Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Ref. No. PDP 7.4.

3 cONTENTS
Revision: 2
Date: 05.08.2020
Page No.
Declaration of Language Translation: Declaration Of Language Translation:
SHYCOCAN comes to you as a package, along with Labels, User Manual Warranty 4
and other documents to enable the customer to effectively and safely
use the product. All the above documents provided to the customer are
Intended Use
Operating Precautions
5
printed in English, and can also be supplied in the local language on
request by the EU customers as soon as possible and also all such Cleaning Precautions
translations shall bear the words 'Translation of Original
Instructions' Electrical/ Electronics Precautions
Earthing Requirement
Disposal Prcautions
Symbols Definitions: 1
Device Specification:
Regulatory Compliance 9
Installation Procedure 10
Visuals of Packaging/Wall Mounting & 11
Scalene Europe N.V External Components
Geestbrugweg 46, 2281 Rijswijk
WARRANTY INTENDED USE

is warranted against any The device Scalene Hypercharge Corona Canon (SHYCOCAN) is intended
sCALENE SHYCOCAN, Model SHCC915
defects and workmanship for one year from the to be an /
used in industrial commercial environment and is designedfor
manufacturing active containment by attenuation of Corona family of viruses.
date of purchase.

SHYCOCAN operates on a 110/240V-50/60 Hz to generate extra high


During the warranty period any defective parts will be replaced
free of cost along with service and replacement to the tension at a switching frequency of 20 KHz that delivers the necessary
customer signals to a photon mediated electrons emitters (PMEE), that produces
hypercharge high velocity electrons that interacts with the negative
This warranty is not applicable if, seeking S-protein of corona family of viruses thus reducing infectivity
and
1.Damage to the device is caused due to mishandling or improper use. and prevent
air surface borne transmissionof Corona family of viruses.
The Device utilizes viable biological components in the corona family of
2.The customer fails to maintain the device in a proper manner.
3.The customer uses any parts, acces5ories, or fitting not recommended
by SCALENE.
viruses for its intended
The device does not
purpose (Example: S- protein of the viral Spine).
produce harmful ozone gas.
4.Service carried out by an unauthorized person.

1.0pera Precautions
is not liable incidental or
Scalene
of
far
property damage
consequential damages including
personal injury resulting from breach
It is
imp tto go through warnings and cautions specified here before
loss use,
of warranty
or
using t ice.
The terias Warning" and "Caution" have specifñic meanings in this User
Manual.

Mysore Science and Technology Pvt Ltd


#201 & 202, Shreshta Bhumi, "Warnings" advises against actions or situations that could result in
Basavanagudi, No.87, K.R.Road, personnel injury or death.
SHYCOCAN
NBengaluru-560004, Karnataka (INDIA)
Phone: 080-26603636, 26601309 Fax: 41204731
WARNING

Email: mmci@mmclindia.com
6.Symbols and Definitions:

.A.Cleaning Precautions This symbol


manufacture"
denotes"Name of manufacturer combined with date of

Switch OFF the mains power supply before cleaning and making repairs.
We strongly a qualified technician certified Symbol denotes the details of
recommended that
Cybernetics Limited should perform any servicing.
by Scalene Authorized representative in the European community

The outer part and the cannon of the device should be cleaned by a
CAUTION This Symbol indicates that there is a danger of high Voltage around the
dry cloth. area where the symbol appearss
Voltage
3. Electrical/ Electronies Precautions Numerical digits follow this symbol is the

Do not splash water on or in the vicinity of the machine. It could cause


SN serial number of the device

WAANG
an electrical leak or malfunction. The symbol indicates that the rotating blades could cause severe injury
Do not touch the cannons spot while the device is on. Keep hand safe

Install away from the reach of children and pets.

4.Earthing Requirement
This symbol indicates "Do Not Insert Finger can cause
The place of installation should have proper earthing as per local regulatici Electric Shock.
earthing before installation.
This Symbol indicates that there is a danger of 230 Volts
5.Disposal Precautions A around the area the symbol appears.

