Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

FORM No. 1045-002302 REGISTERD No.

1808-680002
1808-680004
SPECIFICATIONS

C15149P

SPECIFICATION

EUROMAP 63 Host Communication

CONTENTS REVISION
1.Overview (1808-680102) 2018/08/22 Add sentences

2.EUROMAP63 Settings (1808-680203) 2020/01/17 Image replacement and Add sentences


3.Communication Start (1808-680402) 2018/08/22 3.(1)(2)(4) Add sentences
4.Notes of ftp (1808-680702) 2018/08/22 Change page
5.EUROMAP63 Commands (1808-680702) 2018/08/22 Change page
6.Tokens (1808-680802) 2018/08/22 6.(2)Correct Non-support token
7.Command details (1808-681102) 2018/08/22 7.(1)(5) Add sentences (2)(6)(13)(14)Contents change
8.Use example (1808-681502) 2018/08/22 Change page
9.Token table (1808-681702) 2018/08/22 9.(2) change content of Support and Item(4) delete token
10.Error Messages (1808-682502) 2018/08/22 10.(1)(2) Change message (2)Add message
11.Application Examples (1808-682702) 2018/08/22 Change page
12. Ethernet connection (1808-682803) 2020/01/17 Change description
13. Remarks (1808-682804) 2020/06/19 13.(8) Add sentences
14.Connection check (1808-682902) 2020/06/19 NG display details added
(1811-125101) 2020/06/19 Add sentences

APPROVED CHECKED DRAWN

FD(FORM No.)10-585002(REGISTERD No.)10 - xxxxxx


REGISTERD No. 1808-680102

EUROMAP 63 Host Communication


1. Overview
This EUROMAP 63 host communication is a communication control specification on the injection molding
machine(IMM) side based on the "EUROMAP 63 data exchange interface, Version 1.05a" devised by the
Technical Commission of EUROMAP and SPI. (Reference, http://www.euromap.org)
To use this communication specification, you need to prepare EUROMAP 63-compatible host side management
system and LAN equipment. By using such a host side management system available from venders, quality
management and production management can be made.

HOST COMPUTER
SV1 (192.168.x.x)
[xx Control system]
LAN (Ethernet)
\\SV1\Mach01\Session\
Request Response data

Mach0 Mach0 Mach0

Examples of data output by injection molding machine


Monitor data

DATE,TIME,COUNT,ActCntCyc,ActTmpBrlZn[1,1],ActStrCsh[1],ActStrXfr[1],ActStrPlst[1]
20140424,09:14:19,1,8879, 0.0, 2.33, 29.66, 32.00
20140424,09:14:28,2,8880, 0.0, 2.33, 29.67, 32.00
20140424,09:14:36,3,8881, 0.0, 2.32, 29.67, 32.00
20140424,09:14:45,4,8882, 0.0, 2.33, 29.68, 32.00
20140424,09:14:53,5,8883, 0.0, 2.34, 29.67, 32.00
20140424,09:15:02,6,8884, 0.0, 2.33, 29.66, 32.00
20140424,09:15:10,7,8885, 0.0, 2.33, 29.67, 32.00
20140424,09:15:19,8,8886, 0.0, 2.32, 29.67, 32.00
20140424,09:15:27,9,8887, 0.0, 2.33, 29.68, 32.00

Alarm data

20140425,08:40:06,1,1,966,"* Over-pack ( cushion ) * (966)"


20140425,08:40:11,2,0,966,"* Over-pack ( cushion ) * (966)"
20140425,08:40:50,3,1,966,"* Over-pack ( cushion ) * (966)"
20140425,08:40:54,4,0,966,"* Over-pack ( cushion ) * (966)"
20140425,08:41:03,5,1,732,"* Take out time over * (732)"
20140425,08:41:32,6,1,966,"* Over-pack ( cushion ) * (966)"
20140425,08:41:37,7,0,732,"* Take out time over * (732)"

-1-
C15149P
REGISTERD No.
REGISTERD No. 1808-680203
1808-680202
2. EUROMAP 63 Settings
(1) Setting of communication connection

[MENU1] ⇒ [COMMUNICATION PORT] ⇒ [COMMUNICATION]

State indication
[OK] … Connection is normal.
[NG] … Share name or session path is
not recognized. Check the
setting.

Set the host information/IMM information on the screen of the IMM.


To store the host information into the memory of IMM, press “SETTING” button.
・IP Address / HOST NAME / SHARE NAME … Normally only host1 is set.
・USER and PASSWORD … These are needed for connection with the host computer.
・SESSION PATH … This is a folder name needed for EUROMAP 63 communication
・IP Address / HOST NAME (IMM) … Set the IP address on IMM side.

Notes:
・For the setting of EUROMAP 63, you need to turn “EUROMAP 63 communication” to OFF.
・Set the host information to use a host name/a share name for a session path and a path list.
・After changing the IP address of IMM, you need to make a turning off and on of the IMM power.

-2-
C15149P
REGISTERD
REGISTERD No.
No. 1808-680302
1808-680303
(2) Setting of EUROMAP 63

[MENU1] ⇒ [COMMUNICATION PORT] ⇒ [EUROMAP63]

Communication state

[work] … Number of commands in operation


[total] … Total number of commands
[error] … Number of issued errors

・EUROMAP 63 ON/OFF … ON/OFF of this communication specification (with this setting ON, you
cannot change the host information.)
・CONDITION TABLE SUPPORT (REPORT) ON/OFF … Don’t use this function.(Set this function to[OFF])
・SETTING CHANGE ALLOWED ON/OFF … Use or no use setting of SET command
・SETTING FILE MANAGER ON/OFF … Set this function to ON when you control the molding conditions from
the host computer.
・SETTING FILE MANAGER Text ON/OFF … Choose a text file.(※1)
・CHARACTER CODE Choose the character code to be output, EUC/8851(STANDARD) or UTF-8.
・EUROMAP 63 Normally choose “File Sharing”. (Combined use of EUROMAP 63 with ftp cannot be made.) (※1)
※1…Refer to “7. Command details (13) UPLOAD / DOWNLOAD Command” for detail.

-3-
C15149P
REGISTERD No. 1808-680402
3. Communication Start
(1) Preparation
1) Establish a LAN connection (Local Area Network) that is needed for communication.
2) Prepare information, such as the IP address, host name, share name, and session path,
that is needed for communication between the host computer and the IMM.
3) Set the prepared information on the screen of the IMM.
4) Turn EUROMAP 63 to ON, so that communication can be started
Note;
If the power of the IMM is turned off, “JOB response completion notice”
cannot be written in the JOB response file.

(2) Process of control system on host computer side


1) Communication starts by storing a session requesting file into the session path.
2) You need to use SESS0000.REQ ~ SESS9999.REQ for file names.
3) A multiple number of session requesting files can be stored at the same time.
4) When you use a different control system together with EUROMAP 63,
allocate the different session files:
for example, SESS0001.REQ~19 for System A, and SESS0020.REQ~29 for System B.
5) You can recognize the start of communication by the session response files (SESS0001.RSP~).
6) Store JOB files beforehand that will be demanded by the session requesting file.
7) Program execution state is stored in the JOB response file (or LOG file) appointed
by the JOB file.
8) The data from the IMM is written in the host computer according to the command and
DATA file name directed by the JOB file.

-4-
C15149P
REGISTERD No. 1808-680502

(3) File specification parameters


1) The file-specified character strings of the session path, JOB file, JOB response file,
and DATA file need to contain appropriate information to specify the location of
the network file.
2) The character string has 255 or less characters in quotation marks (" "),
and expressed with absolute path or relative path.

Example of Session Path (absolute path):


\\SV1\INTERFACE\MACH01 SV1…host name, INTERFACE…share name
\\sv1\vol1\machh03 sv1…host name, vol1…share name
Example of Job file, Log file, and Data file:
"\\sv1\vol1\mach03\get_temp.jog" absolute path spec. sv1…host, vol1…share name
"g: \euro\mach01\get_temp.jog" The left one cannot be used.(※ The drive name
cannot be recognized.)
"/sv1/vol1/mach03/get_temp.jog" Linux path cannot be used.
"mach01\get_temp.job" relative path spec.(Relative to “Session path”)
"\\sv1\vol1\mach01\any.log" absolute path spec. sv1…host, vol1…share name
"\\sv3\vol1\mach01\cycdata.rep" absolute path spec. sv3…host, vol1…share name
As long as the host computer is the one set on the screen, JOB file, JOB response file, and DATA file can be
read-out or written-in in the session path or any other places such as other holders or PCs.

(4) Maximum number of each demand that can be executed at the same time
MaxSessins 50 maximum number of sessions supported by a machine.
MaxJobs 120 Max. count jobs
MaxReports 25 Max. active reports
MaxReports (ALARMS) 25 Max. active events for ALARMS type
MaxReports (CURRENT_ALARMS) 25 Max. active events for CURRENT_ALARMS type
MaxReports (CHANGES) 25 Max. active events for CHANGES type
※ Multiple numbers of demands made at the same time may exceed the execution capability.

(5) Character code specification


By selecting “Standard” or “UTF-8”, you can decide the character code of the character string that is output in
alarm messages and GETID.
[Standard] : The following character code is output;
ISO8859-1/2/8/9 KOI8-R(Russian) TIS620(Thai) SHIFT_JIS(Japanese)
EUCCN(Simplified Chinese) BIG-5(Traditional Chinese) EUCKR(Hangul)
[UTF-8]: Output is made in the character code of UTF-8.

