5/14/13 CORROSION INHIBITING ADMIXTURES

Contribute Your Articles

Building Concrete Construction How To Guide Geotechnical Earthquake Structural Search...

CORROSION INHIBITING ADMIXTURES SUBSCRIBE

Subscribe by E-Mail to receive latest updates.


SIGN UP
Alloy Plate
www.specialtysteelsupply.com
4140 4142 8620 6150 thickness range
1/4"-6" Cut to size

Inhibitor Solution ABOUT THE AUTHOR


www.protektol.com
Inhibitor Solution Patent No. This blog is authored and maintained
109784/67 Cement Slurry Coating
by Gopal Mishra. He is the founder of
The Constructor.
shreeram Rockwool
www.shreeramrockwool.com
Mineralwool matts,RBslab,PIPE,
Acoustic insulation in india WE ARE ON FACEBOOK

Corrosion-inhibiting admixtures are not currently covered by EN 934 but are effective after
POPULAR
the concrete has hardened and give a long-term increase in the passivation state of steel
reinforcement and other embedded steel in concrete structures. The three most common C oncrete Technology How To Guide
generic types of corrosion inhibiting admixture are:
Geotechnical Engineering Structural

Calcium nitrite (normally contains a residual amount of calcium nitrate)


GE Lab Tests Structural Design
Amino alcohols
Amino alcohols blended with inorganic inhibitors Material Testing Guide C onstruction Buildings

Building Materials Soil Foundation


The dosage of corrosion inhibitors is usually dependent
upon the client’s expected serviceable life of the C onstruction Management Structure Design
structure and on a range of factors that affect the
Structural Analysis Water Resources
durability of concrete. These include cement type,
water-to-cement ratio, cover concrete to the steel, Earthquake Engineering
ambient temperature and the expected level of
exposure to chlorides. The typical dosage range for a
30% solution of calcium nitrite is 10–30 litres/m3 but is
more usually used between 10 and 20 litres/m3

The dosage of amino alcohol-based corrosion inhibitors is usually between 3 and 4 volume
per cent by weight of cement. Both types can be used with other admixture types and their
use with a high range water-reducing admixture is usually recommended in order to ensure
the quality and durability of the base concrete.

Use of corrosion inhibitors:


Corrosion inhibitors can significantly reduce maintenance costs of reinforced concrete
structures throughout a typical service life of 40–60 years. Structures especially at risk are
those exposed to a maritime environment or other situations where chloride penetration of
the concrete is likely. Such structures include jetties, wharves, mooring dolphins and sea
walls. Highway structures can be affected by the application of de-icing salts during winter
months, as can multi-storey car parks where salt-laden water drips off cars and evaporates
on the floor slab.

The concrete should be designed with a low diffusion coefficient and sufficient cover to slow
the rate of chloride reaching the steel, the corrosion inhibitor can then extend the time to
onset of corrosion.

theconstructor.org/concrete/corrosion-inhibiting-admixtures/6765/ 1/2
5/14/13 CORROSION INHIBITING ADMIXTURES
Disaster Relief Tents
Te m porary Living She lte rs Military Grade
www.icte nts.com

Search...

« LOAD & RESISTANCE FACTOR BEHAVIOUR OF CONCRETE IN »


DESIGN (LRFD) EXTREME FIRE

ads by Yahoo!

Tags: Concrete Admixture corrosion of reinforcement

Home » How To Guide » Admixtures Guide » CORROSION INHIBITING ADMIXTURES

HOME ABOUT US CONNECT CONTACT US PRIVACY POLICY

Copyright © 2012 The Constructor

theconstructor.org/concrete/corrosion-inhibiting-admixtures/6765/ 2/2