EARTHING PRODUCTS:

Techno Chemical Earthing System-Strip in Pipe:

in this technology, one strip and one pipe are used. the strip ( main conductor ) is placed centrically inside the outerpipe
and space inside the electrode is tightly filled with a cenductive compound mixture (ECC) and then sealed. The crystalline
mixture contains nartural elements and compounds, which are high conductive as anti corrosive
Techno Power
Technical Specifications:
S. No. MODEL NO. Outer Pipe
Domestic, Body earthing,
1. TPB 502 50 x 2000 Electronics devises
Body earthing for drive, PLC &
2. TPB 503 50 X 3000 Automation equipment
Body & Neutral earthing for
3. TPB 802 80 X 2000 industrial equipment
Transformer, Generator,
4 TPB 803 80 X 3000 Lightning anester etc.

Above mentioned electrode comes in 3 different MOC - GI Pure Copper &


Copper Bonded. Sizes can be customized as per customer’s requirement

Techno Chemical Earthing System-Rod Type:


In this technology, one solid rod of required length and dia i ined as electrode. The area
around the electrode should be filled with Techno Ground Enhancement Material.

Techno Back Fill Compound (ECC):


Techno Power is a world leader in the design, manufacture and supply of earthing and lightning protection system.
Techno Back Fill Compound is specially developed compound capable of absorting and retain the maistute Combining over 10'Years technical expertise with an enviable reputation for innovation,quality and service Techno power is
for a tonger period. It has all the qualities of an ideal Back Fii Compound for an efecte a Carthing System. It uniquely placed to provide a “ Total Solution “ to all your earthing,lightning and transient overvoltage protection needs.
consistently holds its own shape and adheres to any sortace it touches It hautelowing characteristics
# Mainly consist of Aluminium Siticate Natural minerals Total Solution
# Helps in current dissipation
# Least fluctuation of Ohmic values
# Retains moisture for a longer period
# It can absorb moisture up to 13 times its dry volume
# Presence of water is not necessary to maintain its resistivity
# Does not dissolve, decompose or teach out with time PRODUCTS RANGE
# Available in packing of 25 Kgs

Techno Power Plot no 163A1/A3 2nd phase GIDC,


• Lightning Protection System
Techno Ground Enhancement Material (ECC): Vapi Dist Valsad - 396195 Gujarat India • Techno Erthing Electrode
Techno Ground Enhancement Material is a superior conductive material that improves earthing esandy • Techno Bonded rod
soils etc.). It improves conductivity of the earth electrode and ground contact area. It has following
characteristics:” Mainly consist of Graphite and Portland cement • Conventional Lightning arrester
# Highly conductive
# Non-corrosive in nature having low water solubility
• Solar Street Light
Authorised Dealer Techno Power
# Resistivity of less than 0.2 ohms-meter:
# Suitable for installation in dry form or in a slurry form
• Earthing Pit Covers
# Not depend on the continuous presence of water
# Does not dissolve, decompose or leach out with time

4 1
According to NF C 17-102:2011, the standard protec on radius (Rp) is Link to ΔT, the protec on levels I, II, III or IV, ( as
“ Techno Earthing System” - TECHNOLOY:
calculated in EN 62305-2) and the height (h) of Lightning rod above the structure or feature to be protected (defined by NF C
17-102 as a minium 2 m). Techno Powers specializes in “Techno Chemical Earthing System” or “Maintenance Free Earthing System”.Earthing is
Technical Features essential and important for the safety of human lives and equipments. Hence, after consistent research and development
Ÿ Designed and tested according to NFC 17-102/2011 we have developed an efficient and effective earthing technology.
Where h≥5 m, then Rp can be calculated from
Standards
Rp (h) = 2rh - h² + Δ(2r+Δ) Techno Earthing System makes sure safety equipments from voltage surge and transients by arresting damages to highly
Ÿ 100% effec veness in discharge
Where 2 m ≤ h ≤ 5m, then Rp can be calculated from sensitive equipment which can be caused by inadequate grounding performance. Techno Earthing Electrodes are highly
Ÿ 100kA Lightning current durability
secured, stable and reliable in all adverse environmental conditions. It is 100% maintenance free and have a long life
Rp = h x Rp (5) / 5 Ÿ Cer fied under Middle East Technical University, Turkey and expectancy. The existing traditional type of Earthing system needs to be changed every 3 - 4 years and uses salt, coal, etc.
Rp (h) (m) is the protec on radius at a given height h CPRI, Central Power Research Ins tute of the Govt. of India which gets washed away over a period of time but Techno Chemical Earthig
h (m) is the height of the ESEAT p over the horizontal Ÿ ISO 9001-140010 cer fied Chemical Earthing System is completely maintenance free and has a life of more than 20 years.
plane through the furthest point of the object to be Ÿ No use of ba ery or external power source
protected Ÿ 304 L Stainless steel (Inox) design suitable for any Techno Earthing Electrode is an ultra efficient low surge impedance grounding system. It provides the desired low
r (m) 20 m for protec on level I environment condi on maintenance interface with the real earth by continuously conditioning the surrounding soil. It is a corrosion free grounding
Ÿ All models including own mast brackets for grounding system ideal for all types of soil conditions. with strong teams’ support, Techno Chemical Earthing System has been
30 m for protec on level II
Ÿ Suitable for use with a variety of down conductor systems, applied in over 200 projects worldwide.
45 m for protec on level III
60 m for protec on level IV i n c l u d i n g ta p e , C a b l e S m o o t h - we ave , I s o l ate d
Techno Chemical Earthing System meets international standards of Bs - 7430, IEEE - 80, IEEE - 142, UL - 467, IS - 3043
Δ (m) Δ = ΔT x 106 Downconductors (ISODC)
maintenance interface with the real earth by continuously conditioning the surrounding soil. It is a corrosion free grounding
Field experience has proved that Δ is equal to the Ÿ 20 years warranty
system ideal for all types of soil conditions. with strong teams’ support, Techno Chemical Earthing System has been
efficiency obtained during the ESEAT evalua on tests Ÿ Testable by external Topbas® Test Devices applied in over 200 projects worldwide.

