignments are set correctly in the
Hardware Configuration page of the AUI.
Exciter A/B: SWR This alarm occurs if the exciter’s peak reflected power exceeds 30 W
Shutback due to a transient SWR condition. The exciter’s RF output is
temporarily reduced to 0 W. Typically caused by a severe mismatch
(open or short circuit) at the exciter’s RF output. Check the RF load at
the exciter’s output.
Exciter A/B: This alarm indicates that the exciter is operating with ‘unsigned code’,
Unsigned DSP Image but is otherwise operational. This alarm may only be displayed if the
transmitter is operating with a ‘beta’ version of factory software.
Exciter A/B: This alarm indicates that the exciter is operating with ‘unsigned code’,
Unsigned FPGA but is otherwise operational. This alarm may only be displayed if the
Image transmitter is operating with a ‘beta’ version of factory software.
Exciter A/B: +15V This alarm occurs if the associated low voltage dc supply is 10% high
Fail, -15V Fail, +5V or 10% low.
Fail, +3.3V Fail,
+1.8V Fail, +1.2V Fail
Module #: Alarm Fan (Module LED = red) This alarm occurs if two or more fans fail while
Inhibit the module is operating. Module PAs and IPA are inhibited. Requires
a reset from the AUI.
Module #: External (Module LED = red) This alarm occurs if the module receives an
Inhibit Serial inhibit message serially from the controller. The controller may inhibit
modules for various reasons.
Module #: External (Module LED = red) This alarm occurs if the module’s front panel
Inhibit Switch switch is in the ‘down’ position. Set the switch to its ‘up’ position and
initiate a reset via the AUI to enable the module.
Module #: Fan 1-6 (Module LED = green/red) This alarm occurs if the speed of one of
Fail the associate module’s cooling fans is below 3000 RPM (half its
nominal value of 6000 RPM). Inspect the affected fan and, if
necessary, replace it (see “Module cooling fan replacement” on
page 1-40).
Module #: Heatsink (Module LED = red) The heatsink temperature of the module has
Temp Inhibit exceeded the AUI adjustable threshold. The module will be inhibited
and requires a Reset from the AUI to re-enable. If this alarm is
accompanied by another alarm, troubleshoot the other alarm first. If
the alarm occurs on its own, see “Troubleshooting RF power
modules” on page 1-36 to determine whether to replace the affected
module or to repair damaged parts.
Module #: IPA (Module LED = green/red) This alarm occurs if the IPA PA’s peak
Forward High forward power is greater than the AUI adjustable threshold for the
operating mode and frequency. The module will continue to operate
unless the IPA’s peak forward power exceeds the IPA Forward
Shutdown threshold, which is 10 W greater than the IPA Forward High
threshold.
Module #: IPA (Module LED = green/red) This alarm occurs if the IPA PA’s peak
Forward Low forward power is less than the AUI adjustable threshold for the
operating mode. The module will continue to operate.
Module #: IPA (Module LED = red) This alarm occurs if the IPA’s peak forward power
Forward Shutdown exceeds the AUI adjustable IPA Forward High threshold for the
operating mode and frequency by more than 10 W. The module will
be inhibited.
Module #: IPA Input (Module LED = green/red) This alarm occurs if the input RF drive
High (exciter power) is greater than the AUI adjustable high IPA input
threshold for the operating mode. This alarm occurs if the exciter ALC
cannot respond quickly enough to varying exciter load changes or if
the exciter’s output has increased or been incorrectly set to a very
high level.
Module #: IPA Input (Module LED = green/red) This alarm occurs if the input RF drive
Low (exciter power) is less than the AUI adjustable low IPA input threshold
for the operating mode. This may be the result of an exciter fault,
excessive load variation on the active exciter output, or defective
components on the RF drive splitter/changeover assembly.
Module #: Module (Module LED = green/red) There is no valid EEPROM data to load.
EEP Fault See “Operating with defective or missing RF power modules” on
page 1-30 to replace the affected module.
Module #: No Front (Module LED = red/amber) The module has not received any serial
Panel messages from the Controller for more than 2.5 seconds. This alarm
is only displayed as a log entry for the applicable module.
Module #: Output This alarm occurs if the ratio of the highest PA 1 to 4 current versus
Network Shutdown the highest PA 5 to 8 current exceeds 3.5:1. This indicates that the
module is operating into a high VSWR due to a transient arc or
combiner failure.
Module #: PA 1-8 (Module LED = green/red) Due to other failures within the module, the
DSBL PA has been disabled to limit reject power in the module. Check for
associated alarm(s) that may have caused the failure and refer to
their troubleshooting action.
Module #: PA 1-8 Fail (Module LED = green/red) This alarm occurs if the dc input current for
the suspect PA has fallen below a preset threshold (typically less than
50% of the average PA current of the operational PAs). This may be
caused by a cabling fault on the PA, loss of PA voltage or bias, or a
defective FET. The transmitter’s output power may be reduced.
Module #: PS 1 (or 2) (Module LED = green/red or amber) This alarm occurs if one of the
AC Fail two module power supplies (1 or 2) is reporting an ac failure,
indicating its ac input voltage is less than 175 V ac. If a bank of power
supply modules are indicating an AC Fail alarm, it is possible that an
ac phase loss has occurred. Check the ac voltage applied to the
suspect power supply module. If the ac voltage is acceptable, replace
the module (see “Fan, IPA and Module Power Supply Replacement”
on page 1-45).
Module #: PS 1 (or 2) (Module LED = green/red or amber) This alarm occurs if one of the
Fail two module power supplies (1 or 2) is reporting a PS failure, indicating
its output voltage is outside its acceptable range, based on the control
setting. Check the dc voltage output of the suspect power supply
module. If the dc voltage is out of tolerance, replace the power supply
module (see “Fan, IPA and Module Power Supply Replacement” on
page 1-45). If the voltage is acceptable, suspect the control/interface
PWB (A1) or interconnect cabling.
Module #: PS 1 (or 2) (Module LED = green/red or amber) This alarm occurs if one of the
High Temp two module power supplies (1 or 2) is reporting a high temperature
alarm, indicating its operating temperature has exceeded its internal
threshold. The affected power supply is latched off while this fault
exists. A manual reset is required to clear the alarm and restore the
power supply to operation. This alarm is most likely caused by a
module fan failure or blockage. Temporarily pull out the power supply
module. After a few minutes, re-insert the power supply module and
attempt to Reset the alarm. Verify the power supply module turns on
and its fan is operational. If the fan is not operational, inspect it for
possible blockage. If necessary, replace the power supply module
(see “Fan, IPA and Module Power Supply Replacement” on page 1-
45). If the alarm persists after replacing the power supply module,
suspect the control/interface PWB (A1) or interconnect cabling.
Module #: PS 1 (or 2) (Module LED = green/red or amber) This alarm occurs if one of the
Not Present two module power supplies (1 or 2) is not being detected or has been
removed.
Module #: Power Up (Module LED = red) The associated module has just been installed or
Inhibit dc power has just been restored. The module will be inhibited until a
reset is received from the AUI.
Troubleshooting tips
AUI screen lockup
If the local AUI screen locks up, try the following to restore normal AUI operation:
1. At the transmitter, press the Nautel logo icon in the upper, left corner of the local AUI
screen. This should reload the AUI and return you to the login screen. Enter your
username and password and continue operation. If this does not restore operation of
the local AUI, proceed to Step 2.
2. If you also use a PC for remote AUI control/monitoring of the transmitter, use the PC
to navigate to the System Settings page (from the Menu options). Select Reset and
click the Reboot AUI button. If this does not restore operation of the local AUI,
proceed to Step 3.
In the case of the Controller: EEP Fail Configuration alarm, the following parameters will revert
to the indicated failsafe default states:
In the case of the Controller: EEP Fail Meter Scales alarm, all calibrated meter scales will revert
to their failsafe default values.
In the case of the Controller: EEP Fail Module Thresholds alarm, all module thresholds will
revert to their failsafe default values.
In the case of the Controller: EEP Fail Remotes alarm, all configurable remote input and output
lines on J23 and J24 of the control/interface PWB will revert to their failsafe default values.
In the case of the Controller: EEP Fail Thresholds alarm, all controller thresholds will revert to
their failsafe default values.
1. Using the front panel AUI’s Hardware Configuration page, confirm the associated
alarm by verifying the parameters have reverted to their failsafe default states. Use the
list above to verify a Controller: EEP Fail Configuration alarm.
2. Attempt to reset the alarm by resetting one of the defaulted parameters to its desired
value or state. Even if no parameter requires resetting, it is necessary to re-write at least
one parameter. Press Apply in the applicable AUI screen.
3. Cycle the ac power (switch off ac power, then switch back on).
4. If the Controller: EEP Fail alarm persists, suspect the control/interface PWB (A1) and if
necessary, replace it (see “Control/interface PWB replacement” on page 1-40).
1. Check the forward power reading on the AUI. If it is less than the preset level, one or
more RF power modules are defective. Proceed to “RF power module fault validation”
on page 1-29.
2. If the forward power reading in Step 1 is normal press the Transmitter Status button
on the AUI to check for other alarms that may have triggered the RF power module
alarm.
3. From the AUI’s System Review page, click the i (information) button to view the RF
Modules status screen (see Figure 1.2 on page 1-29). This screen displays critical
parameters for all 4 RF power modules. As an aid in troubleshooting, compare
parameters to isolate possible module faults.
Identify and isolate a defective RF power module, and verify the nature of the defect by
checking the LED on the RF power module’s front panel. Note which RF power module is
not operating normally and producing RF power (i.e., LED is not solid green). Record which
RF power modules are displaying an alarm and the state of its LED (see below).
For all Module alarms, the Description and Troubleshooting Action column of Table 1.1 on
page 1-8 includes the expected LED colour for the AUI alarm being described.
Attempt to reset an RF power module by pressing Reset on the AUI screen. If you cannot
reset the front panel LED alarm, see “RF power module troubleshooting”.
NOTE:
A defective RF power module can be removed for repair, without turning off the
transmitter, as described in “Removing an RF power module” on page 1-32. The
transmitter can be operated at a reduced output power level with an RF power
module removed.
If you have purchased the RF power module extension test jig (Nautel Part # 206-5350), you
can use it to test and troubleshoot RF power modules before returning them to service. Refer
to “Using the RF power module extension test jig” on page 1-34 for more information.
CAUTION:
Do not attempt to compensate for power reduction caused by an RF power
module failure by adjusting the RF power level.
• If an RF power module has one or more defective PAs, as indicated by the AUI's RF
Modules Status screen (and suspect RF power module's front panel LEDs), but is still
contributing to the transmitter's RF output, it may be left on. The transmitter will
take necessary precautions to reduce the stress on components due to the failure, i.e.,
power reduction.
• If an RF power module must be removed, turn it off prior to disengaging its blind-mat-
ing connectors. Refer to “Removing and reinstalling RF power modules” on page 1-32
to disable a module with the transmitter on air. At all other times, turn off the switch-
ing power supplies by pressing the RF Off button, then switch off the ac power source
at the service entrance.
NOTE:
There are many possible combinations of PA/module failures or extractions.
The best and worst case situations are shown in Table 1.3.
• When maintenance is complete and it is safe to return the transmitter to normal ser-
vice, enable all RF power module supplies by setting the switch on the front of the
associated RF power module(s) to its ‘up’ position.
RF Output Power
PA/Module Failures/Removal (% of rated power **)
2. Set the switch on the front of the RF power module to its ‘down’ position. This
inhibits the module’s associated pair of power supply modules.
3. Remove the two M5 securing screws in the front of the module. If necessary, remove
the two M8 shipping screws in the back of the module (the shipping screws do not
need to be reinstalled, and may have already been removed during installation or
previous maintenance).
WARNING:
Rotating parts are present at the bottom of the RF power module. Take
care when removing the module.
4. Grasp the handle on the front of the RF power module and carefully pull the RF
power module out of the transmitter. The module weighs 17 kg (38 lbs).
2. Carefully push the RF power module into place so that its card-edge connector mates
with the transmitter.
4. Set the switch on the front of the RF power module to its ‘up’ position.
5. Press the Reset button on the AUI to enable the RF power module and its two
associated power supplies.
1 2 3 4
Enable/Disable
Switch
WARNING:
Dangerous RF and dc voltages are exposed when an RF power
module’s cover is removed. Use extreme caution when
troubleshooting an RF power module. Nautel highly recommends
that you contact a customer service representative before attempting
to troubleshoot an RF power module.
NOTE:
The test jig must be inserted into a vacant RF power module position. If
necessary, remove an RF power module as detailed in “Removing an RF power
module” on page 1-32. Due to its physical design, the test jig can not be mounted
in certain cabinet-edge module positions. For the NV10/NV7.5 transmitter, the
test jig can not be used in module positions 1 or 4. Nautel recommends using the
test jig in module position 2. Swap RF power modules, as necessary, to move the
suspect module to position 2.
1. Remove or verify an RF power module has been removed to allow insertion of the test
jig (see “Removing an RF power module” on page 1-32). See above NOTE for
restrictions.
2. Obtain the NV extension module (Nautel Part # NAX249). Carefully push the NV
extension module into the vacant module position so that its card-edge connector
mates with the transmitter. Note that the end of the extension module that has
protruding 7/16” DIN and card-edge connectors is the end that inserts into the
transmitter.
Figure 1.4: Testing an RF Power Module with the NV Power Module Extension Test Jig
NV EXTENSION MODULE
(INSERTED IN MODULE POSITION)
4. Obtain the NV module extension support (Nautel Part # 206-5330). Install the
extension support at the front of the transmitter as shown in Figure 1.4. Secure the
extension support using two M5 screws, which are pre-existing on adjacent modules
(e.g., modules 1 and 3). Install, but do not tighten the screws at this time.
5. Obtain the RF power module to be tested. Remove the RF power module’s right-hand
side cover and, using four M4 screws from the cover, install the module cover runner
(Nautel Part # 206-5355) at the bottom of the module’s open side. The runner provides
added mechanical stability for the module under test while its cover is removed.
6. Carefully push the RF power module into the module extension support so that its
card-edge connector mates with the NV extension module. Firmly tighten the screws
that were installed in Step 4.
7. Set the switch on the front of the RF power module to its ‘up’ (enabled) position.
8. Press the Reset button on the AUI to enable the RF power module and its two
associated power supplies. Test or troubleshoot the RF power module as desired.
9. Reverse the steps in this procedure to remove the RF power module extension test jig
and return the RF power module to the transmitter cabinet. Press the Reset button on
the AUI to return the RF power module to service.
• Digital multimeter
Electrostatic Precautions
The RF power module contains semiconductor devices that are susceptible to damage from
electrostatic discharge. Be sure to follow the electrostatic precautions in “Electrostatic
protection” on page 1-3 at all times.
3. Based on the AUI alarm that prompted RF power module troubleshooting, replace
either the defective PA PWB (see “PA PWB replacement” on page 1-37) or defective
cooling fan. (see ).
NOTE:
If a failure occurs, you must replace the entire power amplifier PWB, rather than
an individual FET. A spare power amplifier PWB (NAPA20A) is provided in
the transmitter station spares kit, if purchased. To order a station spares kit
contact Nautel. Failure to observe this recommendation may void your
equipment warranty or cause further failures.
PA PWB replacement
See Figure MD-14 in the Mechanical Drawings section (Section 6) of this manual.
1. Unsolder and remove the four solder connections to the PA PWB. They include a
white, 22 AWG wire (to pad A), a white, 16 AWG wire (to pad B) and two tinned
copper jumpers (to pads C and F).
2. Remove the two #4 screws, split and flat washers securing the FET to the heat sink.
3. Remove the six M3 screws securing the PA PWB to the heat sink.
4. Obtain the replacement NAPA20A PA PWB from the station spares kit, if purchased.
As applicable, retain the PA Bias Volts Data sheet provided with the replacement PA
PWB.
NOTE:
FETs are static sensitive and must be handled in a static protected manner.
5. Spread a small amount of thermal compound (Nautel Part # HAG39, from the station
spares kit), thinly and evenly, on the bottom of the FET flange on the new PA PWB.
6. Secure the PA PWB on the module's heat sink using the six screws removed in Step 3.
Ensure correct orientation (same as the adjacent PWB). Do not tighten the six screws
at this time.
7. Secure the FET (Q1) with two # 4 screws, a flat washer and a new split washer.
NOTE:
You can damage the FET case if you fully tighten one screw while the other is
loose. Try to alternate tightening of the two screws to prevent this.
8. Using a torque screwdriver, tighten the screws to 6 inch pounds (0.672 Newton-
meters).
11. Return the RF power module to the transmitter (see “Installing an RF power module”
on page 1-32).
12. If you experience any reject load related alarms, it is possible that the replacement PA
PWB requires a change to its bias setting. A PA’s bias setting acts to balance the PA
output power levels based on different FET characteristics. If this occurs, perform the
“PA Biasing Procedure” on page 1-39.
PA Biasing Procedure
This procedure (see Figure 1.5) allows the user to easily set the applicable bias values from the
control tag provided with the replacement PA.
Select which RF Module and PA position the replacement PA was installed in, then enter the
Bias Values for indices 1 through 5 from the factory supplied control tag. Select “Apply” to
save the new Bias Value (s).
NOTE:
The Bias Values fields accept only a decimal number format. Enter the decimal
number from the control tag, or if your spare PA control tag specifies a
hexadecimal number, convert it to decimal and then enter the appropriate
decimal number.
1. Disconnect the suspect cooling fan’s mating plug (B1P1 through B6P1).
2. Remove and retain the cooling fan’s two M3 captive screws that secure the fan to the
module.
3. Obtain a replacement fan (Nautel Part # ZAP50) from the site spares kit, if purchased
or a suitable equivalent (vendor part # is Minebea Motor Mfg. Corp. 3115RL-07W-B79-
E51).
5. Return the RF power module to the transmitter (see “Installing an RF power module”
on page 1-32).
NOTE:
If the transmitter is operating with NV SW 4.3 or later, any existing presets will
be transferred to the new PWB from the exciter. For single exciter systems with
software older than 4.3, the customer will have to enter any preset information.
The customer’s calibration data and Remote I/O configuration settings will not
need to be entered if the EEPROM file is transferred from the old PWB to the
new one. If the NAPC156* PWB’s EEPROM was not saved to the new PWB,
navigate to the local or remote AUI’s Menu -> Factory Settings -> Scaling
page. Record the scale values for RF Drive Power, Forward Power and Reflected
Power. These values will be required later to configure the replacement Control/
Interface PWB.
1. Switch off (and lock out if possible) ac power at the service entrance. Open the front
door to gain access to the control/interface PWB (A1).
2. Remove all interconnecting plugs and wiring from the control/interface PWB. Note
the destination of each wire/connector (refer to Section 4, “Wiring/connector lists” on
page 4-1 to locate wiring and connector mating tables).
3. Remove and retain the 10 sets of mounting hardware from the control/interface PWB.
4. Pull the control/interface PWB away from the remote interface PWB (A2). It may be
helpful to gently pry the connector loose with a screwdriver.
5. Set all jumpers on the replacement PWB to the same positions as the defective PWB.
7. Reconnect all mating connectors and wiring to the new control/interface PWB and
turn on ac power to transmitter.
NOTE:
The NV’s Transmitter Type can only be set from the local AUI.
8. Navigate to the local AUI’s Menu -> Factory Settings -> Transmitter Type. Select
the appropriate transmitter type (eg. NV5) and press Apply.
NOTE:
The following settings are not affected when the NAPC156* PWB is replaced:
Logs, User Settings, Network Setup, Email Config, Notifiactions, SNMP Config,
and Scheduler settings.
9. If applicable, navigate to the local or remote AUI’s Menu -> Factory Settings ->
Scaling page. Enter the scale values for RF Drive Power, Forward Power and
Reflected Power recorded earler. Press Apply to save the changes.
1. Open the front door to gain access to the remote interface PWB (A2).
2. Remove all customer interface wiring from the remote interface PWB. Note the
destination of each wire for ease of reconnecting.
3. Remove and retain six sets of mounting hardware from the remote interface PWB.
4. Pull the remote interface PWB away from the control/interface PWB (A1). It may be
helpful to gently pry the connector loose with a screwdriver.
5. Set the STATUS and ALARM jumpers as well as jumpers E1 through E24 on the new
remote interface PWB to the same positions as the defective PWB.
6. Use an indelible marker to identify the LED and switch labels on the new remote
interface PWB to match the labels on the defective PWB.
LVPS Replacement
WARNING:
Lethal voltages exist inside the transmitter when the power is turned
on. Follow replacement instructions carefully to ensure safety for
maintenance personnel during power supply replacement.
See Figure 1.6 on page 1-43 and Figures MD-2 and MD-7 in the Mechanical Drawings section
(Section 6) of this manual.
1. Open the front door and remove the blank panel to the right of the RF power
modules. Retain hardware and locate the suspect LVPS module [U3 (A) or U4 (B)].
2. Temporarily disconnect ac power from the suspect LVPS module by disconnecting the
appropriate ac plug from the ac distribution assembly (A6). Disconnect P3 from A6J3
for LVPS module A (U3). Disconnect P6 from A6J7 for LVPS module B (U4). The
LVPS module’s green lamp should turn off. Verify ac power has been disconnected
from the LVPS module by using a digital voltmeter to verify 0 V between the L and
ground terminals and between the N and ground terminals.
