CYCLE TIME
No load
Boom Raise 2.8—3.4 Max. 3.9
Fully extend
H.O—H 3.7—4.5 Max. 4.8
Eng. Full Boom
G.O—S 4.0—5.0 —
Arm-In horizontal
position F.O—S 6.9—8.5 —
L.O—L 7.5—9.1 —
Bucket Curl Boom & Arm horizontal Sec. 3.6—4.4 Max. 4.8
L.H.
Swing 5 Turns 22.0—26.0 Max. 30.0
R.H.
PC300,310-5 Eng. Full L.H.
27.2—31.2 27.2—33.2
Travel 5 Turns H.O—H mode R.H.
PC300LC,310LC-5 L.H.
29.7—33.7 29.7—35.7
Travel 5 Turns R.H.
Travel and work mm
Deviation Max. 200 Max. 220
equip. /20m
HYD. DRIFT
Entire work equipment no load Rated load mm
Max. 600 Max. 900
specific position Eng. Stopped /15min
HYD. OIL
Dip the oil thermometer sensor into
Hyd. Oil temp. : 45—55
the middle of the hyd. oil tank.
09-03 1/2
PC220 (LC)-5 AVANCE #35001~ PMEH101800
Pm-CLINIC SERVICE PC220 (LC)-5 AVANCE LIMITED #35662~
STD.: Standard Value
HYD. PRESSURE ( ) : Reference Value PMS.: Permissible Value
ITEM Condition Unit STD. PMS. Result Sat Us
H.O—H (2.45—3.53) (2.45—3.53)
Pc
Control pump Low {(25.0—36.0} {(25.0—36.0}
pressure H.O—H 3.04—3.53 2.45—3.53
Full {31.0—36.0} {25.0—36.0}
All levers in H.O—H 2.26—2.45 Min. 1.77
NEUTRAL Full {23.0—25.0} {Min. 18.0}
H.O—S
— —
Full
H.O—L
— —
Full
TVC valve
Arm DUMPING — —
1.57—1.77 1.47—1.77
Bucket CURL relief
{16.0—18.0} {15.0—18.0}
R.H. travel, track raised from
— —
ground
All levers in Max. 0.54 Max. 0.54
NEUTRAL {Max. 5.5} {Max. 5.5}
Boom RAISE — —
Arm Curl relief Max. 0.54 Max. 0.54
Front pump
SWING LOCK OFF {Max. 5.5} {Max. 5.5}
NC valve
Arm Curl relief
output pressure — —
SWING LOCK ON
Swing relief by bucket
Power Max. OFF — —
CO/NC Valve
NOTE: Write-down any phenomena or information, you found by your five sences during today's inspection.