Professional Documents
Culture Documents
Structural Steel Design Details
Structural Steel Design Details
1
Job No. 108 QRF NO 108
Designed By SPR Checked By SPR
Rev No 0 Date 02/12/2021
Project M/S CCE R&D
INDEX
S.No Description
1 Design Codes
2 Material Specifications
3 Design Assumptions
4 Loads
5 Serviceability Criteria
6 Primary Loads
7 Load Combinations
2
Job No. 108 QRF NO 108
Designed By SPR Checked By SPR
Rev No 0 Date 02/12/2021
Project M/S CCE R&D
1) Design Codes:
d) Indian Standard Code of Practice for Design Loads Part-2 (IS: 875-1987)
(Reaffrimed 1997)
e) Indian Standard Code of Practice for Design Loads (IS: 875 -2015)
3
Job No. 108 QRF NO 108
Designed By SPR Checked By SPR
Rev No 0 Date 02/12/2021
Project M/S CCE R&D
1. Material Specifications
The following is the list of the material standards and specifications for which the
building components have been designed:
635 Mpa
ASTM A325 Type1 12mm-24mm dia
8. High Strength Bolts
Electro Galvanized 560 Mpa
25mm-38mm dia
4
Job No. 108 QRF NO 108
Designed By SPR Checked By SPR
Rev No 0 Date 02/12/2021
Project M/S CCE R&D
3. Design Assumptions
The mainframe rafters and exterior columns are rigidly connected to each other
(using moment type connections)
The lateral stability of the building is provided through the frame action of the main
frames.
The longitudinal stability of the building is provided through the truss action in the
cross braced bays of the building.
The roof purlins are continuous beams supported at frame locations and span the
bay spacing of the building.
The sidewall girts are continuous tube supported at rigid frame locations and span
the bay spacing of the building.
The roof and wall sheeting provide lateral support for Purlins and Girts.
5
Job No. 108 QRF NO 108
Designed By SPR Checked By SPR
Rev No 0 Date 02/12/2021
Project M/S CCE R&D
4. LOADS
Dead Load as per IS 875-PART-1-(2015)
Dead Load
Dead load has been considered, as 0.12 kn/m2 due to weight of sheeting and Purlins.
Live Load as per IS 875-PART-2-(2015)
Live load
Live load on roof has been considered as 0.75 kn/m2.
Collateral load
N/A.
6
Job No. 108 QRF NO 108
Designed By SPR Checked By SPR
Rev No 0 Date 02/12/2021
Project M/S CCE R&D
DESIGN
1.5DL+1.5LL
1.5DL+1.5(WL/EL)
0.9 DL+1.5(WL/EL)
1.2DL+1.2LL+1.2WL/EL
DEFLECTION
* DL+LL
* DL+WL/EL
* DL+LL+WL
* DL+LL+EL
* DL+0.8(LL+WL)
* DL+0.8(LL+EL)