Professional Documents
Culture Documents
Enerwa / Enerwaplus: Premix System Condensing - Erp Combi Gas Boilers
Enerwa / Enerwaplus: Premix System Condensing - Erp Combi Gas Boilers
Premix System
Condensing - ErP Combi
Gas Boilers
Enerwa / EnerwaPlus
Condensing-ErP
Premix System Boilers
24/31 - 28/35 - 32/40 kW
Warmhaus wall-hung gas combi boilers Enerwa and EnerwaPlus,
with the advantage of its width as 288 mm, are easily fit to
narrow places to assemble.
EnerwaPlus Control Panel Features
» 3” LCD - Black and Orange display and black digits-symbols
colors control panel with 6 push-buttons: MODE, RESET,
CH and DHW easy digital buttons for the hot water
and heating water temperatures
» Visuals of hot water temperature and
All-in-one smart digital heating temperature on LCD screen
display with push button » Flame modulation indicator
» ±1 °C temperature sensitivity
» Digital manometer showing the pressure
» Auto- diagnosis codes & identification system
General Features » Different working parameters condensing combi gas boilers
» Compatible with ErP directive (2009/125 / CE)
» 108.4% efficiency with stainles steel heat exchanger
» EU environnemental compliance combi
» Three power options: 24/31, 28/35 and 32/40 kW
» High DHW capacity
» 3” LCD display (Enerwa Plus)
» ± 1 degree heat sensitivity
» 10 mm whole body insulation
» Stainless steel DHW heat exchanger
» Gas adaptive system
» High savings with 1:10 modulation on 24/31 kW
» Electronic control power pump (7,5 h/m)
more stronger & quieter circulation
» Both LPG and natural gas compatible
» Low pressure safety
» Automatic trouble shooting system
» Low emission
» Double NTC sensor system
» Weekly adjustable digital room thermostats (optional)
» Outdoor temperature sensor (optional)
EnerwaPlus 24/31
EnerwaPlus 28/35
EnerwaPlus 32/40
2
Condensing-ErP
Premix System Boilers
24/31 - 28/35 - 32/40 kW
General Features
» Compatible with ErP directive (2009/125 / CE)
» 108.4% efficiency with stainles steel heat exchanger
» EU environnemental compliance combi
» Three power options: 24/31, 28/35 and 32/40 kW
» High DHW capacity
» 2” LCD display (Enerwa)
» ± 1 degree heat sensitivity
» 10 mm whole body insulation
» Stainless steel DHW heat exchanger
» Gas adaptive system
» High savings with 1:10 modulation on 24/31 kW
» Electronic control power pump (7,5 h/m)
more stronger & quieter circulation
» Both LPG and natural gas compatible
» Low pressure safety
» Automatic trouble shooting system
» Low emission
» Double NTC sensor system
» Weekly adjustable digital room thermostats (optional)
» Outdoor temperature sensor (optional)
Enerwa 24/31
Enerwa 28/35
Enerwa 32/40
3
W
NnEed by com
The Features of
mi pa
er r
et
ing
iations are d
24 k ombi b
Enerwa / EnerwaPlus
Wc
var
kW
al
te
o
ic iler
inu
hn s
lt/m
All tec
DH
W flo 2.8
w rate 1
24 kW
3 kW
ring
ariations a
with
the most efficient
24 kW com
LPG and
NATURAL modulated fan system
kw
al v
GAS
air / gas combination.
nic
h bo
ec ilers
All t
24
LPG or SILENT
NATURAL
GAS ECONOMIC COMPACT SILENCE
Warmhaus boilers DIMENSIONS
can supply you
efficiency with natural Very low electric It fits even in narrow By the 10 mm cover
gas and also LPG. consumption area with its compact isolation, Warmhaus
(maximum: 82 W). dimensions. gas boilers works in
W: 420 mm silence and avoids
H: 725 mm heat loss.