3. Disconnect all wiring from the LVPS module’s terminal block, noting the specific
destination of each wire.
4. Using a 4 mm hex key (not provided), loosen the two M5 cap screws securing the
LVPS module to the transmitter. Remove the LVPS module and its mounting plate
from the transmitter.
5. Remove the two M4 screws that secure the LVPS module to its mounting plate.
6. Locate or obtain a replacement LVPS module (Nautel Part # UG68). Reverse Step 1
and Step 5 to reinstall the new LVPS module. If necessary, refer to Section 4, “Wiring/
connector lists” on page 4-1 to locate wiring details.
7. From the AUI’s System Review page, select Controller and view the +5V A or +5 V B
meter, depending on which LVPS module was replaced. If necessary, adjust the
potentiometer on the rear of the LVPS module until the meter reading is 5.6 V.
8. The transmitter should resume normal operation and the alarm should clear.
Rear
See Figure 1.6 on page 1-43 and Figures MD-2 and MD-7 in the Mechanical Drawings section
(Section 6) of this manual.
1. Open the front door and remove the blank panel to the right of the RF power
modules. Retain hardware and locate the suspect +12 V power supply module [U1 (A)
or U2 (B)].
2. Temporarily disconnect ac power from the suspect +12 V power supply module by
disconnecting the appropriate ac plug from the ac distribution assembly (A6).
Disconnect P2 from A6J2 for +12 V power supply module A (U1). Disconnect P5
from A6J6 for +12 V power supply module B (U2). The +12 V power supply
module’s green lamp should turn off. Verify ac power has been disconnected from the
+12 V power supply module by using a digital voltmeter to verify 0 V between the L
and ground terminals and between the N and ground terminals.
3. Disconnect all wiring from the +12 V power supply module’s terminal block, noting
the specific destination of each wire.
4. Using a 4 mm hex key (not provided), loosen the two M5 cap screws securing the +12
V power supply module to the transmitter. Remove the +12 V power supply module
and its mounting plate from the transmitter.
5. Remove the two M4 screws that secure the +12 V power supply module to its
mounting plate.
6. Locate or obtain a replacement +12 V power supply module (Nautel Part # UG57).
Reverse Step 1 and Step 5 to reinstall the new +12 V power supply module. If
necessary, refer to Section 4, “Wiring/connector lists” on page 4-1 to locate wiring
details.
7. From the AUI’s System Review page, select Controller and view the +12V A or +12 V B
meter, depending on which +12 V module was replaced. If necessary, adjust the
potentiometer on the rear of the +12 V module until the meter reading is 12.6 V.
8. The transmitter should resume normal operation and the alarm should clear.
1A 3A
1B 3B
2A 4A
2B 4B
Fan Power Fan Power
Supply Module A Supply Module B
IPA Power IPA Power
Supply A Supply B
1. Open the front door and locate the suspect power supply module. See Figure 1.7.
WARNING:
Rotating parts are present at the back of the power supply module.
Take care when removing the module.
2. From the front of the transmitter, remove the power supply module from the
transmitter. If necessary, use a slotted screwdriver to turn the LATCH knob at the front
of the power supply module counterclockwise to unlatch the module from its support
bracket.
3. Locate or obtain a replacement power supply module (Nautel Part # UG69). Reverse
Step 1 through Step 2 to reinstall the new power supply module. The transmitter
should resume normal operation and the alarm should clear.
4. If you have purchased the power supply extension assembly (Nautel Part # 206-5750),
you can use it to bench test and troubleshoot power supplies before returning them to
service. Refer to “Using the power supply extension assembly” on page 1-46 for more
information.
WARNING:
Lethal voltages exist inside the power supply module when power is
applied or had recently been applied (within 10 minutes). Opening the
power supply module to troubleshoot will void your warranty.
Contact Nautel before attempting to troubleshoot a power supply
module.
The assembly consists of three parts, which are pre-connected for customer convenience:
1. Remove or verify a power supply has been removed to allow insertion of the power
supply extension assembly.
3. Carefully push the power supply extension module end (A1) of the assembly into the
vacant power supply position so that its card-edge connector mates with the
transmitter. No securing hardware is required.
4. Place the power supply support end (A2) of the assembly on a suitable test surface that
is less than 15 feet (4.5 m) from the transmitter. The power supply support contains
holes to allow mounting to the test surface, but it is not necessary.
5. Carefully push the power supply to be tested along the runners of the power supply
support so that its card-edge connector mates with the support.
7. Reverse the steps in this procedure to remove the power supply extension assembly
and return the power supply to the transmitter cabinet.
U6W1P1
(mates with COM2) W17P2 U5-VGA W15P2 CARD
red stripe bottom; (mates (mates (mates (U5)
leave top 4 pins of with with with
COM2 open COM1) VGA) J1)
(U6W1P2 mates
with W16P2)
2. Open the front door and locate the single-board computer (SBC) on the back of the
door.
3. Disconnect all connectors from the current SBC. See Figure 1.8 on page 1-48 for
details. Remove the SBC from the front door by removing its four M3 securing screws.
NOTE:
It is recommended to reuse the original Compact Flash card. This saves re-
entering all the CF card related saved content. Ensure the Compact Flash card
has latest software available.
4. Locate or obtain the replacement SBC (Nautel Part # 206-8973). If the replacment SBC
does not contain a card (U5) (see Figure 1.8 on page 1-48), obtain the card from the
SBC removed in Step 3 and insert it into the replacement SBC.
5. Install the replacement SBC using its four M3 securing screws. Use Figure 1.8 on page
1-48 to reconnect all mating connectors. Pay particular attention to ribbon cable
connectors U6W1P1 and U6W2P1, which have specific connection requirements.
7. From the AUI’s Software Configuration page, select Upgrade Software and view the
files in the Select A Boot Image list. These are the files on the card. Select the latest
version of software from the list (e.g., V2_7) and press the About button. Information
about the transmitter device’s current software versions and the selected upgrade file
should appear (see Figure 1.9 on page 1-50).
8. For each device shown in Figure 1.9 on page 1-50, compare the Current Version
column with the Upgrade Version column. If the Upgrade Version value is a higher
number, an upgrade is available for that device from the selected software upgrade file.
If desired, close the Upgrade Information screen and upgrade the software by pressing
Begin.
NOTE:
Pressing Begin initiates the software upgrade process. Contact Nautel if you are
unsure if you should perform a software upgrade.
For more details on performing a software upgrade, refer to the “Upgrading
software” procedure in Section 4, “Non-standard maintenance” on page 4-1 of
the Operations and Maintenance Manual.
This section provides a detailed description of the transmitter’s key modules and assemblies,
including:
Microcontroller
Microcontroller IC U41 interfaces with the transmitter via several serial buses. J17 provides an
isolated RS-232 interface with the front panel’s advanced user interface (AUI). J20 provides an
isolated RS-232 interface for debugging. There are also serial interfaces with exciter A (via J5),
exciter B (via J6), optional SC2 system controller (via J22).
U41 also acts as an internal and external serial interface for transmitter alarm and status signals.
Digital inputs
RFI filtering is provided on all digital input lines to ensure transmitter operation is not
interrupted due to RF pick up on control lines. Opto-couplers buffer/isolate the external
circuits and prevent unwanted transients from affecting transmitter operation. The digital
inputs on connector J24 are shifted in through shift register IC U42. These values are then
relayed to microcontroller U41 over the SPI bus.
Digital outputs
Shift registers U63, U64 and U83, controlled by microcontroller U41 over the SPI bus, control
the status of the digital outputs applied to connector J23. Digital output logic levels are
configured through the AUI.
Analog outputs
Digital samples of the selected (or defaulted) analog outputs are applied to DACs U61 and U62
by microcontroller U41 over the SPI bus. The analog outputs of DACs U61 and U62 are
applied to connector J24, via operational amplifiers U66:A through U66:D and U70:A through
U70:D.
• Provides an interface between the remote control/monitor facility and the transmitter.
• Provides momentary contact activation switches for each of the 24 digital inputs.
• Provides configurable status or alarm indicator LEDs for each of the 24 digital outputs.
Digital inputs
Up to 24 digital inputs can be connected to terminal blocks J7, J8, J9 and J10. You can define
these digital inputs using the advanced user interface (AUI). Each must provide a logic low
input (0 V) in its active state to the associated terminal of the remote interface PWB.
Momentary switches S1 (01) through S24 (24), which can be labelled according to their
function, provide a means to locally activate the digital inputs.
Digital outputs
Up to 24 digital outputs can be connected to terminal blocks J3, J4, J5 and J6. You can define
these digital outputs (alarm or status) using the advanced user interface (AUI). Each provides a
negative logic (current-sink-to-ground) output when a ‘true’ (alarm condition or active status)
exists. The outputs provide an open collector during logic 'false' conditions (non-alarm or non-
active status condition) and have no influence on the external monitoring circuit. Each
monitoring circuit must present impedance between the switching device and a positive dc
voltage source that results in a current flow of not more than 30 mA. Each circuit's positive
voltage source must not exceed 28 V dc. A +15 V supply is available for use by the remote
monitoring circuits on J1-34 or J1-35 (ground on J1-36 or J1-37). Bi-position shorting jumpers
E1 through E24 allow you to connect each digital output to a STATUS (green) or ALARM (red)
LED, depending on its function. The outputs can also be labelled according to their function.
Each RF power module (1 through 4) provides up to 2750 W (for NV10) or 2062.5 W (for
NV7.5) of RF output power and is comprised of an IPA PA PWB (A9), eight PA PWBs (A1
through A8), a power module interface PWB (A10), a module splitter PWB (A11) and a
combiner PWB (A12). Cooling air for the module is provided by six internal fans (B1 through
B6).
An RF Drive output from the RF drive stage is applied to each RF power module via its power
module interface PWB (A10). Within each RF power module, the RF drive signal is amplified
through an IPA PA and then split to drive the module's eight PAs. The IPA Volts input from
the associated power supply module control the RF output of the IPA PA. The PA Volts
inputs from the associated power supply modules control the RF output of the eight PAs. The
RF power module receives alarm signals (PS Temp, PS Fail and PS AC Fail) from the ac-dc
power stage, which, when active, inhibit the PAs. The RF power module also provides a Pwr
Supply Inhibit signal to the ac-dc power stage, which, when active, inhibits the associated
switching power supply. A PA V Sample and IPA V Sample from each RF power module is
applied to the control/monitor stage. The control/monitor stage supplies a PA Volts Inhibit
signal, which controls the PA outputs of the RF power module.
The RF Drive input is applied to cable T1, which is connected as a balun to provide balanced,
180° out-of-phase, RF drive signals to the individual gates of dual N-channel power MOSFET
(Q1). Cables T2:A and T2:B, as well as capacitors C2, C6, C7 and C17, inductor L2 (part of
R12/R13 leads) and resistors R5, R8 through R10, R12 and R13 provide impedance matching,
which transforms the 50 ohm input to low impedance for application to Q1. The PA voltage is
applied to the individual drains of Q1 via inductors L4 and L5, which provide proper
resonating reactance for Q1's output. Cable T3:A and T3:B transform the impedance at the RF
output, ensuring an optimum (low) impedance is presented at Q1's output. Cable T4 converts
the balanced RF signal to an unbalanced RF Output signal.
The PA V input is applied to capacitors C1, C3, C5, C8 and C11, which act as a broadband
decoupling network. Capacitor C13 and inductor L3 provide low-pass filtering of the RF signal
back to the ac-dc power stage.
The Bias input voltage is provided by the power module interface PWB to establish a dc bias
current for Q1. The bias current depends on the operating mode and whether the amplifier is
in an RF power module or an IPA module.
• Monitoring the current supplied to each PA and cause an alarm condition if a PA stops
drawing current.
• Providing a low level dc signal, proportional to the intermediate RF drive power, for
monitoring.
• Inhibiting the associated switching power supply module when the appropriate fault
occurs.
• Communicating with the control/monitor stage on module specific status and alarm
parameters.
PA fail detection
The voltages across resistors R88, R90, R93, R96, R98, R99, R101 and R103, representative of
the individual PA currents, are applied to differential amplifiers U25, U27 through U29, U31
through U33 and U35. Their output voltages are applied to input channels of multiplexer U30.
PA 1 CUR through PA 8 CUR test points are provided at the module's front panel for monitoring.
Multiplexer U30's output is fed to microcontroller U12. Microcontroller U12 outputs data to
8-bit shift registers U5 and U6.
During normal operation, when a PA is drawing current, the logic 'low' output at U5-7 causes
FET Q2 to turn off. If no current is flowing through a PA, the U5-7 output will switch to logic
'high'. This turns on FET Q2 and causes a ground potential to be applied to the Module Fault
output, which causes the FLT (fault) LED on the module splitter PWB (A11) to turn.
RF drive sample
A short section of micro-strip transmission line is in close proximity to the active exciter's RF
drive output. Due to the proximity and orientation to the micro-strip, an RF voltage
representative of the RF drive is induced in a power probe circuit. The RF drive signal is peak
detected by CR26, C131, R112 and associated components and applied to the RF Drive Sample
output (P1-18). The sample is applied to the control/monitor stage's monitoring and
protection circuits.
The RF drive signal is passed through the module splitter PWB to the IPA PA (A9). The IPA
PA output is then applied to the combiner PWB (A12), where the RF drive is split into two
equal signals. For each of the signals applied, the module splitter PWB provides four equal
amplitude PA Drive signals to drive the eight PAs. For final combining purposes, half of the
PA Drive signals are in phase quadrature (90° out of phase) with the other drive signals. The
PA outputs are applied to the combiner PWB.
Combiner PWB
See Figures SD-22 and SD-23. The combiner PWB (A12) performs the initial stage of splitting
of the RF drive signal within each RF power module. It also combines the PA outputs to
provide the final RF output for each RF power module.
The output of the IPA PA PWB (A9) is applied to hybrid splitter U1 on the combiner PWB.
U1 splits the IPA PA output into two equal amplitude, phase quadrature (90° out of phase)
drive signals for the module splitter PWB (A11). A short section of micro-strip transmission
line is in close proximity to the IPA PA output signal. Due to the proximity and orientation to
the micro-strip, an RF voltage representative of the IPA output is induced in a power probe
circuit. The IPA output signal is peak detected by CR1, C1, R13 and associated components
and applied to the IPA Pwr Sample output (terminals A/B). The sample is applied to
monitoring and protection circuits in the module interface PWB and the control/monitor
stage.
The outputs of the PA PWBs (A1 through A8) are applied to two combiner/impedance
matching networks comprised of coaxial cables and reject load resistors. These networks
provide two equal amplitude, phase quadrature (90° out of phase) amplified signals that are
applied to a hybrid combiner. The signals are combined at the hybrid combiner’s Comb RF
Out output. Any amplitude imbalances between the inputs causes a proportional signal to be
applied to the Reject Load output. Short sections of micro-strip transmission line are in close
proximity to the combined RF output and reject load output. Due to the proximity and
orientation to the micro-strips, RF voltages representative of the combined forward power,
combined reflected power, and reject power are induced in power probe circuits. The Fwd Pwr
Sample, Refld Pwr Sample and Rej Pwr Sample signals are applied to monitoring and protection
circuits in the module interface PWB.
Parts information
This section contains reference designation lists that provide descriptive and provisioning
information for all electrical and mechanical parts that have an assigned reference designation
and form a part of the subject equipment.
Family tree
Figure 3.1 depicts the family tree for the subject equipment. It is based on the descending order
of the reference designation hierarchy and identifies all assemblies that have an assigned Nautel
configuration control number.
• Follow the family tree branches to the block that represents the lowest level assembly
assigned a Nautel configuration control number. Then locate the part number index
table for that Nautel configuration control number.
• cable harnesses that are assigned a numbered Nautel part (e.g., 206-8104-02)
To obtain the full reference designation for a specific part the Nautel configuration control
number must be located in the family tree (Figure 3.1) to include the reference designation of
all higher level assemblies. The reference designation lists, which are titled and presented in
alphanumeric order, are divided into columns to aid in locating specific information.
Column content
The following paragraphs provide an explanation of the purpose and contents of each column
in the part number indexes.
Description column
This column contains the name and descriptive information for each part. The key word is
presented first, followed by the adjective identifiers. When the description is 'See Family Tree
for Assembly Nomenclature', the associated part is subject to its own part index table or is
contained in an optional kit's list. Look up the reference designation list title (nomenclature)
and the reference designation of the associated part in the family tree (Figure 3.1) to determine
where to locate its part information.
Nautel # column
This column contains the Nautel number assigned to each part. This number is Nautel's
drawing number for Nautel manufactured parts, Nautel's configuration control number for
assemblies that are under configuration control management, or Nautel's inventory
management number for purchased parts. When a Nautel configuration control number (e.g.
NAPC*) is referenced in this column, the associated ref des item is subject to its own part
index table.
Vendor # column
This column contains an original equipment manufacturer's part number for a part. A single
part number is listed for each part, even though there may be more than one known
manufacturer. The listed number is Nautel's usual or preferred choice. The use of this number
does not restrict Nautel from selecting and using commercial equivalents during manufacture,
where their use will not degrade circuit operation or reliability.
Note: OEM code 37338 is listed for parts manufactured by Nautel or to a Nautel control drawing.
United States of America customers should refer all replacement part orders to Nautel Maine
Incorporated (OEM code 57655).
https://www.bpn.gov/bincs/begin_search.asp
After entering the OEM (CAGE) code number, manufacturer pertinent information (address,
telephone number, fax number, etc.) will be displayed. Please contact Nautel if a part cannot
be obtained (see also “On-Line Part Quotes” in the Warranty section of this manual).
Manufacturer's index
For customers without web access, Table 3.1 provides a cross-reference from the original
equipment manufacturer's (OEM) codes to the manufacturer's name. The listing is sorted
alphanumerically by the OEM code.
Common abbreviations/acronyms
The following abbreviations/acronyms may appear in the Description of Part column:
• SMT
Denotes item is designed to be installed using Surface Mount Technology.
• MTA
Denotes item is a Mass Termination Assembly connector.
• SIP
Single In-line Package
• DIP
Dual In-line Package
• IDC
Denotes item is an Insulation Displacement connector for ribbon cable.