Disposal of all components of this equipment should be done in a non-polluting and


environmentally safe manner as recommended for metal and electrical waste w
Country specific disposal norms shall be followed in during disposal of the device. sCALENE HnTCiutEcORONA G
Md
Product Label
AL
SHYCOCAN
7. Device 5pecification:
8. Regulatory Compliance

to all the applicable International Regulatory standards, relating to


Device Name SHYCOCAN The device complies
EMI/EMC and Efficacy.
Technical Name Scalene HyperchargeCorona Canon safety,
Hypercharge High Velocity Eleciron
Opera Innut Voltage 110V and 220 Vstandard Generation
power supply 2014/30/EU -

Electromagnetic Compatibility
Directive
Operu Eiectron Production/Second 10 to 100 trilon per Voltage Directive
Estimateo second 2014/30/EU
-
Low
ron Production/
EstimatedP-Electron Second 10 to 100 trillion per second
Production/>E IEC 60335-1:2010, CORJ :2010, COR2:2011, AMO1:2013, CORJ:2014,
110V and 220 V
Operating nput vold 0.11 to 0.35 Amps
standard power suppiy AMD2:2016, CORJ :2016
Operating Current
Switching Frequency- 15to 20 KHz (Dynamic) IEC 61326-1:2012
Ozone Safety Test Study; Report
No. Shy-OZ-05072020, Test No: SHY-2306-50-1::
PMEE VIKUR- Super Aloy
Cannon Material (Pin) iron inC Ozone levels were below detection levels (BDL) during an 8 hours tested in a closed
Canon Base Non-Conductive PP chamber. Requirement: US EPA, FDA, EUA.
Cannon Shell Laboratories de Especialidades Immunological S.A. de C.V, Report
InsulationResistance 20,000 MQ Virology Study;
Comparatilve Tracking Index 600 volts No: 44527- Viricidal Activity concludes 99.99% virus elimination, dated June 16, 2020.
Dissipation Factor at 50Hz_ O.02
Permittvity _ max Capsid Study (S-Protein); Report for Virucidal activity test on
Influenza B enveloped
ElectricalStrengtn 50KV 25mm RNA virus with spike proteins dated July 27, 2020 concludes that "during the analysis it
Moisture Absorption 0.04% was determined that the device has the Virucidal activity and causes a reduction of
stmated ACcelerauon rate 1.500,000 eV 2521.2 CID 50 of B virus to and
Effective Volume Covered 10,000cubic feet 47287,67313 and influenza corresponding distance
instrument Cooling Air Flow CFM times evaluated (100cr device for 15 minutes, 100 cm from a device for 45
Static Air Pressure O/13 Inch-H20 minutes and 300 cm fr ce minutes). Asa comparison asymptomatic
Ozone Generation during Operation Below Detection Levels (BDL
for 45
seasonal influenza Bpa duces between 12000 and 38 thousand CFID S0 in
RoS, NOx, SOx Below Detection Levels (BDL every 30 minutes. (yan e. J18). This experimental research was obtained with
Reduction of TVOCinconfined space
(from Human Breath)
8.95 mg/m3/min.
equipment activation for 120 at a
minutes room. The interpretation of
6mx3mx2m
the result is that within the exposure times tested the SHYCOCAN device eliminates
Note: Owing to the evolving pandemic scenario and continuous development and regulatory influenza B virus, a virus that has spike proteins as corona virus, in similar magnitudes
speciications are subject to change without notice to the recipient of this document. of the exhaled virus by a symptomatic influenza virus infected patients even
Scrutiny,
Recipients are advised to maintain constant check for upgradation. for 30 minutes".
UNIT SHCC- 915 DATE 0H07
FUNCTIONAL TEST CHECKED BY L

SL.NO. CATEGORY STATUS


Fuse
Buzzer
SCALE
Indicator
Photon
Lux

Unit TesSt
L8BURN IN 15 Min

SHYCOCAN

Mysore Science and Technology Pvt Ltd


201 & 202, Shreshta Bhumi, Basavanagudi, No.87, K.R.Road,
Bengaluru-560004, Karnataka (INDIA)
Phone: 080-26603636, 26601309 Fax: 41204731
Email: mmcl@mmclindia.com

You might also like