Company : ADVANTECH Date of repair: 2018/2/13 RMA No: M18FE01 Completion Date: 2018/2/13 Product: DC monitor Time: 2 (HR) MODEL: SLF-MN550-DC Failure Symptom: S/N : ACT1G05T054 1. Remote control not working 2. When switch on with remort LCD, atumatic switch off
Maintenance process: 1. Test Input source
2. Test Remote control 3. Replacement LVDS cable 4. Test all function
ITEM Part ITEM Quantity Remarks
1 IR receiver 1 IR receiver fail
1. Use remote control the LCD is fail.
2. The IR receiver inside the LCD TV has a sensor sensibility issue, it can only take very limited distance signal. 3. Replacement IR receiver board. 4. Test the input source/remont control/button/volume, all function test ok. 5. When the monitor power off after the open, it must wait 15~25 seconds