Load Bearing Wall On Slab: Detail 03
Load Bearing Wall On Slab: Detail 03
Load Bearing Wall On Slab: Detail 03
[150]
6"
[3600]
2. THIS AND ALL OTHER STRUCTURAL DRAWINGS MUST NOT BE SCALED ONLY WRITTEN DIMENSIONS ARE TO BE
12'-0"
3. ALL CONCRETE UNLESS OTHERWISE STATED TO BE 1:2:4 MIX ATTAINING A MINIMUM CUBE CRUSHING
STRENGTH OF 3,000 PSI. (20 MPa) AT 28 DAYS.
4. ALL BARS TO BE DEFORMED DIA. GRADE 40 AND TO HAVE A MINIMUM GURANTEED YIELD STRESS OF 40,000
3"(75mm) Ø pvc
PSI. (275 MPa) AND GRADE 60 TO HAVE A MINIMUM GURANTEED YIELD STRESS OF 60,000 PSI. (414 MPa). Reinforced beam see structural
drawings for reinforcement
rainwater downpipe
10 (3/8") Ø links
5. ALL LAPS ON BARS TO BE A MINIMUM OF 42 TIMES DIAMETER.
5 # 13 (1/2") Ø M.S.B. @ 225 c/c
6. COVERS TO MAIN BARS SHALL BE AS FOLLOWS UNLESS OTHERWISE STATED:
in 1:2:4 concrete mix
I. FOOTING 50mm (2") MINIMUM
II. BASES 50mm (2") MINIMUM
III. COLUMNS 38mm (1 ½ ") MINIMUM DETAIL 03 LOAD BEARING WALL ON SLAB
IV. BEAMS 25mm (1") MINIMUM Scale 1: 10mm (1" = 1'-0")
V. SLABS 19mm (3/4") MINIMUM 6"
VI. STIFFENERS 25mm (1") MINIMUM [152]
[1500]
5'-0"
VII. BELT BEAMS 25mm (1") MINIMUM
VIII. LINTEL BEAMS 25mm (1") MINIMUM 200 (10")Ø CONC. COLUMN
7. ALL EXCAVATIONS SHOULD BE APPROVED BY THE ENGINEERS/ARCHITECT BEFORE PLACING STEEL. 1'-0" REINF'D WITH 2113(
")Ø M.S
[300] BARS & 6(1
")Ø LINKS @
8. ALL REINFORCEMENT SHOULD BE APPROVED BY THE ENGINEERS/ARCHITECT BEFORE PLACING OF ANY 4
250(10")o/c.
CONCRETE.
[150]
6"
[1125]
3'-9"
9. ALL BLOCK WALL SHOULD BE REINFORCED WITH 12mm (1/2") DIA.BARS AT 400mm (16") CENTRES VERTICALLY
AND 10mm (3/8") DIA. BARS AT 600mm (2'-0") CENTRES HORIZONTALLY UNLESS OTHERWISE STATED.
10. ALL LINTELS SHOULD BE REINFORCED WITH 4# - 12mm (1/2") DIA. BARS IN 10mm (3/8") DIA. STIRRUPS AT 225mm
10 (3/8") Ø links
200
(9") CENTRES FOR A SPAN UP TO 2100mm (7'-0") UNLESS OTHERWISE STATED.
4 # 13 (1/2") Ø M.S.B. @ 225 c/c
11. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY
HARD CORE
COMPLETED. IT IS SOLELY THE GENERAL CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION in 1:2:4 concrete mix
FLOOR SLAB
GRADE
600
PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS
DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING,
GUYS OR TIEDOWNS EHICH MIGHT BE NECESSARY, SUCH MATERIAL SHAL REMAIN THE CONTRACTORS
STANCTION DETAIL END OF SLAB DETAIL
PROPERTY AFTER THE COMPLETION OF THE PROJECT.
12. IT IS SOLELY THE GENERAL CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES
450 x 450 x 600 HIGH
750
AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION.
BASE REINF'D WITH
EARTH
13. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL 4No.43"Ø M.S. BARS &
NOTES, THE SPECIFICATIONS, OR WITH EACH OTHER, THE STRICTEST PROVISION SHALL GOVERN. 6(1/4")Ø LINKS @ 250
14. ALL DIMENSIONS AND ELEVATIONS SHOWN ON STRUCTURAL DRAWINGS SHALL BE VERIFIED BY THE (10") o/c.
300 X 300 Ceramic tile
CONTRACTOR AND SHALL CONFORM TO THOSE SHOWN ON THE ARCHITECTURAL DRAWINGS.
300
250 150 150 250
15. GOVERNING CODE: 1997 STANDARD BUILDING CODE. 150 mm Thk B.R.C. Slab
16. LIVE LOAD 4800 N/M2
17. DEAD LOADS 5200 N/M2 1050 x 1050 x 300 DEEP
300 mm Thk Hard Core 12 mm dia bars @ COLUMN FOOTING
18. WIND LOADS 150 MPH, GUST 200MPH 150 o/c both ways REINF'D WITH 7No.
1050
250
5/8"Ø M.S. BARS BOTH
150 mm Thk reinf'd conc. WAYS.
blockwall reinf'd with 12 mm
dia bars @ 400mm o/c.
