Professional Documents
Culture Documents
TVU Server Windows To Linux Upgrade, Dual R Rev A en 04-2020
TVU Server Windows To Linux Upgrade, Dual R Rev A en 04-2020
TVU Servers
Windows® to Linux®
Contact us
Related literature and media Supporting documentation demonstrating TVU transmitters’
The following list contains related literature and media. Refer to compliance with the applicable FCC regulations is available
the latest updated documentation: upon request. Contact TVU Networks at +1.650.440.4812 for
assistance and questions regarding approved modem cards for
Product data sheets
use with TVU transmitters.
• Refer to the latest appropriate TVU Appliance data sheet
Hardware Set up and Operating manuals Safety notices and statements
• TVU Servers Windows to Linux Software Upgrade Proce- The safety notices and statements that may appear in this docu-
dure, Models VS3100, VS3200, VS3250, VS3500, and VS3550 ment are as follows:
(This manual, part number: TVU Server Windows to Linux
Upgrade, Dual R Rev A EN 04-2020) Note: These notices provide important tips, guidance, or advice.
• TVU Hardware Setup User Guide, Models VS3100, VS3200, IMPORTANT: These notices provide information or advice that
VS3250, VS3500, and VS3550 - Linux might help you avoid inconvenient or problem situations.
Software Set up and User manuals ATTENTION: These notices indicate potential damage to pro-
grams, devices, or data. An attention notice is placed just before
• TVU Software User Guide, Models VS3100, VS3200, VS3250, the instruction or situation in which damage could occur.
VS3500, and VS3550 - Linux
CAUTION: These statements indicate situations that can be
Media potentially hazardous to you. A caution statement is placed just
before the description of a potentially hazardous procedure
Not applicable
step or situation.
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Networks® Corporation, © Copyright 2020 Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020
iv | TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020 TVU Networks® Corporation, © Copyright 2020
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers | 1
Introduction
This TVU server upgrade procedure provides the information TVU Model Serial number Software Upgradable
required for upgrading your TVU server software from the prefix version
Windows platform to a Linux platform on TVU server models 3500 AA or AC TVU6 Yes
VS3100, VS3200, VS3250, VS3500, and VS3550.
3550 AA or AC TVU6 Yes
Upgrading your TVU server to the TVU7 platform is recom-
3200 VH, VI, VJ, and C5 TVU6 Yes
mended to allow access for the next generation of high ef-
ficiency video encoding (HEVC) features. As TVU servers evolve 3250 VH, VI, VJ, and C5 TVU6 Yes
with technology and move away from the limitations of legacy 3200 VH, VI, VJ, and C5 TVU4 No
operating systems, TVU Networks continues to move forward 3250 VH, VI, VJ, and C5 TVU4 No
into the H.265 evolution while continuing to provide support to
customers that continue to use legacy VS3100 servers. 3100 AB TVU6 Yes
To use this upgrade procedure be sure you have the following:
Contents • The TVU VS3100, VS32xx, or VS35xx server running Win-
dows version 6.x
This document contains step-by-step procedures to complete
the following upgrade objectives in sequential order: • 1x USB flash drive with at least 5 GB of capacity
• Hardware and storage prerequisites • Rufus utility download from http://rufus.ie
• Procedure overview • HDMI monitor and cable
• Obtain the Windows static IP address • USB keyboard and mouse
• Download the TVU Windows to Linux configuration backup This upgrade only applies to the following TVU server models:
tool and image
• Create a bootable USB disk
• Run the configuration backup tool
• Reimage the server
TVU 5th generation server (model VS3500 and VS3550)
• Restore the static IP address setting
• Restore the server settings
• Problem determination and troubleshooting
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Networks® Corporation, © Copyright 2020 Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020
2 | TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020 TVU Networks® Corporation, © Copyright 2020
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers | 3
Overview
The process for replacing the operating system on the TVU • Write a file to the local USB drive confirming that the
Server is a multistep process that must be completed by an device has been backed up. As a safety measure to prevent
operator with direct physical access to the server. The process is configuration loss, the reimage is designed to fail if it does
explained in detail later in this documentation, but the follow- not detect this file.
ing summary is to provide a high level context to the sequential
Step 3: Reimaging the TVU Server
steps of the process.
Rebooting the TVU Server, intercepting the boot process with
the F12 key, and launching the Clonezilla application from the
IMPORTANT NOTES:
USB thumb drive. This process will:
1. This version of the tool supports dual output servers ONLY.
• Check to see if a backup of the machine has been com-
Multi-output servers are upgraded with the revision 2.0
pleted.
tool.
• Launch Clonezilla and overwrite the local drive with the
2. The transition from the Microsoft Windows operating
new operating system
system to the Linux OS is destructive to all existing local
configuration information, as well as the TVU PIDs which • Prompt for a reboot.
affects all TVUPack parings and grid connections. The
Step 4: Restoring the server settings
backup utility will ensure continuity of the settings and
PID information to ensure a seamless transition between In this step we are rebooting into the Linux environment and
the two environments. configuring the original IP address. Once network connectivity
has been restored, the backup file can be restored to the local
device. Note the following:
Step1: Preparation
• Upon the reboot the user will be presented with a configu-
A USB thumb drive of at least 5 GB capacity needs to be sourced
ration screen asking for the IP address information of the
and prepared for the upgrade process.
device.
