CRP (C-reactive Protein) Rapid Quantitative Test CRP
CRP is a protein found in the blood, the rise of CRP levels response to inflammation. Combination of CRP
and blood routine test increases diagnosis accuracy.
● CRP control
Performance:
250.0
CONTENTS
100.0
50.0
Linear range 0.5 – 200 mg/L
0.0
0 50 100 150 200 250
Reference value hsCRP<1.0, CRP<10
DN-100 Special Protein Analyzer
Application:
● Infection Markers: CRP, PCT
Infection
CK-MB, H-FABP, 3 in 1 Nephrology Respiratory
differentiation Disease
monitoring
● Fluorescence signaling, higher sensitivity and specificity SEVERE Disease Test item
INFECTION SIRS Trauma
SEPSIS
● Preferred indicator of bacterial infection and sepsis HF NT-proBNP
Burns
● PCT control ACS cTnI, Myo, CK-MB
60.00
Linear range 0.1 – 100ng/mL cTnI
Diagnosis suggestion of myocardial injury markers
40.00
Concentration
Specimen type Whole blood/Serum/Plasma <2h H-FABP+Myo
YBRAHMS =0.180+1.006 X wondfo
20.00 CK-MB
MYO
Precision CV≤15% R2 =0.988
n =417 2-6h H-FABP+Myo+cTnI+CK-MB
0. 00
Prognosis Dynamic
evaluation monitoring Mix
● Sepsis indication, MODS prognosis ● Severity monitoring of servious patient 15min
● Clinical observation of antibiotic treatment ● Monitoring of postoperative infection
Wondfo (mg/L)
8
● Quantitative detection 2
Plasma 18uL
Plasminogen
Intrinsic Exogenous Whole blood 15uL
Characteristic: Characteristic:
● MAU control ● Better time fault tolerance—no remarkable difference in 5-30min test results
Performance: 20.0
y=0.9888x+0.1215
Performance: 350 Performance Technical Specifications 15.0
300 y=0.975x+0.154 R2=0.9702
Wondfo (mg/L)
Bio-Rad D10
250 R2=0.977 Reaction time 5 minutes n=183
Reaction time 10 minutes 10.0
200
Test time 10 seconds
Specimen volume 10 uL 150
100 Linear range 4.5 ~ 14.5% 5.0
Linear range 5 – 300mg/L 50
0 Cutoff value 6%
Specimen Urine 0.0
0 100 200 300 400
Precision CV<10% 0 5 10 15 20
Precision CV≤15% QuikRead (mg/L) Wondfo
Compared with 183 test results of HbA1c specimens (whole blood)conducted by Bio-Rad D10 automatic
analyzer, Wondfo FinecareTM FIA System has high accuracy in HbA1c test (4.5~14.5%), the correlation R2>
Application: 0.97, which can satisfy the clinical requirement.
Application:
● Early diagnosis and treatment management ● Indication to cardiovascular injury
of Diabetic Nephropathy of hypertension. ● Evaluation of long-term blood glucose ● The prediction of diabetes and early
Diabetic Hypertension
control Prediction warning for T1DM and T2DM
Nephropathy Dynamic
and
monitoring complications
warning
Characteristic: Characteristic:
120 y=0.9997x+0.2523
450
y=1.0004x+1.8538 Performance: R2=0.994
Performance: 400 R2=0.9945 100
Wondfo-PSA
350
Wondfo-AFP
80
300 Reaction time 15 minutes
Reaction time 15 minutes
250 60
Test time 10 seconds
Test time 10 seconds 200 40
150 Linear range 2– 100 ng/mL
Linear range 5 – 350 ng/mL 20
100
Cutoff value 4 ng/mL
Cutoff value 20 ng/mL 50 0
0 Precision CV≤ 15% 0 20 40 60 80 100 120
0 50 100 150 200 250 300 350 400 450
Roche-PSA
Roche-AFP
Compared with 629 test results of AFP specimens conducted by Roche, Wondfo FinecareTM FIA System Compared with 829 test results of PSA specimens conducted by Roche, Wondfo FinecareTM FIA System
has high accuracy in AFP test (5-350 ng/ml), the correlation R2=0.9945, which can satisfy the clinical has high accuracy in PSA test (2-100 ng/ml), the correlation R2=0.994, which can satisfy the clinical
requirement. requirement.
Application: Application:
● Liver diesease ● Early diagnosis of primary liver ● Prostate disease ● Early diagnosis of prostatic cancer