-5-
C15149P
REGISTERD No. 1808-680602
(6) Change of settings
You can change production control-related settings only. You cannot change molding conditions.
Using SET command, you can change the settings on the PRODUCTION CONTROL screen from the host
computer.
Token of counter
(To reset the counter, set the space for the measured value at “0”.)
Setting Measurement
No. of cycles ActCntCyc
Divided lot @SetCntCnt_Rlot @ActCntRLot
No.
Lot No. SetCntCyc @ActCntLot
To use counters, set each counter to ON.
(Refer to Operation Manual, 4-5.)
Token of product data
Product SetDescJob 32 characters *1
name
Mold name SetDescMld 16 characters *1
Resin SetDescMat[1,1] 16 characters *1
name
*1 To enter characters, you can use English single
byte characters only.
You cannot use symbols, such as /:,;*?<>|.
Using SET command, you can change the setting on the SCHEDULE window from the host computer.
Product lot @SetCslt_Lot
No.
Delivery year, @SetCslt_yy、@SetCslt_mm、
month, day, @SetCslt_dd
hour, minute
@SetCslt_hh、@SetCslt_mn
Working hour @SetCslt_hh1、@SetCslt_mn1
Start:
hour,minute @SetCslt_hh2、@SetCslt_mn2
End; hour,
minute
Operation day @SetCslt_wmod_0 ~
(Sun. to Sat.) @SetCslt_wmod_6
Monitoring @SetCslt_csmd
mode (0=OFF 1= monitor 2= suspending)

-6-
C15149P
REGISTERD No. 1808-680702

4. Notes on ftp
・Toyo checked and confirmed that the ftp setver can work properly on FileZilla Server 0.9.37.
・To make a file access, make Read, Write, Delete, and Append effective.
・Combined use of ftp communication and share file cannot be made.
・Shared name is not used.
Exp. Session Path (absolute path)
\\SV1\INTERFACE\MACH01 SV1…host name, \INTERFACE\MACH01…directory name
\\sv1\vol1\machh03 sv1…host name, \vol1\machh03…directory name

Exp. Job file, Log file, Data file


"\\sv1\vol1\mach03\get_temp.jog" absolute path spec. sv1…host, \vol1\mach03…directory
"g: \euro\mach01\get_temp.jog" absolute path spec. * This cannot be used. (g: unrecognizable)
"mach01\get_temp.job" relative path spec.(Relativity from a Session pass)
"\\sv1\vol1\mach01\any.log" absolute path spec. sv1…host, \vol1\mach01…directory
"\\sv3\vol1\mach01\cycdata.rep" absolute path spec. sv3…host, \vol1\mach01…directory

・When transfer of the ftp file is not completed within 10 seconds, file transfer is retried.
・The session demanding file monitors the session path of the host computer every 2 seconds,
and acquiresthe file, if any.

5. EUROMAP 63 Commands
SESSION Command
・CONNECT Connection Verification.
・EXECUTE execute a Job command file.
PRESENTATION Command (JOB Files)
・JOB indicating the start of the JOB command.
・REPORT used to generate a data report. (monitor data, machine status, setup data)
・EVENT ALARMS used to log alarm events.
・EVENT CURRENT_ALARMS used to obtain a list of all currently set or active alarms.
・EVENT CHANGES used to log machine setup parameter changes as entered by the machine operator.
・ABORT start of the Abort request. Abort JOB,REPORT,EVENT executing.
・UPLOAD upload of a setup dataset. direction from machine to host.
・DOWNLOAD download of a setup dataset. direction from host to machine.
・GETINFO an upload of a hard- and software information of a machine.
・GETID upload of all available variables.
・SET This command is used to set a variable to a specific machine.

-7-
C15149P
REGISTERD No. 1808-680802
6. Tokens
(1) IMM Device Token
Tokens are names to use for designation of values of monitor data, setting, molding machine
conditions for REPORT,EVENT, and SET command.
The naming method is stipulated in EUROMAP 63: for example,
SET for setting, Act for measurement, and Tim for timer.
Even in case of setting token (SetTimXxx), you cannot change the values in items of molding conditions
with SET command.
There are two kinds of tokens: one stipulated by EUROMAP 63; the other, added by molding machine
makers. (Refer to 9. Token list for detail.)

Example: Tokens stipulated by EUROMAP 63


(token) (Item)
SetDescMach MACHINE MODEL
SetTimMach CLOCK SETUP(Clock Synchronization)
ActStsMach MOLDING MACHINE STATE(Actual Machine Status)
SetCntCyc LOT No (Number of Machine Cycles Requested for Prod Run)
ActCntCyc CYCLE SHOT(Actual Cycle Count)
SetDescJob PRODUCT NAME ,COMMENT (Job Name / Description)
SetCfgBrlZn[1,1] HEATER 1 on/off(Barrel Temperature Zone Configuration. )
SetTmpBrlZn[1,1] HEATER 1 MAIN(Barrel Temperature Zone Set Temperatures)
ActTmpBrlZn[1,1] HEATER 1 ACTUAL(Barrel Temperature Zone Actual Temperatures.)
ActTimFill[1] FILL INJECTION TIME(Actual Fill Time for each injection unit.)
SetTimCyc CYCLE TIMER(Overall Cycle Time Setpoint.)
ActStrCsh[1] CUSHION POSITION(Actual Stroke Position at Cushion for each injection unit.)
ActDiaScr[1] SCREW DIAMETER(Actual Screw Diameter for each injection unit.)
ActPrsXfrSpec[1] FILL PRESSURE(Specific Pressure at Transfer Actual for each injection unit.)
TIME CURRENT TIME(pseudo token)
DATE CURRENT DATE(pseudo token)
COUNT CURRENT REPORT record number(pseudo token)
Example: To identify the token as a vendor specific token, the at symbol '@' is used as a prefix to the token
symbol.
(token) (Item)
@ActStrInj INJECTION STROKE ACTUAL
@ActCntLot LOT COUNTER
@ActStrInjVP[1] MONITOR - V-P SWITCH-OVER POSISION
@ActStrInjMax[1] MONITOR - STROKE MAXIMUM
@ActTmon01 MONITOR ITEM No.01
@ActTmon02 MONITOR ITEM No.02
@SetStrInj_S_1[1] INJECTION 2V CHANGE-OVER POSISION
@SetStrInj_S_2[1] INJECTION 3V CHANGE-OVER POSISION
@SetStrInj_S_10[1] V-P SWITCH-OVER POSITION

-8-
C15149P
REGISTERD No. 1808-680902
(2) Non-support token

The following tokens appointed with EUROMAP 63 specifications are not supported.( Items in 9.-(2) Token
list)
SetDescMatLot[1,1] SetRecMld SetRecMldNxt SetCntPrtBox ActCfgBrl[1] SetDescBrlZn[1,1]
SetTmpBrlZnStb[1,1] SetTmpBrlZnHlmt[1,1] SetTmpBrlZnLlmt[1,1] SetDescMldZn[1]
SetTmpMldZnStb[1] SetTmpMldZnHlmt[1] SetTmpMldZnLlmt[1] ActTmpOil
SetTmpOil ActTmpWtrIn ActTmpWtrOut ActTmpCab ActTmpMlt
SetDiaScr[1] ActStrDcmpPre[1] ActVolDcmpPre[1] ActStrDcmpPst[1] ActVolDcmpPst[1]
SetStrXfr[1] SetVolXfr[1] ActPrsXfrHyd[1] SetPrsXfrHyd[1]
ActPrsXfrCav[1] SetPrsXfrCav[1] ActTimXfr[1] SetTimXfr[1]
ActPrsCavMax ActPrsMachHydMax
ActSpdPlstMax[1] ActSpdPlstAve[1] ActVelPlstMax[1] ActVelPlstAve[1]
ActPrsHldHydMax ActPrsHldHydAveMax ActPrsHldSpecMax ActPrsHldSpecAveMax
ActPrsPlstHydMax ActPrsPlstHydAveMax ActPrsPlstSpecMax ActPrsPlstSpecAveMax

Pos.3(Assist Call) of ActStsMach is not covered. “0” is returned always.

-9-
C15149P
REGISTERD
REGISTERD No.
No. 1808-6801002
1808-681102
7. Command details (See. EUROMAP63.)
(1) SESSION Request Command
{sessionID} CONNECT; sessionID=Session identify(8 letters)
{sessionID} EXECUTE {fspec}; sessionID=Session identify(8 letters) fspec=Job file specification
Execution at the same time is possible in several JOB by specifying it several EXECUTE JOB files.

(2) JOB File Command


JOB {name} RESPONSE {fspec}; name=Job request identify fspec=JOB response file
REPORT {name} APPEND|REWRITE {fspec} name=Report identify fspec=Report File
{start} {stop} start=Start specification stop=Stop specification
[IF [NOT] {token} {cmp} {const} | CHANGE] start of a conditional REPORT.
[CYCLIC [TIME {const} | SHOT {const} ] specify whether the parameters are recorded
only once or cyclic.
[SAMPLES {const} ] specifies the number of successive recording samples
to issue.
[SESSIONS {const} ] specifies the total number of recording sessions to REPORT.
PARAMETERS , {token}, .... {tiken}; start of the list of parameters to be reported.
EVENT {name} name=name of the event.
{type} type=ALARMS/CURRENT_ALARMS/CHANGES
APPEND|REWRITE {fspec} fspec=network file specification which specifies the event file.
{start} {stop}; start=Start specification stop=Stop specification
ABORT ALL [JOBS|REPORTS|EVENTS] all active operations of the specified type are aborted.
ABORT JOB {name} | REPORT {name} | EVENT {name} JOB/REPORT/EVENT {name} is to be aborted.
UPLOAD {fspec} ACTIVE | {av_fspec} fspec=Upload file specifying av_fspec= Product name
| {gen_keyword} | {start_spec}; gen_keyword=Maker-specific keyword start_spec= Start condition
DOWNLOAD {fspec} ACTIVE | {av_fspec} fspec=Download file specifying av_fspec=Product name
| {gen_keyword} | {start_spec}; gen_keyword=Maker-specific keyword start_spec=Start condition
GETINFO {fspec}; fspec=network file specification
GETID {fspec}; fspec=network file specification
SET {token} {const}; token=parameter ID token const=value of the variable
(You cannot change values in items of molding conditions.)