300
c c
4# 12 mm dia. bars with
10 mm links @ 250 mm o/c
FOUNDATION NOTES 1050 x 1050 x 300 DEEP
COLUMN FOOTING
250
1. ALL CONCRETE WORK SHALL BE WITNESSED BY GENERAL CONTRACTOR OR ENGINEER/ARCHITECT. REINF'D WITH 7No. 5/8"Ø
M.S. BARS BOTH WAYS.
2. GENERAL CONTRACTOR SHALL ENSURE COMPLIANCE WITH STATE REGULATIONS AND OWNER'S
CONTRACTUAL REQUIREMENTS. STIFFNER TYPE 1 450 x 450 x 600 HIGH BASE
Compact Earth 3
3. EACH PARTY IS RESPONSIBLE FOR CLEAN UP OF THEIR RESPECTIVE CONTRIBUTION TO THE PROJECT. SITE REINF'D WITH 4No. 4"Ø M.S.
BARS & 6(1/4")Ø LINKS @ 250
1050
SHALL BE KEPT FREE OF ACCUMULATED WASTE MATERIALS AND GARBAGE. 3# 12mm dia. bars with
10 mm links @ 300mm O/C. (10") o/c.
4. GENERAL REQUIREMENTS:
Backfilled Area 200 (10")Ø CONC.
A. BY EXECUTING CONTRACT, THE GENERAL CONTRACTOR AFFIRMS HE HAS VISITED THE SITE AND IS COLUMN REINF'D
10 mm links @ 250 mm o/c 1
FAMILIAR WITH CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. SHOULD SOIL CONDITIONS FAIL WITH 13( 2")Ø M.S
1
TO MEET THE ABOVE MINIMUM REQUIREMENTS, GENERAL CONTRATOR SHALL NOTIFY BARS & 6( 4")Ø LINKS
4# 12 mm dia. bars 1050 @ 250(10")o/c.
ENGINEER/ARCHITECT PRIOR TO BEGINNING FOUNDATION AND FOOTING WORK. 250
B. GENERAL CONTRACTOR SHALL REFER TO ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR ANY OTHER
ADDITIONAL SLEEVES, ANCHORS, VENT OPENING, ETC. NOT SHOWN ON STRUCTURAL DRAWINGS THAT
PLAN - COLUMN BASE
MAY BE REQUIRED. 225 12 mm dia bars @
150 o/c both ways
C. ALL SHOP DRAWINGS SHALL BE APPROVED BY A STRUCTURAL ENGINEER.
A. FILL MATERIAL SHALL HAVE A PLASTICITY INDEX BETWEEN 4 AND 12 AND BE COMPACTED IN150mm (6")
LIFTS TO 98 % OF ITS STANDARD PROCTOR DENSITY.
B. BOTH SIDES OF FOUNDATION WALLS SHALL BE BACK FILLED SIMULTANEOUSLY SO AS TO PREVENT
450
OVERTURNING OR LATERAL MOVEMENT OF WALLS. NO FILL OR BACKFILL SHALL BE SETTLED BY USE OF
900
WATER. 6" 6" 6"
[150] [150]
19'-21 8'-41
4"
[150]
4"
[5757] [2407]
6" 13(1/2")Ø M.S. BARS AS BRACE BAR.
[150]
F. CONCRETE: ASTM SPECIFICATIONS 4'-73
4"
1"
11'-12 4'- 61
4" 2'-21
4"
1"
4'-62 2'-2"
7575
[615]
PORTLAND CEMENT C - 150 [1250] [3464] [1246] [623] [1384]
75
AGGREGATE C - 33 12mm Ø @ 150 o/c 12mm Ø @ 150 o/c 12mm Ø @ 150 o/c CONC. MORTAR BAND AROUND TOP OF COLUMN.
25
12mm Ø @ 150 o/c 12mm Ø @ 150 o/c 12mm Ø @ 150 o/c
I. CONCRETE SHALL HAVE A MINIMUM CRUSHING STRENGTH AT 28 DAYS OF 3, 000 PSI (20 Mpa.) USE OF CALCIUN 6" 200 (8")Ø CONC. COLUMN REINF'D WITH1
2")Ø M.S
13(
[305]
1'-0"
12mm Ø @ 200 o/c 12mm Ø @ 200 o/c 10mm Ø @ 300 o/c 10mm Ø @ 300 o/c 12mm Ø @ 200 o/c
INSTITUTE (ACI) SPECIFICATIONS.
II. VAPOR BARRIERS SHALL BE PROVIDED UNDER ALL CONCRETE PLACED ON GROUND SURFACE. See belt beam 13(1/2")TH. SMOOTH RENDER.
detail #2 See
III. A BULLFLOAT OR DARBY SHALL BE USED IMMEDIATELY AND POURING. BULLFLATING MUST BE
COMPLETED BEFORE ANY BLEEDING OF THE SURFACE 6" beam/slab 6"