Techno Chemical Earthing System meets international standards of BS - 7430,IEEE - 80, UL - 467, IS - 3043
P ro te ctio n P ro te ctio n L e ve l I P ro te ctio n L e ve l II P ro te ctio n L e ve l III P ro te ctio n L e ve l IV
L e ve l (9 9 % , D = 2 0 m ) (9 7 % , D = 3 0 m ) (9 1 % , D = 4 5 m ) (8 4 % , D = 6 0 m )

Ionia® ESE Lightning Rod Model Ionia


15
Ionia
40
Ionia
60
Ionia
15
Ionia Ionia Ionia Ionia
40 60 15 40
Ionia
60
Ionia
15
Ionia
40
Ionia
60
IMPORTANCE & ADVANTAGES:
ΔT (µs) 15 40 60 15 40 60 15 40 60 15 40 60
h(m) Rp ( m) Protec on Radius
Technical Specifica on 2 15 23 32 16 26 34 19 30 40 22 34 44
As heart is for body, importance of Earthing is for electrical circuit. Earthing is critical area of electrical engineering
Ÿ Electronical Structure 3 20 35 48 23 39 52 28 40 59 31 50 65 maintenance.
Ÿ NFC 17-102/2011 Early Streamer 4 26 46 64 30 52 68 36 60 78 41 67 87 An efsystem also helps in mitigating the electrical disturbances and serve as a common voltage reference to the
5 32 58 79 37 65 86 44 75 97 51 83 107 sensitive electronic equipment.
Ÿ Suitable for corrosive environment 6 32 59 79 38 66 86 45 46 97 52 84 107
Ÿ 304 L Stainless Steel (Inox) Material 7 33 59 79 39 66 87 46 76 98 53 85 108
8 33 59 79 40 67 87 47 77 99 54 86 108 Manufactured from custom made Gl/Copper pipes to ensure maximum conductivity and longer service life.
Ÿ No use of external ba ery
Electrode contains a conductor rich crystalline mixture to protect the main earth electrode in the soil and facilitates the
Ÿ Lenght: 59CM / Net Weight: 301 kg faster transfer of the fault current to the earth.
Ÿ Ion Unit Diameter: 125mm
Ÿ Rod Diameter: 20Ø Protection from Lightning, Short circuit. Leakage of current. Electrical shock, Current fluctuation, fault current, High
Ÿ Grounding mastdiameter:2” voltage etc.
Ÿ Testable with external Topbas® Test Device
Ÿ 20 Years Warranty LIGHTNING Benefits of greater personal and equipment safety, reliability, current load capacity, discharge path for short circuits,
Ÿ CE Certification, ISO 9001&14001 fault current/surge protection, stable earth value with longer life.
STRIKE COUNTER
Ÿ Maintains uniform earth resistance
CORE FEATURES OF TECHNO
Ÿ Multi directional dissipation of current
EARTHING SYSTEMS:
FEATURES Model StrikerX
Ÿ No need to dispense water recurrently
Descrip on Lightning Striker Counter
Ÿ IP 65 rated enclosure suitable for external
Display Model Electromechanical display (non re se able) Ÿ Prevents static & stray current accidents
application
Ÿ Ease of installation, StrikeX can be retrofitted to Current sensi vity (8/20 µs) >250A Ÿ Ultra Low resistance grounding electrode
any Lightning Current (10/350 µs) 100 KA
Terminal Connec on FRP Pit Cover Low earth resistance & High Conductivity
Lightning protection system. Current Sample Mode Induc ve Probe (Built-in) Ÿ
Ÿ Non-intrusive and fast acting proximity circuit
detects Indicator 6 digits Ÿ Authorize any systems fault to ground quickly
Lightning transient currents. Opera ng temprature (°C) -20 ~+85 Charge Dissipa on Bored/Augured Pit
Ÿ Non re sett able electro-mechanical counter. Enclosure material Plas c Ÿ Corrosion resistance material
Ÿ Can be mounted at any location along the down Degree of protec on IP 65 (IEC 529)
conductor. Ÿ Weather proof & Highly durable
Back Fill Compound Primary Conduc ve Electrode
Dimension of counter (cm) 16 (L) x 9 (W) x 6 (H)
Mixed With Soil Ÿ Absorb and retains the moisture
StrikerX lightning Strike counter is designed to count and record the lightning strikes captured by lightning prot Ection C.C.M. Secondary Protec ve Electrode
Ÿ Chemicals used are eco-friendly
systems such as ESE lightning rods, simple capturing rods and the cage method. The lightning counter is necessary to
determine. Ÿ Needs lesser space for installation
whether the lightning rod received any lightning strikes The counteris connected to the down conductor of the lightning Techno Earthing
arrester and therefore it detects the electro magne tic field caused by lightning discharge current, and it counts each Electrode Ÿ Large surface are for current dissipation
strike and shows it by way of the number display.
Ÿ Protection against static electricity from friction
With the help of the lightning counter the customer can follow the number of lightning strikes arrested by your system.
It does not require any additional power supply for its operation