(3) JOB file Extensions


In EUROMAP 63 specifications, one JOB file can accommodates only one command (except for SET
command).
But in this communication control, EUROMAP 63 is extended so that one JOB file can accommodate
multiple commands.
Commands are executed sequentially but not simultaneously.
Note : This extension cannot be used with IMMs made by other companies. Even if you abort the currently
executing command, remaining command is initiated.

- 10 -
C15149P
REGISTERD No. 1808-6801102
REGISTERD No. 1808-681202
(4) REPORT command PATAMETER tokens
When you appoint the token of the monitored data, set a monitor No. on the MONITOR ITEM screen.
During automatic operation, the same values as those of the monitored data are output. While the machine is
not in automatic operation, measured values may be output in some cases.
Monitor item direct specification
If you appoint @ActDateTime at PARAMETERS items, date and time are acquired in the form of
"yyyy/mm/dd hh:mm:ss".
If you appoint @ActTmon01-32 at PARAMETERS items, you can acquire the data of the same item as that
on the Monitor screen.

(5) Command commonness


START/STOP/IF clause make a judgment according to EUROMAP 63 specification.
STOP judgment is made after START judgment is made. When conditions are established at the same time,
judgment is made one second after next cycle is started.
In case of STOP judgment, data are not output.
Even if you appoint measured value of the machine at START/STOP judgment, judgment is not correct
because judgment is made every one second.
In IF CHANGE / IF NOT CHANGE, the data for the first cycle cannot be recorded.

(6) REPORT command


A title line is added at the first cycle. A title line is also added when REPORT file is deleted on the host side.

(7) EVENT ALARMS command


You can acquire alarm generation history.
The same contents as those of the Alarm History screen are output.

(8) EVENT CURRENT_ALARMS command


You can acquire the alarm that is currently on display.
The same alarm as that currently on the screen is output.

(9) EVENT CHANGES command


You can acquire setting changing history.
The same contents as those of SETUP RECORD screen are output. Changes on the FIXED DATA screen
are not Output(except for some values).
During downloading, the message "DOWNLOAD FROM HOST" is output.
During loading of conditions on the IMM’s screen, the message "DATA MEMORY LOAD" is output.

(10) GETINFO command


an upload of a hard- and software information of a machine.
You can observe the command(JOB) currently in execution.

- 11 -
C15149P
REGISTERD No. 1808-6801202
REGISTERD No. 1808-681302
(11) GETID command
upload of all available variables.
Units, such as C(℃) F(゚ F) um(μm) kgf/cm2, and mm/s2, are used.

(12) ABORT command


This command stops or suspends the currently executing command.

(13) UPLOAD/DOWNLOAD command


a.Outline
Obtaining molding conditions and changing molding conditions can be made by using an
obtained file.
b.Detail
UPLOAD (IMM HOST)
HOST COMPUTER
DOWNLOAD (HOST IMM)

IMM : Molding machine


⑤ ②


Execution Execution
memory memory
(ACTIVE) (ACTIVE)
⑦ ③

Internal Internal
memory memory
(ARCIVE) (ARCIVE)

Table 1. Molding conditions file transfer table


File transfer diretion Command {fspec} Keyword {av_fspec} {gen_keyword} {start}
① Execution memory UPLOAD {directry¥file} ACTIVE TOYO_ASC
HOST(Txt)*
② Execution memory HOST UPLOAD {directry} ACTIVE Product name

③ Execution memory UPLOAD "" ARCHIVES Product name


Internal memory
④ Internal memory HOST UPLOAD {directry} Product name

⑤ HOST DOWNLOAD {directry¥file} ACTIVE TOYO_ASC


Execution memory( Text)
⑥ HOST Execution memory DOWNLOAD {directry} ACTIVE Product name

⑦ Internal memory DOWNLOAD "" ARCHIVES Product name


Execution memory
⑧ HOST Internal memory DOWNLOAD {directry} Product name

- 12 -
C15149P
REGISTERD
REGISTERD No.
No. 1808-6801302
1808-681402
・UPLOAD You can obtain molding conditions. You can use the obtained file for downloading.
If you use UPLOAD/DOWNLOAD, you can manage molding conditions on the host side.
・DOWNLOAD You can change molding conditions using the file obtained by uploading.
Downloading is prohibited when motors are ON.
After downloading, the machine is in the state of “during screw cold start prevention”
and “mold clamping force has not been established.”
・ACTIVE Keyword to specify the execution memory
・ARCHIVE Keyword to specify the internal memory.
・TOYO_ASC Keyword to specify the text condition file.

c. EUROMAP63 setting window

・SETTING FILE MANAGER Text ON/OFF


ON :Molding conditions file is in text data specification.
Table 2.Text data table
File transfer direction Command {fspec} Keyword {start}
① Execution memory HOST( Text ) UPLOAD {directry¥file} ACTIVE
⑤ HOST Execution memory (Text) DOWNLOAD {directry¥file} ACTIVE

②,③,④,⑥,⑦,⑧ in Table 1 Molding conditions file transfer table are ineffective.

When you make a selection setting, figures are output.


If you change test data files, downloading cannot be made.
(You cannot specify ACTIVE and ARCHIVE.)
OFF: Molding conditions file is in binary data specification.
・ftp mode (Euromap63 system)
You cannot use multi-byte characters for directory names, file names {fspec} and product
names {av_fspec}: Japanese characters, Chinese characters, Å and the like.

(14) SET command


This command is used to set a variable to a specific machine.
(Only when “SETTING CHANGE ALLOWED” is[ON].)
Example: SET SetTimMach 23580020140531; Set the date and the time on the host computer to IMM.
(Setting cannot be made during automatic operation.)

- 13 -
C15149P
REGISTERD No.
REGISTERD No. 1808-6801402
1808-681502
8. Use example … The following is communication procedure in actual use assumable.

(1) Connection Verification


REQ_0001 CONNECT;

(2) Clock Synchronization (Synchronize the time of molding machine with a host.) (Setting cannot be made
during automatic operation.)
SET SetTimMach 12000020140601; // Current Time/Date

(3) All available variables from an IMM, obtain information from an IMM
GETID "\\NTWK71\Euromap63\data\config.dat";
GETINFO "\\NTWK71\Euromap63\data\mach_00.inf";

(4) DOWNLOAD a setup data set (Specify the setup data file which did last time UPLOAD.)
(When IMM’s motors are ON, download cannot be made.)
DOWNLOAD \\NTWK71\Euromap63\data\dataset_5

(5) COUNTER SETTING


SET SetCntCyc 10000; // LOT Counter Setting
SET ActCntCyc 0; // LOT Counter Clear
SET @ActCntLot 0; // SHOTCounter Clear

(6) REPORT,EVENT Command Request at AM 8:00 - PM 18:00


REPORT spc APPEND "\\NTWK71\Euromap63\data\spc.dat" (*1)
START TIME>= 08:00:00 STOP TIME>= 18:00:00 CYCLIC
PARAMETERS DATE, TIME, COUNT, ActCntCyc, ActStrCsh[1],
@ActTmon01, @ActTmon02, @ActTmon03, @ActTmon04, @ActTmon05;
REPORT status REWRITE "\\NTWK71\Euromap63\data\status.dat" (*1)
START IMMEDIATE STOP NEVER CYCLIC TIME 00:00:10 PARAMETERS TIME, DATE,
ActStsMach, ActCntCyc, ActTimCyc;
EVENT myEventAlarms ALARMS APPEND "\\NTWK71\Euromap63\data\alr.dat" (*1)
START TIME>= 08:00:00 STOP TIME>= 18:00:00 ;
EVENT myAlarms CURRENT_ALARMS REWRITE
*1 Access the data file with
"\\NTWK71\Euromap63\data\alarm.dat" (*1) READ OPEN (reading-only file).
Do not lock the file.
START IMMEDIATE STOP NEVER;
EVENT myEventChg CHANGES APPEND "\\NTWK71\Euromap63\data\chg.dat" (*1)
START IMMEDIATE STOP TIME>= 18:00:00 ;
UPLOAD "\\NTWK71\Euromap63\data\upload.stp"
ACTIVE START TIME>= 18:00:00 ;

- 14 -
C15149P
REGISTERD No. 1808-6801502
REGISTERD No. 1808-681602
(7) AM 8:00 Start operation by an operator

(8) AM 8:00 - PM 18:00 host computer side


spc.dat status.dat alr.dat alarm.dat chg.dat (These are monitor data and machine conditions
that are monitored.)
Information is collected at regular intervals with
GETINFO "\\NTWK71\Euromap63\data\mach_00.inf";

(9) PM 17:30 Stop operation by an operator

(10) PM 18:00 Conditions are acquired by “upload.stp” and compared with “dataset_5”, so that any setting
change can be recognized.

