STRUCTURAL ANALYSIS

AND
DESIGN COMPUTATION

PROJECT: Proposed 3-Storey Residential w/ Roof Deck


LOCATION: LAKEVIEW HOMES, MUNTINLUPA
OWNER: Ma. Remia C. Catoto
STRUCTURAL MODEL
DESIGN METHODOLOGY:
ULTIMATE STRENGTH DESIGN
DESIGN LOADS:
Dead Loads
1. Selfweight

Concrete Unit weight = 24 kN/m3

2. Member Load

150 mm CHB = 2.63 + 0.24 + 0.24 = 3.11 kN/m per meter height
100 mm CHB = 2.50 + 0.24 + 0.24 = 2.98 kN/m per meter height
3. Floor Load

Materials Floor Load Roof Load


(kpa) (kpa)
125 mm Steel 9.66 -
Deck
Floor Finish 1.10 -
Ceiling 0.348 0.348
MEP 0.10 0.10
Interior 1.00
Partition
Roof framing - 0.41
Corrugated - 0.10
roofing sheet

4. Live Load

Use or Uniform
Occupancy Load

Category Description kPa

Residentia Basic Floor Area 1.9


l
Multi-Purpose Hall / Lobbies 4.8
Office 2.9

Storage 6
Conference Room 2.9 kPa
DESIGN CRITERIA

Seismic Design Parameters

Seismic Zone Zone 4; Z=0.40


Seismic Source Type Type B
Importance Factor 1.0
Soil Type SD
Seismic Coefficient, Cv .572
Near-source factor, Nv 1.3
Seismic Coefficient, Ca 1.024
1.6
Near-source factor, Na
R Ω Cd
R.C Special Moment Resisting Frame 8.5 3.0 5.5

ALLOWABLE SOIL BEARING PRESSURE = 140 KPA (Assumed)

NOTE:
IN CASE SOIL BEARING PRESSURE IS DIFFERENT FROM THE ASSUMED VALUE,
FOUNDATION SHALL BE COMPUTED FOR THAT PARTICULAR VALUE
Wind Design Parameters

Basic Wind Speed, V 270 kph


Exposure Type Type B
Wind Directionality Factor, KD 0.85
Topographic Factor, KZT 1.0
Gust Effect Factor, G 0.85
Enclosure Classification  Partially Enclosed
Internal Pressure Coefficient  ± 0.55

STAAD INPUT
STAAD Output
MANUAL CHECKING:

You might also like