D: 288 mm
6
SMART 3” LCD CONTINUOS
DISPLAY HOT WATER
HIGH DHW WORKS
WIDE INFORMATION ASYMETRIC HEAT
CAPACITY UNDER LOW
DISPLAY EXCHANGER SYSTEM
LCD display shows New generation heat
PRESSURE
High DHW power
the temperature exchanger provides (31 kW) with plenty Works even at very
of DHW, CH and high flow ratio with of hot water. low water pressure
system pressure on its wide asymetric conditions.
the same screen. water-channels by its • ΔT = 30 °C
• 14,8 l/min (only 0,15 bar = 1,5 l/min.)
own design plates.
7
Smart Processor’s
Features of
Enerwa / EnerwaPlus
new design
Priwa 24 PriwaPlus 24
A A++ A
XL
STAINLESS STEEL
A+ A+
B B
A A A A
B C B C
C D C D
CONDENSING HEAT D
E
E D
E
E
F F
EXCHANGER F
G G
F
G G
Single Coil
Ferritic Stainless Steel
(EN 1.4509 /AISI 441) 24 24
kW kW
* No parallel hydraulic circuits. 52 dB 52 dB
* No brazing and manifold in
the hydraulic circuit. 2015 811/2013 2015 811/2013
10
Warmhaus
ErP-Energy-related
Products
INNOVATIVE AND
ENVIRONMENTAL
By the Innovative and environmental
approach, Warmhaus combi boilers Easy to
focus on less energy consumption, by Understand
its latest technology.
ErP Label
Enerwa 24
A++ A A
A+
B
ErP (Energy-related Products) Directive, regulated by the A
B
A
C
European Union after the first successful step ErP in 2009, C D
D
includes all the products consuming energy. E
E
F
F
G G
XL
20% increase saving energy by the consumers, A++ A A
A+
B
A A
C
20% increase on the efficiency of the all energy related products. B
C D
D E
E
F
The new sticker system of the European Union allows the F
G G
consumers to see if the products are manufactured on the basis
of ErP directives.
Regarding to the ErP directives, these stickers has to show the 24
energy consumptions, voice decibel and all the other performan- 52 dB kW
ces of the products by its degrees.
2015 811/2013
11
208
118
Dimensions & Technical 118 208
Specifications
208
118
Connections
WARM
A
B
C
118 208 D
725
725
E
208 F
G
H
118
WARMHAUS PRIWA / ENERWA I
J
A CENTRAL HEATING FLOW K
30 B DOMESTIC HOT WATER OUTLET
288
ACB GAS C INLET
D E
D DOMESTIC
420 HOT WATER INLET
725
725
118
E208 CENTRAL HEATING RETURN
F FILLING VALVE
G MANOMETER
H PRESSURE RELIEF VALVEFOUTLET
I DRAIN POINT G
K WARM
J CONDANSATE DRAIN H
J K 230V 50HZ AC
136
74 A
94
30
40
288 B
A B C D E
420
100
65 148 65 65
I C
D
725
725
E
F
KEY PUMP FLOW G
F H
K G PRESSURE GRAPHIC
A : Central Heating Flow I
H J
B : Domestic Hot Water Outlet
J External control via PWM 1
K
136
C : Gas Inlet 74
94
P/kPa
40
7 70
F : Filling Valve 420
4210/15 PWM1
G : Manometer 6 60
J : Condensate Drain
K 230V 50HZ AC K 3 2750/45 PWM1 G 30
2 2260/55PWM1 H 20
J 1770/65 PWM1
136
1 PWM1 74 10
94
1290/75PWM1
800/85
40
0 0
0 0,40 ,8 1,21 ,6 2,02 ,4
100
65 148 65 65
I
13
TECHNICAL DATA UNIT Warmhaus
Enerwa-ErP 24/31 & Enerwa-ErP 28/35 &
EnerwaPlus-ErP 24/31 EnerwaPlus-ErP 28/35
CE certification CE-1015CR0544 :16 CE
Gas Circuit
Gas type G20 G25 G31 G20
