Headline SL 120 Slit Lamp: Subline As Diverse As Your Patients
Headline SL 120 Slit Lamp: Subline As Diverse As Your Patients
Headline
Subline
As diverse as your patients
Corneal
structures in
direct focal
illumination 2)
The all-rounder
with outstanding performance Dermoid
in diffuse
illumination 1)
2 33
Precision Performance
Proven optics from Carl Zeiss generate a crisp, The ultimate in flexibility The slit lamp is one of the most commonly used
razor-sharp image. Excellent resolution and high Thanks to excellent optical transmission, the patient’s examination instruments in practice. This is why
contrast ensure that even the finest structures are eye can be examined with lower light intensity. optimum ease of use and maximum convenience
visible. You benefit from exceptional image detail, A stereo microscope with 5 magnifications steps, a were given top priority in the development of the
therefore increasing the reliability of diagnosis. large field of view and super high-eyepoint eyepieces SL 120.
for eyeglass wearers image the patient’s eye with
A slit image made to measure outstanding ZEISS quality. The SL 120 can be option- Everything under control with just one hand
You can rotate the slit image to adjust it to the ally equipped with a tiltable prism head, reducing The slit lamp can be operated intuitively and exactly
position of the object of interest in the eye. The reflections during examinations with contact lenses. with the joystick and quick-action brake. Thanks to
decentration of the slit image allows a wide variety This allows better observation of the peripheral areas easy-grip controls, the length, width and rotation of
of illumination methods, permitting not only more of the posterior segment. the slit image can be set precisely with a single hand,
exact examination of low-contrast findings such as giving you more certainty and reliability in difficult
corneal scars but also better after-cataract diagnosis. cases. A short working distance ensures a comfortable
The width and length of the slit image can also be arm and body posture.
continuously adapted to the size of the suspected
anomaly.
4 55
Productivity Patient Care
Not only do you benefit from an ergonomically correct Patient satisfaction is your primary goal at all times. A picture says more than a thousand words
design which reduces examination times. The slit lamp Your patients put their trust in the reliability of your Communication creates understanding. You can
is also designed so that its scope of application can diagnosis. The SL 120 is one of the most powerful quickly upgrade the SL 120 into a slit lamp for digital
be easily expanded, permitting, for example, measure- slit lamps. Its excellent performance ensures that documentation, allowing you to explain your findings
ments on the eye using the appropriate accessories. even the finest structures can be visualized, creating clearly and understandably to your patients using
the best possible conditions for reliable diagnosis photographs.
Measurement of intraocular pressure and treatment.
The applanation tonometer allows precise measure-
ment of intraocular pressure. Depending on your Considerably less exposure to light
preference, you can attach an upright tonometer to The high light transmission of the SL 120 reduces light
the swivel joint or mount a suspended tonometer on loss. This means you need less light for exact diagnosis –
the stereomicroscope. Upright AT 030 applanation tonometer and therefore greater comfort for your patient.
VISULINK
A coagulation laser can be attached via the
VISULINK 532/U. VISULINK PDT/U also provides you
with the ideal equipment for photodynamic therapy
of age-related macular degeneration.
6 77
Technical Data
Subject to change in design and scope of delivery and as a result of ongoing technical development. Printed on elemental chlorine-free bleached paper. P U B L I C I S VIII/2008.
Field of 40 … 6 mm with 10x eyepieces
view diameter 31 … 5 mm with 12.5x eyepieces
The contents of the brochure may differ from the current status of approval of the product in your country. Please contact our regional representative for more information.
Eyepiece optionally 10x or 12.5x super high-eyepoint
magnification eyepieces, compensation of ametropia ±8 D
Width of slit image continuous from 0 to 14 mm
Length of in steps 0.3 / 3.5 / 8 / 14 mm;
slit image continuous 1 … 6 mm
Rotation of continuous ±90°
slit image
Decentration of ±4° horizontally,
slit image click stops at -10°, 0°, +10°
Swivel range of 180°, scale for angular difference;
slit projector click stop at 0°
Angle of incidence 0° or 0° … 20° tiltable with tiltable prism head
Filters blue, green (red-free); heat-reflecting filter,
permanently integrated; diffusing screen,
swing-in
Free working 65 mm
distance exit prism/ 2.5 in
patient’s eye
Travel of 30 mm (vertical), 110 mm (lateral), 90 mm (axial)
instrument base 1.2 in (vertical), 4.3 in (lateral), 3.5 in (axial)