DEVCHAND ENGINEERS PVT.

LTD
Works: A-4/5, Sachin Udyog Nagar Sahakari Mandli Ltd., opp: Village - Vanz Dandi Road, Sachin, Dist: Surat 394230
EQUIPMENT DESCRIPTION: VACUUM BUFFER TANK
EQUIPMENT TAG NO: V-2105 Job No : DEPL-U-001
DRAWING REFERENCE: DEPL-U-021-001_R0 Page 10
Document No : DEPL-U-DSG-001
RADIOGRAPHY REQUIREMENTS - as per UW-11 Revision No : 0
Code Clauses Description Applicability RT

UW-11(a)(1) Is Vessel or Vessel sections is used to store Lethal substances No NONE

Are the butt welds in vessels in which the nominal thickness exceeds 38
UW-11(a)(2) No NONE
mm. UCS-57
Is butt welds in the shell and heads of unfired steam boilers having design
UW-11(a)(3) No NONE
pressures exceeding 50 psi (350 kPa)

Are butt welds in nozzles, communicating chambers, etc., attached to


UW-11(a)(4) vessel sections or heads that are required to be fully radiographed under No RT1
(1) or (3) above.

Are category A and B butt welds in vessel sections and heads where the
UW-11(a)(5) design of the joint or part is based on a joint efficiency permitted by UW- Yes RT1
12(a) and are of type (1) or (2) as per table UW - 12

Are Category B and C butt welds [ Excluding those or nozzles that neither
exceeds 250 NB nor 29 mm thickness ] which intersect the Category A
UW-11(a)(5)(b) butt welds in vessel sections or heads or connect seamless vessel No NONE
sections or heads shall, as a minimum, meet the requirements for spot
radiography in accordance with UW-52.

All butt welds joined by electro gas welding with any single pass greater
UW-11(a)(6) No NONE
than 1 1/2 in, (38 mm) and all butt welds joined by electro slag welding

all Category A welds in a tubesheet shall be of


UW-11(a)(7) Not Applicable -
Type (1) of Table UW-12;

Ultrasonic examination in accordance with UW-53 may be substituted for


radiography for the final closure seam of a pressure vessel if construction
UW-11(a)(8) of vessel does not permit interpretable radiographs in accordance with No -
code requirements. The absence of suitable radiographic equipment shall
not be justification for such substitution.

Conclusion:
AS ABOVE CONDITIONS IS APPLICABLE, FULL RT IS NOT REQUIRED FOR WHOLE VESSEL
ALSO FULL RT IS PROVIDED AS PER CUSTOMER'S REQUIREMENT.
RADIOGRAPHY FOR EQUIPMENT = FULL (UW-11(a) AND UW-51)
MARKING ON NAME PLATE = RT1 (AS PER UG-116)

Adopted Radiography