DESIGN OF SINGLY REINFORCED BEAM

INPUT UNITS INPUT VALUES


Width of beam (b) mm 230
factored moment (Mu) KNM 120
charachteristic strength of concrete (fck) N/mm2 20
charachteristic strength of steel (fy) N/mm2 415
charachteristic strength of strriups (fys) N/mm2 250
area of strriups (ASV) mm2 100.5184
clear cover (Cc) mm 25
young's modulus of steel (Es) N/mm2 200000
diameter of tension bars (diat) mm 16
diameter of stirrups (dias) mm 8
factored load (Vu) KN 150

COMPTETION

Xumax/d 0.4791074912
Qlim 2.7554329165
ptlim 0.9554442403
d bal 435.14278193

SRB

actual Depth of beam dact 456.89992102


D 482
d 457
Q 2.4981643696
pt 0.83796634
Ast 880.78641994
Astlim 1004.2674409

DESIGN FOR SHEAR

Tv 1.4270763962
Tc max 2.8
DEPTH IS SUFFICIENT

β 2.7712403053

2.77124

Tc 0.5836660169

COMPUTE MINIMUM SHEAR REINFORCEMENT

Vuc 61349.135031
Vus 88650.864969
SV1 56.35183406
SV2>0.75d 342.75
sv3>300 300

SPACING OF STIRRUPS 56

area of one bar 201.0368


No. of bars 5

Grade of concrete Tc max


M15 2.5
M20 2.8
M25 3.1
M30 3.5
M35 3.7
M40 & ABOVE M40 4
DESIGN OF DOUBLY REINFORCEMENT BEAM

UNITS INPUT VALUVES


WIDTH OF BEAM (b) mm 300
OVERALL DEPTH (D) mm 450
MOMENT (M) KN 500
CHARACHTERISTIC STRENGTH OF CONCRETE (fck
N/mm^2 20
CHARACHTERISTIC STRENGTH OF STEEL (fy) N/mm^2 415
CLEAR COVER IN TENSION (Cct) mm 35
CLEAR COVER IN COMPRESSION (d') mm 35
DIAMETER OF TENSION BARS (dia t) mm 20
DIAMETER OF COMPRESSION BARS (dia c) mm 20
DIAMETER OF STIRRUPS (dia s) mm 8
AREA OF 1 BAR IN TENSION (ast) mm^2 314.12
AREA OF 1 BAR IN COMPRESSION (asc) mm^2 314.12

COMPUTATION
effective depth (d) 405
factered moment (fm) 750000000
Mlim 135587965.23872
xumax/d 0.4791074911878

DOUBLY REINFORCED BEAM

ratio of ccb/d 0.0864197530864


fsc 355
Plim 0.0101593877649
Ast 1 1234.3656134411
Ast 2 4599.2883725866
Ast 5833.6539860277
Ast min 248.85542168675

Ast provided (Astpro) 5833.6539860277


Asc 4798.2347056241
No. of bars in tension zone 19
No. of bars in compression zone 16

ratio of
ccb/d 0.05 0.1 0.15 0.2
fy 415 355 353 342 329
500 424 412 395 370
DESIGN OF AXIALLY LOADED COLUMN

INPUT DETAILS UNITS VALUES


Axial load (P) KN 100
charectaristic strength of concrete (fck) N/mm^2 20
charectaristic strength of steel (fy) N/mm^2 415
b:d ratio mm
main bar dia (dia d) mm 16
dia of lateral ties (dia s) mm 8
effective length (l) mm 3000
factered load (Pu) KN 150
width (b) 230
overall depth (D) 300
COMPUTATIONS
Assuming 1% of steel
area of 1 bar 201.0368
c/s of column (Ag) 14792.17
width (b) 148.9572
depth (d) 99.30482
area of steel (Ast) 147.9217
min area of steel (Astmin) 118.3374
No. of main bars 4
spacing of lateral ties (least of following values)
s1 99
S2 256
S3 300

