Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

37

Owner :- Mrs.Sita Yakha (Biratnagar-03,Morang)

Beam Details:-

24.CONCLUSION

1.0 IS code 456-2000: Plain and Reinforced Concrete code of Practice


2.0 IS code 1893 (part I)-2002: Criteria for earthquake Resistant Design of Structures
3.0 IS code 875-1987: Code Of Practice For Design Loads
Part 1 Dead Loads
Part 2 Imposed Loads
Part 5 Special loads and Load combination
4.0 IS code 13920-1993: Ductile Detailing of RCC structures subjected to seismic force- Code of practice
5.0 Nepal National Building Code (NBC 105): Seismic Design of Buildings in Nepal
6.0 RCC structures by A.K. Jain
7.0 RCC structures by S.N. Sinha
8.0 Limit State Design by Vargees
9.0 Structural Design of Multistoried building by U.H. Varyani
10.0 IS code SP 16 Design guidelines for RCC Structures
11.0 IS code SP 34 for detailing of RCC structures

Recommendation
Design and Construction of the structure are inter-related jobs. A performance of a building depends upon a work and
material quality during the construction more than the intensions pursued during the structural design. A large percentage
of structural failures are attributed due to poor quality of construction. Therefore, to assure the proper safety,
material and work quality should be maintained during the construction. However, Designer will not be responsible
for any faulty constructions at site.

1. It is recommended to strictly follow the section size and reinforcement provided in the structural drawings.
2. It is recommended the site engineer should be responsible to handle the problems that may arise during the
construction. She/he shall be responsible for maintaining the material and process quality during the construction.
3. It is strictly recommended to maintain the standard in the grade of cement and reinforcement steel. It is recommended to
run a cube test to ensure the strength and quality of the concrete ratio used. It is also recommended to run a re-
bending test of the reinforcement steels to ensure the quality of steel used.
4. It is recommended to carry out the soil test to check the bearing capacity before construction so as to ensure the
2
assumed value of 120 KN/M is within safe limit.

[STRUCTURAL ANALYSIS REPORT OF COMMERCIAL BUILDING]