Arriving at an accurate measure of blood loss is a challenge many practitioners encounter a�er skin surgery. To date, there has not been a clinically practical way to gauge this figure. Weighing sponges, gauze pads,
measuring drainage containers, or mere guesstimation are the most common methods utilized. Unfortunately, the former methods are a nuisance, and the latter is typically unreliable [1, 2]. This is true even for
major surgical procedures when blood loss may posse a threat to survival [3]. This simple study quantifies the absorption capacity of gauze pads, a material widely used in dermatologic surgery. Awareness of this
value allows for a more rapid and better estimation of blood loss.

Technique

The absorption capacity for 2x2 inches and 4x4 inches gauze pads were explored as these are the most commonly utilized materials during surgery. The 2x2 sponges used in this study
were manufactured by Kendall Curity, 12 Ply, USP Type VII. The 4x4 sponges were manufactured by McKesson, 4 Ply non-woven sponges. The same technique was applied to both
sizes. Sterile containers, each holding one gauze pad, were filled with sequentially increasing amounts of saline ranging from 1-5 mL, in 0.5 mL increments for the 2 x 2 gauze pads,
and 6-13 mL, in 1 mL increments for the 4x4 gauzes. Saturation was defined as the point at which no dry gauze was visible or felt. The end point was achieved when excess fluid
remained unabsorbed at the bottom of the container, a sign of super-saturation (Fig. 1). The 2x2 gauze appeared completely moist from 2-4.5 mL with supersaturation noted at 5 mL
(maximum absorption capacity of 4.5 cc), while the 4x4 gauze pads appeared completely moist from 8-12 mL with supersaturation at 13 mL (maximum absorption at 12 mL). The
average carrying capacity was defined as the average between the initial saturation point and the maximum saturation point.
Figure 1
From this experiment it can be concluded that a completely soaked 2x2 gauze has an average carrying capacity of 3.25 cc ± 1.25 cc and that a 4x4 sponge has an average carrying
capacity of 10 cc ± 2 cc. The limitations of this experiment include intraobserver subjectivity, limitation of results to only the tested brands of gauze, and the fact that normal saline Figure 1: The 2x2 gauze
was substituted in place of blood. Blood has a greater viscosity than saline and has clotting factors, which may allow for a greater gauze absorption capacity. Nevertheless, knowing pads completely absorbed
the number of gauze pads used in surgery and awareness of the individual sponge absorption capacity provides a clinically practical and rapid method to estimate blood loss. a maximum of 4.5 mL of
normal saline. At 5.0 mL,
References super-saturation was
observed. Excess normal
1. Kolb KS, Day T, McCall WG. Accuracy of blood loss termination by health care professionals. Clin Forum Nurse Anesth. 1999;10:170-173.
saline at the bottom of the
sterile container stained
2. Razvi K, Chua S, Arulkumaran S, Ratnam SS. A comparison between visual estimation and laboratory determination of blood loss during the third stage of labor. Aust NZ Obstet
purple for visibility.
Gynecol.

3. Larsson C, Saltvedt S, Wiklund , Pahlen S, Andolf E. Estimation of blood loss a�er cesarean section and vaginal delivery has low validity with a tendency to exaggeration. Acta Obstetricia et Gynecologica.
2006;85;1448-14452.

© 2007 Dermatology Online Journal

Jump To

Article
Main Content

Metrics

Author & Article Info

Related Items

Calciphylaxis: how specific are the pathological features: avoiding false-positives and false-negatives
Mahmood, Muhammad N
Pediatric teledermatology: a tool for combating dermatology care disparities
Ahuja, Geeta; Khushbakht, Myra; Joe, Jenita; Eskinder, Henok; Ekwunazu, Chiamaka;  ...
The Impact of teledermatology during the COVID-19 pandemic
Shah, Pooja; Dorrell, Deborah N; Feldman, Steven R; Huang, William W
How to improve the interface between dermatology and psychiatry: a review and expert suggestion regarding the management of delusional patients

1 of 2 1/7/2022, 11:46 PM
A Clinically practical way to estimate surgical blood loss https://escholarship.org/uc/item/79b1c0sh

Starzyk, Tory; Koo, John


Innovations in translational research in dermatology: minimally invasive methods for biosample acquisition
Hadeler, Edward; Mosca, Megan; Hong, Julie; Brownstone, Nicholas; Liao, Wilson;  ...

Top

Home Privacy Statement

About eScholarship Site Policies

Campus Sites Terms of Use

UC Open Access Policy Admin Login

eScholarship Publishing Help

Accessibility

Powered by the
California Digital Library
Copyright © 2017
The Regents of the University of California

2 of 2 1/7/2022, 11:46 PM

You might also like