RMA Test Report: TEL:+886-2-25595216 FAX:+886-2-25595218

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ACT POWER Taiwan Ltd.

4F-3,No35,Gangu St., Datong Dist., Taipei City 10343,Taiwan,R,O,C


TEL:+886-2-25595216 FAX:+886-2-25595218

RMA Test report


Company : ADVANTECH Date of repair: 2018/2/13
RMA No: M18FE01 Completion Date: 2018/2/13
Product: DC monitor Time: 2 (HR)
MODEL: SLF-MN550-DC Failure Symptom:
S/N : ACT1G05T054 1. Remote control not working
2. When switch on with remort LCD,
atumatic switch off

Maintenance process: 1. Test Input source


2. Test Remote control
3. Replacement LVDS cable
4. Test all function

ITEM Part ITEM Quantity Remarks


1 IR receiver 1 IR receiver fail

1. Use remote control the LCD is fail.


2. The IR receiver inside the LCD TV has a sensor sensibility issue, it can only take very limited
distance signal.
3. Replacement IR receiver board.
4. Test the input source/remont control/button/volume, all function test ok.
5. When the monitor power off after the open, it must wait 15~25 seconds

Description

Supervisor: Product manager Mark Engineer: Mark