(11) PM 18:10 Stop JOB executing


ABORT REPORT status;
ABORT REPORT myAlarms;

- 15 -
C15149P
REGISTERD No. 1808-6801602
REGISTERD No. 1808-681702
9. Token table
(1) Monitor tokens …Refer to Operation Manual, 4-6) a. Monitoring items.
No Token Item Description
Position where 1st injection is switched to holding
1 @ActStrInjVP[1] V-P SWITCH-OVER POS.
pressure.
2 ActStrCsh[1] CUSHION POSITION Injection completion position
3 @ActStrInjMax[1] STROKE MAXIMUM (Injection start position) - (Minimum cushion position)
4 @ActStrInjFil[1] STROKE FILL PRESS. (Injection start position) -(V-P switch-over position)
5 ActStrXfr[1] STROKE INJ. END (Injection start position) - (Cushion position)
6 ActStrPlst[1] PLASTICIZING POSN. Plasticizing completion position
1cycle time (from injection completion to injection
8 ActTimCyc CYCLE TIME
completion in the next cycle)
9 ActTimFill[1] FILL INJ. TIME Time spent for 1st injection
10 ActTimPlst[1] PLASTICIZING TIME Time spent for plasticizing
11 @ActTimDcmpPst SUCK BACK TIME Suck back time
Time from mould opening start to mould opening
12 @ActTimMldOpn MOULD OPEN TIME
completion
Time from mould closing start to mould closing
13 @ActTimMldCls MOULD CLOSE TIME
completion
Time from mould opening completion to mould
14 @ActTimTakeout TAKE OUT TIME
closing start
15 @ActVelInj_V_0[1] 1ST V 1st injection speed
16 @ActVelInj_V_1[1] 2ND V 2nd injection speed
17 @ActVelInj_V_2[1] 3RD V 3rd injection speed
18 @ActVelInj_V_3[1] 4TH V 4th injection speed
19 @ActVelInj_V_4[1] 5TH V 5th injection speed
20 @ActVelInj_V_5[1] 6TH V 6th injection speed
21 @ActVelInj_V_6[1] 7TH V 7th injection speed
25 ActPrsXfrSpec[1] 1ST P Pressure at the time of injection with 1st pressure
26 @ActPrsInj_P_1[1] 2ND P Pressure at the time of injection with 2nd pressure
27 @ActPrsInj_P_2[1] 3RD P Pressure at the time of injection with 3rd pressure
28 @ActPrsInj_P_3[1] 4TH P Pressure at the time of injection with 4th pressure
29 @ActPrsInj_P_4[1] 5TH P Pressure at the time of injection with 5th pressure
30 @ActPrsInj_P_5[1] 6TH P Pressure at the time of injection with 6th pressure
31 @ActPrsInj_P_6[1] 7TH P Pressure at the time of injection with 7th pressure
44 @ActPrsInj1_Str[1] PRESSURE 1 (POSN.1) Pressure at an arbitrary position 1
45 @ActVelInj1_Str[1] SPEED 1 (POSN.1) Speed at arbitrary position 1
46 @ActPrsInj2_Str[1] PRESSURE 2 (POSN.2) Pressure at arbitrary position 2
47 @ActVelInj2_Str[1] SPEED 2 (POSN.2) Speed at arbitrary position 2
48 @ActPrsInj3_Str[1] PRESSURE 3 (TIME.1) Pressure at arbitrary time 1
49 @ActVelInj3_Str[1] SPEED 3 (TIME.1) Speed at arbitrary time 1
50 @ActPrsInj4_Str[1] PRESSURE 4 (TIME.2) Pressure at arbitrary time 2
51 @ActVelInj4_Str[1] SPEED 4 (TIME.2) Speed at arbitrary time 2
Time required to reach arbitrary pressure from
52 @ActTim_PrsRiseUp[1] INJ. RISE UP TIME
injection start
53 ActPrsMachSpecMax MAXIMUM PRESSURE Maximum pressure at injection
54 @ActPrsMachSpecMin[1] MINIMUM PRESSURE Minimum pressure at injection
55 @ActVelMachSpecMax[1] MAXIMUM SPEED Maximum speed at injection
56 @ActVelMachSpecMin[1] MINIMUM SPEED Minimum speed at injection
57 @ActSpdPlst_Vc_0[1] REV 1 Screw revolution speed at 1st plasticizing speed
58 @ActSpdPlst_Vc_1[1] REV 2 Screw revolution speed at 2nd plasticizing speed
59 @ActSpdPlst_Vc_2[1] REV 3 Screw revolution speed at 3rd plasticizing speed
63 @ActRevPlst_Vc_0[1] PLASTICIZING REV.1 Revolution amount at 1st plasticizing speed
64 @ActRevPlst_Vc_1[1] PLASTICIZING REV.2 Revolution amount at 2nd plasticizing speed
65 @ActRevPlst_Vc_2[1] PLASTICIZING REV.3 Revolution amount 3rd plasticizing speed
69 @ActPrsPlst_Pc_0[1] BACK PRESSURE 1 Back pressure at 1st plasticizing speed
70 @ActPrsPlst_Pc_1[1] BACK PRESSURE 2 Back pressure at 2nd plasticizing speed
71 @ActPrsPlst_Pc_2[1] BACK PRESSURE 3 Back pressure at 3rd plasticizing speed
75 @ActRevPlst_Total[1] TOTAL REVOLUTION Total revolution amount in plasticizing
76 ActTmpBrlZn[1,1] HEATER 1 TEMP. Measured heater 1 temperature
77 ActTmpBrlZn[1,2] HEATER 2 TEMP. Measured heater 2 temperature

- 16 -
C15149P
REGISTERD
REGISTERD No.
No. 1808-681802
1808-6801702
78 ActTmpBrlZn[1,3] HEATER 3 TEMP. Measured heater 3 temperature
79 ActTmpBrlZn[1,4] HEATER 4 TEMP. Measured heater 4 temperature
80 ActTmpBrlZn[1,5] HEATER 5 TEMP. Measured heater 5 temperature
81 ActTmpBrlZn[1,6] HEATER 6 TEMP. Measured heater 6 temperature
82 @ActTmpHop[1] HOPPER TEMPERATURE Measured below-hopper temperature
83 ActTmpMldZn[1] MOULD 1 TEMPERATURE Measured mould 1 temperature
84 ActTmpMldZn[2] MOULD 2 TEMPERATURE Measured mould 2 temperature
85 ActTmpMldZn[3] MOULD 3 TEMPERATURE Measured mould 3 temperature
Secondary mould closing position in injection
94 @ActStrMld2ndCls 2NDARY CLOSE POS.
compression
95 @ActStrMld2ndOpn MOULD OPEN VOLUME Mould opening volume in injection compression
Secondary mould closing time in injection
96 @ActTimMld2ndCls 2NDARY CLOSE TIME
compression
97 @ActPrsInjRemain_OreOpn[1] REMAINED P (OPEN ST) Measured resin pressure at mould opening start
98 @ActPrsInjRemain_PreInj[1] REMAINED P. (INJ. ST) Measured resin pressure at injection start
99 @ActPrsPlst_PstPlst[1] B-PRESS. (PLASTI.E) Back pressure at plasticizing completion
100 @ActStrMld_Cmprs1 COMPRESSION POSN. 1 - (Optional)
105 ActFrcClp CLAMP FORCE (INJ ST) - (Optional)
106 @ActFrcClp_PstInj CLAMP FORCE(INJ EN) Clamping force at injection completion
Injection position at the completion of the 2nd
111 @ActStrInj_P_1[1] HOLD P. POS 2nd
pressure
Injection position at the completion of the 3rd
112 @ActStrInj_P_2[1] HOLD P. POS 3rd
pressure
113 @ActStrInj_P_3[1] HOLD P. POS 4th Injection position at the completion of the 4th pressure
114 @ActStrInj_P_4[1] HOLD P. POS 5th Injection position at the completion of the 5th pressure
115 @ActStrInj_P_5[1] HOLD P. POS 6th Injection position at the completion of the 6th pressure
116 @ActStrInj_P_6[1] HOLD P. POS 7th Injection position at the completion of the 7th pressure
Time required to reach target speed from injection
117 @ActTim_VelRiseUp[1] INJ. SPEED RISE UP TIME
start
201 @ActTmpMldOptZn[1] MOULD 1 TEMP. - (Optional)
202 @ActTmpMldOptZn[2] MOULD 2 TEMP. - (Optional)
203 @ActTmpMldOptZn[3] MOULD 3TEMP. - (Optional)
204 @ActTmpMldOptZn[4] MOULD 4 TEMP. - (Optional)
205 @ActTmpMldOptZn[5] MOULD 5 TEMP. - (Optional)
206 @ActTmpMldOptZn[6] MOULD 6 TEMP. - (Optional)
207 @ActTmpMldOptZn[7] MOULD 7 TEMP. - (Optional)
208 @ActTmpMldOptZn[8] MOULD 8 TEMP. - (Optional)
209 @ActTmpMldOptZn[9] MOULD 9 TEMP. - (Optional)
210 @ActTmpMldOptZn[10] MOULD 10 TEMP. - (Optional)
217 @ActStrInj_PrePlst[1] PLAST. START POSN. Screw rotation start position for metering
219 @ActStrCsh_Min[1] MIN. CUSHION POSN. Minimum cushion
221 @ActPrsInjRemain_PstPlst[1] REMAINED P.(SB ST.) Measured resin pressure at suck back start
222 @ActPrsInjRemain_PreDcmp[1] REMAINED P.(SB END) Measured resin pressure at suck back completion
223 @ActTrqLowPrs LOW-PRS. TRQ. Measured torque in low mould protection
224 @ActTimLowPrs LOW-PRS. TIME Time required for low mould protection
225 @ActTmpMldOptZn[11] MOULD 11 TEMP. - (Optional)
226 @ActTmpMldOptZn[12] MOULD 12 TEMP. - (Optional)
227 @ActTmpMldOptZn[13] MOULD 13 TEMP. - (Optional)
228 @ActTmpMldOptZn[14] MOULD 14 TEMP. - (Optional)
229 @ActTmpMldOptZn[15] MOULD 15 TEMP. - (Optional)
230 @ActTmpMldOptZn[16] MOULD 16 TEMP. - (Optional)
231 @ActTmpMldOptZn[17] MOULD 17 TEMP. - (Optional)
232 @ActTmpMldOptZn[18] MOULD 18 TEMP. - (Optional)
233 @ActTmpMldOptZn[19] MOULD 19 TEMP. - (Optional)
234 @ActTmpMldOptZn[20] MOULD 20 TEMP. - (Optional)
242 @ActTim_IntChgtim INTRUSION PLAST. TIME Time required for intrusion plasticizing
243 @ActTrqMax_RevPlst MAX. PLAST. TORQUE Maximum torque detected during plasticizing
244 @ActPrsMax_Plst MAX. BACK PRESSURE Maximum back pressure detected during plasticizing
245 @ActTimNzTouch NOZZLE TOUCH TIME Time required for nozzle touch
246 @ActTimNzRetract NOZZLE RETRACT TIME Time required for nozzle retraction
262 @ActPrsMachSpecMax_1P[1] 1ST INJ MAX. PRESSURE Maximum pressure during first injection

