DrillPipe, 80%, 5.000 OD, 0.500 Wall, IEU, S-135.. XT50 (6.625 X 3.500)
DrillPipe, 80%, 5.000 OD, 0.500 Wall, IEU, S-135.. XT50 (6.625 X 3.500)
DrillPipe, 80%, 5.000 OD, 0.500 Wall, IEU, S-135.. XT50 (6.625 X 3.500)
SmoothEdge Height Nominal Tool Joint Worn to Bevel Worn to Min TJ OD for
3/32 Raised OD Diameter API Premium Class
Box OD (in) 6.812 6.625 6.318 6.066
Elevator Capacity (lbs) 1,658,000 1,440,200 1,096,600 826,700
Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Assumed Elevator Bore Diameter (in) 5.219 Note: A raised elevator OD increases elevator capacity without affecting make-up torque.
Pipe Body Slip Crushing Capacity Pipe Body Configuration ( 5 (in) OD 0.500 (in) Wall S-135 )
Nominal 80 % Inspection Class API Premium Class
Slip Crushing Capacity (lbs) 667,800 529,900 529,900
Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from “Why Does Drill Pipe
Assumed Slip Length (in) 16.5 Fail in the Slip Area” World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
Transverse Load Factor (K) 4.2 slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.
Pipe Body Performance Pipe Body Configuration ( 5 (in) OD 0.500 (in) Wall S-135 )
Nominal 80 % Inspection Class API Premium Class
Pipe Tensile Strength (lbs) 954,300 746,400 746,400
Pipe Torsional Strength (ft-lbs) 94,100 73,000 73,000
TJ/PipeBody Torsional Ratio 0.96 1.24 1.24
80% Pipe Torsional Strength (ft-lbs) 75,300 58,400 58,400
Burst (psi) 23,625 21,600 21,600 Note: Nominal Burst
calculated at 87.5% RBW
Collapse (psi) 24,300 20,510 20,510 per API.
Pipe OD (in) 5.000 4.800 4.800
Wall Thickness (in) 0.500 0.400 0.400
Nominal Pipe ID (in) 4.000 4.000 4.000
Cross Sectional Area of Pipe Body (in^2) 7.069 5.529 5.529
Cross Sectional Area of OD (in^2) 19.635 18.096 18.096
Cross Sectional Area of ID (in^2) 12.566 12.566 12.566
Section Modulus (in^3) 7.245 5.621 5.621
Polar Section Modulus (in^3) 14.491 11.243 11.243
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box ID’s, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
www.NOV.com/GrantPrideco/CustomerFeedback Customer Created 02-03-2014
Operational Limits of Drill Pipe
Connection XT50 Tool Joint OD (in) 6.625 Tool Joint ID (in) 3.500 Tool Joint Specified Minimum 120,000
Yield Strength (psi)
Pipe Body 80 % Inspection Class Pipe Body OD (in) 5 Wall Thickness (in) 0.500 Pipe Body Grade S-135
Combined Loading for Drill Pipe at Combined Loading for Drill Pipe at
Maximum Make-up Torque = 54,300 (ft-lbs) Minimum Make-up Torque = 45,300 (ft-lbs)
Operational Assembly Pipe Body Connection Max Operationa Assembly Pipe Body Connection
l Torque Max Tension Max Tension
Torque Max Tension Max Tension Tension Max Tension
(ft-lbs) (lbs) (lbs) (lbs) (ft-lbs) (lbs) (lbs) (lbs)
Connection
Make-up Torque Range
Make-up Torque Connection Max
(ft-lbs) Tension (lbs)
Min MUT 45,300 1,247,200
46,300 1,219,600
47,300 1,192,000
48,300 1,164,500
49,300 1,136,900
50,300 1,109,300
51,300 1,081,700
52,300 1,054,100
53,300 1,026,600
Max MUT 54,300 999,000
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box ID’s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014
Connection Wear Table
Connection XT50 Tool Joint OD (in) 6.625 Tool Joint ID (in) 3.500 Tool Joint Specified Minimum 120,000
Yield Strength (psi)
Connection
Wear
Tool Connection Max Connection Max Min MUT Connection Max
Torsional Tension Tension
New OD Joint OD MUT
(in) Strength (ft-lbs) (ft-lbs) (lbs) (ft-lbs) (lbs)
Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body 80 % Inspection Class Pipe Body OD (in) 5 Wall Thickness (in) 0.500 Pipe Body Grade S-135
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box ID’s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.