For the time period of the overspeed test the overspeed limit is set to 85% of the nominal
speed. Thus it is possible to test the shut down valves without danger for the engine.
NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, D - 90429 Nuremberg
Phone: +49 911 32 01-0, Fax: +49 911 32 01-150, info@noris-group.com, www.noris-group.com
Seite 1 / 2
NMS-KD-0034-4-en N3000-SAP Overspeed Test
Version 01.02
Quick User Guide
15.08.2013 - DHI
If the engine is not running within the next 2 minutes after calling up the test mode, the
test mode will be aborted automatically.
If the overspeed test limit is not reached within the next 5 minutes after the engine has
been started, the test mode will be aborted automatically.