- 17 -
C15149P
REGISTERD No.
REGISTERD No. 1808-6801802
1808-681902
INJ HOLDING PRESS MAX.
263 @ActVelHldMax[1] Maximum speed during pressure holding process
SPEED
270 @ActStrPlst_PreSrc2[1] SRC START POSITION Injection position at the start of SRC
271 @ActStrPlst_PstSrc2[1] SRC END POSITION Injection position at the end of SRC
280 @ActMeltViscosity MELT VISCOSITY Melt viscosity 1 (Measured melt viscosity)

(2) EUROMAP 63 specification token Support : no…Non-support token SET…SET Command permission
*1…Optional, *2…Effective when PRODUCTION CONTROL MONITORING MODE mode is set to “MONITORING”
Sup
Token Item Description
port
TIME CURRENT TIME A pseudo parameter used to specify
DATE CURRENT DATE A pseudo parameter used to specify
COUNT CURRENT REPORT record number A pseudo parameter used to specify
SetDescMach MACHINE MODEL Customer Device Description.
SET SetTimMach CLOCK SETUP Clock Synchronization
ActStsMach MOLDING MACHINE STATE Actual Machine Status.
*1 Actual Cycle Status. Reason why machine is not
ActStsCyc Stop condition, reason
currently in cycle.
SET SetCntCyc LOT No. Number of Cycles Requested for Production Run
SET ActCntCyc CYCLE SHOT Actual Cycle Count (“0”setting clears counter.)
*2 ActCntCycRej Defect counter Production Rejects - Process Control
*2 ActCntPrtRej No. of defects(× No. of cavity) Number of Rejected parts
SET SetDescJob PRODUCT NAME (COMMENT) Job Name / Description
SetDescOp OPEATER NAME Operator ID
SetDescPrt Part name Part Name / Description
SET SetDescMld MOULD NUMBER Mold or Tool Name / Description
SET SetDescMat[1,1] RESIN NAME Material Name
no SetDescMatLot[1,1] Material Lot Number
no SetRecMld Mold Setup (Recipe) File Name
SetCntMld Number of cavity Set Mold Count - Number of Cavities Run
ActCntMld Number of cavity Act Mold Count - Number of Cavities Run
no SetRecMldNxt Setup (Recipe) File Name of Next Mold to Run
no SetCntPrtBox Part Box Count
SetCntPrt No. of product lot(× No. of cavity) Piece Counter
*2 ActCntPrt No. of products(× No. of cavity) Piece Counter
no ActCfgBrl[1] Barrel Configuration
no SetDescBrlZn[1,1] Barrel Zone Description / Name.
SetCfgBrlZn[1,1] HEATER 1 on/off Barrel Temperature Zone Configuration.
SetCfgBrlZn[1,2] HEATER 2 on/off
SetCfgBrlZn[1,3] HEATER 3 on/off
SetCfgBrlZn[1,4] HEATER 4 on/off
SetCfgBrlZn[1,5] HEATER 5 on/off
SetCfgBrlZn[1,6] HEATER 6 on/off
SetTmpBrlZn[1,1] HEATER 1 MAIN Barrel Temperature Zone Set Temperatures
SetTmpBrlZn[1,2] HEATER 2 MAIN
SetTmpBrlZn[1,3] HEATER 3 MAIN
SetTmpBrlZn[1,4] HEATER 4 MAIN
SetTmpBrlZn[1,5] HEATER 5 MAIN
SetTmpBrlZn[1,6] HEATER 6 MAIN
ActTmpBrlZn[1,1] HEATER 1 ACTUAL Barrel Temperature Zone Actual Temperatures.
ActTmpBrlZn[1,2] HEATER 2 ACTUAL
ActTmpBrlZn[1,3] HEATER 3 ACTUAL
ActTmpBrlZn[1,4] HEATER 4 ACTUAL
ActTmpBrlZn[1,5] HEATER 5 ACTUAL
ActTmpBrlZn[1,6] HEATER 6 ACTUAL
Barrel Temperature Zone Standby Set
no SetTmpBrlZnStb[1,1]
Temperatures.

- 18 -
C15149P
REGISTERD No. 1808-6801902
REGISTERD No. 1808-682102
SetTmpBrlZnHdev[1,1] HEATER 1 UPPER Barrel Temperature Zone High Deviation Setpoint.
SetTmpBrlZnHdev[1,2] HEATER 2 UPPER
SetTmpBrlZnHdev[1,3] HEATER 3 UPPER
SetTmpBrlZnHdev[1,4] HEATER 4 UPPER
SetTmpBrlZnHdev[1,5] HEATER 5 UPPER
SetTmpBrlZnHdev[1,6] HEATER 6 UPPER
SetTmpBrlZnLdev[1,1] HEATER 1 LOWER Barrel Temperature Zone Low Deviation Setpoint.
SetTmpBrlZnLdev[1,2] HEATER 2 LOWER
SetTmpBrlZnLdev[1,3] HEATER 3 LOWER
SetTmpBrlZnLdev[1,4] HEATER 4 LOWER
SetTmpBrlZnLdev[1,5] HEATER 5 LOWER
SetTmpBrlZnLdev[1,6] HEATER 6 LOWER
no SetTmpBrlZnHlmt[1,1] Barrel Temperature Zone High Limit Setpoint.
no SetTmpBrlZnLlmt[1,1] Barrel Temperature Zone Low Limit Setpoint.
no SetDescMldZn[1] Mold Zone Description / Name.
SetCfgMldZn[1] MOULD 1 on/off Mold Temperature Zone Configuration.
SetCfgMldZn[2] MOULD 2 on/off
SetCfgMldZn[3] MOULD 3 on/off
SetTmpMldZn[1] MOULD 1 MAIN Mold Temperature Zone Set Temperatures.
SetTmpMldZn[2] MOULD 2 MAIN
SetTmpMldZn[3] MOULD 3 MAIN
ActTmpMldZn[1] MOULD 1 ACTUAL Mold Temperature Zone Actual Temperatures.
ActTmpMldZn[2] MOULD 2 ACTUAL
ActTmpMldZn[3] MOULD 3 ACTUAL
no SetTmpMldZnStb[1] Mold Temperature Zone Standby Set Temperatures.
SetTmpMldZnHdev[1] MOULD 1 UPPER Mold Temperature Zone High Deviation Setpoint.
SetTmpMldZnHdev[2] MOULD 2 UPPER
SetTmpMldZnHdev[3] MOULD 3 UPPER
SetTmpMldZnLdev[1] MOULD 1 LOWER Mold Temperature Zone Low Deviation Setpoint.
SetTmpMldZnLdev[2] MOULD 2 LOWER
SetTmpMldZnLdev[3] MOULD 3 LOWER
no SetTmpMldZnHlmt[1] Mold Temperature Zone High Limit Setpoint.
no SetTmpMldZnLlmt[1] Mold Temperature Zone Low Limit Setpoint.
no ActTmpOil Oil Actual Temperature
no SetTmpOil Oil Set Temperature
no ActTmpWtrIn Water Intake Actual Temperature
no ActTmpWtrOut Water Outlet Actual Temperature
no ActTmpCab Cabinet Actual Temperature
no ActTmpMlt Melt Actual Temperature
ActTimFill[1] FILL INJECTION TIME Actual Fill Time for each injection unit.
ActTimPlst[1] PLASTISIZING. TIME Actual Plasticization Time for each injection unit.
SetTimCyc CYCLE TIMER Overall Cycle Time Setpoint.
ActTimCyc CYCLE TIMER ACTUAL Actual Cycle Time.
ActStrCsh[1] CUSHION POSITION c
ActVolCsh[1] CUSHION POSITION Actual Volume at Cushion for each injection unit.
ActStrPlst[1] PLASTICIZING POSITION Actual Plasticization Stroke for each injection unit.
SetStrPlst[1] INJECTION START POSITION Plasticization Stroke Setpoint for each injection unit.
ActVolPlst[1] PLASTICIZING POSITION Actual Plasticization Volume for each injection unit.
SetVolPlst[1] INJECTION START POSITION Plasticization Volume Setpoint for each injection unit.
ActDiaScr[1] SCREW DIAMETER Actual Screw Diameter for each injection unit.
no SetDiaScr[1] SCREW DIAMETER ACTUAL Screw Diameter Setpoint for each injection unit.
Actual Decompression Stroke Before Plasticization
no ActStrDcmpPre[1]
for each injection unit.
Decompression Stroke Before Plasticization Setpoint
SetStrDcmpPre[1] Injection Complete Suck-Back Width
for each injection unit.
Actual Decompression Volume Before Plasticization
no ActVolDcmpPre[1]
for each injection unit.
Decompression Volume Before Plasticization Setpoint
SetVolDcmpPre[1] Injection Complete Suck-Back Width
for each injection unit.

