Compact Waste Water Treatment

MBR /MBBR Technology


Minimal

Operation and Maintenance
1 Costs and use of Chemicals 2
3OXJDQG3OD\V\VWHP 


Recycle
 and Reuse water for Save Water, Energy, Money and
3 Conserve the Environment 4
Irrigation and Recreation


SUSTAINABLE WATER SOLUTIONS


WATER ENGINEERING – MBR /MBBR STP Process Flow Scheme

Water Engineering Packaged Water MBBR Treatment Sy  Raw Wastewater Feed Pumps
stems are state of the art yet affordable plants which are
capable of giving excellent quality Treated sewage on  Air Blowers and Coarse Bubble Diffusers for
small footprint Equalization/Sludge Tank (Optional)

The System is a Combination of the Fixed Film and  Electromagnetic Flow Meters at Inlet of STP

Activated Sludge Process, Activate Sludge has process


 Manual Coarse Screen, Bar Type, 10 mm
stability and provides a high degree of treatment and
Fixed Film Processes are inherently stable and resistant  Aeration Tanks with Coarse Bubble Diffusers and
to organic and hydraulic shock loadings. Air Piping

By incorporating Activated Sludge Recirculation (RAS)  Bio Media inside Aeration Tank
higher high quality Biomass can be maintained. This
makes the Process more stable, more responsive to load  Air Blowers for Aeration Tanks
fluctuations and provides better oxygen diffusion, mixing
 Sludge Recirculation/Waste Pumps
and energy efficiency then conventional MBBR.

Design Basis  Motorized Valves for Sludge Wasting

PH 7.0-8.5  Settling Tank with Tube Deck Media

BOD (mg/l) 300-350 mg/l


 Sodium Hypochlorite Disinfection System
COD (mg/l) 400-600 mg/l
 Manual/Automatic Multi Media Filter
Suspended solids (mg/l) 300-400 mg/l

Ammonical Nitrogen 40-50 mg/l  Filter Feed Pumps

Treated Effluent Quality


 Backwash Pumps

BOD < 15 mg/l


 Electrical Control Panel, Form 2
COD < 100 mg/l
 Internal and external Interconnecting Piping and
Suspended solids < 15 mg/l
accessories

SUSTAINABLE WATER SOLUTIONS


Air
PROCESS FLOW SCHEME OF STP Blowers

Mancial MBBR Tank Recirculation


Wastewater Storage
Caorse Aeration + Nitrification + Settling /Waste
Equalization Feed Tank
Screen (Compartments) Sludge Pump
Tank Pumps

Chlorine
Contact Tank

Sewage
Chlorine
Collection Backwash Dosing
Tank Pumps P

Treated Multi Media Filter Feed


Sewage Tank Filters Pumps

Salient Features

 Factory made plug and play system with small


footprint.

 MLSS Concentrations of 2000-3000 mg/l which


increases SRT resulting in better biology and
performance.

 Reduction in sludge production and less sludge


needs to be wasted compared to Conventional
MBBR.

 Safe HRT enabling stable and sustainable Biology


and better Aeration and Nitrification.

 Using very conservative surface area loading rates


for the Biomedia thereby ensuring design for peak
flows.

 Positive Displacement Blowers for Aeration


instead of Side Channel Blower which are better in
quality and long lasting.

 Coarse Bubble Differs for Aeration specially


designed to ensure the swirling action to keep Bio
Media in suspension.

 State of the art Bio Media from GEA – Germany


which creates the perfect environment for bacteria

SUSTAINABLE WATER SOLUTIONS


Model *Capacity Population Inlet Outlet Tank Dimensions Multi Media Filter
No. (m3/d) (persons) (BOD/TSS) (BOD/TSS) Diameter

WMBR 100 100 500 300/400 15/15 4.5 m * 2.5 m * 3.5 m 30 Inch

WMBR 150 150 750 300/400 15/15 6.3 m * 2.5 m * 3.5 m 36 Inch

WMBR 200 200 1000 300/400 15/15 8.2 m * 2.5 m * 3.5 m 42 Inch

WMBR 250 250 1250 300/400 15/15 10.1 m * 2.5 m * 3.5 m 48 Inch

WMBR 300 300 1500 300/400 15/15 12.0 m * 2.5 m * 3.5 m 48 Inch

WMBR 350 350 1750 300/400 15/15 12.0 m * 3.0 m * 3.5 m 63 Inch

*Calculations are based on discharge of 200 liters of Wastewater per person per day.
If bigger capacity is required than the standard modules can be added in parallel

A ISO 9001:2008 Company


STP-HS-0.5B
Wastewater Treatment Systems with
Nutrient(N,P)Removal
Hydraulic loading:500L/day
Inlet pipe Access cover Flow rate adjustment Influent
1st Anaerobic
Clarification chamber chamber/Primary
settlement
Disinfection

Reccirculation
2nd Anaerobic

Mixing
Tank(DCPD) chamber
Flow Rate
Adjustment
Area

Backwash
Outlet pipe Flow rate
adjustment device A
su ir

Flow rate
pp

Control
Electrodes for P ly

Aerobic chamber
Aeration chamber
removal (Optional)
Bio-film filtration
Air
chamber
blow er

Phosphorus Backwash
removal area
Bio-film filtration
chamber Clarification Washing
chamber

Disinfection
area
Aeration chamber
Effluent
1st Anaerobic 2nd Anaerobic chamber
chamber/Primary settlement

Advanced
优点 Performance Nitrogen removal
The systems are designed for installations in In anaerobic chambers, nitrogen-removing mic-
environmentally sensitive area and the effluent roorganisms grow on the surface of filter media.
can meet: The microorganisms convert nitrates in the re-
·COD ≤60mg/L circulated water coming from the aerobic chamber
·SS ≤20mg/L to nitrogen gas which returns to the atmosphere
·TN ≤15mg/L
without causing any harm.
·TP ≤1mg/L
·NH 3 -N ≤ 8mg/L
Phosphorus removal
Through electrolytic process of electrodes in the
wastewater, phosphate is generated and precipitated,
Automatic backwash thus removing phosphorus. The water washes the
Automatic backwash controlled by timer ensures: surface of electrodes, further stabilizing P removal.
·stable and highly efficient treatment performance
·automatically controlling the thickness of bio-film Flow rate adjustment
on the filter media
Combined with airlift pump and overflow weir, flow
·better nitrogen and SS removal
rate adjustment device easily controls the volume of
·the filter media not clogging both effluent water and re-circulated water.
Details of the systems
Effective volume m3 Dimension mm Inlet invert Outlet invert Weight Air blowers Diameter
Total
Model 1st anaerobic 3 depth to base
2nd anaerobic Aerobic Clarification volume m (Kg) Power Airflow of access
chamber/Pri- length width height (mm) (mm)
mary settlement
chamber chambe chamber W(50Hz) L/min cover (mm)

DSP-SH-05B 0.334 0.371 0.284 0.112 1.437 1672 972 1477 360 370 250 30 40 600

Warranty
15 years for tank, 2 years for electrical components

Structure diagram

5m3/day Package MBBR plant