NV10 OR NV7.5
10 kW (NV10) or 7.5 kW (NV7.5) FM BROADCAST TRANSMITTER
NARF51B
A1 A2 A3 A4
CONTROL/INTERFACE PWB REMOTE INTERFACE PWB NVE50 - 50 W FM EXCITER (A) NVE50 - 50 W FM EXCITER (B)
A5 A6 A7
RF DRIVE SPLITTER/CHANGEOVER ASSY AC DISTRIBUTION ASSEMBLY POWER SUPPLY DISTRIBUTION PWB
A5A1 A5A2
SPLITTER/CHANGEOVER PWB 4-WAY RF DRIVE SPLITTER PWB
A8 - A11, A19, A20, A22
206-8160 206-8170
A23, A25, A26, A28, A29
A13A3 A13A4
RF MONITOR PROBE PWB FWD PWR/RF SAMPLE PROBE PWB
A16 A17
206-6522 206-6524 COMBINER/FILTER ASSY, 10 kW, LHS MODULE BACKPLANE PWB
NAF119/01A NAPI111
A13A5
FWD PWR/RF SAMPLE PROBE PWB
A16A1
206-6524 FILTER ASSY, 10 kW (LHS)
NAF118
F2060299 V1
NAPA20C/01 NAPI104/03
A100
UPS INTERFACE ASSEMBLY
206-5145-01
A18A11 A18A12 (OPTIONAL)
MODULE SPLITTER PWB MODULE COMBINER PWB
NAPI105/01A 206-1150
U1 U2 U3 U4
12 V POWER SUPPLY (A) 12 V POWER SUPPLY (B) LOW VOLTAGE POWER SUPPLY (A) LOW VOLTAGE POWER SUPPLY (B)
F2060300 V1
Page 1 of 84 206-1004-02
206-1150 Module Combiner PWB Assy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C02 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C03 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C04 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
CR01 Diode, Schottky, 70V, 15mA QK09 1N5711 (STATIC) 50434
CR02 Diode, Schottky, 70V, 15mA QK09 1N5711 (STATIC) 50434
CR03 Diode, Schottky, 70V, 15mA QK09 1N5711 (STATIC) 50434
CR04 Diode, Schottky, 70V, 15mA QK09 1N5711 (STATIC) 50434
R01 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R02 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R03 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R04 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R05 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R06 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R07 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R08 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R09 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R10 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R11 Resistor, MF, 221 Ohms, 1PC 1/4W RAB17 MF1/4DL2210F 59124
R12 Resistor, MF, 274 Ohms, 1PC 1/4W RAB18 MF1/4DL2740F 59124
R13 Resistor, MF, 3.32K Ohms, 1PC1/4W RAB31 MF1/4DL3321F 59124
R14 Resistor, MF, 3.32K Ohms, 1PC1/4W RAB31 MF1/4DL3321F 59124
R15 Resistor, MF, 82.5 Ohms, 1PC 1/4W RAB12 MF1/4DL82R5F 59124
R16 Resistor, MF, 82.5 Ohms, 1PC 1/4W RAB12 MF1/4DL82R5F 59124
R17 Resistor, MF, 82.5 Ohms, 1PC 1/4W RAB12 MF1/4DL82R5F 59124
R18 Resistor, MF, 82.5 Ohms, 1PC 1/4W RAB12 MF1/4DL82R5F 59124
R19 Resistor, MF, 3.32K Ohms, 1PC1/4W RAB31 MF1/4DL3321F 59124
R20 Resistor, MF, 301 Ohms, 1%1/4W RAC23 MF1/4DL3010F 59124
R21 Resistor, MF, 301 Ohms, 1%1/4W RAC23 MF1/4DL3010F 59124
R22 Resistor, MF, 3.32K Ohms, 1PC1/4W RAB31 MF1/4DL3321F 59124
RT01 Not Used - NOT USED 37338
U01 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
Page 2 of 84 206-1150
Continued from previous page
Page 3 of 84 206-4060
206-4084 Reject Load Interface PWB Assy (4-Way)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C02 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C03 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C04 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
J01 Conn, Header, Ribbon Cbl, 20Pin JQ55 103308-5 00779
J02 Conn, Header, Ribbon Cbl, 10-Pin JQ54 103308-1 00779
J03 MTA, Keyed Square Post HeaderAssy, 4 pin JU25 647123-4 00779
J04 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J05 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J06 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J07 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J08 Conn, Header, Ribbon Cbl, 10-Pin JQ54 103308-1 00779
R01 Resistor, MF, 100K Ohms, 1PC 1/4W RAC01 MF1/4DL1003F 59124
RT01 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT02 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT03 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT04 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
TP01 Terminal, Test Point, PWB,Yellow HR10 TP-106-01-04 COMP-C
Page 4 of 84 206-5145-01
206-5150-01 AC Distribution Assy (2x3way)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
J01 Conn, Socket, 3 pin, Recessed, 250Vac, 6A JT22 EAC309 82389
J02 Conn, AC Panel Outlet/Socket,250V/15A JDP45 6600-3300 61935
J03 Conn, AC Panel Outlet/Socket,250V/15A JDP45 6600-3300 61935
J04 Conn, AC Panel Outlet/Socket,250V/15A JDP45 6600-3300 61935
J05 Conn, Socket, 3 pin, Recessed, 250Vac, 6A JT22 EAC309 82389
J06 Conn, AC Panel Outlet/Socket,250V/15A JDP45 6600-3300 61935
J07 Conn, AC Panel Outlet/Socket,250V/15A JDP45 6600-3300 61935
J08 Conn, AC Panel Outlet/Socket,250V/15A JDP45 6600-3300 61935
Page 5 of 84 206-6522
206-6524 Fwd Power/RF Sample Probe PWB Assy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
J01 Conn, Receptacle, Right Angle, SMA, PWB Mount JN60 132203(RoHS) 02660
R01 Resistor,2512 SMT,100 ohms,1%,1W, RAD52 ERJ-1TYF101U PANAS
R02 Resistor, SMT, MF, 681 Ohms,1% 1/4W RAD23 MCR18EZHF6810(RO ROHM
HS)
R03 Resistor,2512 SMT,100 ohms,1%,1W, RAD52 ERJ-1TYF101U PANAS
Page 6 of 84 206-6524
206-8082 4 Input Reject PWB Assy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C02 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C03 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C04 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
CR01 Diode,SMT,Schottky,30V,0.2A,SOD-323 QDSS01 BAT54HT1(STATIC) 04713
CR02 Diode,SMT,Schottky,30V,0.2A,SOD-323 QDSS01 BAT54HT1(STATIC) 04713
CR03 Diode,SMT,Schottky,30V,0.2A,SOD-323 QDSS01 BAT54HT1(STATIC) 04713
CR04 Diode,SMT,Schottky,30V,0.2A,SOD-323 QDSS01 BAT54HT1(STATIC) 04713
J01 Conn, Header, Ribbon Cbl, 10-Pin JQ54 103308-1 00779
J02 Conn, Header, Ribbon Cbl, 10-Pin JQ54 103308-1 00779
R01 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R02 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R03 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R04 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R05 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R06 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R07 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R08 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R09 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R10 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R11 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R12 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R13 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R14 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R15 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R16 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R17 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R18 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
R19 Resistor, SMT, MF, 221 Ohms,1% 1/4W RAD17 RK73H2BL2210F 59124
R20 Resistor, SMT, MF, 221 Ohms,1% 1/4W RAD17 RK73H2BL2210F 59124
Page 7 of 84 206-8082
Continued from previous page
Page 8 of 84 206-8082
206-8101-04 Coax Cable Set Assy-NV10/NV7.5
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
W01P1 Conn, Coax, BNC, Plug, 50ohm,Crimp,RG142 JDP41 36875 02660
W01P2 Conn, Coax, BNC, Plug, 50ohm,Crimp,RG142 JDP41 36875 02660
W02P1 Conn, Coax, BNC, Plug, 50ohm,Crimp,RG142 JDP41 36875 02660
W02P2 Conn, Coax, BNC, Plug, 50ohm,Crimp,RG142 JDP41 36875 02660
W05P1 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W05P2 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W06P1 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W06P2 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W20P1 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W20P2 Conn, Coax, BNC, Plug,50ohm,Crmp,RG58/303 JF33 31-4320 02660
W21P1 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W21P2 Conn, Coax, BNC, Plug,50ohm,Crmp,RG58/303 JF33 31-4320 02660
W22J1 Conn, Coax, Jack, BNC, Crimp JT13 24-BNC-50-3-1C/133 0GZ58
NE
W22P1 Conn, Coax, SMA, Plug, Crimp, RG58 JT104 132113(RoHS) 07JE4
W30P1 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W30P2 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W33P1 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W33P2 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W34P1 Conn, Coax, N, Plug, Crimp, RG142 JT12 11-N-50-3-29/133 0GZ58
W34P2 Conn, Coax, N, Plug, Crimp, RG142 JT12 11-N-50-3-29/133 0GZ58
W37P1 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W37P2 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W40P1 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W40P2 Conn, Coax, BNC, Plug, 50ohm,Crimp JDP24 225395-7 09482
W41P1 Conn, Coax, N, Plug, Crimp, RG142 JT12 11-N-50-3-29/133 0GZ58
W41P2 Conn, Coax, N, Plug, Crimp, RG142 JT12 11-N-50-3-29/133 0GZ58
W42P1 Conn, Coax, N, Plug, Crimp, RG142 JT12 11-N-50-3-29/133 0GZ58
W42P2 Conn, Coax, N, Plug, Crimp, RG142 JT12 11-N-50-3-29/133 0GZ58
Page 9 of 84 206-8101-04
206-8103-04 Ribbon Cable Set Assy-NV10/NV7.5
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
W10P1 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W10P2 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W10P3 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W10P4 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W10P5 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W11P1 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W11P2 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W13P1 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W13P2 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W14P1 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
W14P2 Conn, Recept, Ribbon Cable, 20 pin JP45 746288-4 00779
Page 10 of 84 206-8104-04
206-8106-04 Backplane Cableform Assy-NV10/NV7.5
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
W23 Cable Cat6E, 3ft, Shld, Blue,26AWG, 75degC, noguard UA178 ZM6A-S03-06-
UA178(RoHS)
W24 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W25 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W26 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W28 Cable Cat6E, 3ft, Shld, Blue,26AWG, 75degC, noguard UA178 ZM6A-S03-06-
UA178(RoHS)
W29 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W31 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W32 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W35 Cable Cat6E, 3ft, Shld, Blue,26AWG, 75degC, noguard UA178 ZM6A-S03-06-
UA178(RoHS)
W36 Cable Cat6E, 3ft, Shld, Blue,26AWG, 75degC, noguard UA178 ZM6A-S03-06-
UA178(RoHS)
W38 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
W39 Cable Cat6E, 4ft, Shld, Blue,26AWG, 75degC, noguard UA179 ZM6A-S04-06-
UA179(RoHS)
Page 11 of 84 206-8106-04
206-8108-04 LV Cableform Assy-NV10/NV7.5
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C02 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C03 Not Used - NOT USED 37338
C04 Not Used - NOT USED 37338
C05 Not Used - NOT USED 37338
C06 Capacitor, Ceramic, 0.47uF 10% 50V CCG09 CKR06BX474KRV 56289
C07 Capacitor, Ceramic, 0.47uF 10% 50V CCG09 CKR06BX474KRV 56289
E10 Lug, Crimp, Joint, Butt,16-14 AWG, Blue HAR29 320562 09482
E11 Lug, Crimp, Joint, Butt,16-14 AWG, Blue HAR29 320562 09482
E12 Lug, Crimp, Joint, Butt,16-14 AWG, Blue HAR29 320562 09482
E13 Lug, Crimp, Joint, Butt,16-14 AWG, Blue HAR29 320562 09482
E14 Lug, Crimp, Joint, Butt,16-14 AWG, Blue HAR29 320562 09482
E15 Lug, Crimp, Joint, Butt,16-14 AWG, Blue HAR29 320562 09482
P02 Cord,AC,Jumper,3-cond,125V/250V 10A, 8ft JN55 2143H-10-C3 VOLEX PW
P03 Cord,AC,Jumper,3-cond,125V/250V 10A, 8ft JN55 2143H-10-C3 VOLEX PW
P05 Cord,AC,Jumper,3-cond,125V/250V 10A, 8ft JN55 2143H-10-C3 VOLEX PW
P06 Cord,AC,Jumper,3-cond,125V/250V 10A, 8ft JN55 2143H-10-C3 VOLEX PW
P07 MTA, Standard Dust Cover, 12 pin JU04 1-640551-2 09482
P07 MTA, Keyed Closed End Housing,12pin,22AWG JU26 1-644463-2 00779
P08 Conn, Recept, Mini-Fit dualrow, 4-pin JP59 39-01-2045 MOLEX
P08 Contact, Pin, 18-24AWG, Mini-fit (Crimp) JQ49 39-00-0039 27264
P09 Cable 6ft, 18AWG, Plug Ø 2.1mm/5.5mm UB75 310-920 L3845
P10 MTA, Closed End Housing, 2-pin, 24AWG JU30 640434-2 00779
P10 MTA,Standard Dust Cover, 2-PIN JU44 640551-2 AMP
P11 Conn, 2mm, Housing 2, PH Series, White JU63 PHR-2(RoHS)
P11 Conn, Term, PH Series, Crimp,24-30 AWG JU64 SPH-002T-
P0.5S(RoHS)
P12 MTA, Standard Dust Cover, 4 pin JU02 640551-4 09482
P12 MTA, Closed End Housing, 4 pin, 20AWG JU05 640432-4 09482
P13 MTA, Standard Dust Cover, 4 pin JU02 640551-4 09482
P13 MTA, Closed End Housing, 4 pin, 20AWG JU05 640432-4 09482
P16 MTA, Standard Dust Cover, 4 pin JU02 640551-4 09482
P16 MTA, Closed End Housing, 4 pin, 20AWG JU05 640432-4 09482
P17 MTA, Standard Dust Cover, 4 pin JU02 640551-4 09482
P17 MTA, Closed End Housing, 4 pin, 20AWG JU05 640432-4 09482
P18 Not Used - NOT USED 37338
P19 Not Used - NOT USED 37338
P20 Not Used - NOT USED 37338
P21 Not Used - NOT USED 37338
Page 12 of 84 206-8108-04
Continued from previous page
Page 13 of 84 206-8160
206-8170 4 Way RF Drive Splitter PWBAssy (NV10)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
J01 Conn, BNC, Recept, Rt Angle, PWB Mt JS21 R141665161 0GP12
J02 Conn, BNC, Recept, Rt Angle, PWB Mt JS21 R141665161 0GP12
J03 Conn, BNC, Recept, Rt Angle, PWB Mt JS21 R141665161 0GP12
J04 Conn, BNC, Recept, Rt Angle, PWB Mt JS21 R141665161 0GP12
R01 Not Used - NOT USED 37338
R02 Resistor,SMT,MF,0.005ohms,1%,1W,2512 RFCS01 ERJM1WSF5M0U 0J4G8
R03 Not Used - NOT USED 37338
R04 Not Used - NOT USED 37338
R05 Resistor,SMT,MF,0.005ohms,1%,1W,2512 RFCS01 ERJM1WSF5M0U 0J4G8
R06 Not Used - NOT USED 37338
R07 Not Used - NOT USED 37338
R08 Resistor, SMT, 3.9 Ohms, 1%, 1W, 2512 RAD58 ERJ-1TRQF3R9U
R09 Not Used - NOT USED 37338
R10 Resistor, SMT, 1820 Ohms, 1%, 1W, 2512 RAD66 ERJ-1TNF1821U
R11 Resistor,SMT,MF,10ohms,1%,2W RAD49 CR2512-2W-10R0F VENKEL
R12 Resistor, SMT, 1820 Ohms, 1%, 1W, 2512 RAD66 ERJ-1TNF1821U
R13 Not Used - NOT USED 37338
R14 Resistor,SMT,MF,10ohms,1%,2W RAD49 CR2512-2W-10R0F VENKEL
R15 Not Used - NOT USED 37338
R16 Resistor, SMT, 845 Ohms, 1%, 1W, 2512 RAD65 ERJ-1TNF8450U
R17 Resistor, SMT, 15 Ohms, 1%, 1W, 2512 RAD59 ERJ-1TNF15R0U
R18 Resistor, SMT, 845 Ohms, 1%, 1W, 2512 RAD65 ERJ-1TNF8450U
R19 Not Used - NOT USED 37338
R20 Resistor, SMT, 3.9 Ohms, 1%, 1W, 2512 RAD58 ERJ-1TRQF3R9U
R21 Not Used - NOT USED 37338
R22 Resistor, SMT, 1820 Ohms, 1%, 1W, 2512 RAD66 ERJ-1TNF1821U
R23 Resistor,SMT,MF,10ohms,1%,2W RAD49 CR2512-2W-10R0F VENKEL
R24 Resistor, SMT, 1820 Ohms, 1%, 1W, 2512 RAD66 ERJ-1TNF1821U
R25 Resistor, Chip, AIN, 50 Ohm,2%, 30W RT60 CS13725TO50GBK(Ro
HS)
R26 Resistor, Chip, AIN, 50 Ohm,2%, 30W RT60 CS13725TO50GBK(Ro
HS)
U01 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
U02 Installed at Next Higher Assy + INSTALLED AT NEXT 37338
HIGHER ASSY
Page 14 of 84 206-8170
206-8407 Fan Assy, NV Door(Dual Blower)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
L01 Ferrite, Clip-On, NiZn, 320ohms @ 100 MHz LA52 28A2025-0A2
L02 Ferrite, Clip-On, NiZn, 320ohms @ 100 MHz LA52 28A2025-0A2
P01 Conn, Plug, 3 pin, Mate-N-Lok, Mini JT39 172166-1 09482
P01 Conn, Contact, Pin, 22-18, Mate-N-Lok JT41 770987-1 09482
P02 Conn, Plug, 3 pin, Mate-N-Lok, Mini JT39 172166-1 09482
P02 Conn, Contact, Pin, 22-18, Mate-N-Lok JT41 770987-1 09482
Page 15 of 84 206-8973
NAA56/01D RF Power Module Assy, NV Series RLS 3
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
A01 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A02 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A03 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A04 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A05 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A06 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A07 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A08 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A09 PA PWB Assy, HD0.032" PA spacer plate NAPA20C/01 206-1180-05 37338
A10 Power Module Interface PWBAssy NAPI104/03 206-1170-05 37338
A11 Module Splitter PWB Assy (RLS 3) NAPI105/01A 206-1160-02 37338
A12 Module Combiner PWB Assy 206-1150 206-1150 37338
A12R1 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A12R10 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A12R2 Res, (BeO), 100 ohms, 5%, 250W Flng Mt w/stress RT70 31A20271005F
relief
A12R3 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A12R4 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A12R5 Res, (BeO), 100 ohms, 5%, 250W Flng Mt w/stress RT70 31A20271005F
relief
A12R6 Res, (BeO), 100 ohms, 5%, 250W Flng Mt w/stress RT70 31A20271005F
relief
A12R7 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A12R8 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A12R9 Res, (BeO), 100 ohms, 5%, 250W Flng Mt w/stress RT70 31A20271005F
relief
A12U1 Coupler, Hybrid, 90 degrees,3dB, Caseless UX77 10261-3 31597
B01 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
B02 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
B03 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
B04 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
B05 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
B06 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
J01 Conn, Coax, Recept, 7/16 DIN,Panel,50ohm JA44 23-716-50-0-3
HUBER & SUHNER
AG
RT01 Thermistor,-30/105ºC,10Kohms@25ºC,Neg,Bvalue RX49 EC2F103A2-07U002
3435K
Page 16 of 84 NAA56/01D
NAF118 Filter Assy, 10kW (LHS)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
L02 Inductor Assy 206-6102 206-6102 37338
Page 17 of 84 NAI21
NAL07A 4 Input Reject Load Assy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
A01 4 Input Reject PWB Assy 206-8082 206-8082 37338
A1R01 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R02 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R03 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R04 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R05 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R06 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R07 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R08 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R09 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R10 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R11 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R12 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R13 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R14 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R15 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R16 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R17 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R18 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R25 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R26 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R27 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R28 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R29 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R30 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R31 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R32 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R33 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R34 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R35 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R36 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R37 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R38 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R39 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R40 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R41 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
A1R42 Res, (BeO), 50 ohms, 5%, 250W, Flng Mt w/stress relief RT69 31A2027505F
B01 Fan, 80mm, Brushless, 48Vdc,EMI Caps, Tach w/conn ZAP50 3115RL-07W-B79-
E51(RoHS)
Page 18 of 84 NAL07A
Continued from previous page
Page 19 of 84 NAL07A
NAPA20C/01 PA PWB Assy, HD0.032" PA spacer plate
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Metal, Polyester, 10uF 100V CT38 DME1W10K 14655
C02 Capacitor,SMT,Ceramic,15pF,50V,5% CT47 C1206C150J5GAC 91929
C03 Capacitor, Metal, Polyester, 10uF 100V CT38 DME1W10K 14655
C04 Not Used - NOT USED 37338
C05 Capacitor, Ceramic, 1.0uF 100V CAP16 RPE114Z5U105M100V 91929
Page 20 of 84 NAPA20C/01
Continued from previous page
Page 21 of 84 NAPA20C/01
NAPC156A Control/Interface PWB Assy, NV Series
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
BT01 Battery, Lithium, 3V,20mm Coin Cell BBLT01 CR2032 PANAS
C001 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C002 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C003 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C004 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C005 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C006 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C007 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C008 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C009 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C010 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C011 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C012 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C013 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C014 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C015 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C016 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C017 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C018 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C019 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C020 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C021 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C022 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C023 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C024 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C025 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C026 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C027 Cap,SMT,Tantalum,10uF,10%,16V,1411 CTFS01 T494B106K016AS 31433
C028 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C029 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C030 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C031 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C032 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C033 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C034 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C035 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C036 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C037 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
C038 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
Page 22 of 84 NAPC156A
Continued from previous page
Page 23 of 84 NAPC156A
Continued from previous page
Page 24 of 84 NAPC156A
Continued from previous page
Page 25 of 84 NAPC156A
Continued from previous page
Page 26 of 84 NAPC156A
Continued from previous page
Page 27 of 84 NAPC156A
Continued from previous page
Page 28 of 84 NAPC156A
