CSI 2117A Series: Collector

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DataSheet

DS2117A
05/02 dll
RBMCOLLECTOR

CSI 2117A Series


FEATURES & BENEFITS

• 3,200 line resolution

• Built-in demodulator

• In-field alarm capability

• Ten-hour battery capacity

• Interfaces with CSI's advanced software tools

Alarms and analysis parameters are not generic but can


be custom defined for every different machine type in the
plant. When an alarm is detected in any of the analysis
parameters, the same route can then be loaded into a
higher level analyzer such as the 2120A for detailed signa-
The 2117A series provides an entry level platform for ture analysis.
vibration monitoring and condition analysis. The 2117A
series is available in three upgradeable levels that fit Upgrading to the 2117D1 (data collector, single channel)
seamlessly with the rest of CSI's route based Vibration adds the ability to collect Time Waveform and Frequency
products. Spectrum signatures. The 2117D1 provides up to 3,200
lines of spectral resolution for distinguishing closely relat-
The 2117P1 (parameter collector, single channel) is a ed fault types. Signature data can be reviewed in the field
route based vibration parameter collector. The P1 for on the spot analysis.
processes complex machine vibration data and reduces it
to an Overall level along with 12 other parameters Upgrading to the 2117A1 (analyzer, single channel) adds
focused on specific fault types. the ability to configure and acquire additional analysis
parameters in the field after a problem is detected. It also
• Demodulation provides earlier detection of antifriction provides Off-Route setup for additional machines or
bearing defects. measurement points that were not included in the route.
• Peak and phase trend parameters help diagnose sleeve
bearing condition. Any level of the 2117A series can be expanded to include
• Configurable frequency bands detect Imbalance, field balancing with FastBal I or II.
Misalignment, Gear defects, Belt defects, and other Weighing in at only 3.1 lbs (1.41 kg), the 2117A series
fault types. meets your needs for a fast, light-weight data collector
• Waveform parameters detect impacting or transient with full feature capability.
vibration that could be missed with just frequency band A 10 hour constant usage battery capacity (12 hours typi-
parameters. cal use) provides extended data collection without
• Additional process parameters can be measured recharge, eliminating concerns about mid-route battery
directly as voltage inputs, or entered manually with the failure. In the event of battery failure the data is safely
keypad, or through the use of predefined notecodes. stored.
The P1 is simple to use, even with no vibration analysis The 2117A series interfaces with CSI's advanced software
experience, to collect routine trend data. tools for vibration-based condition monitoring.
• Field alarming on all parameters immediately informs Additional accessories can be connected including tem-
you when a problem is detected perature probes, current clamps, thickness gauge, strobe
• By reviewing which parameter is in alarm you can tell light, etc. to expand your program beyond just vibration
what kind of fault is likely causing the vibration analysis.

TM

www.CSImeansReliability.com
DataSheet
DS2117A
RBMCOLLECTOR 05/02 dll

CSI 2117A Series Technical Specifications


AUTORANGING
The Model 2117A series automatically scans the input signal for Trigger: Tach or Vibration Level
each measurement. It sets the input range to maximize the
Frequency: Hz, CPM, Order
dynamic resolution while maintaining the dynamic range of the
A/D converter at 72 dB. Full-scale ranges from 21 V to 8 mV are Built-in Demodulator: Selectable filter
supported. Noise floor is typically less than 4 µV for a 400-line Units: Metric or English, acceleration, velocity, displacement, or user
spectra taken using a 1,000 Hz maximum frequency. programmable
Scaling: Linear or log, in both X and Y axes
FREQUENCY ANALYSIS Windows: Hanning or uniform
Range: DC-10 Hz (minimum) DC-30 kHz (maximum). Range is con- Cursor: Single or harmonic
tinuously adjustable. Integration: None, single, or double
Averaging: Normal, peak hold, order tracking, and synchronous Bar Code Reader Support: Connector standard
time. MEMORY CAPACITY
Response: Low frequency response is flat to DC for non-integrated
Standard Memory: 1,536 k (1.5 Mb)
signals. The signal may be single or double integrated with a low
frequency break at 3.5 Hz for each stage of analog integration or Number of Spectra Stored:
selectable break for digital integration. Data Type
A/D Converter: 12 bits of accuracy Overall level plus
Dynamic Range: 72dB six narrow bands: 9000
Number of Averages: 1 to 9,999 100 line spectra 3600
Resolution: 100, 200, 400, 800, 1600, 3,200, 1/3 octave 200 line 2600
Anti-aliasing: 7-pole elliptical filter 400 line 1700
800 line 1000
DATA ANALYSIS TIME 1600 line 520
Autoranging 1.0-3.0 sec 3200 line 280
100 line 8.7 avg/sec
200 line 4.5 avg/sec
400 line 2.2 avg/sec PHYSICAL DATA
800 line 1 avg/sec Height: 8.63 inches (219 mm)
1,600 line 0.4 avg/sec Width: 6.75 inches (170 mm)
3,200 line 0.2 avg/sec Depth: 1.6 inches (42 mm)
Real-Time Rate 800 Hz Weight: 3.1 lbs. (1.41 kg)
(Real-Time Rate is for a 400 line spectrum with range of 2,000 Hz
at 67% overlap.) OPERATING DATA
Input Signals: Two milliamp ICP type power supply inside the Temperature: 15° to 120 F (-10° to 50ºC)
º

instrument powers sensors such as accelerometers. Power supply Humidity: 0-95% noncondensing
provides 2 milliamp constant current at 20 volts nominal. ICP Safety Ratings: Consult factory
power may be used or bypassed depending upon type of input POWER SUPPLY
selected. Battery: NiMH
ICP Used: +/- 9 V Capacity: 2,700 ma-hr
ICP Bypassed: +/- 21 V Voltage: 7.2 V
Battery Life: 10 hours min. for constant use (12 hr. typical)
Input Impedance: Greater than 150 k ohms
Charging: 12-14 hour charge time.
Full scale vibration level depends on the type of sensor used and its Features: Data are not lost in the event of low battery voltage.
sensitivity. Full-scale vibration level is +/-90 g’s when using an
accelerometer with a sensitivity of 100 mV/g. DISPLAY
Type: LCD, supertwist liquid crystal display
OUTPUT
Display Size: 2.75 x 5.0 inches, 70 x 127 mm
Communication with Host Computer: 300 to 76,800 baud, user
selectable. By direct cable or modem. Standard software interface, Contrast: User adjustable
Virtual Printer allows you to print 2117 data from any Microsoft® Backlight: Can be turned on/off by user
Windows-supported printer. Pixels: 128 x 256
ANALYZER CAPABILITIES Standard Accessories: coiled accelerometer cable, accelerometer,
leather case, power supply, super magnet, storage case, communi-
Dynamic Analysis: Spectra, waveform, overall level, 1/3 octave
cation cable
(with or without A-weighting) and phase.

World Headquarters
The Emerson logo is a trademark and servicemark of Emerson
835 Innovation Drive • Knoxville, TN 37932
Electric Co.
Phone: (865)675-2400 • Fax: (865)218-1401
http://www.CSImeansReliability.com ©2002 CSI All rights reserved. The CSI logo and RBMconsultant
CSI Europe are trademarks of CSI Technology, Inc. Reliability-Based
Interleuvenlaan 50 • B-3001 Leuven • Belgium Maintenance and RBMware are registered trademarks of CSI
Phone: 32-16-741-403 • Fax: 32-16-400-457 Technology, Inc.

You might also like