- 19 -
C15149P
REGISTERD No. 1808-6802002
REGISTERD No. 1808-682202
Actual Decompression Stroke After Plasticization for
no ActStrDcmpPst[1]
each injection unit.
Decompression Stroke After Plasticization Setpoint
SetStrDcmpPst[1] SUCK BACK
for each injection unit.
Actual Decompression Volume After Plasticization for
no ActVolDcmpPst[1]
each injection unit.
Decompression Volume After Plasticization Setpoint
SetVolDcmpPst[1] SUCK BACK
for each injection unit.
ActStrXfr[1] STROKE IJ.END Transfer Stroke Actual for each injection unit.
no SetStrXfr[1] Transfer Stroke Setpoint for each injection unit.
ActVolXfr[1] STROKE IJ.END Transfer Volume Actual for each injection unit.
no SetVolXfr[1] Transfer Volume Setpoint for each injection unit.
Hydraulic Pressure at Transfer Actual for each
no ActPrsXfrHyd[1]
injection unit.
Hydraulic Pressure at Transfer Setpoint for each
no SetPrsXfrHyd[1]
injection unit.
Cavity Pressure at Transfer Actual for each injection
no ActPrsXfrCav[1] CAVITY P.(HOLD)
unit.
Cavity Pressure at Transfer Setpoint for each injection
no SetPrsXfrCav[1] CAVITY PRESSURE
unit.
Specific Pressure at Transfer Actual for each injection
ActPrsXfrSpec[1] FILL PRESSURE
unit.
Specific Pressure at Transfer Setpoint for each
SetPrsXfrSpec[1] FILL PRESSURE
injection unit.
no ActTimXfr[1] Time of Transfer Actual (relative from start of cycle)
no SetTimXfr[1] Time of Transfer Setpoint (relative from start of cycle)
no ActPrsCavMax Peak cavity pressure(filling) Cavity Maximum Pressure Actual
Machine Hydraulic Pressure Actual Maximum during
no ActPrsMachHydMax
cycle.
Machine Specific Pressure Actual Maximum during
ActPrsMachSpecMax 1ST INJ. MAX PRESS
cycle.
Maximum plasticizing screw Plasticization Speed Actual Maximum for each
no ActSpdPlstMax[1]
revolution injection unit.
Average plasticizing screw Plasticization Speed Actual Average for each injection
no ActSpdPlstAve[1]
revolution unit.
Maximum plasticizing screw Plasticization Velocity Actual Maximum for each
no ActVelPlstMax[1]
retracting speed injection unit.
Average plasticizing screw Plasticization Velocity Actual Average for each
no ActVelPlstAve[1]
retracting speed injection unit.
ActFrcClp MOULD CLAMP FORCE Clamp Force Actual
SetFrcClp CLAMP FORCE Clamp Force Setpoint
no ActPrsHldHydMax Hold Hydraulic Pressure Actual Maximum
no ActPrsHldHydAveMax Hold Hydraulic Pressure Actual Average
Maximum holding pressure (melt Hold Specific Pressure Actual Maximum
no ActPrsHldSpecMax
pressure)
Average holding pressure (melt Hold Specific Pressure Actual Average
no ActPrsHldSpecAveMax
pressure)
no ActPrsPlstHydMax Plasticization Hydraulic Pressure Actual Maximum
no ActPrsPlstHydAveMax Plasticization Hydraulic Pressure Actual Average
Maximum back pressure (melt Plasticization Specific Pressure Actual Maximum
no ActPrsPlstSpecMax
pressure)
Average back pressure (melt Plasticization Specific Pressure Actual Average
no ActPrsPlstSpecAveMax
pressure)

- 20 -
C15149P
REGISTERD No. 1808-6802102
REGISTERD No. 1808-682302

(3). Vender Specific tokens … Actual Support : SET…SET Command permission


Sup Token
Item Description
port
@ActStrInj INJECTION STROKE ACTUAL
@ActStrMld MOULD OPENING STROKE
@ActStrEje EJECTOR STROKE ACTUAL
@ActVelInj INJECTION SPEED ACTUAL
@ActVelMld MOULDOPENING SPEED
@ActVelEje EJECTOR SPEED ACTUAL
@ActPrsInj INJECTION PRESSURE ACTUAL
@ActPrsCav CAVITY PRESSURE ACTUAL - (Optional)
SET @ActCntRLot DIVIDED LOT COUNTER “0” setting makes counter reset.
SET @ActCntLot LOT COUNTER “0” setting makes counter reset.
@ActDateTime CURRENT DATE TIME pseudo parameter token
@ActTmon01 MONITOR ITEM No.01
@ActTmon02 MONITOR ITEM No.02
: :
@ActTmon32 MONITOR ITEM No.32

(4). Vender Specific tokens …related setting value Support : SET…SET Command permission
Sup Token
Item Description
port
@SetStrInj_S_1[1] INJECTION 2V CHANGE-OVER POSISION
@SetStrInj_S_2[1] INJECTION 3V CHANGE-OVER POSISION
@SetStrInj_S_3[1] INJECTION 4V CHANGE-OVER POSISION
@SetStrInj_S_4[1] INJECTION 5V CHANGE-OVER POSISION
@SetStrInj_S_5[1] INJECTION 6V CHANGE-OVER POSISION
@SetStrInj_S_6[1] INJECTION 7V CHANGE-OVER POSISION
@SetStrInj_S_10[1] V-P SWITCH-OVER POSITION
@SetStrPlst_Sc_0[1] PLAST.2 CHANGE-OVER POSISION
@SetStrPlst_Sc_1[1] PLAST.3 CHANGE-OVER POSISION
@SetStrPlst_Sc_2[1] PLAST.4 CHANGE-OVER POSISION
@SetStrPlst_Sc_3[1] PLAST. COMPLETE POSISION
@SetVelInj_V_0[1] INJECTION 1 VELOCITY
@SetVelInj_V_1[1] INJECTION 2ND VELOCITY
@SetVelInj_V_2[1] INJECTION 3RD VELOCITY
@SetVelInj_V_3[1] INJECTION 4TH VELOCITY
@SetVelInj_V_4[1] INJECTION 5TH VELOCITY
@SetVelInj_V_5[1] INJECTION 6TH VELOCITY
@SetVelInj_V_6[1] INJECTION 7TH VELOCITY
@SetTimInj_P_0[1] FILL PRESSURE. MONITOR
@SetPrsInj_P_1[1] INJECTION 2ND PRESSURE
@SetPrsInj_P_2[1] INJECTION 3RD PRESSURE
@SetPrsInj_P_3[1] INJECTION 4TH PRESSURE
@SetPrsInj_P_4[1] INJECTION 5TH PRESSURE
@SetPrsInj_P_5[1] INJECTION 6TH PRESSURE
@SetPrsInj_P_6[1] INJECTION 7TH PRESSURE
@SetPrsInj_P_7[1] V-P SWITCH-OVER PRESSURE
@SetPrsInj_P_8[1] CAVITY SWITCH-OVER
@SetPrsInj_P_9[1] MAXIMUM PRESSURE
@SetTimInj_T_0[1] 1ST INJECTION PRESSURE TIMER
@SetTimHld_T_1[1] 2ND INJECTION PRESSURE TIMER
@SetTimHld_T_2[1] 3RD INJECTION PRESSURE TIMER
@SetTimHld_T_3[1] 4TH INJECTION PRESSURE TIMER
@SetTimHld_T_4[1] 5TH INJECTION PRESSURE TIMER