Continued from previous page
Page 29 of 84 NAPC156A
Continued from previous page
Page 30 of 84 NAPC156A
Continued from previous page
Page 31 of 84 NAPC156A
Continued from previous page
Page 32 of 84 NAPC156A
Continued from previous page
Page 33 of 84 NAPC156A
Continued from previous page
Page 34 of 84 NAPC156A
Continued from previous page
Page 35 of 84 NAPC156A
Continued from previous page
Page 36 of 84 NAPC156A
Continued from previous page
Page 37 of 84 NAPC156A
Continued from previous page
Page 38 of 84 NAPC156A
Continued from previous page
Page 39 of 84 NAPC156A
Continued from previous page
Page 40 of 84 NAPC156A
Continued from previous page
Page 41 of 84 NAPC156A
Continued from previous page
Page 42 of 84 NAPC156A
Continued from previous page
Page 43 of 84 NAPC156A
Continued from previous page
Page 44 of 84 NAPC156A
Continued from previous page
Page 45 of 84 NAPC156A
Continued from previous page
Page 46 of 84 NAPC156A
Continued from previous page
Page 47 of 84 NAPC156A
Continued from previous page
Page 48 of 84 NAPC156A
Continued from previous page
Page 49 of 84 NAPC156A
Continued from previous page
Page 50 of 84 NAPC156A
Continued from previous page
Page 51 of 84 NAPC156A
Continued from previous page
Page 53 of 84 NAPC156A
Continued from previous page
Page 54 of 84 NAPC156A
Continued from previous page
Page 55 of 84 NAPC156A
Continued from previous page
Page 56 of 84 NAPC156A
NAPI104/03 Power Module Interface PWBAssy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C001 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C002 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C003 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C004 Cap,SMT,Tantalum,10uF,10%,16V,1411 CTFS01 T494B106K016AS 31433
C005 Cap,SMT,Ceramic,10uF,20%,6.3V,X5R,0805 CCFS57 C2012X5R0J106M 54583
C006 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C007 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C008 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C009 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C010 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C011 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C012 Cap,SMT,Tantalum,10uF,10%,35V,2917 CTFS03 T494D106K035AS 31433
C013 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C014 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C015 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C016 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C017 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C018 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C019 Cap,SMT,Tantalum,10uF,10%,16V,1411 CTFS01 T494B106K016AS 31433
C020 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C021 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C022 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C023 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C024 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
C025 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C026 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C027 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C028 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C029 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C030 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C031 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C032 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C033 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C034 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C035 Cap,SMT,Tantalum,1uF,10%,35V,1411 CTFS02 T494B105K035AS 31433
C036 Cap,SMT,Ceramic,0.001uF,10%,50V,X7R,0603 CCFS01 C0603C102K5RAC 31433
C037 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C038 Cap, SMT, Ceramic, 0.1uF, 10%25V X7R, 0603 CCFS52 C0603C104K3RAC 31433
C039 Cap,SMT,Ceramic,0.01uF,10%,50V,X7R,0603 CCFS04 C0603C103K5RAC 31433
Page 57 of 84 NAPI104/03
Continued from previous page
Page 58 of 84 NAPI104/03
Continued from previous page
Page 59 of 84 NAPI104/03
Continued from previous page
Page 60 of 84 NAPI104/03
Continued from previous page
Page 61 of 84 NAPI104/03
Continued from previous page
Page 62 of 84 NAPI104/03
Continued from previous page
Page 63 of 84 NAPI104/03
Continued from previous page
Page 64 of 84 NAPI104/03
Continued from previous page
Page 65 of 84 NAPI104/03
Continued from previous page
Page 66 of 84 NAPI104/03
Continued from previous page
Page 67 of 84 NAPI104/03
Continued from previous page
Page 68 of 84 NAPI104/03
Continued from previous page
Page 69 of 84 NAPI104/03
NAPI105/01A Module Splitter PWB Assy (RLS 3)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C02 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C03 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C04 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C05 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C06 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C07 Cap,SMT,Ceramic,0.1uF,10%,50V,X7R,0805 CCFS07 C0805C104K5RAC 31433
DS01 Diode,SMT,LED,Bicolor,Red/Green,1210 QDLS04 597-7701- 83330
507(STATIC)
J01 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J02 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J03 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J04 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J05 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J06 MTA, Keyed Square Post HeaderAssy, 3 pin JU60 647123-3
J07 Conn, Jack, RJ45, PWB Mount JM44 556591-1 09482
J08 Conn, Jack, RJ45, PWB Mount JM44 556591-1 09482
J09 Conn, Coax, Recept, 20 Deg.Low Profile JT43 TMP-S01X-B1 TAIKO
L01 Inductor, SMT, Choke, 600ohms,2A, 0805 LCFS01 ILHB0805RK601V 56845
R01 Resistor, SMT, MF, 221 Ohms,1% 1/4W RAD17 RK73H2BL2210F 59124
R02 Resistor, SMT, MF, 221 Ohms,1% 1/4W RAD17 RK73H2BL2210F 59124
R03 Resistor,SMT,MF,100Kohms,1%,1/10W,0603 RFFS62 RK73H1JLTD1003F 59124
R04 Resistor, SMT, AIN, 100 ohms,2%, 30W, 3725 RT57 CS13725TO100GBK(R
oHS)
R05 Resistor, SMT, AIN, 100 ohms,2%, 30W, 3725 RT57 CS13725TO100GBK(R
oHS)
R06 Resistor, SMT, AIN, 100 ohms,2%, 40W, 1373 RT58 CS13737TO100GBK(R
oHS)
R07 Resistor, SMT, AIN, 100 ohms,2%, 30W, 3725 RT57 CS13725TO100GBK(R
oHS)
R08 Resistor, SMT, AIN, 100 ohms,2%, 30W, 3725 RT57 CS13725TO100GBK(R
oHS)
R09 Resistor, SMT, AIN, 100 ohms,2%, 40W, 1373 RT58 CS13737TO100GBK(R
oHS)
RT01 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT02 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT03 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT04 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT05 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT06 Thermistor, PTC, .15-.25 Ohms, 1.1A Hold RT17 RXE110 06090
RT07 Not Used - NOT USED 37338
S01 Switch, Rocker, Right Angle,SPDT, ON-ON SD64 M2012TXG30-DA-RO
Page 70 of 84 NAPI105/01A
Continued from previous page
Page 71 of 84 NAPI105/01A
NAPI111 Module Backplane PWB Assy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C02 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C03 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C04 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C05 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C06 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C07 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C08 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C09 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C10 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C11 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C12 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C13 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C14 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C15 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C16 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C17 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C18 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
E01 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E02 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E03 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E04 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E05 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E06 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E07 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E08 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E09 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E10 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E11 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E12 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E13 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E14 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
E15 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E16 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E17 Conn, Post Shunt, 2 Pos, .10 Centreline JQ15 390088-2 09482
Page 72 of 84 NAPI111
Continued from previous page
Page 73 of 84 NAPI111
Continued from previous page
Page 74 of 84 NAPI111
NAPI112B Power Supply Distribution PWB Assy
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C02 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C03 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C04 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C05 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C06 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C07 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C08 Capacitor, Ceramic, 0.47uF 10% 50V CCG09 CKR06BX474KRV 56289
C09 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C10 Capacitor, Ceramic, 0.47uF 10% 50V CCG09 CKR06BX474KRV 56289
C11 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C12 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C13 Capacitor, Ceramic, 0.47uF 10% 50V CCG09 CKR06BX474KRV 56289
C14 Capacitor, Ceramic, 0.001uF 10% 200V CCG01 CKR05BX102KRV 91929
SPRAGUE
C15 Capacitor, Ceramic, 0.47uF 10% 50V CCG09 CKR06BX474KRV 56289
C16 Capacitor, Ceramic, 0.1uF 10%100V CCG07 CKR06BX104KRV 56289
C17 Capacitor, Ceramic, 0.01uF 10% 100V CCG04 CKR05BX103KRV 56289
CR01 Diode, Pwr Rect, Schottky, 60VDual 2x40A UR93 STPS80L60CY(Static)(
RoHS)
STMicroelectronics
CR02 Diode, Pwr Rect, Schottky, 60VDual 2x40A UR93 STPS80L60CY(Static)(
RoHS)
STMicroelectronics
CR03 Diode, Pwr Rect, Schottky, 60VDual 2x40A UR93 STPS80L60CY(Static)(
RoHS)
STMicroelectronics
CR04 Diode, Pwr Rect, Schottky, 60VDual 2x40A UR93 STPS80L60CY(Static)(
RoHS)
STMicroelectronics
E01 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E02 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E03 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E04 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E05 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E06 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E07 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E08 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E09 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
E10 Terminal,PC Screw 10-32,30 Amp HAC55 7787 KEYSTONE
J01 MTA, Keyed Square Post HeaderAssy, 4 pin JU25 647123-4 00779
Page 75 of 84 NAPI112B
Continued from previous page
Page 76 of 84 NAPI112B
NAPI115A Remote Interface PWB Assy, NV
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
C01 Cap,SMT,Ceramic,1uF,10%,25V,,X7R,1206 CCFS10 C1206C105K3RAC 31433
CR01 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR02 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR03 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR04 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR05 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR06 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR07 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR08 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR09 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR10 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR11 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR12 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR13 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR14 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR15 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR16 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR17 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR18 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR19 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR20 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR21 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR22 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR23 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
CR24 Diode,SMT,Switching,250V,0.2A,SOD-323 QDRS01 BAS21HT1(STATIC) 04713
DS01 Diode, SMT, LED, Amber,(592nm), 0603 QDLS07 598-8040- 83330
107F(STATIC)(RoHS)
DS02 Diode, SMT, LED, Red, (660nm),0603 QDLS03 597-5112- 83330
402(STATIC)
DS03 Diode, SMT, LED, Amber,(592nm), 0603 QDLS07 598-8040- 83330
107F(STATIC)(RoHS)
DS04 Diode, SMT, LED, Red, (660nm),0603 QDLS03 597-5112- 83330
402(STATIC)
DS05 Diode, SMT, LED, Amber,(592nm), 0603 QDLS07 598-8040- 83330
107F(STATIC)(RoHS)
DS06 Diode, SMT, LED, Red, (660nm),0603 QDLS03 597-5112- 83330
402(STATIC)
DS07 Diode, SMT, LED, Amber,(592nm), 0603 QDLS07 598-8040- 83330
107F(STATIC)(RoHS)
DS08 Diode, SMT, LED, Red, (660nm),0603 QDLS03 597-5112- 83330
402(STATIC)
DS09 Diode, SMT, LED, Amber,(592nm), 0603 QDLS07 598-8040- 83330
107F(STATIC)(RoHS)
Page 77 of 84 NAPI115A
Continued from previous page
Page 78 of 84 NAPI115A
Continued from previous page
Page 79 of 84 NAPI115A
Continued from previous page
Page 80 of 84 NAPI115A
Continued from previous page
Page 81 of 84 NAPI115A
Continued from previous page
Page 82 of 84 NAPI115A
NARF51B Final Assy, NV10/NV7.5 (RLS 3)
REFDES DESCRIPTION NAUTEL # VENDOR # OEM CODE
A01 Control/Interface PWB Assy, NV Series NAPC156A 206-2010-01 37338
A02 Remote Interface PWB Assy, NV NAPI115A 206-4120-01 37338
A03 NVE Exciter A, Digital, FM NAE104A or /01 206-3400-02 37338
A04 NVE Exciter B, Digital, FM NAE104A or /01 206-3400-02 37338
A05 RF Drive Splitter/Changeover Assy, NV10 NAI21 206-8310 37338
A06 AC Distribution Assy (2x3way) 206-5150-01 206-5150-01 37338
A07 Power Supply Distribution PWB Assy NAPI112B 206-7060-02 37338
A08 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A09 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A10 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A100 UPS Interface Assembly (Optional) 206-5145-01 206-5145-01 37338
A11 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A12 Not Used - NOT USED 37338
A13 Power Probe Assy, NV NAFP109A 206-6500-01 37338
A14 4 Input Reject Load Assy NAL07A 206-6270-01 37338
A15 Reject Load Interface PWB Assy (4-Way) 206-4084 206-4084 37338
A16 Combiner/Filter Assy, 10kW (LHS) NAF119/01A 206-6000-04 37338
A17 Module Backplane PWB Assy NAPI111 206-4050 37338
A18 RF Power Module Assy, NV Series RLS 3 NAA56/01D 206-1000-05 37338
A19 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A20 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A21 RF Power Module Assy, NV Series RLS 3 NAA56/01D 206-1000-05 37338
A22 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A23 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A24 RF Power Module Assy, NV Series RLS 3 NAA56/01D 206-1000-05 37338
A25 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A26 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A27 RF Power Module Assy, NV Series RLS 3 NAA56/01D 206-1000-05 37338
A28 Power Supply Interface PWBAssy 206-4060 206-4060 37338
A29 Power Supply Interface PWBAssy 206-4060 206-4060 37338
B01 Fan Bracket Assy, NV Door 206-8406 206-8406 37338
CR01 Diode, Pwr Rect, Schottky(BeO)170V 2x100A UR94 STPS200170TV1(Stati
cs)(RoHS)
DS01 LED, Pilot Light, Amber, 230Vac BAP44 LEDTECA220AC
DS02 LED, Pilot Light, Amber, 230Vac BAP44 LEDTECA220AC
DS03 LED, Pilot Light, Amber, 230Vac BAP44 LEDTECA220AC
L01 Toroid, Ferrite, Mtl 43, 1.40"OD, 0.9" ID LP33 FT-140-43
TB01 Pwr Dist Block, 175A, 2/0-8AWG x 1, 4-14 AWG x 4 JR56 PDBFS220
Page 83 of 84 NARF51B
Continued from previous page
Page 84 of 84 NARF51B
NV10/NV7.5 Troubleshooting Manual Wiring/connector lists
• Assemblies that have a separate maintenance manual. Refer to the appropriate mainte-
nance manual for detailed wiring information for these assemblies, if provided.
• Assemblies that have their wiring information shown in tables on their assembly detail
drawing(s). Refer to the Mechanical Drawings section of this manual for detailed wiring
information for these assemblies.
Wire colours
Every effort is made to manufacture assemblies using the wire colour shown in the Colour
column of the wiring list tables. Sometimes, a white wire will be substituted for the listed
colour. In such cases, wires must be identified by their assigned numbers.
Table # Description
Table 4.5 Wiring List - NAE104A & /01 NVE50 Exciter (page 4-12)
Table 4.7 Wiring List - Ac Distribution Assembly (Nautel Part # 206-5150-01) (page 4-14)
Table # Description
Table 4.6 Connector Mating Information - NAE104A & /01 NVE50 Exciter (page 4-13)
Table 4.9 Connector Mating Information - NAA56/01D RF Power Module (page 4-16)
Table 4.6: Connector Mating Information - NAE104A & /01 NVE50 Exciter
Connector Mate Remarks
P1 U1-L
P2 U1-N
P3 A1J9
P4 A3J5
P5 A2P1
P6 A4J1
A2P1 P5
B1P1 A1J12
W1P1 A1J15
W1P2 A2J1
W2P1 A1J11 Exgine Systems Only
W2P2 A3J8 Exgine Systems Only
W3P1 A1J14 Exgine Systems Only
W3P2 A3J2 Exgine Systems Only
W4P1 A3J1 Exgine Systems Only
W4P2 U4J1 Exgine Systems Only
W5J1 EXT 10 MHz
W5P1 A1J13
W5P1 A3J3 Exgine Systems Only
W6P1 A1J13 Exgine Systems Only
W6P2 A3J4 Exgine Systems Only
Component values
Unless otherwise specified on the logic or schematic diagram, the following defaults apply:
• Resistor power ratings are not shown when less than 0.5 W
Graphic symbols
The graphic symbols used on electrical schematics are in accordance with American National
Standard ANSI Y32.2-1975 - Graphic Symbols for Electrical and Electronic Diagrams.
Logic symbols
The logic symbols used on electrical schematics and logic diagrams are in accordance with
American National Standard ANSI Y32.14-1975 - Graphic Symbols for Logic Diagrams.
Reference designations
Referenced designations were assigned in accordance with American National Standard ANSI
Y32.16-1975 - Reference Designations for Electrical and Electronic Parts and Equipment.
Each electrical symbol is identified with its basic reference designation. To obtain the full
reference designation for a specific part, prefix this basic identifier with the reference
designation assigned to all higher assemblies. For example, the complete designation for a
resistor (R1) on a printed wiring board (A1), that is part of a larger board (A2), would be A2A1R1.
Unique symbols
Nautel uses unique symbols on electrical schematics to describe logic (two-state) signals. These
signals differ from single-state signals or analog signals that may have multiple values.
The suffix on an input or output signal name identifies the active (true) state of the signal. The
high suffix (+) indicates the more positive of the two levels used to represent the logic states.
The low suffix (-) indicates the less positive of the two levels.
Two types of logic, positive and negative, may be represented on a particular schematic. In
positive logic, high represents the active (true) state, and low represents the inactive (false) state.
In negative logic, low represents the active (true) state, and high represents the inactive (false)
state.
Structure of schematics
The electrical schematics are structured in a hierarchical format that is based on function and
signal flow. Wherever practical, the signal flow is from left to right. Normally, inputs originate
on the left-hand side and outputs extend to the right-hand side. Exceptions are shown by an
arrow indicating the direction of signal flow.
Note: The physical location of a part or assembly was not necessarily a factor during
creation of the schematic. The full reference designation assigned to a part or
assembly, in conjunction with the family tree (see Section 3, “Parts Lists” on page 3-
1) and the assembly detail drawings (see Section 6, “Mechanical Drawings” on
page 6-1), will identify its location.
Figures SD-1 through SD-9 identify each major stage and its detailed interconnection. Each
stage contains cross-references that identify which blocks are the signal sources for inputs, or
the destinations for outputs.
When a sub-function is treated as a block in figures SD-1 through SD-9, its detailed circuit
information is included in its own schematic drawing(s), which is also included in this section.
1. When a functional block is assigned a reference designation (e.g., A2A1), refer to the
family trees in Section 3, “Parts Lists” on page 3-1. Follow the family tree branches to
the block that contains the desired reference designation, and associated Nautel
nomenclature (e.g., NAPI104/03 Power Module Interface PWB). Note the reference
designations and Nautel nomenclatures of all higher assemblies in the path.
Example: A18 NAA56/01D RF Power Module > A18A10 NAPI104/03 Power Module
Interface PWB.
2. Refer to Table 5.1 on page 5-5 and use the reference designation and Nautel
nomenclature to identify the appropriate schematic diagram(s).
Example: NAPI104/03 Power Module Interface PWB is shown on schematics SD-25
through SD-27.
3. If necessary, refer to the referenced figure in the schematics at the end of this section
and locate the next, lower-level assembly. Then, repeat this procedure until the desired
schematic diagram is found.
Note: Full reference designations contain the assembly hierarchical coding. When the
end item is divided into units (cabinets), the first coding is a unit number (1, 2, 3,
etc.). When the end item is divided into assemblies, the first coding is an assembly
number (A1, A2, A3, etc.). If a unit or an assembly is divided into sub-assemblies,
assembly coding that identifies assembly relationship (1A1, A2A1, A2A1A1, etc.) is
added.
2. Follow the family tree branches to the block that contains the desired reference
designation, while noting the Nautel nomenclatures and names of all higher assemblies
in the path. Example: A18 NAA56/01D RF Power Module > A18A10 NAPI104/03 Power
Module Interface PWB.
Note: The drawings in the Mechanical Drawings section depict the assembly detail
of the transmitter and its modules and assemblies.
3. Refer to Table 6.1 in Section 6, “Mechanical Drawings” on page 6-1. Use the Nautel
nomenclature and name of each family tree block in the path, starting at the highest
assembly – this is normally Figure MD-1 – to determine the figure number(s) for that
assembly.
Example: NAPI104/03 Power Module Interface PWB is shown on MD-16.
4. Refer to the referenced figure (e.g., MD-16) in Section 6.1, “List of Mechanical
Drawings” on page 6-2 to locate the desired part or assembly.
