Sulphur Dew Point in Flue Gas Calculations Cells requiring input
Ref: Industrial Boilers by Ganapathy
(Ref : Solved example 6.18b and 6.25b ) Solved Design Parameter Unit Example Case Fuel Coal Mixed Fuel HHV kcal/kg 6096 3800 Btu/lb 11000 6857 S in fuel S % 1.5 0.22 Mol wt of SO2 lb/Mol 64 64 SO2 e lb/MM Btu 2.73 0.64 Mol of SO2 Moles/MM BTU 0.043 0.010 Excess Air % 25 250 Fuel required lb/MM Btu 90.9 145.8 Stoicheometric Dry Air lb/MM Btu 760 Excess Dry Air lb/MM Btu 950 lb/lb coal 10.45 Humidity % 80 Moisture in wet air lb/lb dry air 0.018 Wet Combustion Air required lb/lb coal 10.6381 26.86 lb/MM Btu 967.1 3917.0 Flue Gas Generated lb/MM Btu 1058.0 4062.8 lb/lb coal 11.64 27.86 (Dry Air basis) lb/MM Btu 1040.9 145.8 Mol Wt of Flue Gas lb/Mol 30 29.0 Mol of Flue Gas Moles/MM BTU 34.70 140.10 SO2 in Flue Gas ppm 1228.166 71.6 SO2 to SO3 conversion % 5 1 SO2 e lb/MM Btu 0.136364 0.006 Mol Wt of SO3 lb/Mol 80 80 Mol of SO2 Moles/MM BTU 0.0017 0.0001 SO3 in flue gas ppm 49.1 1
Partial Pressure of H2O atm 0.045384
G S Deshpande: (From combustion analysis) mm Hg 35.3 Partial pressure is same as Partial Pressure of SO3 atm 1.83E-04 volume % (From combustion analysis) mm Hg 0.1424 1000/Tdp 2.30 Tdp Deg K 435.7 Sulphur Dew Point Deg C 163