The IMM motor protection family
THE STRENGTHS
IMM 7960 and IMM 7990 soragiiveikcye s
cc sy to une ap switch settings
‘cat atten + Modbusifbus communications
oo esa + Wide range of field applications
io : :
7 ee ee Compact size (IMMT960)
Phu wig png . :
Exon fat 2
af ead Bee ee
Thana nage owas pres
ate nee Mes ON ge
= ee ze ee eee te
ZS == a ag ae ee ee eS a
a5.
. ee
2 _ __—————™ : 2THE STRENGTHS
_ + Advanced protection and motor function management
“+ Withdrawable modular electronic unit
+ Simple, powerful interactive setting (front plate or local PC)
+ Automatic setting using PROSETTING software
* Modbus!}bus RS485 or current loop communications
“Wide auxiliary power supply operating ranges
+ Immune to harmonics
* Thermal image memory
* Single unit caters for 1 and 5 Amp
* Multifunction relay (protection, instrumentation, metering)
* Built in dual setting groups
+ Programmable output relays
+ Time stamped event log
+ Temperature measurement by RTDs (IMMB002)
IMM 8001 and IMM 8002
Thermal nage ond
Teal mage ve pen
Seat audorsion
fee stig me
loc att wp
lec rr af startig
Shut eat
Phas rhein pang
Evga fuk
las of ad
Under age
Cher wage
eased aes, cen, vag pow,
sees poe ace
eng
fret hag,
ID ove eget (OH@002)
‘Thera ova concn by RD (HHO)High tara watstond
caret inputs (1/58)
\
7 Operational LEDs
Sating modo
indcing LED
Software and bordnare
sel supevision LED
Connection ro PC based
PROSETTING = —
setng sof
Operational improvements
> Straight forward ordering due to:
- | and SA inputs on the same device
- wide auxiliary voltage operating ranges
= small number of options and variants.
> Early delivery of basic cases enables switchboard
panels to be wired and tested without
unnecessary delays
‘Simplified functional
and connection
diagram ;
-- IMMSOL
ose designed to wit
Digital multifunction « 8000 » series
Besic case includes meesurernent
ts ond Vis.
(ick deliver or so pre ing
_ Widble
elecroic noe
26 ches LED
diglay
4 postion keys
— 4 operational keys
——~ Degree of protection
iPsl
severe eecromagne conditions
D> Commissioning assisted by:
- simple automatic setting (PROSETTING)
= multitanguage man machine interface
> Efficient running thanks to the amount of motor
‘operational data provided
> Enhanced maintenance thanks to periodic
self testIMM 7000/8000 motor protection guide
ANSL___IMM7960_IMM.7990_ IMM 8001__IMM 8002
PROTECTIONS
“Thermal alam °
Thermal overlead (age) .
“Thermal image corrected by RTD °
i %
*
fir starting
rae unbalonengl phasing
Sect ores
Exrgroune fut
feet
5 7
= a7P
CONTROL
Sor auhoreavon
“ecg (ona tess
~ ecg marber of srs ae
Soe eee
Tp eeu supervision
Propane gr
Programmable opus :
INSTRUMENTATION
Temperstire
Line velage (UI3)
Line and eartlground current
Freswancy
METERING
Number of rps
fur ne
Star contol
Hpi sakes
COMMUNICATION
Bier dapty =e
2al6 character display
S485 port (communication bus)
S232 port (front pane!) :
Lol PC PROSETTING sofeware
ENVIRONMENT
Temperate 10°C v9 285°C (EC 68-2)
Inslacion tes wolage IEC 255-5
lectromignetie compari: surcopi
Hig frequen erfrenee (EC 255.2
Fost worst IEC 255.224
ecaldachare Test EN 50082
Feced rad frequency EN 50082
once rec fequeney EN 50082
Rac magne eld EN 50082
Electomagncie compa: emission
Becromognetc ld EN S50)
CEappronl x x x
ex
x
x
x
TECHNICAL BROCHURE 1794 794 ies 19IMM8000 relays
are an integral part
of the modular
PROCOM system.
They can be used
separately or in
an integrated system
via a PROSATIN
electrical network
SCADA system.
Time stamped events,
disturbance records,
settings, instrumentation
and metering are available
upstream on RS485
two wire
or 20mA current
loop networks,
using JBUS/MODBUS
RTU or FIP protocol
via ICF interfaces.
PROSATIN integrated Protection
and Control System
(PS2000 - PS4000)
CEE Relays |.
87C Whitby Road, Slough, Berks, SL1 3DR (Registered Office)
Telephone: (01753) 576477 Fax: (01753) 825661
Website: www.ceerelays.co. uk