- 21 -
C15149P
REGISTERD No. 1808-6802202
REGISTERD No. 1808-682402
@SetTimHld_T_5[1] 6TH INJECTION PRESSURE TIMER
@SetTimHld_T_6[1] 7TH INJECTION PRESSURE TIMER
@SetSpdPlst_Vc_0[1] PLASTICIZING. 1 SPEED
@SetSpdPlst_Vc_1[1] PLASTICIZING. 2 SPEED
@SetSpdPlst_Vc_2[1] PLASTICIZING. 3 SPEED
@SetVelDcmp_Vc_6[1] SUCK BACK SPEED
@SetVelDcmp_Vc_7[1] INJECTION COMPLETE SUCK-BACK SPEED
@SetPrsPlst_Pc_0[1] BACK-PRESSURE 1
@SetPrsPlst_Pc_1[1] BACK-PRESSURE 2
@SetPrsPlst_Pc_2[1] BACK-PRESSURE 3
@SetPrsPlst_Pc_8[1] SRC-II 1ST BACK-PRESSURE
@SetPrsPlst_Pc_9[1] SRC-II 2ND BACK-PRESSURE
@SetPrsPlst_Pc_10[1] SRC-III REVERSE BACK-PRESSURE
@SetTimPlst_Tc_1[1] SRC-I TIMER
@SetTimPlst_Tc_2[1] SRC-II 1ST PRESSURE TIME
@SetTimPlst_Tc_3[1] SRC-II 2ND PRESSURE TIME
@SetCfgInj_Vn[1] INJECTION SPEED STEP No.
@SetCfgInj_Pn[1] INJECTION PRESSURE STEP No.
@SetCfgPlst_Cn[1] PLASTICIZING STEP No.
@SetCfgInj_P1n[1] 1ST PRESS MODE
@SetCfgInj_VPmod[1] V-P SWITCH-OVER MODE
@SetCfgInj_Slpcch[1] CAVITY Sensor MODE
@SetCfgInj_Injmod[1] INJECTION MODE SELECT
@SetCfgPlst_Srcn[1] SRC-II STEP No.
@SetTimInj_Delay[1] INJECTION DELAY TIME
@SetStrClp_So_0 OPENING 2V CHANGE-OVER
@SetStrClp_So_1 OPENING 3V CHANGE-OVER
@SetStrClp_So_2 OPENING 4V CHANGE-OVER
@SetStrClp_So_3 OPENING 5V CHANGE-OVER
@SetStrClp_So_4 OPENED POSITION
@SetStrClp_Sc_0 HP. CHANGE POSN.
@SetStrClp_Sc_1 LOW PRESSURE POSITION
@SetStrClp_Sc_2 3RD SPEED MOULD CLAMP CHANGE POSN.
@SetStrClp_Sc_3 2ND SPEED MOULD CLAMP CHANGE POSN.
@SetVelClp_Vo_0 MOULD OPEN 1 SPEED
@SetVelClp_Vo_1 MOULD OPEN 2 SPEED
@SetVelClp_Vo_2 MOULD OPEN 3 SPEED
@SetVelClp_Vo_3 MOULD OPEN 4 SPEED
@SetVelClp_Vo_4 MOULD OPEN 5 SPEED
@SetVelClp_Vc_0 HIGH-PRESS MOULD CLAMP SPEED
@SetVelClp_Vc_1 LOW-PRESS MOULD CLAMP SPEED
@SetVelClp_Vc_2 3RD SPEED MOULD CLAMP SPEED
@SetVelClp_Vc_3 2ND SPEED MOULD CLAMP SPEED
@SetVelClp_Vc_4 1ST SPEED MOULD CLAMP SPEED
@SetFceClp_Pc_1 LOW MOULD P. - TRQ. MONITOR
@SetCfgClp_NO MOULD OPEN STEP No.
@SetCfgClp_NC MOULD CLOSE STEP No.
@SetStrEje_S_0 EJ ADV.2 CHANGE-OVER POSN.
@SetStrEje_S_1 EJ ADV.3 CHANGE-OVER POSN.
@SetStrEje_S_2 EJ ADV. LIMIT POS.
@SetStrEje_S_3 EJ RE-ADV. POSN.
@SetStrEje_S_4 EJ ZERO-RESET POSITION
@SetVelEje_V_0 EJ ADV. 1 SPEED
@SetVelEje_V_1 EJ ADV. 2 SPEED
@SetVelEje_V_2 EJ ADV. 3 SPEED
@SetVelEje_V_3 EJ RETRACT SPEED
@SetTmsEje_T_0 EJ DELAY TIMER
@SetTmsEje_T_1 EJ STOP TIMER

- 22 -
C15149P
REGISTERD No. 1808-6802302
REGISTERD No. 1808-682502
@SetCntEje_Cnt EJ COUNTER
@SetCfgEje_N EJ ADVANCE STEP No.
SET @SetCntCnt_Rlot DIVIDED LOT NO.
@SetTimCnt_T_2 INTERVAL TIMER
@SetTimCnt_CoolTim COOLING TIMER
SET @SetCslt_yy DELIVERY (Year)
SET @SetCslt_mm DELIVERY (Month)
SET @SetCslt_dd DELIVERY (Day)
SET @SetCslt_hh DELIVERY (hour)
SET @SetCslt_mn DELIVERY (minute)
SET @SetCslt_hh1 WORKING HOUR Start : hour
SET @SetCslt_mn1 WORKING HOUR Start : minute
SET @SetCslt_hh2 WORKING HOUR End : hour
SET @SetCslt_mn2 WORKING HOUR End : minute
SET @SetCslt_wmod_0 OPERATION DAY (SUN)
SET @SetCslt_wmod_1 OPERATION DAY (MON)
SET @SetCslt_wmod_2 OPERATION DAY (TUE)
SET @SetCslt_wmod_3 OPERATION DAY (WED)
SET @SetCslt_wmod_4 OPERATION DAY (THU)
SET @SetCslt_wmod_5 OPERATION DAY (FRI)
SET @SetCslt_wmod_6 OPERATION DAY (SAT)
SET @SetCslt_csmd MONITORING MODE

10. Error Messages


(1) Session Layer Error Codes … These are output to session response files(SESS0001.RSP~).
Code Messages / Description
00000003 Unable to create JOB response file.
00000003 Unable to open JOB response file.
00000007 Unable to open JOB file(%s) ,or not exist.
00000007 JOB command was repeated.
00000007 JOB with the same name and type is already running. (%s)
00000007 JOB with the same JOB response file and type is already running .(%s)
00010001 Memory allocation failure, EXECUTE is impossible.
00010002 Presentation start failure.
(2) Presentation Layer Error Codes … These are output to JOB response file.
Code Messages / Description
00010001 Memory allocation failure, EXECUTE is impossible.
00010002 Presentation start failure.
00000003 Too many active JOBS. (>%d)
00000004 Unable to create/open destination file. (%s)
00000005 Invalid REPORT IF NOT command syntax. Invalid Token(%s).
00000005 Invalid REPORT IF command syntax. Invalid Token(%s).
00000005 Invalid REPORT IF command syntax.
00000006 Unknown REPORT parameter. (%s)
00000007 Too many active REPORTS. (>%d)
00000009 Too many active EVENT ALARMS. (>%d)
00000009 Too many active EVENT CURRENT_ALARMS. (>%d)
00000009 Too many active EVENT CHANGES. (>%d)
00000010 Unknown EVENT parameter. (%s)
00000011 Invalid ABORT command syntax. (%s)
00000012 Invalid UPLOAD command syntax. same destination file.(%s)
00000012 Invalid UPLOAD command syntax. Input data cannot contain any of the following
characters.( /:,;*?<>| ).
00000013 Unable to create/open UPLOAD destination directory/file. There is not a file of (%s).
00000015 Unable to open DOWNLOAD source directory/file. (%s)
00000016 During operation, no DOWNLOAD possible.
00000016 Setting File Manager is OFF, no DOWNLOAD possible.

- 23 -
C15149P
REGISTERD No.No. 1808-6802402
REGISTERD 1808-682602

00000016 DOWNLOAD operation denied. DOWNLOAD file abnormal.


00000016 DOWNLOAD operation denied. Machine type is wrong.
00000017 Invalid GETINFO command syntax. same destination file.(%s)
00000018 Invalid GETID command syntax. same destination file.(%s)
00000020 SET of operation parameter denied. An automatic inside cannot be executed.
00000020 SET of operation parameter denied.
00000020 SET of operation parameter denied. Input data are characters based on ASCII
00000020 SET of operation parameter denied. Input data cannot contain any of the following
characters.( /:,;*?<>| )
00000021 SET value out of range.
00000022 Unknown SET parameter.
00000024 Invalid START parameter syntax. Invalid Token(%s).
00000024 Invalid START parameter syntax.
00000024 Invalid START parameter syntax. There is not START.
00000025 Invalid STOP parameter syntax. Invalid Token(%s).
00000025 Invalid STOP parameter syntax.
00000025 Invalid STOP parameter syntax. There is not STOP.
00000026 Application parameter too long.
00000027 Invalid numeric format.(%s)
00000028 Invalid comparison operator.(%s)
00000029 Invalid time format.
00000031 End of command expected.(%d)
00000032 JOB command was repeated.
00000033 REPORT with the same name and type is already running. (%s)
00000034 EVENT with the same name and type is already running. (%s)
00000035 DOWNLOAD is already running.
00000036 The specified command to abort, (%s) is not active.
00000036 The specified REPORT command to abort, (%s) is not active.
00000036 The specified EVENT command to abort, (%s) is not active.
00000037 Error during command processing.(%d)
00000037 Setting File Manager is OFF, no UPLOAD possible.
00010001 Memory allocation failure, REPORT execution is impossible.
00010001 Memory allocation failure, EVENT execution is impossible.
00010001 Memory allocation failure, GETINFO execution are impossible
00010001 Memory allocation failure, GETID execution is impossible.
00010001 Memory allocation failure, ABORT execution is impossible.
00010001 Memory allocation failure, UPLOAD execution is impossible.
00010001 Memory allocation failure, DOWNLOAD execution is impossible.
00010002 REPORTS Application start failure.
00010002 EVENT Application start failure.
00010002 GETINFO Application start failure.
00010002 GETID Application start failure.
00010002 ABORT Application start failure.
00010002 UPLOAD Application start failure.
00010002 DOWNLOAD Application start failure.