The large (approximately 4.2 GB) TVU 7.3 Linux image should be
• The restore backup menu option can now be used.
downloaded.
• A reboot of services, or the whole device will complete the
The Rufus utility should be downloaded to your PC and run to
process.
prepare the drive for later steps.
Step 2: Capture of the current configuration
The process of replacing the entire operating system is destruc-
tive to all data on the device, including the devices unique PID. In
order to bridge the gap between the Windows OS configuration
and the Linux OS configuration, the TVU supplied configuration
backup tool must be used.
The tool is run in the windows environment prior to the upgrade
taking place. Its purpose is to:
• Check that the TVU server is compatible with the OS
upgrade process.
• Capture the current PIDs and configuration settings of the
TVU devices and push them to a cloud based storage for
future retrieval.
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Networks® Corporation, © Copyright 2020 Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020
4 | TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
Obtain the Windows static IP address 1. Go to http://rufus.ie and download the Rufus utility to your pc.
Obtain and document the static IP address of your Windows 2. Launch the Rufus utility. The Rufus Drive Properties screen
server. After the upgrade completes, you will need to re-enter displays.
the static IP information into the TVU Linux server settings win-
dow.
To locate the IP address complete the following steps:
3. Power On the TVU Windows server, press the power button
located in the right lower section of the front panel.
4. Minimize or close your TVU Server software, and press the
Windows button in the bottom left corner of your display.
Then, type CMD in the search field and press Enter. The
command prompt window opens.
Command prompt
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020 TVU Networks® Corporation, © Copyright 2020
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers | 5
11. When the utility completes the process the Status pane
displays a green bar indicating “Ready” as shown below.
12. Click Close. Then, open and verify that your USB drive con-
tains the TVU_Linux_Upgrade_7.3_V1.iso image.
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Networks® Corporation, © Copyright 2020 Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020
6 | TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
Note: You should see two PIDs (instead of one) on the tool.
Troubleshooting notes:
Boot menu
Error message: Platform not recognized
4. The Clonezilla screen displays within a few moments. Press
Ensure that you have a valid network connection. If a network is Enter which should select the top/default choice similar to
not detected, the following message displays: the screenshot below.
Step 3 - Reimage the server 5. When prompted to continue the backup, type Y at the com-
To reimage the server complete the following steps: mand prompt and press Enter. You will be asked twice.
1. When the server reboots, the Gigabyte screen displays.
1. Click the gear icon in the lower right panel of the TVU Server
setting window and select the Restore page.
Restore the static IP address, Subnet Mask, and Restore page selection
Gateway settings 2. The PID and port mapping window displays. Click Restore
To restore your static IP address, Subnet Mask, and Gateway set- for both receivers to complete the process. This process will
tings complete the following steps: take 2-3 minutes.
Conclusion
This completes the restore process. Your TVU Server should be
restored with all of its original configuration settings.
TVU Server network settings screen
Operational control of the TVU server should be through the
Web GUI, or by using TVU Command Center. Please refer to the
Step 4 - Restore the server settings TVU Linux Software Guide for further information.
Q and A
Question Answer
Which server serial numbers are applicable for the upgrade Refer to the compatibility table in ‘Hardware and storage
from Windows to Linux? prerequisites’ on page 1 in this procedure for applicable serial
numbers.
Can I use the tool to upgrade my server running TVU4 from Only servers running version TVU6.x or above, or systems
Windows to Linux? covered by active support contracts will allow the utilities to
run. Contact TVU Networks for more information.
Can I use my USB 2.0 port for uploads and downloads? Yes, however the image is slightly over 4 GB in size, using USB
3.0 devices and ports will speed up the process.
How much USB capacity is required for the Windows to Linux A minimum of 5 GB USB capacity is required to perform the
tool download? upgrade.
Does TVU Networks provide a USB flash drive to the customer No, the flash drive is customer supplied. TVU provides the FTP
to perform the upgrade? link for the tool download.
Can TVU Networks perform the upgrade from Windows to No, this is a customer upgrade procedure. It must be
Linux? performed by someone with physical access to the equipment.
TVU Servers Windows to Linux Software Upgrade Procedure for Dual Receivers
TVU Networks® Corporation, © Copyright 2020 Document part number: TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020
Document Part Number: Printed in USA.
TVU Server Windows to Linux Upgrade, Dual R Rev A EN 04-2020 © Copyright 2020 TVU Networks Corporation
All rights reserved in all media.
Contact information
TVU networks Corporation TVU networks Corporation
857 Maude Avenue, 11030 Raven Ridge Road, Suite 117
Mountain View, CA 94043 Raleigh, NC 27614
Ph: +1 (650) 969-6732 Support Ph: +1 (650) 440-4812
Fax: +1 (650) 969-6747 Support E-mail: support@tvunetworks.com
E-mail: support@tvunetworks.com www.tvunetworks.com
www.tvunetworks.com