Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

Supply Target ΔH Heat Capacity

Stream Type
Temperature Temperature (MW) Flowrate Cp
Reactor 1 Feed Cold 20 180 32 0.2
Reactor 1 Product Hot 250 40 -31.5 0.15
Reactor 2 Feed Cold 140 230 27 0.3
Reactor 2 Product Hot 200 80 -30 0.25

HEAT EXCHANGER NETWORK (HEN DESIGN)

250
2
HOT STREAM
200
4
3
180 2
1
COLD STREAM
230 H
3
190 155

SOAL:
1. Hot stream 4 dipasangkan dengan cold stream 1
2. Hot stream 4 dipasangkan dengan cold stream 3
3. Hot stream 2 dipasangkan dengan cold stream 3
4. Hot stream 2 dipasangkan dengan cold stream 1
5. Hot stream 4 dipasangkan dengan cold stream 1

SOAL 1 ΔH 4= 12.5 kW
ΔH 1= 8 kW semua energi terpakai
T 4= 182 C
SOAL 2 ΔH 4= 4.5 kW
ΔH 3= 27 kW semua energi terpakai
T 3= 155 C
SOAL 3 ΔH 2= 15 C
ΔH 3= 22.5 C semua energi terpakai
T 3= 190 kW
Heater ΔH = 12 C
energi heater yang dibutuhkan lebih besar dari Qhmin, heater berada di stream 3
SOAL 4 ΔH 2= 16.5 kW
ΔH 1= 24 kW semua energi terpakai
T 1= 57.5 C
SOAL 5 ΔH 4= 17.5 kW
ΔH 1= 7.5 kW semua energi terpakai
T 4= 120 C
Cooler ΔH = 10 kW
energi cooler yang dibutuhkan lebih sama dengan QC minimal, cooler berada di stream 4

Supply Target ΔH Heat Capacity


Stream Type
Temperature Temperature (MW) Flowrate Cp
Reactor 1 Feed Cold 20 180 32 0.2
Reactor 1 Product Hot 250 40 -31.5 0.15
Reactor 2 Feed Cold 140 230 27 0.3
Reactor 2 Product Hot 200 80 -30 0.25

Hot Stream Plotted Separately The composite hot stream


x y x (MW) y (T) Cp
0 40 0 40
31.5 250 6 80 0.15
31.5 80 6 80
61.5 200 54 200 0.4
54 200
61.5 250 0.15

Cold Stream Plotted Separetely The composite cold stream


x y x (MW) y (T) Cp
0 20 0 20
32 180 24 140 0.2
32 140 24 140
59 230 44 180 0.5
44 180
59 230 0.3

COMPOSITE COLD STREAM ( SUHU DI COLD STREAM DIPINDAHKAN HINGGA ΔT= 10 C)


CO
x (MW) y (T) Cp
300
10 20
34 140 0.2 250
34 140
200
54 180 0.5
T (C)

150

100

50
250

200

54 180

T (C)
150
69 230 0.3
100

50

0
0 10 20

HOT STREAM COLD S


Number of
stream
1
2
3
4

150 40
0.15

182 150 120 C 80


4 0.25
1 5 CP
140 20
0.2
57.5
140 140
0.3
Hot stream
300

250
dotted line
x y 200
31.5 0 T (C)
150
31.5 250
61.5 0 100
61.5 200
50

0
0 10 20 30 40 50 60 70
ΔH (kW)

Cold Stream
dotted line 250
x y
32 0 200
32 180
59 0 150
T (C)

59 230
100

50

0
0 10 20 30 40 50 60 70
ΔH (kW)

COMPOSITE STREAM
SEHINGGA DIDAPATKAN
300
Qc min 10
250 Qh min 7.5
Q rec 51.5
200
T (C)

150

100

50
250

200
T (C)
150

100

50

0
0 10 20 30 40 50 60 70 80

HOT STREAM COLD STREAM


ΔH (kW)
50 60 70

50 60 70

A DIDAPATKAN
kW
kW
kW
Supply Target ΔH Heat Capacity
Stream Type
Temperature Temperature (MW) Flowrate Cp h
Reactor 1 Feed cold 20 180 32 0.2 0.0006
Reactor 1 Product hot 250 40 -31.5 0.15 0.001
Reactor 2 Feed cold 140 230 27 0.3 0.0008
Reactor 2 Product hot 200 80 -30 0.25 0.0008
steam hot 240 239 7.5 7.5 0.003
cooling water cold 20 30 10 1 0.001

Hot Stream Plotted Separately The composite hot stream


x y x (MW) y (T) Cp
0 40 0 40
31.5 250 6 80 0.15
31.5 80 6 80
61.5 200 54 200 0.4
61.5 239 54 200
69 240 346.5 239 7.5
239
240
240
250

You might also like