Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

OTDR REPORT

OTDR v2.01 © Grandway 2021-09-27 17:09:48


Job
Job ID: TMCA/211776 File: G005_1_3_11 - C28.sor
Contractor: EXACT ENGINEERING SDN BHD Date: 2021-09-21 04:11:49
Customer: PARCEL 3 BBCC Operator:
Configuration
Wavelength(nm): 1310 Range(m): 5000 Backscatter coeff(dB): -79.000
Pulse(ns): 20 Average: 0 Loss threshold(dB): 0.000
Origin End Reflection threshold(dB): -0.000
Location: SP02 C28 Location: BIN C999 - G005/1/3/11 End of fiber threshold(dB): 0.000
Cable: 12 Cable: 24 Index: 1.465
Fiber: 04 Fiber: 02
Color: MERAH Color: KUNING
Comment
Trace

dB

52.5 B A

45.0

37.5

30.0

22.5

15.0

7.5
0.000dB
0.882dB
0.011km
0.013km

0.908dB
1.393km

0.0
0.000dB
2.476km
0.413dB/km

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 km
0.882dB/km

A: 2.500km B: 1.665km A-B: 0.835km


0.00dB 4.77dB 4.77dB
5.713dB/km
Event
Event Order Distance(km) Segment(km) Loss(dB) Total Loss(dB) Slope(dB/km) Reflection(dB)
1 Reflect(S) 0.000 0.000 -- -- -- --
2 Reflect(F) 0.013 0.013 0.882 0.025 -- -14.088
3 NoReflect(F) 1.393 1.379 0.908 8.974 0.413 --
4 Reflect(E) 2.476 1.084 -- 10.470 -- -27.985