LINE 1 1 1 COM
VAC LINE 1A 1 4 VAC (2-1B4)
2 VAC LINE 1B 2B E3
3 N/C 1 VAC (2-2B1)
4 N/C J4 W7P1 VAC (3-2B4)
2 VAC (2-2B2) TO VARIOUS SHEETS
(SEE VAC REFERENCE) E4 L L
FROM EXTERNAL 2A 2B 2A 3 VAC (2-2B3) E E GND
3-PHASE AC N N
POWER SOURCE LINE 2 1 1 VAC LINE 2A 1 4 VAC (2-2B4) VAC (3-3B4) TO RF
(180-264VAC) DRIVE STAGE
208VAC NOM. 2 VAC LINE 2B 3B SHEET 1
J8 W8P1 VAC (2-1B3)
3 N/C 1 VAC (2-3B1) L L
E E GND
4 N/C N N
2 VAC (2-3B2) VAC (2-2B3)
3A 3B 3A 3 VAC (2-3B3)
LINE 3 1 1 VAC LINE 3A 1 4 VAC (2-3B4)
2 VAC LINE 3B VAC (2-1B4)
X1
3 N/C
A
4 N/C 1A TB3 1B DS1
4A 4B 1 1 VAC (3-1B1) X2
VAC (2-2B4)
1 1 2 VAC (3-1B2)
2 3 VAC (3-1B3) VAC (2-3B4)
X1
N/C
3 4 VAC (3-1B4)
A
4 DS2
2A 2B
1 1 VAC (3-2B1) X2
VAC (3-1B4)
2 VAC (3-2B2) TO VARIOUS SHEETS
(SEE VAC REFERENCE) VAC (3-2B4)
3 VAC (3-2B3) X1
4 VAC (3-2B4)
A
DS3
3A 3B
1 1 VAC (3-3B1) X2
VAC (3-3B4)
2 VAC (3-3B2)
3 VAC (3-3B3)
4 VAC (3-3B4)
S2060213 V1
Figure SD-1A: NV10/NV7.5 Transmitter - Ac-Dc Power Stage, 3-Phase, 180-264 V ac (Sheet 1A of 3)
J1 E1
5 PA VOLTS (1B) +
6
PART OF 7
A20 +VE
8
PS INTERFACE PWB 9
1B U13 10
C1
0.001
C3
0.1
POWER SUPPLY
MODULE 11
1B 12
V CTRL INH
TP1 TP2 +VE SENSE 22
E2 TO RF
W29P2 J2 J1 13
POWER STAGE
PA VOLTS CONTROL (1B) + 1 23 V_PGM 14 SHEET 1
PART OF
FROM RF PA VOLTS CONTROL (1B) - 2 15
POWER STAGE 16
A20
SHEET 1 # PS INHIBIT (1B) + 3 27 REMOTE ON/ENABLE -VE PS INTERFACE PWB
C4 C5 17 1B
GND 8 0.001 0.1 18
19 MP AC TMP FAIL
FROM AC/DC 20 TP4 TP5 TP6 TP3
VAC (2-3B1) 47 L1
POWER STAGE
SHEET 1 VAC (3-1B1) 46 L2/NEUTRAL -VE SENSE 24 J2 W29P2
45 GND/EARTH PS PRESENT 38 5 # PS MODULE PRESENT (1B) -
AC_OK_H 36 6 # PS AC FAIL (1B) -
TP15
OTP WARNING 28 7 # PS TEMP (1B) -
DC_OK_H 31 4 # PS FAIL (1B) -
C6
REMOTE ON/ENABLE RETURN 21 0.1
GND LOGIC RETURN 33
S2060112 VB
J1 J1 W14P1
FROM AC/DC E1 E1
VAC (3-2B3) 47 L1 5 FAN VOLTS (A) + 6 FAN V SAMPLE (B)
POWER STAGE TO CONTROL/
SHEET 1 VAC (3-3B3) 46 L2/NEUTRAL 6
J8 MONITOR STAGE
45 GND/EARTH 7 SHEET 1
8 5 FAN V SAMPLE (A)
PART OF +VE
9
A8 U7 10
C1
0.001
C3
0.1 PART OF
PS INTERFACE PWB POWER SUPPLY
FAN A MODULE 11 A7
FAN A 12 POWER SUPPLY
DISTRIBUTION
PART OF +VE SENSE 22 PWB
A7 V CTRL INH 13
E2
POWER SUPPLY P16
DISTRIBUTION TP1 TP2 14 PART OF 1 FAN VOLTS (MODULES 1 TO 4) +
PWB 15 2 FAN VOLTS (MODULES 1 TO 4) + TO RF
W14P1 J8 J12 W23P1 W23P2 J2 A8 J1 POWER STAGE
FAN VOLTS CONTROL + 13 1 FAN VOLTS CONTROL (A) + 1 23 V_PGM 16 PS INTERFACE PWB 3 GND SHEET 1
-VE
FAN VOLTS CONTROL - 14 2 FAN VOLTS CONTROL (A) - 2 17 FAN A 4 GND
18
# FAN PS INHIBIT (A) + 11 3 # FAN PS INHIBIT (A) + 3 27 REMOTE ON/ENABLE 19
C4 C5 MP AC TMP FAIL 1
GND 12 8 GND 8 0.001 0.1 20 TP4 TP5 TP6 TP3 2
J2
-VE SENSE 24 3
J2 W23P2 W23P1
PS PRESENT 38 5 # FAN PS MODULE PRESENT (A) - 5 4
AC_OK_H 36 6 # FAN PS AC FAIL (A) - 6
W13P1 J7 J9 W25P1 TP7 J12
OTP WARNING 28 7 # FAN PS TEMP (A) - 7 1
IPA VOLTS CONTROL + 7 1 IPA VOLTS CONTROL (A) +
DC_OK_H 31 4 # FAN PS FAIL (A) - 4 2
IPA VOLTS CONTROL - 8 2 IPA VOLTS CONTROL (A) - C6 J3
REMOTE ON/ENABLE RETURN 21 0.1 3
# IPA PS INHIBIT (A) + 5 3 # IPA PS INHIBIT (A) + GND LOGIC RETURN 33 4
GND 6 8 GND TO AC/DC
J10 W26P1 POWER STAGE
1 IPA VOLTS CONTROL (B) + SHEET 2 1
FROM
CONTROL/ 2 IPA VOLTS CONTROL (B) - 2
J4
MONITOR # IPA PS INHIBIT (B) + 13 3 # IPA PS INHIBIT (B) + 3
STAGE GND 14 8 GND J1 E1 E2 4
SHEET 1 5 FAN VOLTS (B) +
J11
1 6 P12
PART OF 7 1 FAN VOLTS (REJECT LOAD A) +
2 E3 TO RF
GND 2 FAN VOLTS (REJECT LOAD A) +
# IPA PS INHIBIT (C) + 19 3 A9 +VE
8 J5 POWER STAGE
PS INTERFACE PWB 9 3 GND SHEET 3
GND 20 8
FAN B U8 10
C1
0.001
C3
0.1 4 GND
POWER SUPPLY
MODULE 11
FAN B 12 1
V CTRL INH 2
TP1 TP2 +VE SENSE 22 J6
3
E2
J13 W24P1 W24P2 J2 J1 13 4
1 FAN VOLTS CONTROL (B) + 1 23 V_PGM 14
PART OF
2 FAN VOLTS CONTROL (B) - 2 15
W14P1 J8 16
A9
N/A 19 3 # FAN PS INHIBIT (B) + 3 27 REMOTE ON/ENABLE -VE PS INTERFACE PWB
C4 C5 17 FAN B
GND 20 8 GND 8 0.001 0.1 J8 W14P1
18
7 # FAN PS MODULE PRESENT (A) -
19 MP AC TMP FAIL 8 # FAN PS AC FAIL (A) -
FROM AC/DC 20 TP4 TP5 TP6 TP3
VAC (2-3B4) 47 L1 9 # FAN PS TEMP (A) -
POWER STAGE
SHEET 1 VAC (3-1B4) 46 L2/NEUTRAL -VE SENSE 24 J2 W24P2 W24P1 10 # FAN PS FAIL (A) -
45 GND/EARTH PS PRESENT 38 5 # FAN PS MODULE PRESENT (B) - 5 15 # FAN PS MODULE PRESENT (B) -
AC_OK_H 36 6 # FAN PS AC FAIL (B) - 6 16 # FAN PS AC FAIL (B) -
TP7 J13
OTP WARNING 28 7 # FAN PS TEMP (B) - 7 17 # FAN PS TEMP (B) -
DC_OK_H 31 4 # FAN PS FAIL (B) - 4 18 # FAN PS FAIL (B) -
C6
REMOTE ON/ENABLE RETURN 21 0.1
GND LOGIC RETURN 33
5 15 N/A
6 16 N/A
J11
7 17 N/A
S2060216 V1 4 18 N/A
4 N/C
5 N/C
J8 6 N/C
7 N/C
8 N/C
S2060217 V1
A4
NVE EXCITER B
(OPTIONAL) W4P2
W8P2 U1
FROM AC/DC VAC (2-1B3) A3 TRANSMITTER LINK RX (EXCTR B) +
L AC
POWER STAGE GND E A6 TRANSMITTER LINK RX (EXCTR B) -
SHEET 1 N MAINS
VAC (2-2B3) A1J4 A4 STREAMING BUS TX (EXCTR B) +
W4P2 A5 STREAMING BUS TX (EXCTR B) -
FROM CONTROL/ TRANSMITTER LINK TX (EXCTR B) + A1 A8 GND
MONITOR STAGE TRANSMITTER LINK TX (EXCTR B) - A2 A1J4
SHEET 2 # EXCITER RF MUTE (B) - A7
FROM RF
POWER STAGE EXCITER RF SAMPLE (B)
SHEET 2 W6P2 A1J1 A2J2 W2P1
A5
RF DRIVE SPLITTER/
CHANGEOVER ASSY
2 NC K1:A
RF DRIVE (A)
W1P2 J1 COM 1 A2
3 NO
A1 4-WAY RF DRIVE
4 SPLITTER/ATTEN PWB
RF DRIVE (B) SPLITTER/ R2
W2P2 J2 CHANGEOVER PWB 0.005
1W
W9P2 J3 A 0 C -180 RF DRIVE (1)
5 1 3 R5 J1 W30P1
+15V RELAY CONTROL 5 IN 0
R25 U1 0.005
B D 10261-3 1W R8
CR2 K1:B * 0 REF 50 3.9
1 3 2 4
# EXCITER RELAY CONTROL - 4 IN 0 30W ISO -90 1W
FROM CONTROL/ 6 U1 -90 RF DRIVE (2)
MONITOR STAGE N/A 3 10261-3 C -90 A R12 R11 R10 J2 W33P1 TO RF
2 4
SHEET 1 N/A 6 ISO -90 1820 10 1820 POWER
C1 R14
R3 CR1 * R1 R2 R4 D B 10 1W 1W 1W STAGE
N/A 7 3320 0.001 1N5711 332 121 50 1W SHEET 1
N/A 8 250W RF DRIVE (3)
1 3 0 J3 W37P1
2 IN 0 R18 R17 R16
U2 845 15 845
10261-3 R20
1 * DENOTES A MICRO-STRIP TRANSMISSION LINE OF SPECIFIC 1W 1W 1W 3.9
2 4
LENGTH AND CHARACTERISTIC INPEDANCE. ISO -90 1W
R26 -90 RF DRIVE (4)
50 R24 R23 R22 J4 W40P1
30W 1820 10 1820
1W 1W 1W
TO CONTROL/
S2060115 VC GND MONITOR
RF DRIVE PWR SAMPLE STAGE
SHEET 1
FROM RF 88 RF DRIVE
DRIVE STAGE RF DRIVE (1) 86 RF DRIVE
SHEET 1 W30P2 J15 PART OF *
85 GND RF POWER MODULE
87 GND A18 1 2 3 4
RF POWER FUNCTION A18 A21 A24 A27
S4
MODULE 1
1 MODULE BACKPLANE PWB
1 A0
1 A17
4
3 A1 BUS A17J14 A17J10 A17J5 A17J1
2 2 (RIBBON CABLE) W10P2 W10P3 W10P4 W10P5
5 3
5 A2 ADDRESS RF DRIVE A17J15 A17J11 A17J6 A17J2
4
6 (COAX) W30P2 W33P2 W37P2 W40P2
7 A3
8 PROGRAMMING
A17J16 A17J12 A17J7 A17J3
E17:1 E17:2 E17:3 HEADER
9 A4 PS CTRL A A17J17B A17J13B A17J8B A17J4B
OPEN CLSD (CAT5E) W28P1 W31P1 W35P1 W38P1
J16 PS CTRL B A17J17A A17J13A A17J8A A17J4A
MISO 1 6 MISO (CAT5E) W29P1 W32P1 W36P1 W39P1
SCK 3 10 SCK RF MODULE
MODULE (1) A17J21 A17J20 A17J19 A17J18
MOSI 4 12 MOSI INTERCONNECT
PROGRAMMING A18A10P1 A21A10P1 A24A10P1 A27A10P1
# RESET - 5 14 # RESET - (EDGE CARD)
HEADER
+5V 2 PA VOLTS #A+ A17E15 A17E11 A17E6 A17E2
TP12 PA VOLTS #B+ A17E16 A17E12 A17E7 A17E3
GND 6
35 GND IPA VOLTS + A17E10 (COM 1) +
W10P2 J14 36 GND FAN VOLTS A17J9
+5V 1 GND (4-PIN MTA) P17
+5V 2
+5V 3 20 +5V
-15V 5 22 -15V NOTES:
GND 4 TERM N/C RF POWER MODULE INTERFACE PWB (A10) EDGE CARD CONNECTOR P1 AND MODULE BACKPLANE
R15 PWB CONNECTOR ARE BLIND-MATE CONNECTIONS. SEE TABLE ABOVE FOR SPECIFIC RF POWER
GND 6 221 E14:3 E14:2 E14:1 MODULE AND MODULE BACKPLANE PWB CONNECTIONS.
GND 11
R16
FROM CONTROL/ GND 13 221 RF POWER MODULE 2 THROUGH 4 ARE IDENTICAL TO RF POWER MODULE 1 EXCEPT FOR DIFFERENCES
MONITOR STAGE SHOWN IN THE TABLE ABOVE. CHANGE SIGNAL NAME REFERENCES OF (1), (1A) OR (1B) TO (2) THROUGH
SHEET 1 (4) AS APPLICABLE.
INT TX/RX 7 24 TX/RX
INT TX/RX 8 26 TX/RX * DENOTES GROUND CONNECTION BETWEEN RF POWER MODULE AND TRANSMITTER CHASSIS IS BLIND-MATE.
# PA VOLTS INHIBIT - 9 30 # PA VOLTS INHIBIT -
FOR PA VOLTS #A+ OR #B+, # REPRESENTS THE RF POWER MODULE NUMBER (1-4).
N/A 15
N/A 18
N/A 19
N/A 20 J17 W29P1
PA VOLTS CONTROL + 17 A1 PA VOLTS CONTROL (1B) +
PA VOLTS CONTROL - 16 A2 PA VOLTS CONTROL (1B) - TO AC/DC
W28P1 POWER STAGE
B1 PA VOLTS CONTROL (1A) + SHEET 2
B2 PA VOLTS CONTROL (1A) -
S2060116 VB
* * * * *
R3 R1 R2 R1 R3 R3 R1 R2 R3 R1 R2 R3 R1 R2
100 100 681 100 100 100 100 681 100 100 681 100 100 681
NOTES: 1W 1W 1W 1W 1W 1W 1W 1W 1W 1W E1
RF POWER MODULE OUTPUT CONNECTOR J1 AND SPECIFIC 5kW COMBINER/FILTER ASSEMBLY
CONNECTOR ARE BLIND-MATE CONNECTIONS. A1 A2 A3 A4 A5
* DENOTES A MICRO-STRIP TRANSMISSION LINE OF SPECIFIC LENGTH AND CHARACTERISTIC IMPEDANCE. FWD PWR REFLD PWR RF MONITOR PWB RF SAMPLE PWB A RF SAMPLE PWB B
PROBE PWB PROBE PWB
** DENOTES INDUCTORS AND CAPACITORS IN LOW PASS FILTER ARE SHOWN FOR REFERENCE ONLY.
EXCITER RF SAMPLE (B)
A5J1 W6P1 TO RF
DRIVE STAGE
SHEET 1
EXCITER RF SAMPLE (A)
A4J1 W5P1
A13
OUTPUT POWER
PROBE ASSY RF MONITOR CUSTOMER
A3J1 W22P1 W22J1 RF MONITOR
PART OF
RF
A18 OUT J1 J1 RF IN 1 5kW 10kW ** ** ** ** REFLD PWR SAMPLE
RF POWER -180° ** ** ** ** ** A2J1 W21P1 TO CONTROL/
MODULE 1 ** MONITOR STAGE
SHEET 1
** A1 FWD PWR SAMPLE
PART OF 10kW LOW PASS A1J1 W20P1
RF FILTER ASSY
A21 OUT J1 J2 RF IN 2
RF POWER -90°
MODULE 2
S2060117 V2
FAN V
A14B1L1 A14B1P1 J4 R1
REJ A FAN VOLTS 1 + 3 100K
C1
A14B1 REJ A FAN VOLTS 1 - 2 0.1 RT1
RXE110
A14 TO
4-INPUT REJ A FAN TACH 1 1 11 REJ FAN TACH 1 CONTROL/
REJECT MONITOR
LOAD A14B2L1 STAGE
A14B2P1 J5 SHEET 1
ASSY REJ A FAN VOLTS 2 + 3
C2
A14B2 REJ A FAN VOLTS 2 - 2 0.1 RT2
RXE110
REJ A FAN TACH 2 1 12 REJ FAN TACH 2
A14B3P1 J6
REJ A FAN VOLTS 3 + 3
C3
A14B3 REJ A FAN VOLTS 3 - 2 0.1 RT3
RXE110
REJ A FAN TACH 3 1 13 REJ FAN TACH 3
A14B3L1 J7
3
C4
NOTE: 2 0.1 RT4
UNUSED CONNECTOR PINS ARE NOT SHOWN FOR SIMPLICITY. RXE110
1 14 N/A
15 N/C
16 N/C
P13 J3 17 N/C
FROM FAN VOLTS (REJECT LOAD A) + 1
AC/DC 18 GND
FAN VOLTS (REJECT LOAD A) + 2
POWER 19 GND
STAGE GND 3
20 GND
SHEET 3 GND 4
S2060294 V1
+15V_SAMPLE(B)
TP7
R186 R187 C92 R188 C93
8250 1210 0.1 475K 0.1
14 11 3 R137
+5V VDD DACB 10.0K
C152 C151 R234 C117 J3
0.1 0.01 R203 U15:A 1
7 IPA VOLTS R130
0.0 1.00M 0.01 R115 C43 CONTROL 10.0K
2 J3 9
10 0.01 8
8 -15V_SAMPLE(B)
2 R150 R227 R233 C143 R239 U5:C
+2.5V REFA R166 8250 0.1 10.0K
L24 C165 3 12.1K 1210 R129 C48
REFB 10.0K 10 475K 0.1
0.01 TO SHEET 1
4 TP26
REFC +5V_SAMPLE(A)
5
REFD
R74 R353 C208 R340 C205
R146 15.0K 10.0K 0.1 475K 0.1
10 10
MOSI DACC 10.0K
6 R248 C114 J10
DATA R176 U15:C 8
13 FAN VOLTS +15V_SAMPLE(A)
SCK 0.0 1.00M 0.01 R116 C60 CONTROL
7 9 J10 R144 C220 R371 C217
FROM SHEET 1 CLK 10 0.01 14 R372
#SS_3(DAC_2)- 8250 1210 0.1 475K 0.1
8 R181
LOAD U35 R180
10.0K 12.1K
TLV5620ID TP4
R380
10.0K
13
R106 14 -15V_SAMPLE(A)
3 R345 R350 C203 R349 U55:D
10.0K 8250 0.1 10.0K
J1 1210 R381 C239
U5:A 1
17 PA VOLTS CONTROL (A) + 12 475K 0.1
1 R40 C2
4 12 GND 2 10 0.01
+3.3V ENABLE ENABLE
TP8
C46 C37 U13:E 13
LDAC R64
1.0 0.1 DS26C32ATM R63 +5V
16
VCC GND
8 10.0K 12.1K TP5 J1
U1 1 +5V
STPS15L30CB R145 J1
J11 A1 10.0K +5V 2 +5V
+5V (B) 2
4 12 12 5 R132 K J1
+3.3V ENABLE ENABLE DACA 10.0K 3 +5V
J1 J11 A2 L2 C27 L10
C120 C112 U28:E R131 C28 U5:B 18 PA VOLTS CONTROL (B) + +5V (A) 1 C38 C47
DS26C31TM R105 7 10 +15V
1.0 0.1 0.0 1.00M 0.01 R51 C3 J11 0.1 0.01 TP25
16 8 6 GND 3 16V J22
VCC GND 10 0.01 5 +15V
+15V (SYS CTRL A)
R65 R66 U14 RT1
10.0K 12.1K TP24 J11 A1
STPS15L30CB R215 RXE090
4 U7:E 11 +15V (B) 5 10.0K
+5V VDD GND K J4 +15V RELAY
TLV2374ID 5
C69 J11 A2 L19 C89 L11 R57 R56 SUPPLY
0.1 R138 +15V (A) 4 C113 C121
5 J11 10 RT2 10 20
10.0K 0.1 0.01
U15:B
J1
19 PA VOLTS CONTROL (C) + GND 6 35V RXE017 2W 2W
7 TP27
4 U15:E 11 R140 C68
+15V VCC VEE -15V 6 10 0.01 -15V
C116 MC33074AD C115 J11
-15V (B) 8
0.1 0.1
R177 R182 CR20 R242
10.0K 12.1K TP28 -15V (A) STPS140A 10.0K
J11 J1
4 U5:E 11 7 5 -15V
+15V VCC VEE -15V GND J11 CR14 L20 C131 L1
C42 MC33074AD C39 9 C132 C133 R136 R194 R241 J1
R147 STPS140A 10 0.1 0.01 -15V 4
0.1 0.1 12 35V 0.0 562 562
10.0K J1
J1 6
U15:D 20 PA VOLTS CONTROL (D) + R142 R193 R244
14
R139 C71 J22 J1
13 J1 INTLK (SYS CTRL A) + 7 274 562 562 11
10 0.01 16 +5V J1
J22 G G
13
GND (SYS CTRL A) 6 DS1 DS2 DS3
R148 R149 G
10.0K 12.1K R598 +5V +15V -15V
182K Q2
TP6 2N7002LT1
9 SWR_SHUTBACK_REF 1 #INTERLOCK_OPEN-
+3.3V DACD TO SHEET 7 R597 C367 TO SHEET 3
TRANSMITTER E19:1 18.2K 0.1
R173 INTERLOCK LCL GND
U23 10.0K
1 3 2 E19:2
+5V IN LM3940IT-3.3 OUT +3.3V +2.5V TO SHEET 6 J25
C94 GND C90 R190 R189 R178
RMT GND +15V 3 +15V-A (SYS CTRL B)
0.01 47 J25
2 100 100 100 TP36 3 E19:3 7 +15V-B (SYS CTRL B)
16V R599 RT4 J25
C369 RXE090 6
+2.5V REF 0.0 0.001 J25
U18 4 8
10 TP31
R270 1 74LVC257APW
10.0K
9
5 IPA V
4 U33 6 11
+5V VIN LT1790BIS6-2.5 VOUT +2.5V 0 8 2
GND R8 IPA_V_SAMPLE
L21 C148 C137 C154 6
GND1 GND2 R269 15 100K U7:A TO SHEET 4
0.1 1.0 1000 0.001 OE 1
1 2
35V 6 3
1 R42 C31
7 R68
J25 1.21M 0.1
5 INTLK (SYS CTRL B) + 4 TP30 100K
0
J25 PA V
GND (SYS CTRL B) 5
13 6
1 R7 PA_V_SAMPLE
12
J5 2 100K U7:B TO SHEETS 3 & 4
STREAMING BUS TX (EXCTR A) + 4 U13:A 14 7
0
J5 3 J13 R41 C30 5
STREAMING BUS TX (EXCTR A) - 5 6 STREAMING BUS TX (AUI) +
1
3 121K R67 0.01
1 U28:A 2 R214 10.0K
4 TP1
J6 6 49.9
STREAMING BUS TX (EXCTR B) + 4 U13:B 2 1 J13 FAN V(A)
0 R207 1 STREAMING BUS TX (AUI) -
J6 5 3
R213 9
STREAMING BUS TX (EXCTR B) - 5 0.0
7 49.9 J13 R54 FAN_V_SAMPLE_A
3 GND 100K U7:C 8
#SELECT_STREAMING_B- 1 SELECT 16 J13
FROM SHEET 1 VCC +3.3V 8
C91 R70 C13 10