spacing of lateral ties 99


lateral spacing of stirrups 507.6687
DESIGN OF ONE WAY SLAB

Input Value units


Length Of Slab along Shorter Span(Lx) 3000 mm
Length Of Slab along Longer Span(Ly) 7500 mm
Live Load(LL) 3 Kn/m
Floor Finish load 1.2 Kn/m
Char strength of Concrete(Fck) 25 N/mm²
Char strength of Steel(Fy) 415 N/mm²
Diameter of main bar(dm) 10 mm
Diameter of Distribution bar(ds) 8 mm
Clear clover(cc) 20 mm
Density of concrete(ρ) 25 Kn/m3
Thickness of wall 300 mm
Width of Slab(b) 1000 mm

Calculations

Ratio Ly/lx 2.5

One way slab

overall Depth (D) 150 mm

Effective depth (d) 125 mm

length Calculations

C/c Distance(l1) 3300 mm


l2 3125 mm
Leff 3125 mm

LOAD CALCULATIONS
Dead Load 3.75 Kn/m²
Total Load 7.95 Kn/m²
Factored load 11.925 Kn-m
Factored moment 14.556885 Kn-m

Check for effective Depth

dreq 64.956808 mm
Design is safe

Design of main Reinforcement


a 5.99343
b -45131.25
c 14556885
Ast1 7192.4312 mm²
Ast2 337.68929 mm²
Astreq 337.68929 mm²

Area of One Bar 78.55 mm²

Minnimum Ast 180 mm²

Ast provided 337.68929 mm²

spacing 234 mm

Providing 10mm dia bar @234c/c

Calculation of distribution Steel


Area of 1 bar 50.272 mm²

spacing 280 mm
DESIGN OF TWO-WAY SLAB
DATA
length of span along shorter span lx 3000 mm
length of span along longer span ly 4500 mm
live load WL 3 KN/m^2
Floor finish load Wf 1.2 KN/m^2
Characteristic Strength of concrete fck 25 N/mm^2
Characteristic Strength of steel fy 415 N/mm^2
Assumed dia of bars in shorter span dmx 10 mm
Assumed dia of bars in longer span dmy 10 mm
clear cover Cc 20 mm
density of concrete Dc 25 KN/m^3
thickness of wall Wt 230 mm
width of slab b 1000 mm
Effective depth along shorter span ds dx 125 mm
computations
Ratio of Ly/Lx= 1.5
DESIGN TWO WAY SLAB
Overall depth D= 150 mm
Effective depth along longer span dy= 115 mm
Effective span
along shorter span Lx
Lx1 3230 mm
lx2 3125 mm
Lx provided 3125 mm
along longer span Ly
Ly1 4730 mm
Ly2 4615 mm
Ly provided 4615 mm
load calculation
Dead load (DL) 3.75 KN
Total load (W) 7.95 KN
factored load (Wu) 11.925 KN
moment calculation
αx 0.104
αy 0.046
Mux 11161800 KNm
Muy 4936950 KNm

Effective depth required (dreq) 57.93904 mm


DESIGN IS SAFE
main reinforcement along shorter span
a 5.99343
b -45131.25
c 11161800
Ast1 256.02343
Ast2 7274.0971
Area of steel req (Ast req) 256.02343
spacing of bars 306
provide 10mm dia bars at 306mm c/c along shorter span
main reinforcement along longer span
a 5.99343
b -41520.75
c 4936950
Ast1 121.0172
Ast2 6806.6936
Area of steel req (Ast req) 121.0172
spacing of bars 648

provide 10mm dia bars at 648mm c/c along longer span

table 27 for αx,αy


ly/lx αx αy
1 0.062 0.62
1.1 0.074 0.061
1.2 0.084 0.059
1.3 0.093 0.055
1.4 0.099 0.051
1.5 0.104 0.046
1.75 0.113 0.037
2 0.118 0.029
2.5 0.122 0.02
3 0.124 0.014