Download as pdf
Download as pdf
You are on page 1of 4
Horizontal Rectangular Ster 3 g MODI ENTERPRISES (INDIA) Address : 16, Sahyog Industrial Estate, Opp. S.K. Stone Co., Mira Bhayander Road, Mira Road (E), Mumbai 401 107 Tel : 2812 3051 / 2811 1441 / 2855 3051 Email : modisterilizer@rediffmail.com modientp@yahoo.co.in Web : www.modientp.com .--- Rectangular. Introduction ssi ra ‘The ever growing demand for more efficient and advanced hospital, industrial and scientific equipment with higher capacity and better performance, providing safe and effective sterilization, has led the development of 'MODIS’ sterilizers throughout the years. The ‘MODIS company has been designing and manufacturing a wide range of sterilization equipment for more than 30 years. ‘MODIS’ product serve as standard equipment in : + Hospital complete C.S.S.D. + Day care facilities + Laboratories. + Research industries. + Animal care facilities. + Medical Waste Treatment facilities. + Pharmaceuticals & Micro-biological industries + Biotechnology, Tissue Culture + Agriculture University Application ‘The Autoclave operates with saturated steam as the sterilization agent, working at pressure in the range of 22-32 p.s.i. (1.2 = 2.2 kg/cm2) and temperature in the range of 115°C to 135°C. Special temperature setting are available on request. ‘The sterilization method substantially shortens the sterilization cycle, achieved by evacuating the air with powerful ejector / vacuum pump, combined with steam pulsing. A0.2 micron sterile air filter is provided to filter the air, which equalize the vessel pressure after the drying cycle, "MODIS" offers alarge range of Sterilizer models from Standard 50 liter to 2000 liter size, as well as varied chamber dimensions according to the specific use and nature of Product requirements. Standards The sterilizers are manufactured as per .S.I codes and bearing 1.S.1 Mark No. IS; 3829, Part! & II ‘endorsing the highest quality Gravity Sterilizer __- Horizontal Rectangular Autoclave / Sterilizer, Centralised Control point + Mult-port operating value : control forthe entire cycle of the operating, * Permits two exhaust speeds, fast & slow. * Easy to read pressure & temperature, * Smooth operation. Safety Features + Hinge type Single / Double door + Seif locking safety door cannot be opened while chamber is under pressure. + Gauge glass tube with automatic closing safety valve. + Heat resistant silicone door gasket. + Pressure switched (on electric models) economise power consumption. * Low water protection system, to protect the electric heaters, * Temperature gauge / Digital temp. Indicators / controllers (optional) + Vacuum breaker / dryer. + Safety valve for the jacket / boiler * Hydraulically test to 2.5 times the designed working pressure, + Powerful ejector for drying. + Insulated with resin bond fibre glass wool covered with M.S/S.S. sheet. Options «+ Heating : Direct steam, Electic OR LPG operated steam generators. + Front pane model with inbui thermal printer + Fully automatic operation through a MICROSTER PROCESS with manual option + Digital temperature timer / alarm display for semi-automatic operation + Cycle with pre-vacuum & post vacuum through vacuum pump & condenser option. + Dot matrix / Thermal printer /Thermograph to record temperature and time + Double door type models + Stainless Stee! fush mounting on stele side + Carriages, trolleys, baskets ec. for easy movement of goods. Fully Automatic Sterilizer Operation + Direct Steam : 1.2 kg / Cm’ for High Pressure model or 2.1 kg / Cmfor High Speed Model. + Electricity : 3 Phase 440V, 50Hz AC supply Microprocessor / P.L.C. with touch screen H.M.I. based control system The control system is based on ‘state-of the art’ microcomputer technology, guaranteeing high reliability and safe operation. The computerized control unit ensure a fully automatic operation throughout the entire cycle. No future Intervention is necessary after selecting the parameters and pressing the start button. The main cycle phase and the machine's actual parameters are displayed on the LCD panel during the cycle progress. The main physical parameters of the process, i.e. temperature, pressure, time and jacket pressure are controlled and displayed. The keyboard located on the front panel ‘enable the operator to select programs, start and stop the cycle, and allows a trained technician to preset the main parameters using an access code. The control system is easy to use and programmable. enable the operator to select programs, start and stop the cycle, and allows a trained technician to preset the main parameters using an access code, The control systemis easy to use and programmable. Printer (Optional) Fora clear and concise documentation of cycle process the control units provided with a dot matrix printer which is connected to the microprocessor .The printer generates a hard copy printout of the relevant information concerning the cycle operation such as the temperature, pressure, Vacuum, sterilization and drying time, number of cycles/number of pulsing ete. In case of an uncompleted cycle, the printout indicates the cycle failure and the cause of the failure (optional). An additional graphic printer is optional Cycle available (Automisation) Gravity 121°C / Gravity 134°C / HPHV 121°C / HPHV 134°C / Bowie Dick Test / Leak Test The sterilizer is designed to operator up to (6) six standard sterilization programs between 105° C. and 137° C and (2) two test programs optional. All programs are selected by using the numeric keypad, and all programs are programmable, Air removal, sterilization and drying stages can be reprogrammed easily. After sales service “MODIS" after sales service provides service all over India with a team of trained technicians who provided service and spares Table specification for Rectangular sterilizer wedet | wen7 |mense| meres | merao | meras | wens) merse |wen-128 Chamber [Hao | sme won| oma 90155) soraR | Tosa | Bim Tu [soc [oo en | 20.00 [oo0.06 | 220.20 [2000 [200 9) | 120048 (inches) | D | 900 (36) | 1200 (48) | 1200 (48) | 1800 (60) | 1200 (48) | 1500 (60)| 2100 (72) | 2400 (84) oA eee w | 850 300 800 800 1200 1200 1250 1400 Ht [too | 06 | 2000 [aco | ion [200 | 2000 [200 | tao [aco | 00 | 700 | 1400 | 1700 [200 | 00 Utilities Consumption / Requirements Power okw | tekw [| i8kw [s6kw | S6kw | S6kw [ DS. DS, Boller (Li) 85 20 95 100 100 100) 5 5 Elecical 24a | 42a | 42a [73a | 730 73K Requirement Phase 3 3 3 3 3 3 (for Autorisation) Compressed Air Requirements : Pressure 6-8 Bar, 3/8" thread connection. Special Electrical Requirements available according to individual order. The Modis Horizontal sterilizer can be supplied according to any dimension required by the customer. Due to continuous marketing research and development, specifications affecting the appearance, utilities orother cosmetic aspect ofthe autoclave may be subject, aad Cylindrical steam Sterilizer - Vertical Autoclave = Table top flash Sterilizer Ultrasonic cleanser + Dryer - EO Sterilizer+C.S.S.D Furniture

You might also like