Power SCADA
MV Equipment/relays LV Equipment/breakers Power & energy metering & Branch Circuit Meters PQ meters
other Modbus devices
Power SCADA + Advanced Reporting Architecture
Optional Software Modules:
Technical details
• Breaker Performance Module
• Energy Billing Module
• Energy Analysis Module
• Generator Performance Module
• EPSS Module
• Power Efficiency Module
• Power Capacity Module
• Power Quality Advisor Module
• IT Billing Module
PowerSCADA Anywhere
• UPS Performance Module
HTML5 Application Single Power SCADA HMI
Advanced Reporting &
Historical Data Dashboards Server
Native Hot-standby
Redundancy (optional)
Modbus TCP, ION, IEC61850, DNP3, SNMP Onboard logs and alarms, waveforms
MV Equipment/relays LV Equipment/breakers Power & energy metering & Branch Circuit Meters PQ meters
other Modbus devices
Energy Usage options for Power SCADA
Reporting options based on the depth of functionality
Q: What is the shortest time Power SCADA could interrogate devices to obtain alarm, real time, and
trend data?
A: Device data acquisition can occur within seconds - it is only limited by the latency of the communications
network and the responsiveness of the devices.
Power SCADA Operation for real-time situational awareness
Power Monitoring & Alarming
The power of a SCADA uniquely
• High performant real-time communications
designed for
• Native system redundancy and scalable architecture
Power Management Applications
• Extensive protocol support & open data exchange
• Highly customizable with scripting and an open API
• Cyber resilient networks and servers
Source Control
• Monitor complex auto-transfer schemes
• Remotely and safely control breakers
Power SCADA
Client No single point of failure
Communicating
device
Scale your system as your needs evolve
Small systems require minimal hardware
It can be installed and run on an embedded PC like the Schneider Electric Magelis pictured above or even a
tablet such as a Microsoft Surface.
61850 Ed.2 and OPC UA
Open Standard Protocols and Data Exchange available August 2018
Large variety of protocols allows for vendor agnostic equipment communication
IEC61850 Edition 2
DNP3
OPC support
> OPC UA client
> OPC DA v2 client & server
> OPC AE v1 server
SNMPv2 Database connectivity
> ODBC, OLE-DB, SQL
Other Schneider Electric software
> Web Services to integrate alarms with
EcoStruxure Building Operation
Take your power system anywhere in the facility
Power SCADA HMI available on any HTML5 web browser or smart device
PowerSCADA Anywhere
Manually Control Loads
Open/close breakers remotely
Alarm capabilities
• Filter, sort and categorize alarms based
on time, severity, equipment, state,
priority, etc. in the software HMI
Re-establish normal
operations quickly and safely
once root cause is determined
Sequence of Events Functionality
Fully-featured waveform viewer to analyze electrical events