- 24 -
C15149P
REGISTERD No.
REGISTERD No. 1808-682702
1808-6802502
11. Application Examples
SESS0001.REQ SESS0001.RSP
REQ_0001 CONNECT; REQ_0001
REQ_0002 EXECUTE "\\NTWK71\Euromap63\data\PD.JOB"; PROCESSED;

PD.JOB pd.log
JOB pd RESPONSE "\\NTWK71\Euromap63\data\pd.log"; COMMAND 1 PROCESSED "JOB command" 20140424 09:14:20
REPORT spc COMMAND 2 PROCESSED "REPORT command" 20140424 09:35:29
APPEND "\\NTWK71\Euromap63\data\spc.dat"
START IMMEDIATE
STOP NEVER
CYCLIC TIME 00:10:00 // sample data every 10 minutes spc.dat The monitor data output
SAMPLES 10 DATE,TIME,COUNT,ActCntCyc,ActTmpBrlZn[1,1],ActStrCsh[1],ActStrXfr[1],ActStrPlst[1]
SESSIONS 30 20140424,09:14:19,1,8879, 0.0, 2.33, 29.66, 32.00
PARAMETERS 20140424,09:14:28,2,8880, 0.0, 2.33, 29.67, 32.00
DATE, 20140424,09:14:36,3,8881, 0.0, 2.32, 29.67, 32.00
TIME, 20140424,09:14:45,4,8882, 0.0, 2.33, 29.68, 32.00
COUNT, 20140424,09:14:53,5,8883, 0.0, 2.34, 29.67, 32.00
ActCntCyc, 20140424,09:15:02,6,8884, 0.0, 2.33, 29.66, 32.00
ActTmpBrlZn[1,1], 20140424,09:15:10,7,8885, 0.0, 2.33, 29.67, 32.00
ActStrCsh[1], 20140424,09:15:19,8,8886, 0.0, 2.32, 29.67, 32.00
ActStrXfr[1], 20140424,09:15:27,9,8887, 0.0, 2.33, 29.68, 32.00
ActStrPlst[1]; 20140424,09:15:36,10,8888, 0.0, 2.34, 29.67, 32.00
20140424,09:24:16,11,8949, 0.0, 2.33, 29.66, 32.00
20140424,09:24:24,12,8950, 0.0, 2.33, 29.67, 32.00
20140424,09:24:33,13,8951, 0.0, 2.32, 29.67, 32.00
20140424,09:24:41,14,8952, 0.0, 2.33, 29.68, 32.00
20140424,09:24:50,15,8953, 0.0, 2.34, 29.67, 32.00
20140424,09:24:59,16,8954, 0.0, 2.33, 29.66, 32.00
20140424,09:25:07,17,8955, 0.0, 2.33, 29.67, 32.00
20140424,09:25:16,18,8956, 0.0, 2.32, 29.67, 32.00
20140424,09:25:24,19,8957, 0.0, 2.33, 29.68, 32.00
20140424,09:25:33,20,8958, 0.0, 2.34, 29.67, 32.00
20140424,09:34:13,21,9019, 0.0, 2.33, 29.66, 32.00
20140424,09:34:21,22,9020, 0.0, 2.33, 29.67, 32.00
20140424,09:34:30,23,9021, 0.0, 2.32, 29.67, 32.00

SESS0002.REQ SESS0002.RSP
REQ_0001 CONNECT REQ_0001 PROCESSED;
REQ_0002 EXECUTE "\\192.168.4.147\Euromap63\data\ALR.JOB"; REQ_0002 PROCESSED;

ALR.JOB

JOB alr RESPONSE "\\NTWK71\Euromap63\data\alr.log";


EVENT myEventAlarms ALARMS APPEND "\\NTWK71\Euromap63\data\alr.dat" SESS0002.RSP
START TIME>= 08:40:00 COMMAND 1 PROCESSED "JOB command" 20140425 08:33:40
STOP TIME>= 09:10:00 ; COMMAND 2 PROCESSED "EVENT command" 20140425 09:10:00

alr.dat The alarm data output


20140425,08:40:06,1,1,966,"* Over-pack ( cushion ) * (966)"
20140425,08:40:11,2,0,966,"* Over-pack ( cushion ) * (966)"
20140425,09:08:13,3,1,195,"Low pressure mould closing alarm.(dp= 3.02,torque= 1) (195)"
20140425,09:08:14,4,1,452,"Mould Now Opening. (ALARM MODE) (452)"
20140425,09:08:44,5,0,452,"Mould Now Opening. (ALARM MODE) (452)"
20140425,09:08:47,6,0,1561,"** CAUTION ** Please make one-cycle time 0 second or more. (1561)"

- 25 -
C15149P
REGISTERD No.
REGISTERD No. 1808-6802602
1808-682803
12. Ethernet connection
Ethernet specifications: 100BASE-TX
Shape of connector: RJ45
Ethernet cable: Category 5 or higher

Connect the Ethernet cable to MAIN BOARD CMA26 in the control panel of IMM.

MAIN BOARD

CMA26

13. Remarks
(1) These specifications are communication control specifications based on EUROMAP63 Data Exchange
Interface ,Version 1.05a. Items not described in this document shall be discussed separately.
(2) Some tokens described in EURPMAP63 cannot be handled by these specifications. ( See 6-(2) 9-(2) .)
(3) After you complete the setting of this communication connection, you need to turn the machine power
OFF and ON, so that your setting becomes effective.
(4) You cannot change molding conditions using SET command from the host computer.
(5) In setting of character strings of SET command, you can use ASCII characters only.
You cannot use symbols, such as /:,;*?<>|.
(6) Do not change uploaded condition files, or the files cannot be downloaded anymore.
(7) When you refer to the data file of REPORT/EVENT, use the system with READ open.
Do not lock the file. When data file writing is made on the molding machine side, WRITE opening
is made every line. If WRITE opening is failed, retry is made. In the case that retry is failed 20 times
(about 20 seconds), REPORT/EVENT is stopped in error.
(8) To monitor the status of the IMM, request the job only once as described in the specification
eu63.pdf 3.14.3. Since EUROMAP63 is based on the premise that JOB resides, a thread is
created / started every time a JOB is issued. Requesting the same JOB repeatedly (eg every
10 seconds) may cause memory shortage.
JOB file (STATUS.JOB)
JOB machstat RESPONSE "\\server1\vol1\mach_10\status.log";
REPORT status REWRITE "\\server1\vol1\mach_10\prot\status.dat" //cyclic overwriting
START IMMEDIATE // start the report immediate
STOP NEVER // no stop condition
CYCLIC TIME 00:00:10 // record parameters every 10 sec
PARAMETERS
ActStsMach; // Actual Machine Status.

- 26 -
C15149P
REGISTERD No. 1808-682902
REGISTERD No. 1808-6802702
14. Connection check
The [Communication Setting Window] displays the communication confirmation steps and communication
status from the start of host connection.
In case of connection trouble ("NG" is displayed), check the status display and how to deal with it.

Connection procedure from IMM to host Progress Result


1. link-up check "NG.e"
2. ping check "ping" "NG.p"
3-a. Connection check "\\host\share folder" (File sharing: Mount by host / user / password) "try" "NG.m"
3-b1. Connection check "\\host\share folder" (ftp: Open by host name) "try" "NG.h"
3-b2. Connection check "\\host\share folder" (ftp: Recognize by user / password) "try" "NG.u"

Connection procedure to SESSION folder Progress Result


4-a. SCheck if there is Session folder (ftp: Check by cd command (change directory)) "try" "NG.d"
4-b. Check if there is Session folder (File sharing: Check by opendir()) "try" "NG.d"
5. Check read/write permission of sesson foldwer (Check by write/delete PermissionTest.txt) "NG.w"

Sequence in case of connection failure Time counter


6. Wait for approx. 100 seconds with time counter display "(99)"~"(0)"
7. Repeat the connection from 1. link-up check

Display of status of connection failure


Connection status "NG.e" "NG.p" "NG.m" "NG.h" "NG.u" "NG.d" "NG.w"
host1 File sharing ○ ○ ○ --- --- --- ---
host2 File sharing ○ ○ ○ --- --- --- ---
host3 File sharing ○ ○ ○ --- --- --- ---
host1 ftp ○ ○ --- ○ ○ --- ---
host2 ftp ○ ○ --- ○ ○ --- ---
host3 ftp ○ ○ --- ○ ○ --- ---
IoT-GW ftp (fixed) ○ ○ --- ○ ○ --- ---

SESSION pass File sharing --- --- --- --- --- ○ ○


SESSION pass ftp --- --- --- ○ ○ ○ ○
SESSION-GW ftp (fixed) --- --- --- ○ ○ ○ ○

Description of connection status How to respond


" " No IP, host name, share name
"OK" Successful
"NG.e" link down No connection through ethernet cable (--> Check a wiring)
"ping" Wait for the response of ping
"NG.p" ping error No host found (--> Check connection network, host setup)
"try" Wait for connection
Permission denied due to host name (IP address), user, password
"NG.m" mount error ①Check host, user, password, ②Check, Enable of "Windows10 SMB1.0 Server"
(③Check updated of "SD card"…SYSTEM700)
"NG.h" host open error No host (IP address) found (--> Check host name)
"NG.u" user, password error Permission denied due to user, password (--> Check user, password)
"NG.d" dir error No host directory found (--> Check directory)
"NG.w" write error Not writing available to SESSION pass (--> Check write permission)
"(99)"-"(0)" Wait for re-connection Display a time counter
"NG.D" Internal dir error Failure of internal opendir()
"NG.1"-"NG.7" (ftp connection error) (Error code 1-7 when using ftp)

- 27 -
C15149P
REGISTERD No. 1808-6802802
REGISTERD No. 1811-125101

Description of internal error number (FTP only) (Internal error)


"NG.1" (Internal connection error) Link is Down
ftp error
timeout detection
No file received by ftp get --> Re-try "File not found"
No file found "File not found"
No file_name "Invalid command"
fopen( outfile, "r" ); file open error
"NG.2" (Internal connection error) (no directory), no directory due to wrong folder direction "directory not found"
(no directory), no directory due to wrong folder direction "Failed to change directory."
(no directory), no directory due to wrong folder direction "CWD failed"
No directory due to wrong folder direction "No such file or directory"
(open error), wrong host name or no power/no network "Not connected"
"NG.3" (Internal connection error)
connection on host
"NG.4" (Internal connection error) (user error), wrong user/password "Login incorrect"
(user error), wrong user/password "Login or password incorrect"
"NG.5" (Internal connection error) (no directory)
"NG.6" (Internal connection error) No read/write authorization "Permission denied"
"NG.7" (Internal connection error) マ Multibyte file name "Invalid command"

When "NG.m" is displayed on the Windows 10 host PC


SMB1.0 Server may be disabled. (Disabled by Windows update)
In this case, enable SMB1.0 Server.
From [Control Panel] [Programs and Features] [Turn Windows features on or off]