0.1 J1 1.21M R69 0.1
IPA V SAMPLE 14 TP2 100K
J1 TO SHEET 4
PA V SAMPLE 12 FAN V(B)
13
J12 FS (+) J21 J10 R55 FAN_V_SAMPLE_B
1 1 FAN V SAMPLE (A) 5 100K U7:D
J12 FS (-) J21 J10 14
2 2 FAN V SAMPLE (B) 6
J12 TX DATA (+) J21 R71 C33 12
3 3 1.21M R76 0.1
J12 CLK (+) J21 100K
4 4
SBC IN (LAN) J12 CLK (-) J21 SBC OUT (LAN)
5 5
J12 TX DATA (-) J21
6 6
J12 RX DATA (+) J21
7 7
J12 RX DATA (-) J21
8 8
S2060192 SHEET 2 OF 8 V5
LATCH_OE
FROM SHEET 1
S2060192 SHEET 3 OF 8 V5
6 1
TP17 A0
7 REJ_2 2
U26:B A1
J2 R199 3
REJ PWR SAMPLE 2 2 5 A2
R10 C82 R159 C104 100
R44 4
6810 10.0K 0.1 47.5K 0.1 A3
5
A4
6 20
A5 VCC +5V
9 7 C146 C144
TP18 A6 0.01 0.1
8 REJ_3
U26:C 8
J2 A7 U32
REJ PWR SAMPLE 3 3 R200 9
R11 C83 R160 C105 10 100 A8 TLC1543IDW
R45 11
6810 10.0K 0.1 47.5K 0.1 A9
12
A10
#SS_0(ADC_1)- 15
13 CS +5V
TP19
14 REJ_4 14
U26:D REF+
J2 R221 L23 C150
REJ PWR SAMPLE 4 4 12 R264
R12 C84 R161 C106 100 0.01 10.0K
R46 13
6810 10.0K 0.1 47.5K 0.1 REF- 19 #EOC-
10 EOC
GND
CR50
BAT54HT1 TO
17
ADDRESS SHEET 1
FROM SHEET 1 18 16 MISO
I/O_CLK DATA_OUT
VREF
SCK 18
I/O_CLK
TP20 2 MOSI 17 16
1 REJ_5 ADDRESS DATA_OUT
U27:A #SS_1(ADC_2)- 15
J2 R222 CS
REJ PWR SAMPLE 5 5 3
R13 C85 R162 C107 100 19
R47 EOC
6810 10.0K 0.1 47.5K 0.1 IPA_V_SAMPLE CR49
11
A9 BAT54HT1
PA_V_SAMPLE 9 U31
A8
FROM SHEET 2 FAN_V_SAMPLE_A 8 TLC1543IDW
TP21 6 A7 20
REJ_6 FAN_V_SAMPLE_B VCC +5V
7 7 C145 C153
U27:B A6
J2 R201 0.01 0.1
REJ PWR SAMPLE 6 6 5
R14 C86 R163 C108 100 1
R48 A0
6810 10.0K 0.1 47.5K 0.1
14
TP39 REF+
L22 C149
+12V FAN V 0.01
TP22 9 2
8 REJ_7 R273 1 6
U27:C 10.0K U38:A A5
J2 R202 J10 R293
REJ PWR SAMPLE 7 7 10
+12V FAN V SAMPLE 3 3
R15 C87 R164 C109 100 R272 L25 R274 C155 R276 C158 100
R49 R275
6810 10.0K 0.1 47.5K 0.1 0.0 6810 1210 0.1 475K 0.1
J14 13
ALTERNATE ADC 1 1 TP44 REF-
J14 10
2 GND
TP23 13 6
14 REJ_8 R313 7 5
U27:D 10.0K U38:B A4
J2 R223 J14 R292
REJ PWR SAMPLE 8 8 12
SPARE ADC 1 3 5
R16 C88 R165 C110 100 L27 R289 C170 R291 C171 100
J2 R50 J14 R290
9 6810 10.0K 0.1 47.5K 0.1 4 1000 10.0K 0.1 475K 0.1
J2
10
TP13 2
1 REJ_13 2
U25:A A1
J9 R218
REJ PWR SAMPLE 13 5 3
R92 C78 R155 C100 100
R121
6810 10.0K 0.1 47.5K 0.1
TP9 2 TP14 6
1 REJ_9 7 REJ_14 3
U24:A U25:B A2
J9 R216 J9 R197
REJ PWR SAMPLE 9 1 3
REJ PWR SAMPLE 14 6 5
R88 C74 R151 C96 100 R93 C79 R156 C101 100
R117 R122
6810 10.0K 0.1 47.5K 0.1 6810 10.0K 0.1 47.5K 0.1
TP15 9
8 REJ_15 4
TP10 6 U25:C A3
J9 R198
7 REJ_10 REJ PWR SAMPLE 15 7
U24:B 10 100
J9 R94 R123 C80 R157 C102
REJ PWR SAMPLE 10 2 R195 6810 0.1 47.5K 0.1
5 100 10.0K
R89 R118 C75 R152 C97
6810 10.0K 0.1 47.5K 0.1 TP38 13
14 REJ_16 12
U5:D A10
J9 R263
REJ PWR SAMPLE 16 8 12
TP11 9 R53 R226 C142 R237 C141 100
R238
8 REJ_11 0.0 6810 10.0K 0.1 47.5K 0.1
U24:C J11
J9 R196 ALTERNATE ADC 2 10
REJ PWR SAMPLE 11 3 10
R90 C76 R153 C98 100
R119
6810 10.0K 0.1 47.5K 0.1 TP3 13
RF DR 14 RF_DRIVE_PWR_SAMPLE
U25:D TO SHEET 1
J4 R219
RF DRIVE PWR SAMPLE 2 12
TP12 13 R78 C34 R128 C67 100
J4 R77
14 REJ_12 1 8250 10.0K 0.1 475K 0.1
U24:D
J9 R217
REJ PWR SAMPLE 12 4 12
R91 C77 R154 C99 100
R120
6810 10.0K 0.1 47.5K 0.1
J9
9
J9
10
S2060192 SHEET 4 OF 8 V5
J24
6
EXT J24
J23 E9:2 12
EXTERNAL +15V SUPPLY 34 +15V-A
J23 E9:1 J24
35 18
+15V INT J24
J23 E9:3 24
36 8
+5V VCC J24
J23 C261 3 29
37 WP
0.1
7
HOLD J23
U66 J23 +15V 32 +15V (REMOTE)
30
AT25256B-SSHL-B C287 L35 J23
SCK 6 J23 RT3 1.0 33
SCK 31
4 RXE110
MOSI GND
5
FROM SHEET 1 SI
#SS_4(SERIAL_EEPROM)- 1 2 MISO
CS SO TO SHEET 1
S2060192 SHEET 5 OF 8 V5
+15V
4 6 J6 A A A
DI DO/RI 1 TX+ DS23 DS24 DS25 R DS7 R DS8 R DS9 R DS10 R DS11
1 R82 U63:C R430 30% 20% 10% OUTPUT IPA/PA EXCITER POWER EXTERNAL
RO 100 EXCITER B 14 15
7 J6 A QA
3 14 R431 NETWORK SUPPLY
U11 DO/RI 2 TX- 16 U63:D 1500 1500
R60 +5V VCC 1 R432 R258 R259 R260 R261 R262
EXB_TXD_SELECT DS36C278TM QB
3
DE 100 C168 C169 10
RESET
4 13
U63:E 1500 1500 1500 1500 1500 1500
8 0.01 0.1 2
VCC +5V QC
5 12
C36 8 3 U34:E
2 5 GND U37 QD
FROM SHEET 1 RE GND 0.1 5 12
MC74HC595AD 4 U34:A
13 QE
OE
5 U34:B 1 16
EXCITER_SELECT 1 QF
3 2 8 2 15
U17:A RE VCC +5V 6 U34:C
C45 QG
+5V 2
11 U34:D 3 14
1 0.1 SHIFT_CLK 7
RO U12 QH
4 13
R83 DS36C278TM 12
681 LATCH_CLK 9
J6 6 SQH
RX+ 3 DO/RI 3
DE
R61 R87 4
221 221 DI
J6 7 5
RX- 6 DO/RI GND
REMOTE OUTPUTS
J6 R84
GND 8 681 14 15 U74:C R538 J23
A QA 1 # DIGITAL OUT 01 -
16 1 U74:D 3 14
12.1 R540 J23
+5V VCC QB 2 # DIGITAL OUT 02 -
EXCITER_RX_DATA C265 C266 10 4 13
RESET 2 U74:E R541 12.1 J23
0.01 0.1 QC 3 # DIGITAL OUT 03 -
8 3 U74:F 5 12
12.1 R543 J23
GND U69 QD 4 # DIGITAL OUT 04 -
SELECT_A 11 3 FAN_MUX_A 6 11
A X MC74HC595AD 4 U74:G R546 12.1 J23
SELECT_B 13 QE 5 # DIGITAL OUT 05 -
FROM SHEET 1
10
B OE
5 U76:A 7 10
12.1 R548 J23
SELECT_C QF
1 16
7 # DIGITAL OUT 06 -
9 U76:C R549 12.1 J23
C 11 6
U2 SHIFT_CLK QG 8 # DIGITAL OUT 07 -
+5V +5V +5V +5V +5V +5V +5V MC74HC4051AD 7 U76:D 3 14
12.1 R550 J23
12 QH
4 13
9 # DIGITAL OUT 08 -
LATCH_CLK C322 C321 C320 C318 C315 C313 C312 C310 12.1
R17 R18 R19 R20 R21 R22 R23 9 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 J23
4750 4750 4750 4750 4750 4750 4750 SQH 6
J2 13 16 J23
REJ FAN TACH 1 11 X0 VCC +5V 12
L3 C70
J2 14
REJ FAN TACH 2 12 X1 0.1
L4 TO SHEET 1
J2 15
REJ FAN TACH 3 13 X2
L5
J2 12 14 15 U76:E R551 J23
REJ FAN TACH 4 14 X3 A QA 10 # DIGITAL OUT 09 -
L6
J2 1 11 1 U76:F 5 12
12.1 R552 J23
REJ FAN TACH 5 15 X4 SHIFT_CLK QB 11 # DIGITAL OUT 10 -
L7 6 11
J2 5 12 2 U76:G R553 12.1 J23
REJ FAN TACH 6 16 X5 LATCH_CLK QC 13 # DIGITAL OUT 11 -
L8
J2 2 16 3 U75:A 7 10
12.1 R539 J23
REJ FAN TACH 7 17 X6 6 +5V VCC QD 14 # DIGITAL OUT 12 -
L9 C6 C7 C8 C9 C10 C11 C12 ENABLE 1 16
J2 7 C267 C268 10 4 U75:B R542 12.1 J23
18 0.001 0.001 0.001 0.001 0.001 0.001 0.001 VEE 0.01 0.1 RESET U70 QE 15 # DIGITAL OUT 13 -
J2 4 8 MC74HC595AD U75:C 2 15
12.1 R544 J23
19 +5V X7 GND 5
J2 QF 16 # DIGITAL OUT 14 -
20 R38 C4 3 14
U75:D R545 12.1 J23
4750 0.001 6
QG
4 13
17 # DIGITAL OUT 15 -
8 7 U75:E 12.1 R547 J23
GND QH
5 12
19 # DIGITAL OUT 16 -
SELECT_A2 11 3 FAN_MUX_B C319 C317 C316 C314 C311 C325 C324 C323 12.1
A X 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
13 9 J23
SELECT_B2 10 OE SQH 18
FROM SHEET 1 B
J23
SELECT_C2 9 24
C
U8 J23
9 U92:H 8 29
+5V +5V +5V +5V +5V +5V +5V MC74HC4051AD COM GND
CR93 MC1413BD
1SMB5939B U92:A R589
39V 14 15 J23
R95 R96 R97 R98 R99 R100 R101 A QA 20 # DIGITAL OUT 17 -
4750 4750 4750 4750 4750 4750 4750 11 1 U92:B 1 16
12.1 R590 J23
J9 13 16 SHIFT_CLK QB 21 # DIGITAL OUT 18 -
REJ FAN TACH 8 11 X0 VCC +5V 2 15
L12 C32 9
COM
U91:H GND
8 12 2 U92:C R591 12.1 J23
J9 14 CR92 MC1413BD LATCH_CLK QC 22 # DIGITAL OUT 19 -
REJ FAN TACH 9 12 X1 0.1 3 14
L13 1SMB5939B 13 3 U92:D 12.1 R592 J23
J9 15 39V OE U90 QD 23 # DIGITAL OUT 20 -
REJ FAN TACH 10 13 X2 4 13
L14 MC74HC595AD 4 U91:A R593 12.1 J23
J9 12 16 QE 25 # DIGITAL OUT 21 -
REJ FAN TACH 11 14 X3 +5V VCC 1 16
L15 9 U62:H 8 5 U91:B 12.1 R594 J23
J9 1 COM GND C358 C368 10 QF 26 # DIGITAL OUT 22 -
REJ FAN TACH 12 15 X4 CR62 MC1413BD 0.01 0.1 RESET 2 15
L16 8 6 U91:C R595 12.1 J23
J9 5 1SMB5939B GND QG 27 # DIGITAL OUT 23 -
REJ FAN TACH 13 16 X5 39V
L17 7 U91:D 3 14
12.1 R596 J23
J9 2 QH 28 # DIGITAL OUT 24 -
REJ FAN TACH 14 17 X6 6 9 4 13
L18 C49 C50 C51 C52 C53 C54 C55 ENABLE SQH C366 C365 C364 C363 C362 C361 C360 C359 12.1
J9 7 9 U63:H 8 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
18 0.001 0.001 0.001 0.001 0.001 0.001 0.001 VEE COM GND
J9 CR63 MC1413BD
19 4 8 1SMB5939B
+5V X7 GND
J9 R102 C40 39V SHIFT_DIG_OUT
20 TO SHEET 7
4750 0.001
9 U34:H 8
S2060192 SHEET 6 OF 8 V5 COM GND
CR30 MC1413BD
1SMB5939B
39V
R419
15.0K
TP40
TP34 +5V
R286
1.21M
5 R301 R306
R254 4750 10.0K #SWR_SHUTBACK+
2
SWR_SHUTBACK_REF 10.0K U39:A TO SHEET
FROM SHEET 2
R310 R267 C159 4
0.0 10.0K 0.1
R492 R507
10.0K 10.0K
2 12 3
REFA DACA
3 C326 1 J24
REFB U77:A 34 ANALOG OUTPUT 5
R508 0.01 R558 C327 R559
4 10.0K 2
REFC 10.0 0.1 10.0
5 +5V
REFD U68
TLV5620ID R512 R513 12 +5V
6 10.0K 10.0K U38:D
14 R285
DATA R294
0.0 4750 R183
7 13 13
CLK U16:E 1000 U16:F
11 5
DACB U29:D
14 C293 7 J24 R277 5 12 6 11 14
+5V VDD U77:B 35 ANALOG OUTPUT 6 +5V
L34 C270 C275 R467 0.01 R446 C285 R447 0.0 R212 12
0.1 0.01 10.0K 6 10.0 0.1 10.0 +5V 4750
1 5
GND
13 R459 R460 7 R232 9
LDAC 10.0K 10.0K R362 U55:B U34:F 1000 U34:G
0.0 6 6 11 7 10
U29:C 8
+5V
DACC
10 10 R209 10
C294 8 J24 R358 4750
U77:C 36 ANALOG OUTPUT 7 0.0
R468 0.01 R449 C286 R448
#SS_6(DAC_3)- 8 10.0K
FROM SHEET 1 LOAD 9 10.0 0.1 10.0 +5V
+5V
R462 R461 R387
10.0K 10.0K 18.2K R392
U63:F 1000 U63:G
9 12 6 11 7 10
DACD
C307 14 J24
U77:D 37 ANALOG OUTPUT 8
R504 0.01 R561 C328 R560
10.0K 13 10.0 0.1 10.0
R246
R515 R514 0.0 8
10.0K 10.0K
S2060192 SHEET 8 OF 8 V5 U39:C 14
9
R278 R268
0.0 0.0
S14
J9 J2 A DS13 R DS14 A DS15 R DS16 A DS29 R DS30 A DS31 R DS32 A DS45 R DS46 A DS47 R DS48
# DIGITAL INPUT 15 - 6 17 # DIGITAL INPUT 15 -
15 E7:1 E7:3 E8:1 E8:3 E15:1 E15:3 E16:1 E16:3 E23:1 E23:3 E24:1 E24:3
STATUS ALARM STATUS ALARM STATUS ALARM STATUS ALARM STATUS ALARM STATUS ALARM
S15
J9 J2
# DIGITAL INPUT 16 - 4 19 # DIGITAL INPUT 16 -
16 E7:2 E8:2 E15:2 E16:2 E23:2 E24:2
S16 R7 R8 R15 R16 R23 R24
1500 1500 1500 1500 1500 1500
J9 J2
# DIGITAL INPUT 17 - 3 20 # DIGITAL INPUT 17 -
17 CR7 CR8 CR15 CR16 CR23 CR24
J1 J4 J1 J5 J1 J6
S17 # DIGITAL OUT 07 - 8 8 # DIGITAL OUT 07 - # DIGITAL OUT 15 - 17 6 # DIGITAL OUT 15 - # DIGITAL OUT 23 - 27 3 # DIGITAL OUT 23 -
J9 J2 J1 J4 J1 J5 J1 J6
# DIGITAL INPUT 18 - 2 21 # DIGITAL INPUT 18 - # DIGITAL OUT 08 - 9 7 # DIGITAL OUT 08 - # DIGITAL OUT 16 - 19 4 # DIGITAL OUT 16 - # DIGITAL OUT 24 - 28 2 # DIGITAL OUT 24 -
18
S18 J1 J2 J7 J3
6 6 5 5 J12 J1
J10 J2 J7 J3 EXTERNAL +15V SUPPLY 1 34 EXTERNAL +15V SUPPLY
# DIGITAL INPUT 19 - 8 22 # DIGITAL INPUT 19 - J1 J2 1 1 J2 J11
19 12 12 J13 J1 ANALOG OUTPUT 1 30 1 ANALOG OUTPUT 1
J8 J4 1 35
J1 J2 5 5 J2 J11
S19 18 18 ANALOG OUTPUT 2 31 2 ANALOG OUTPUT 2
J8 J4 J12 J1
J1 J2 1 1 2 36 J2 J11
J10 J2 24 24 ANALOG OUTPUT 3 32 3 ANALOG OUTPUT 3
# DIGITAL INPUT 20 - 7 23 # DIGITAL INPUT 20 - J9 J5
J1 J2 5 5 J13 J1 J2 J11
20 29 29 J9 J5
2 37 ANALOG OUTPUT 4 33 4 ANALOG OUTPUT 4
1 1
S20 J2 J11
J10 J6 +15V ANALOG OUTPUT 5 34 5 ANALOG OUTPUT 5
J10 J2 5 5
# DIGITAL INPUT 21 - 6 25 # DIGITAL INPUT 21 - J10 J6 J1 J14 J2 J11
1 1 +15V (REMOTE) 32 1 +15V OUT ANALOG OUTPUT 6 35 6 ANALOG OUTPUT 6
21 J1 C1 J14 J2 J11
33 1.0 RT1 2 +15V OUT ANALOG OUTPUT 7 36 7 ANALOG OUTPUT 7
S21 RXE090 J2 J11
J10 J2 ANALOG OUTPUT 8 37 8 ANALOG OUTPUT 8
# DIGITAL INPUT 22 - 4 26 # DIGITAL INPUT 22 - J14 J14
3 5
22 J14 J14
4 6
S22
J14
J10 J2 7
# DIGITAL INPUT 23 - 3 27 # DIGITAL INPUT 23 - J1
J14 30
23 8
J1
S23 31
J10 J2
# DIGITAL INPUT 24 - 2 28 # DIGITAL INPUT 24 - S2060183 SHEET 1 OF 1 V1
24
S24
**
B
R4 R10 R16
J1 50 50 50
REJECT POWER SAMPLE 2 2 250W 250W 250W
C2 CR2 ** R23 R22 *
R24 R5 R11 R17
3320 0.001 BAT54HT1 150 150 50 50 50
250W 250W 250W
R6 R12 R18
50 50 50
250W 250W 250W
**
C
R25 R31 R37
J2 50 50 50
REJECT POWER SAMPLE 3 3 250W 250W 250W
C3 CR3 ** R44 R43 *
J2 R45 R26 R32 R38
9 3320 0.001 BAT54HT1 150 150 50 50 50
J2 250W 250W 250W
10
R27 R33 R39
50 50 50
250W 250W 250W
**
D
R28 R34 R40
J2 50 50 50
REJECT POWER SAMPLE 4 4 250W 250W 250W
C4 CR4 ** R47 R46 *
R48 R29 R35 R41
3320 0.001 BAT54HT1 150 150 50 50 50
250W 250W 250W
R30 R36 R42
50 50 50
250W 250W 250W
S2060047 VC
5 IPA V B
A9 C IPA O/P PWR
L9 IPA
J
RF DRIVE IPA RF DRIVE F
J3 W3P1 W3P2 J9
* * A
PA DRIVE 1 F
W1P1 W1P2 J8
1 # POWER - 1
3 # MODULE FAULT - 3 PA V 1 B
A1 C PA O/P PWR 1
R4 PA 1 (0 )
100
R DS1:A G DS1:B 30W
J1 FLT PWR BIAS 1 A
R1 R2 L1
221 221
5 +5V 5 * * * B
L1 PA DRIVE 2 F
C7
4 GND 4 0.1
PA V 2 B
A2 C PA O/P PWR 2
PART OF R6 PA 2 (0 )
100
A10 40W BIAS 2 A
POWER MODULE L2
INTERFACE PWB
* C K * * * * C
IPA O/P PWR 0 DRIVE PA DRIVE 3 F
D L
A GND
PA VOLTS A + 37-56 1 IPA PWR PA V 3 B
A3 C PA O/P PWR 3
PA VOLTS B + 57-76 SAMPLE R13 C1 CR1 * R11 R12 R5 PA 3
0.001 1N5711 (0 )
B 3320 221 274 100
IPA VOLTS + 79-82 30W
FAN VOLTS + 77 BIAS 3 A
L3
FAN VOLTS + 78
+5V 20 * * D
PA DRIVE 4 F
-15V 22
GND 83 PART OF PA V 4 B
A4 C PA O/P PWR 4 TO SHEET 2
GND 84
A11 PA 4 (0 )
U1
A0 1 MODULE SPLITTER
PART OF BIAS 4 A
A1 3 PWB L4
A2 5
A12
COMBINER PWB * * E
A3 7 PA DRIVE 5 F
A4 9
# PA VOLTS INHIBIT - 30
PA V 5 B
A5 C PA O/P PWR 5
RF DRIVE 86 R7 PA 5 (-90 )
100
RF DRIVE 88 30W
GND 85 P1 2 +5V BIAS 5 A
L5
GND 87 6 GND
# PS FAIL A - 25 4 MOSI E M * * * * F
J4 -90 DRIVE PA DRIVE 6 F
# PS FAIL B - 13 3 SCK R1 F N
1 MISO 50 GND
# PS TEMP A - 29 250W PA V 6 B
A6 C PA O/P PWR 6
# PS TEMP B - 17 5 # RESET - R9 PA 6 (-90 )
100
# PS AC FAIL A - 27 40W
# PS AC FAIL B - 15 32 PA V SAMPLE BIAS 6 A
L6
# PS MODULE PRESENT A - 33 35 GND
# PS MODULE PRESENT B - 21 36 GND * * * G
PA DRIVE 7 F
SPARE 11 34 IPA V SAMPLE
31 # PWR SUPPLY INHIBIT A +
SPARE 23 P1 PA V 7 B
A7 C PA O/P PWR 7
INT TX/RX 24 19 # PWR SUPPLY INHIBIT B + R8 PA 7 (-90 )
8 # MODULE STATUS 100
INT TX/RX 26 30W
BIAS CURRENT + 2 16 IPA POWER SAMPLE BIAS 7 A
L7
BIAS CURRENT - 4 18 RF DRIVE SAMPLE
# RESET - 14 28 # MAIN AC FAIL - * * H
PA DRIVE 8 F
MOSI 12
SCK 10
1 PA V 1 PA V 8 B
A8 C PA O/P PWR 8
MISO 6 PA 8 (-90 )
1 BIAS 1
BIAS 8 A
1 PA V 2 L8
2 BIAS 2
2 PA V 3
3 BIAS 3
DENOTES TB1 2 PA V 4
* DENOTES A MICRO-STRIP TRANSMISSION LINE OF SPECIFIC
DENOTES TB2 4 BIAS 4 LENGTH AND CHARACTERISTIC IMPEDANCE.
