Horizontal Rectangular Ster
3
g
MODI
ENTERPRISES (INDIA)
Address : 16, Sahyog Industrial Estate, Opp. S.K. Stone Co.,
Mira Bhayander Road, Mira Road (E), Mumbai 401 107
Tel : 2812 3051 / 2811 1441 / 2855 3051
Email : modisterilizer@rediffmail.com
modientp@yahoo.co.in
Web : www.modientp.com.--- Rectangular.
Introduction ssi ra
‘The ever growing demand for more efficient and advanced
hospital, industrial and scientific equipment with higher capacity and
better performance, providing safe and effective sterilization, has led
the development of 'MODIS’ sterilizers throughout the years.
The ‘MODIS company has been designing and manufacturing
a wide range of sterilization equipment for more than 30 years.
‘MODIS’ product serve as standard equipment in :
+ Hospital complete C.S.S.D.
+ Day care facilities
+ Laboratories.
+ Research industries.
+ Animal care facilities.
+ Medical Waste Treatment facilities.
+ Pharmaceuticals & Micro-biological industries
+ Biotechnology, Tissue Culture
+ Agriculture University
Application
‘The Autoclave operates with saturated steam as
the sterilization agent, working at pressure in the
range of 22-32 p.s.i. (1.2 = 2.2 kg/cm2) and
temperature in the range of 115°C to 135°C. Special
temperature setting are available on request.
‘The sterilization method substantially shortens the
sterilization cycle, achieved by evacuating the air with
powerful ejector / vacuum pump, combined with
steam pulsing. A0.2 micron sterile air filter is provided
to filter the air, which equalize the vessel pressure
after the drying cycle, "MODIS" offers alarge range of
Sterilizer models from Standard 50 liter to 2000 liter
size, as well as varied chamber dimensions
according to the specific use and nature of Product
requirements.
Standards
The sterilizers are manufactured as per .S.I codes
and bearing 1.S.1 Mark No. IS; 3829, Part! & II
‘endorsing the highest quality
Gravity Sterilizer __-Horizontal Rectangular Autoclave / Sterilizer,
Centralised Control point
+ Mult-port operating value : control forthe entire cycle of the operating,
* Permits two exhaust speeds, fast & slow.
* Easy to read pressure & temperature,
* Smooth operation.
Safety Features
+ Hinge type Single / Double door
+ Seif locking safety door cannot be opened while chamber is under pressure.
+ Gauge glass tube with automatic closing safety valve.
+ Heat resistant silicone door gasket.
+ Pressure switched (on electric models) economise power consumption.
* Low water protection system, to protect the electric heaters,
* Temperature gauge / Digital temp. Indicators / controllers (optional)
+ Vacuum breaker / dryer.
+ Safety valve for the jacket / boiler
* Hydraulically test to 2.5 times the designed working pressure,
+ Powerful ejector for drying.
+ Insulated with resin bond fibre glass wool covered with M.S/S.S. sheet.
Options
«+ Heating : Direct steam, Electic OR LPG operated steam generators.
+ Front pane model with inbui thermal printer
+ Fully automatic operation through a MICROSTER PROCESS with manual option
+ Digital temperature timer / alarm display for semi-automatic operation
+ Cycle with pre-vacuum & post vacuum through vacuum pump & condenser option.
+ Dot matrix / Thermal printer /Thermograph to record temperature and time
+ Double door type models
+ Stainless Stee! fush mounting on stele side
+ Carriages, trolleys, baskets ec. for easy movement of goods.
Fully Automatic Sterilizer
Operation
+ Direct Steam : 1.2 kg / Cm’ for High Pressure model or 2.1 kg / Cmfor High Speed Model.
+ Electricity : 3 Phase 440V, 50Hz AC supply
Microprocessor / P.L.C. with touch screen H.M.I. based control system
The control system is based on ‘state-of the art’ microcomputer technology, guaranteeing
high reliability and safe operation. The computerized control unit ensure a fully automatic operation
throughout the entire cycle. No future Intervention is necessary after selecting the parameters and
pressing the start button. The main cycle phase and the machine's actual parameters are displayed on
the LCD panel during the cycle progress. The main physical parameters of the process, i.e. temperature,
pressure, time and jacket pressure are controlled and displayed. The keyboard located on the front panel
‘enable the operator to select programs, start and stop the cycle, and allows a trained technician to preset
the main parameters using an access code. The control system is easy to use and programmable.enable the operator to select programs, start and stop the cycle, and allows a trained technician to preset
the main parameters using an access code, The control systemis easy to use and programmable.
Printer (Optional)
Fora clear and concise documentation of cycle process the control units provided with a dot matrix
printer which is connected to the microprocessor .The printer generates a hard copy printout of the
relevant information concerning the cycle operation such as the temperature, pressure, Vacuum,
sterilization and drying time, number of cycles/number of pulsing ete. In case of an uncompleted cycle,
the printout indicates the cycle failure and the cause of the failure (optional). An additional graphic printer
is optional
Cycle available (Automisation)
Gravity 121°C / Gravity 134°C / HPHV 121°C / HPHV 134°C / Bowie Dick Test / Leak Test
The sterilizer is designed to operator up to (6) six standard sterilization programs between 105° C.
and 137° C and (2) two test programs optional. All programs are selected by using the numeric keypad,
and all programs are programmable, Air removal, sterilization and drying stages can be reprogrammed
easily.
After sales service
“MODIS" after sales service provides service all over India with a team of trained technicians who
provided service and spares
Table specification for Rectangular sterilizer
wedet | wen7 |mense| meres | merao | meras | wens) merse |wen-128
Chamber [Hao | sme won| oma 90155) soraR | Tosa |
Bim Tu [soc [oo en | 20.00 [oo0.06 | 220.20 [2000 [200 9) | 120048
(inches) | D | 900 (36) | 1200 (48) | 1200 (48) | 1800 (60) | 1200 (48) | 1500 (60)| 2100 (72) | 2400 (84)
oA
eee w | 850 300 800 800 1200 1200 1250 1400
Ht [too | 06 | 2000 [aco | ion [200 | 2000 [200
| tao [aco | 00 | 700 | 1400 | 1700 [200 | 00
Utilities Consumption / Requirements
Power okw | tekw [| i8kw [s6kw | S6kw | S6kw [ DS. DS,
Boller (Li) 85 20 95 100 100 100) 5 5
Elecical 24a | 42a | 42a [73a | 730 73K
Requirement
Phase 3 3 3 3 3 3
(for Autorisation) Compressed Air Requirements : Pressure 6-8 Bar, 3/8" thread connection.
Special Electrical Requirements available according to individual order.
The Modis Horizontal sterilizer can be supplied according to any dimension required by the customer.
Due to continuous marketing research and development, specifications affecting the appearance, utilities
orother cosmetic aspect ofthe autoclave may be subject,
aad
Cylindrical steam Sterilizer - Vertical Autoclave
= Table top flash Sterilizer Ultrasonic cleanser
+ Dryer - EO Sterilizer+C.S.S.D Furniture