Gas supply pressure mbar 20 37 37 20
Inlet pressure (min÷max) mbar
Gas Consumption at Maximum m³/h 2,35* 2,81 0,90 2,97*
Gas Consumption at Minimum m³/h 0,37* 0,43 0,10 0,39*
*(Natural Gas G20) Heat Load (Hu=10,56 kWh/m3)
Premix System Gas Adaptive Gas Adaptive
Modulation Range 1:10 1:07
Heat Exchanger Material Stainless steel Stainless steel
Efficiency
(80/60 oC) Efficiency at Maximum Heat Output % 98,03 97,84 97,76 97,88
(50/30 oC) Efficiency at Maximum Heat Output % 105.11 105,34 103,63 105.0
Efficiency at 30% load at 36/30 °C % 108,29 108,38 108,29 107,54
Radiator Circuit
Maximum heat input Qn kW 24,25 24,25 24,25 28,70
Minimum heat input Qn kW 3,5 3,5 2,8 3,75
Maximum Heat Output Pn (80/60 °C) kW 23,7 23,7 23,7 28
Minimum Heat Output Pn (80/60 °C) kW 3 3 2,5 3,5
Maximum Heat Output Pn (50/30 °C) kW 25 25 25 30
Minimum Heat Output Pn (50/30 °C) kW 3,6 3,6 2,9 3,90
Temperature selection range (min÷max) high temperature ºC 25÷80 25÷80
Temperature selection range (min÷max) low temperature ºC 25÷47 25÷47
Operating Pressure (Maximum) bar 3 3
Operating Pressure (Minimum) bar 0,5 0,5
Expansion tank useful volume bar 8 10
Pump pressure (at 1000 l/h flow rate) H2O 5,5 5,5
Pump pressure (at 500 l/h flow rate) H2O 7,8 7,8
Max. Pump Flow Rate ℓ/h 2400 2400
Domestic Hot Water Circuit
Maximum DHW Heat Input kW 31.15 35
Minimum DHW Heat Output kW 3,3 3,75
Max. Domestic Hot Water flow rate (Δt: 30 °C) ℓ/min. 14,8 16,30
Min. Domestic Hot Water flow rate (for the DHW function activation) ℓ/min. 1,5 1,5
Maximum water pressure bar 10 10
Minimum water pressure bar 0,5 1,1
Temperature adjustment range ºC 35 - 60 35 - 60
Electricity Circuit
Electricity Supply V AC–50 Hz 230 V +%10; -%15 230 V +%10; -%15
Electricity Consumption Watt 82 82
Protection Index IP IPX5D IPX5D
Exhaust Gas Circuit
Flue temperature (Qn) °C
(80/60 °C) Exhaust gas temperature (Min. / Max.) ºC 69,3 /70,5 64,6 / 70,2 59,9 / 69,7 60,8 / 66,1
(50/30 °C) Exhaust gas temperature (Min. / Max.) ºC 48,5 / 50,5 47,7 / 49,4 47,0 / 50,5 44,5 / 44,5
Maximum exhaust gas temperature [Maximum DHW mode] ºC 70 70 70 70
NOx Class 5 5
Weighted value of Nox (GCV) mg/kWh 20 19 31
Flue mass flow rate (60/80°C - Qn) Nominal/Minimum g/s 11,13 /1,6 13,23 / 1,72
Flue mass flow rate (60/80°C - Qn) [Maximum DHW mode] g/s 14,3 15,82
General
Dimensions (H x W X D) mm 725 x 420 x 288 725 x 420 x 288
Hydraulic Group Material Brass Brass
Net Weight kg 31,4 32
Packed Device Weight kg 34,6 35,2
Type C 13, C 33, C53, C83 C 13, C 33, C53, C83
I2H (G20=20 mbar), I3P (G31=37
Category I2H (G20=20 mbar), I3P (G31=37 mbar)
mbar)
14
Optional
Remote Controls
TA1 E20
(Entry model)
RC07
WT-07 Wired
P Modulated 4 button,
small display
(Mid model)
RC08
WT-08 Wired
P Modulated 10 button,
wide display
(Mid model)
P
KIT RFRC03
WT-03 Wireless Modulated 10 button,
wide display
15
24/31 - 28/35 - 32/40 kW
Premix System
Condensing - ErP Combi
Gas Boilers
Enerwa / EnerwaPlus