3 PA V 5
DENOTES TB3
5 BIAS 5
DENOTES TB4
3 PA V 6
DENOTES TB5
6 BIAS 6
4 PA V 7
7 BIAS 7
4 PA V 8
8 BIAS 8
S2060204 V1
+48V
S2060205 V1 +48V
+48V
+48V
B
PA VOLTS
C16 C1 C3 C5 C8 C11 L1 C13 L3
1000 10 10 1.0 1.0 0.1 470pF
75V R3
20
2W
R4
20
2W
A
BIAS
R1 C9
15K 0.01 R5 R9
20 20
L7 2W 2W T3:A
Q1:A
T2:B L4
F L2 C
RF DRIVE T1 * T4 RF OUT
C2 C6 C15
G 15pF 100pF C10 C14 0.001
0.01 L5 0.001
D
R12 R13 Q1:B
C7 C17 10 10
56pF 15pF 2W 2W T3:B
T2:A
R8 R10
L6 20 20
E 2W 2W
R2 C12
15K R11
0.01 47.5K
S2060206 V2
P1 1 3
BIAS CURRENT + 2 RS+ N/C
C159 4
0.001 C158 GND
0.001 U11 6
N/C
P1 MAX4080SASA
BIAS CURRENT - 4
8
RS-
7
N/C BIAS CUR
C157 TP12
0.001
5 13
OUT X0
2 R88 C121
+5V VCC
C160 10.0K 0.1 16
0.01 1 VCC +5V
+5V X4 C129
R76 0.01
+5V 4750
TP18 13
R126 14 5
12.1K U37:D X5
J1 R95 C122
SPARE 2 12
L8 C51 R125 C53 100 0.1
R124
0.001 0.0 0.0 0.1
SELECT_A3 11
A
SELECT_B3 10
B
SELECT_C3 9
C
6
ENABLE
7
TP13 9 VEE
FROM SHEET 1 8 15 8
U29:C X2 GND
PA_VOLTS_B
R78
10 0.0
R109 R110 C100
121K 6810 0.1
TP10 13
4 U29:E 11 14 14 3 ADC1
+5V VCC VEE -15V PA_VOLTS_A U29:D X1 X
C105 MC33074AD C104 R85
0.1 0.1 12 0.0
R106 R107 C107
121K 6810 0.1
TO SHEET 2
4 U37:E 11
+5V VDD GND
C63 TLV2374ID
0.1 SCK 2 9 MISO
CLK QH
SHIFT/LOAD 1
FROM SHEET 2 SHIFT/LOAD 7
QH
QH 10
SA
U19
+5V +5V +5V +5V +5V +5V +5V +5V MC74HC165AD
CR8
S2060201 SHEET 3 OF 3 V3 P1
28 # MAIN AC FAIL -
CR6
R1 R4 CR2 J2
100K 100K STPS80L60CY 1 FAN VOLTS (MODULES 5 TO 8)
E1 A1 J2
FAN VOLTS (A) 2 FAN VOLTS (MODULES 5 TO 8) J11
K 1 IPA VOLTS CONTROL (C) +
E2 J2 J11
A2 3 2 IPA VOLTS CONTROL (C) -
FAN VOLTS (B) J2
4
E3 C2 C1 C3 C5 C4 C6 TP5 J7 J11
GND 0.1 0.1 0.001 0.1 0.1 0.001 19 3 # IPA PS INHIBIT (C) +
J7 J11
CR1 J3 20 8 GND
STPS80L60CY 1 FAN VOLTS (MODULES 9 TO 12)
A1 J3
GND 2 FAN VOLTS (MODULES 9 TO 12)
K J3
A2 3
J3 J8 J12
4 13 1 FAN VOLTS CONTROL (A) +
J8 J12
14 2 FAN VOLTS CONTROL (A) -
J4 J8 J12
PWB PART: HW1 1 FAN VOLTS (MODULES 13 TO 16) 11 3 # FAN PS INHIBIT (A) +
J4 J8 J12
HAQ36_T 2 FAN VOLTS (MODULES 13 TO 16) 12 8 GND
J4
PWB PART: HW2 3
HAQ36_T J4
4
J13
J5 1 FAN VOLTS CONTROL (B) +
1 FAN VOLTS (REJECT LOAD A) J13
J5 2 FAN VOLTS CONTROL (B) -
2 FAN VOLTS (REJECT LOAD A)
J5 J8 J13
3 19 3 # FAN PS INHIBIT (B) +
J5 J8 J13
4 20 8 GND
J6
1 FAN VOLTS (REJECT LOAD B/C)
J6 J9 J7
2 FAN VOLTS (REJECT LOAD B/C) 5 1 # IPA PS MODULE PRESENT (A) -
J6
3 J9 J7
J6 6 2 # IPA PS AC FAIL (A) -
4
J9 J7
7 3 # IPA PS TEMP (A) -
+12V(FAN V) J9 J7
TP6 4 4 # IPA PS FAIL (A) -
J8
3 +12V FAN V SAMPLE
R11
R10 1210
10K E9 J10 J7
5 9 # IPA PS MODULE PRESENT (B) -
+12V FAN V OUT
J10 J7
PWB PART: HW5 C16 C15 C14 6 10 # IPA PS AC FAIL (B) -
HAQ36_T 0.1 0.47 0.001 J10 J7
E10 7 11 # IPA PS TEMP (B) -
+12V FAN V RTN
R7 J10 J7
4 12 # IPA PS FAIL (B) -
100K Q1
# +12V DOOR FAN 4 J8 IRF540N
INHIBIT - R14 C17 R12
R13
1000 0.01 22.1K 1000 J11 J7
+12V(A) +12V(B) 5 15 # IPA PS MODULE PRESENT (C) -
TP3 TP4 J11 J7
6 16 # IPA PS AC FAIL (C) -
J11 J7
7 17 # IPA PS TEMP (C) -
R5 R8 CR4 J11 J7
10K 10K STPS80L60CY 4 18 # IPA PS FAIL (C) -
E4 A1
+12V IN (A) E7
K
E5 +12V SBC/AUI OUT +
A2
+12V IN (B) C12 C13 C11
C8 C7 C10 C9 E8 J12 J8
E6 0.1 0.47 0.001 GND 5 7 # FAN PS MODULE PRESENT (A) -
GND 0.47 0.001 0.47 0.001
J12 J8
6 8 # FAN PS AC FAIL (A) -
CR3
PWB PART: HW3 STPS80L60CY J12 J8
HAQ36_T A1 7 9 # FAN PS TEMP (A) -
K J12 J8
PWB PART: HW4 4 10 # FAN PS FAIL (A) -
A2
HAQ36_T
J8 J13 J8
1 +12V SBC SAMPLE (A) 5 15 # FAN PS MODULE PRESENT (B) -
R6 J13 J8
1210 6 16 # FAN PS AC FAIL (B) -
J8 J13 J8
S2060196 V1 2 +12V SBC SAMPLE (B) 7 17 # FAN PS TEMP (B) -
R9
1210 J13 J8
4 18 # FAN PS FAIL (B) -
+5V (B)
STATION E1 E5 E6 E7 V1 +5V (B)
REFERENCE GND TO ALL SHEETS TB2 1B
GROUND E1 J7 P6 L V2 +15V (B)
1 VAC (2-1B1)
E
L
E
L U4 V3 -15V (B)
2 VAC (2-1B2) N N LVPS B
N COM GND
1A TB1 1B 1A 3 VAC (2-1B3) E2
COM
LINE 1 1 1 VAC LINE 1A 1 4 VAC (2-1B4)
2 N/C 2B
E3
3 N/C 1 VAC (2-2B1)
J4 W7P1 VAC (3-2B4)
4 N/C 2 VAC (2-2B2) TO VARIOUS SHEETS L L
(SEE VAC REFERENCE) E E GND
2A 3 VAC (2-2B3) E4 N N
2A 2B VAC (3-3B4) TO RF
1 4 VAC (2-2B4) DRIVE STAGE
LINE 2 1 1 VAC LINE 2A
J8 W8P1 VAC (2-1B3) SHEET 1
2 N/C 3B
L L
FROM EXTERNAL 1 VAC (2-3B1) E E GND
3-PHASE AC 3 N/C N N
POWER SOURCE 2 VAC (2-3B2) VAC (2-2B3)
4 N/C
(312-457VAC)
380VAC NOM. 3A 3 VAC (2-3B3)
3A 3B 1 4 VAC (2-3B4)
LINE 3 1 1 VAC LINE 3A VAC (2-1B4)
X1
2 N/C
A
3 N/C DS1
4 N/C X2
VAC (2-2B4)
4A 4B VAC (2-3B4)
X1
NEUTRAL 1 1 NEUTRAL 1A 1A TB3 1B
2 NEUTRAL 2A 1 1 VAC (3-1B1) A
DS2
3 NEUTRAL 3A 2 VAC (3-1B2)
X2
4 N/C 3 VAC (3-1B3) VAC (3-1B4)
4 VAC (3-1B4) VAC (3-2B4)
X1
2A 2B
A
1 1 VAC (3-2B1) DS3
2 VAC (3-2B2) TO VARIOUS SHEETS
(SEE VAC REFERENCE) X2
3 VAC (3-2B3) VAC (3-3B4)
4 VAC (3-2B4)
3A 3B
1 1 VAC (3-3B1)
2 VAC (3-3B2)
3 VAC (3-3B3)
S2060214 V1 4 VAC (3-3B4)
Figure SD-1B: NV10/NV7.5 Transmitter - Ac-Dc Power Stage, 3-Phase, 312-457 V ac (Sheet 1B of 3)
2 VAC LINE 1B 2B E3
3 VAC LINE 1C 1 VAC (2-2B1)
4 N/C 2 VAC (2-2B2) TO VARIOUS SHEETS J4 W7P1 VAC (3-2B4)
(SEE VAC REFERENCE) E4 L L
2A 3 VAC (2-2B3) E E GND
N N
1 4 VAC (2-2B4) VAC (3-3B4) TO RF
FROM EXTERNAL
1-PHASE AC DRIVE STAGE
3B SHEET 1
POWER SOURCE J8 W8P1 VAC (2-1B3)
(180-264VAC) 1 VAC (2-3B1) L L
240VAC NOM. E E GND
2 VAC (2-3B2) N N
VAC (2-2B3)
3A 3 VAC (2-3B3)
1 4 VAC (2-3B4)
VAC (2-1B4)
X1
2A 2B
A
LINE 2/N 1 1 VAC LINE 2A 1A TB3 1B DS1
2 VAC LINE 2B 1 1 VAC (3-1B1)
X2
3 VAC LINE 3B 2 VAC (3-1B2) VAC (2-2B4)
1 1 VAC (3-2B1) X2
VAC (3-1B4)
2 VAC (3-2B2) TO VARIOUS SHEETS
(SEE VAC REFERENCE) VAC (3-2B4)
3 VAC (3-2B3) X1
4 VAC (3-2B4)
A
DS3
3A 3B
1 1 VAC (3-3B1) X2
VAC (3-3B4)
2 VAC (3-3B2)
3 VAC (3-3B3)
4 VAC (3-3B4)
S2060215 V1
Figure SD-1C: NV10/NV7.5 Transmitter - Ac-Dc Power Stage, 1-Phase, 180-264 V ac (Sheet 1C of 3)
Assembly detail drawings for assemblies and modules that have separate manuals are not
included. Refer to the appropriate maintenance manual for the assembly detail of these
assemblies.
When a module or assembly is the subject of its own assembly detail drawing, and it is also
shown in a higher level assembly, the detail depicted in the higher level assembly may have
minor differences from the module or assembly actually installed. In this case, always refer to
the assembly detail drawing of the module or assembly for detailed information.
1. When a part or assembly is assigned a reference designation (e.g., A2A1 or A2A1R1), refer
to the family trees in Section 3, “Parts Lists” on page 3-1. Follow the family tree
branches to the block that contains the desired reference designation and Nautel
nomenclature (e.g., NAPI104/03 Power Module Interface PWB). Note the reference
designations and Nautel nomenclatures of all higher assemblies in the path.
Example: A18 NAA56/01D RF Power Module > A18A10 NAPI104/03 Power Module
Interface PWB.
2. Refer to Table 6.1 on page 6-2. Use the reference designation and Nautel nomenclature
to identify the appropriate mechanical drawing.
Example: NAPI104/03 Power Module Interface PWB is shown on schematics MD-16.
3. If necessary, refer to the referenced figure (e.g., MD-16) in the mechanical drawings at
the end of this section and locate the next, lower-level assembly. Then, repeat this
procedure until the desired part or assembly is found.
CONTROL/INTERFACE PWB
AC DISTRIBUTION
ASSEMBLY
RF POWER MODULES
LVPS A (U3) and B (U4)
POWER SUPPLY
MODULES
EXCITER A (OPTIONAL)
EXCITER B (OPTIONAL)
REJECT LOAD
INTERFACE PWB
COMBINER/FILTER ASSEMBLY,
10 kW
RF DRIVE SPLITTER/CHANGE-
OVER ASSEMBLY POWER SUPPLY
DISTRIBUTION PWB
POWER SUPPLY
INTERFACE PWBs
C367
R597
A1 A2
R74
U1
SAMPLE
C357 R586
1 R598
R75
C310 R538
J18 J19
REFLD
FWD
J11 J14
R62
R39
C1
C311 R539
U74
11
C5
Q2
INTLK
1 LVPS R186 CR14 CR20 1 C312 R540
R227 R226
R233 R238
R239 R237
C141 TP39
R187 +12V
TB2
C142 FAN V TP44 C313 R541 C358 C368
2
L2
R339
R348
R405
R414
R144
A2 A1
C201
C247
C92 R272 L27 CR67 C314 R542
C38
C47
R329
R388
TP38
L19
C27 U14 R188 R357 R418
R194 R193
C143
3
K C315 R543
C93 L25 R313
U90
L20 C230
C113
R273 C182 C264 C316 R544
R336
U75
R398
4
L1 L10 C183
C48 R142 C214 C231
U45
R378 U61
C317 R545
C121
R215
C89 C155 C170 R419
R129
U69
C176
C184
R322
C219
C232
R379
R136 R145 DS2 DS3 C131 R274 R289 C265 C318 R546
5
R4 R85 C39
U51
U65
CR92
R327
C197
U3
DS1
CR68
R130 TP8 TP25 TP27
10
TP35
R244
1 R276 R291 U43
6
R6 C266
C185 C177
C225
C320 R548
U58
R63
C133
R242
C132
U5
C198
R24 R241 C158
U91
+5V +15V -15V C171 R380 C321 R549 GND
R64 GND LCL RMT
R328
R330
U70
U76
C2 R40 R65 C42 C94 R292 C212 R381 C267 C322 R550 1
U55
4
C239
3 2 1
U38
R349
C172 E19
U46
C28 R131 C323 R551
U23
R51 R345
C3 R66 R105 R293 CR93 R599
C90
C203 C324 R552
R401
C268
R178
R189
CR69
R294 R350 C369
J1
BT1
C29
R358
R362
C325 R553
R383
R382
R399
R277
C269
C274
R440
C282
C281
R53
C127
R190
L33
U92
R7 R41 C26 C69
OUTPUTS
REMOTE
C291
C299
R493 R492 R490 R488
R507 R491
R88 C75 R152 C97 R589
R10 R118 C359
U67
J2 R44 J9 R89 C76 R153 C98 U24 U73 R590
1
R11
+
R45 R119 C360
R12 R90 C77 R281 R296 R591
R120 R154 C99 R196 C361
R46 R91 R217 R245
1 R13
C128
R121 C78 R155 C100 R592
C283
C292
C300
R47 R92 R218 DS13 DS14 C362
1
R14
C102C101
R48 R93 R122 C79 R156 R197 RF ON RF OFF INCR PWR DECR RESET R593
R15 C145 C153 L26 C363
L12
R49 R94 R123 S2 S3 S4 S5 S6 R594
C275
R16 R50 C80 R157 U25 R459 C293 C301 R508
R17
C49 R95 C160 C364
C6 CR49 R512 R595
C270
C365
L34
R96 UNLABELLED REF DES R446 C302
C4 R38 L9 L8 L7 L6 L5 L4 L3
CONSECUTIVE NUMBERS R198 R219 U31
C50
C149
L13
U40 R558 R596
R19 R18
R460 R467 C326 R513
C129
TOP TO BOTTOM R199
C11 C10 C9 C8 C7
L14 C51 L22
CR58
R97
CR56
R559 C366
CR57
R346
8
R331
R351
R369
C81 TP16 R158 R447 C285 C327
R385
U68
C103 R220
U77
R282 C161
R98 R263
C52
L15
C216 CR59
CR60
C82 R159 C104 DS5 DS12 R448 C286 C328
R20
L16 C53 C146 R264 R560
R99
U26 C144 R320 C303
CR53
C83 R160 C105 LCL/RMT
R21
C189
R332
C199
R337
C206
R352
R372 R370
R561
R321
C54
L17
R100 C84 R161 C106 R221
S1 R449 R461R468 C307 R514
J23
CR50
R200
R22
C233
R101
TP41 R462 C294 C304 R504 R515
C130
C85 R162 C107 +4.096V
R201
L18 C55 C150
C240
R353
R23 U32 REF J15
C217
C205
C12
C187
R340
R371
EXT INT
C190
R222
R102
C86 R163 C108
C333
E9
C32
1
C70
L23 1
C220
CR70
R283
C194
R334
C162
C87 R164 C109 L35
R564
U27
R516
R298
U2
U8
R297
C208
C271
C263
C260
R420
C248
R406
C88 R165 C110
C334
U78
C40
R202 CR71
R475
TP43 TP46 TP54 RT3
7
R517
R565
FAN V PA V TP23 TP29
+12V
C163
1
FWD PWR SMPLREFLD GND
C173
R223
C174
GND
TP28TP26
R175 TP31TP30
C13 TP1
R476
TP4
C335
A
R54
R70
R69
C178
C222
C221
C234
C241
IPA V CR72
TP2 TP5 R252 R407 R416 C287
R174
R421
R518
R566
U47
R389
R402
B
TP52
R408
TP51
R284
R300
R299
TP56
J8
U79
C336
R146
R106 TP55 CR73
R55
R71
R76
R305
R477
R374
R391
R132 R137 U66
R519
R567
R107 TP45 TP48
TP49 R469
C33
C56 R138 R147
R494
R390
C122
R112 R253 R451
R225
R228
R324
R323
R354
R359
C223
C337
C57 C179 TP50 C261 CR74
CR17
R176 R180 R452 C290
U4 R113 C58
R568
R433
C134
R240
R243
C147
R520
Y1
R333
R343
R342
R341
C180 R470
C59 R148 R181 C114 R409
R434
C338
U80
R114 R149 C226
CR25
U59 R453
C123
C41 R410
C159
C164
C115
R254
R267
R286
R301
C71 CR44 C276 R471 CR75
C191
C195
R521
R569
R25 C14 R115 Y2 R411 C279
6 C116 C296
U29 R435
R495
R26 C15 U15
C250
C249
C339
TP37
L30
C43 R139 C117 CR18 R436 CR76
R27 C16
R479 R478
TP34 R306
R522
R570
R140 R150 R182 R209 TP40 C277
U71
R28 C17 R203
R246
R268
U81
U39
C340
R29 C18 R116 R177 R212 L36
C60 R166 R307 CR77
R523
C278
R571
R30 C19 C68
C254 C252
C253 C251
R496
L31
R108
R31 C20 U19
C341
C61 R463
R248
R109 R278 R472 CR78
R32 C21 C62
R524
R572
TP53
TP42
R110 C118 C151 CONTROL/
L32
R33 C22 C63 L28 INTERFACE
U82
C342
R111 C152 C175 C181
R34 C23 R169 CR79
R480
C64
C262 R417
FAN V U48 NAPC156
R525
R573
R412
R35 C24 R133 R170 U20 SER.
