aweaqa ReRwaT Faculty of Engineering & Technology JADAVPUR UNIVERSITY DEPT. OF CONSTRUCTION ENGINEERING BLOCK-LB, PLOT-8, SECTOR, SALT LAKE KOLKATA-700 108, INDIA MOBILE ; +91 9493112189 / +91 9675326964, FAX : (033) 2335-7254 Laboratory Test Report Dated: 24.04.2021 1. Test done for 2. Reference No 3. Name of the work ‘ubir Engineering Works (P) Ltd. ” EWPL/ICSECoE/AAKRITH/JU/210325 , dated on 25.03.2021 nnstruction of Centre of excellence of the Institute of Company Secretaries India (ICSI at Plot No. HA/35, New Town, Kolkata - 700156. 4, Name of Client __: Institute of,Company Secretaries India ( ICSI) 5. Type of Test :28 days Compressive Strength of Mix Design of M25 Grade Concrete Cube. Results of Final Trail Mi Trail No. ‘Average 7 days cube ‘Average 28 days cube | Slump(mm) __| compressive strength(MPa) | compressive strength(MPa) T(W/C=0.45) gu 02650 as EEE [ TEU 24221 110 MI(W/C=0.49) 21.98 12, 125 TICW/C=0.40) | 22.87 34.86 105 ‘The slump shall be measured and the water content shall be adjusted for achieving the required slump based on the trail, if required. The mix proportions shall be reworked for the actual water cement and checked for durability requirements. Remarks: Based on the 7 Days & 28 Days results of the above trials, Trial - lis recommended for the M-25 Grade Concrete Ss Dr. Parthia Professdr Mob. No.9433112189 Dr, Partha Ghosh (ME, (Stuetural Ena}, Ph ent