R497
Q1
5 U35
C119 R310
R396
C343
R36 C25 C72 IPA V CR80
R124
R526
R574
C65 R171 L24 C165
R413
J3 J10 R125 R172
1
1
C66 C124
U83
C344
C73 CR81
U21
R481
R205 R269
J24
RF DRIVE SPLITTER R72
R527
R575
C125 R234 C154
R498
R303
R317
C137
R318
C345
CR2
C188
R375
R386
UNLABELLED TP36 CR82
REF DES R270+2.5V
R528
R576
CONSECUTIVE C148 REF J16 1
U6
1
NUMBERS
CR1
U22
U84
TOP TO
C346
L21
C200
C207
L29
BOTTOM CR83
J4
U33
R128
R529
R577
TP3
C67
C34
R78
R77
RF DR CR6 C126 TP47
R499
4
C347
RT1
R183 CR84
R483 R482
C235 C243
R206
R530
R578
U30 U36 U41 C255
U85
R56
C348
CR85
U16
R531
R579
C256
L11
1
C139 C166 C192 U60
R500
R57
RT2
R304
C349
U50 C257
R58 1
TP32 C140 CR86
C95 C193
R580
R532
R80 R79
R404
R191
C167 FWD PWR
CR23
CR26
CR27
C111
J5
METER
U86
R256
C350
R422 (% OF MAX) CR87
R285
R485
R59
REMOTE
R533
R581
R86
INPUTS
U9
U17
R423 DS15 LIMIT
R501
R141
CR12
CR19
CR29
C236 100%
U62
C351
DS16
3
R81
A C44 C209 R424 CR88
C242 DS17 90%
R534
R582
R192
R208
R231
EXCTR C210
ALARMS R425 DS18 80%
U10
U87
C352
B R258
C35
CR89
R486
DS6 SUMMARY R355 DS19 70%
CR62
R426
U57
R82
R535
R583
CR7 CR13
DS7 OUTPUT NETWORK DS20 60%
U52
R502
R60
R259 R427
U11
C353
DS8 IPA/PA TP57 DS21 50%
C36
R236 R257 GND CR90
J6
R428
R61
R536
R584
R260 DS9 EXCITER DS22 40%
U63
R83
R261
LAN
R387
R392
DS10 POWER SUPPLY R429 DS23 30%
U88
U12
C354
K1 K2
R87
CR91
R487
EXTERNAL 20%
U34
DS11 DS24
R537
R585
R262 R430
DS25 10%
R503
R84
C45 R335 R377
C355
R587
C224 R431
C168
2
J21
R232
R562
INTLK OVRD C169 CR63 R432
U37
WD RESET EXCTR A EXCTR B
J7
U89
U44 U56 CR94
C297
C289
C298
1
C211
C213
C218
CR30
R505
R489
1 E5 1 E6
R563
DSBL ENBL DSBL ENBL GRID1
C120
C46
C356
R588
R338
R450
U64
C37
5
CR95
C91
1 SYS CTRL A
R2 C237
R344
C196
C305
4
C244
S7 U13 U18 U28 C308
3 U53 U72
C112
SBC R311 C258 C272
J22
2 R325
RESET R213 RT4
C309
C238
R207 1 C273 R466 R484
EXCTR INTLK
A B 1 LAN (SBC) R214
A B C D E R326 1 SYS CTRL B
R312 R347 R356R360 R455 C306
COM
COM
1
N/O
N/O
STREAMING BUS (AUI)
N/C
1
N/C
1 1
EXTERNAL
1 2 3 4 5 6 SERIAL BUS
TB1
J13 J17 J20
DEBUG
(RS-232)
J12 J25
M2060193 V3
A B C D E F G H I
CR13
CR17
CR21
1 1 1 1 1 1
CR1
CR5
CR9
R1 R5 R9 R13 R17 R21
C1
E13
E17
E21
E1
E5
E9
DS1 DS9 DS17 DS25 DS33 DS41
01 DS2 05 DS10 09 DS18 13 DS26 17 DS34 21 DS42
GND 06 05 04 GND 03 02 01
TRANSMITTER AUDIO EXTERNAL VERY LOW CHANGEOVER
8
PRESET 1
J3-3
J4-6
J5-8
J5-3
J6-6
READY LOSS FAULT FWD POWER
J3-8
STATUS ALARM
7
STATUS ALARM ALARM ALARM
6
CR10
CR14
CR18
CR22
1 1 1 1 1 1
CR2
CR6
R2 R6 R10 R14 R18 R22
6
E10
E14
E18
E22
E2
E6
5
DS3 DS11 DS19 DS27 DS35 DS43
J7
02 DS4 06 DS12 10 DS20 14 DS28 18 DS36 22 DS44
4
RF ON PRESET 2 HIGH HIGH PWR SUPPLY
J3-7
J3-2
J4-4
J5-7
J5-2
TEMP REFLD PWR FAULT
3
J6-4
STATUS STATUS
ALARM ALARM ALARM
2
CR11
CR15
CR19
CR23
1 1 1 1 1 1
CR3
CR7
R3 R7 R11 R15 R19 R23
1
E11
E15
E19
E23
E3
E7
DS5 DS13 DS21 DS29 DS37 DS45
03 DS6 07 DS14 11 DS22 15 DS30 19 DS38 23 DS46
J1
REMOTE PRESET 3 SUMMARY OUTPUT IPA / PA LOW BATT /
J5-6
GND 12 11 10 GND 09 08 07
J3-6
J4-8
J4-3
J6-8
J6-3
5
8
STATUS STATUS ALARM NETWORK FAULT MEM FAIL
FAULT ALARM ALARM ALARM
7
CR12
CR16
CR20
CR24
1 1 1 1 1 1
CR4
CR8
6
R4 R8 R12 R16 R20 R24
E12
E16
E20
E24
E4
E8
DS7 DS15 DS23 DS31 DS39 DS47
5
04 DS8 08 DS16 12 DS24 16 DS32 20 DS40 24 DS48
J8
ACTIVE INTERLOCK LOW FORWARD EXCITER
4
PRESET 4 AC FAULT
J3-4
J4-7
J4-2
J6-7
J6-2
EXCITER OPEN POWER FAULT
J5-4
STATUS ALARM
3
STATUS ALARM ALARM ALARM
2
STATUS ALARM
REMOTE INTERFACE
4 1 1
1
NAPI115 AMBER RED
SER.
INPUTS
RT1
GND 18 17 16 GND 15 14 13
8
01 05 09 13 17 21
EXCITER
7
PRESET 2
J10-6
J7-8
J7-3
J8-6
J9-8
J9-3
RF ON B SELECT
6
SELECT
3
J9
4
S2 S6 S10 S14 S18 S22
02 06 10 14 18 22
3
POWER PRESET 3
J10-4
J7-7
J7-2
J8-4
J9-7
J9-2
RF OFF
2
INCREASE SELECT
1
J2
S3 S7 S11 S15 S19 S23
03 07 11 15 19 23
2
GND 24 23 22 GND 21 20 19
8
POWER PRESET 4
J10-3
J10-8
J7-6
J8-8
J8-3
J9-6
RESET
7
DECREASE SELECT
6
5
J10
S4 S8 S12 S16 S20 S24
04 08 12 16 20 24
4
EXCITER PRESET 1 AUTO
J8-2
J10-2
J10-7
1
3
J7-4
J8-7
J9-4
A SELECT EXCITER
SELECT CHANGEOVER
2
1 EXT +15V IN +15V OUT GND GND ANALOG OUT
1
+ - + - 01 02 03 04 05 06 07 08
1 2 1 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
M2060184 V1
A B C D E F
PA MODULE
ASSEMBLY
EXGINE PWB
LED PWB
BACK VIEW
TOP VIEW
A1
J7
J8
1
J4 1
J3 1
J2 1
J1 1
J6 1
J5 E7 E9
E8
MODULES MODULES MODULES MODULES REJECT REJECT
13 - 16 9 - 12 5-8 1-4 LOAD B/C LOAD A
FAN VOLTS FAN VOLTS +12V SBC/ GND +12V FAN C14 +12V FAN
R7 AUI OUT V OUT V RTN
C15
C16
C11
C12
C13
CAUTION:
3
R10
R11
HEATSINKS
MAY BE LIVE.
DO NOT GROUND. S D G
CR1 CR3 Q1
1
A1 K A2 A1 K A2
R12
TP5
C17
R1
R4
R5
R6
GND
TP6
R2
R3
R13
FAN V (B)
+12V
R8
R9
2
FAN V (A)
1 E1 E3 E2 E4 E6 E5
A B C D E F G H I J K
2 20 23 44
J1
(U/S)
C5
C6
E1 C1 V-
V+
C4
TP1 TP2 TP3 TP4 TP5 TP6 TP7
A B C D E
PP54 ISS.A
RF MONITOR
PWR PROBE
R2
PWR PROBE
R2
R1
RF SAMPLE
R1
206-6522
206-6524
A3 A1, A4, A5
R3
R3
J1 (U/S) J1 (U/S)
A2
M2060072 V1 M2060070 V1
PP49 ISS.A
PWR PROBE
R1
206-6520
REFLD
R3
J1 (U/S)
M2060071 V1
1
1
J2
C1 C2 C3 C4
1
TP1 FAN V
J4 RT1 RT2 J5 RT3 J6 R1 RT4 J7
1
1 1
J3
1 1
REJECT LOAD 1
INTERFACE (4-WAY)
ASSY 206-4084
M2060051 V1
A B C D E F G H I J K L M
R10
R13
R14
R1
R2
R5
R6
R9
TP1 TP2
6 IPA
PWR
RF D TP3 TP4 TP5 TP6 TP7 TP8 TP9 TP10 TP11 TP12
DR D
J10
J14
J5
J1
1
1
R11
R12
R15
R16
R7
R8
C13
C1
C5
C9
ADDRESS J3 E5 ADDRESS J7 E9 ADDRESS J12 E14 ADDRESS J16
A A A A
(UPPER)
1 (UPPER) 1 (UPPER) 1 (UPPER)
F01 F01 F01 F01
4 1 TERM N/C 1 TERM N/C 1 TERM N/C 1
AB E
AB E
AB E
AB E
23 6
23 6
23 6
23 6
CD
CD
CD
CD
C10
C14
C2
C6
45
45
45
45
B B B B
(LOWER)
789
S1 (LOWER)
789
S2 (LOWER)
789
S3 (LOWER)
789
S4
E2 J4 E6 J8 E11 J13 E15 J17
E4 E8 E13 E17
1 1 1 1
CLSD OPEN CLSD OPEN CLSD OPEN CLSD OPEN
C11
C15
C3
C7
C12
C16
C4
E7 C8 E12 E16
E3
2
R3
R4
E1 MODULE BACKPLANE
88 87 88 87 1 88 87 88 87
1
TERM N/C J9 NAPI111
SER.
E10
C17
1
J2 J6 J11 J15
C18
RF DRIVE RF DRIVE RF DRIVE RF DRIVE
M2060011 V2
A B C D E F G H I J K L M N O
COMBINER
PWB
PA PWBs
(A1 - A8)
IPA PWB
(A9)
MODULE
SPLITTER
PWB
COOLING
FANS
A12 A9 A13
L2
A21
A19 A22
A23 A24
A20
A1 A4
‘B’ A5
‘A’
A16
Q1 ‘C’
A15
‘D’
TB1
1
TEMP
HTSK
C2
R2
R1
A
J4
3 2 1
L1
C1
TP2 HTSK GND FWD
M2060202 V3
R140
L2
C3
Y1 C63 C62
R3
CR30 C4
C61
R5 R4 C64
C5
C6 R141
DS1 R10 C7
R9 R142 C65
OK
CPU
R7 C190
R6 R175
C9
C8
R8
TP1
R11 C67
FWD
C10
C66
U3
R12 C11 C68
R13 C69
R143
B
U4 C71 C70
R15
U5
R144
U6
R17 C77 C76
R21 R20 C75
C74
R19 C79
C78
IPA PWR R22 R145
SER.
R23 C81
HIGH REJ
TP26
R146
R176 C80
TP7
C82
NAPI104
R24 C84
R25
C86
U7
C83
CR18
U8
C89 C87
INTERFACE
R26
C85 C88
R28
R29
C91 R147
C12
TP5
C14 C93
TP6
R148
C90
R30 C92
POWER MODULE
U38
C15
C13
C96 R149
REJ R31
C95
C94
C17
REFLD C18
R32
L5
L4
C
R182 R181 C97
R150 C98
L3 1
L6
GND
C100 C99
TP27
R151
C19
C24 C105 C103
R183
C23
C104
C101
2
RT2
C102
C107
TB2
RT1 C106
PWR
R152
3
R153 C108
U9
R33 C111
R34
TB3 POS 1-8 C26 U11 R154
1
PA BIAS 1-8 R35
C27 R36 R155 C112
P1
U12
CR4
R37 2
R39 R38 C114
D
U13
R46
R45
R44
R43
R41 R156
C113
C28
CR5
U16
U15
R53 C119
U14
R51 R52
C32
C34 R56 R55 C33 R54
CR20
C35
TB3
R59
R57
C36
U17
R64 C122
R60 R63
R66
E
C40 R69
CR23
U19
C47
R85 R160
C133
R93 R92
CR25
R98
L8
CR28 CR27
CR9
F
C147
R165
Q1
R100
R101
U25 C148 CR29
TP14
CUR1
C151
1 2
PA V 3 C153
R168
R103 R102 C154
R167
CR10
R170 R169
U26
R172 R171
P2
C156 C155 1
TP15
CUR3
Q2
3
PA V 5
C157
R174 R173
GND
TP16
TP20
TP10
CUR5 R104
R105
PA V A
U27
C158
Q3
C160
4
PA
PA V 7
G
C159
R107
TP13
R108
R106
V B R109
U28
U29
1
PA V 2
J2
R111
U30
C161
2
PA V 4
CUR7 CUR2
C192
R110TP17 TP19
H
CR11
U31
C168
C166
3
U32
TP21
L11 R113
L9
L14
L13
L12
CUR4
L10
4
R115 R120
CUR6
C183
R121
C52
R122
5
TP18
IPA V C184
C179
C178
C177
TP4
L15
C53 IPA V
I
C185
R127
C54
R129
C186
C55
R131
6
U36
C188
C187
R130
U37
C57
L16
R128 C56
88 C189
TP24
IPA CUR
R133 R132 C58
TB5
R135 C59
J3
R134
R136
TP25
R138
R137
CR17
RF DRIVE
RF DRIVE
J
REAR
FRONT
MD-16
Figure MD-16: NAPI104/03 Power Module Interface PWB
PA DRV 1 PA DRV 2 PA DRV 3 PA DRV 4 PA DRV 5 PA DRV 6 PA DRV 7 PA DRV 8 J
A B C D E F G H
R4 R5 R7 R8
J8
J9
1
PWR
L1
C7
G
R R6 R9
R1
FLT
R2
DS1
R3
TP1
FAN V
ENABLE
3
S1
2
K MODULE SPLITTER M
1
INHIBIT L NAPI105 N
0 -90
DRV SER. DRV
1
C1 C2 C3 C4 C5 C6
J7
M2060073 V2
11
10
CR1
A
R13
C1
B
9 R12
R11
6
C E
0 -90
DRV DRV
OUT OUT
D F
5
COMBINER
ASSY 206-1150
R20
R21
G H
4
R14
C2
CR2
R15
R16
CR4
C4
3 COMB REJECT
RF OUT LOAD
R22
P M
N
R17
R18
CR3
2 J
C3
R19
K
RT1
(U/S)
L
1
-90 RF OUT 0 RF OUT
M2060016 V1
A B C D E F G H I J K L M N O P Q R S T U V W
AUI. The Advanced User Interface is the 17-inch front panel that allows for extensive control
and monitoring of the transmitter.
Foldback. A reduction in RF output power, caused by transmitter not acheiving the desired
set point power level (typically this is related to high VSWR).
HD Radio. High Definition (HD) Radio is another term for In-Band-On-Channel (IBOC)
technology. HD Radio is a trademark of iBiquity Digital Corporation.
IBOC. Nautel In-Band-On-Channel technology provides high quality digital audio over existing
FM radio channels.
Intermediate Power Amplifier (IPA). Refers to circuitry within the transmitter’s RF power
modules which amplifies the exciter's RF output to a level sufficient to drive the final RF
amplifiers.
MER. Modulation Error Ratio. This ratio quantifies (in decibels) the performance of a digital
radio transmitter.
OFDM. Orthogonal Frequency Division Multiplexing is a digital data encoding method that
uses multiple narrowband carrier frequencies.
Preset. A setting that controls power level, frequency and audio parameters. The NV10/
NV7.5 allows you to pre-program multiple presets.
SBC. Single Board Computer. Refers to the CPU and associated components located on the
back of the transmitter’s front door.
Shutback. A complete, but temporary loss of RF output power, caused by any one of a
variety of faults, including high VSWR, high reject load power, RF drive failure, or an open
external interlock.
Shutdown. A complete and permanent loss of RF output power. Typically follows repeated
cutback, foldback or shutback events.
Surge protection panel. An electrical panel that protects equipment from electrical surges in
the ac power supply, antenna or site ground caused by lightning strikes.
TCP. Transmission Control Protocol. This is a connection based message delivery protocol that
provides error-checked delivery of a stream of data.
UDP. User Datagram Protocol. This is a connectionless based data delivery protocol that
doesn't provide error-checked delivery acknowledgement.
VSWR. Voltage standing wave ratio. This is an expression of the ratio of forward voltage to
reverse voltage on the feedline and antenna system. An ideal VSWR of 1:1 provides maximum
transmitter-antenna efficiency.
Document: NHB-NV7.5-NV10-TRB-3.3
Nautel Limited
10089 Peggy’s Cove Road
Hackett’s Cove, NS Canada B3Z 3J4
Toll Free: +1.877.6NAUTEL (662.8835)
(Canada & USA only) or
Phone: +1.902.823.3900 or
Fax: +1.902.823.3183
Nautel Inc.
201 Target Industrial Circle
Bangor, Maine USA 04401
Phone: +1.207.947.8200
Fax: +1.207.947.3693
Email: support@nautel.com
Web: www.nautel.com