Professional Documents
Culture Documents
Brosure Data Sheet of 22kva Perkins 404A-22 With Stamford PI144D
Brosure Data Sheet of 22kva Perkins 404A-22 With Stamford PI144D
RPM1500 50Hz
R atin g R an g e
Stan d b y (M EC C ):
Prime: 1612.
KW65 kW
Prim e(M EC C ): 11.5 kw
11.5kw
20 KVA
Stan d b y (Levo y So m er):
Standby: 1817.
KW6 kw
17.6kw
Prim e(Levo y So m er): 2216KVA
kw
16kw
ASSEMBLY
※ The engine and alternator are coupled together by means of a SAE flange. A full torsional analysis will be carried
Out to ensure vibration to be reduced to the minimum.
※ Anti-vibration pads are affixed between both engine and alternator; and the base frame. This will ensure better
vibration isolation of the rotating assemblies and enabling the machine to be placed on uneven terrain without
any detrimental effects.
※ For improved durability and corrosion resistance, all metallic fabrication surfaces of the canopy will have to be
treated for coating by grit blast cleaning. They are then covered by special three layers painting system which will
provide an excellent corrosion resistant surface.
※ Controllers are available for all types of applications. Using functional grouping, the control systems can be
specified into key start controller model, automatic start control model and PCRC three remote control systems.
See controller features inside.
WARRANTY
※ Jensonn provides warranty obligation for all its products. All products are out through rigorous testing proc
edures to ensure optimal performance. Load tests are all ran with various load factors and protective devic
es and control functions are all stimulated and checked before being despatched.
※ Engine and Alternator are all on standard principle warranty of 12 months or 18 months from shipment, wh
ichever comes first.
※ All engines, alternator and components are all backed by international warranty from respective suppliers to
allow
hassle free support.
Prime power (P)
These ratings are applicable for supplying continuous electrical power (at variable load). There is no limitation to
the annual hours of operation and this model can supply 10% over-load power for 1 hour in12 hours.
Standby power(S)
Standby power is defined as the maximum power available, under the agreed operating conditions, for which the
generating set is capable of delivering for up to 500h of operation per year.
DIESEL ENGINE
Altitude: Derating is at 2.0% per 300m for elevation above 1000m. For attitude more than 2450m, please contact us or our
dealer for assistance.
Temperature: Derating is at 6.0% per 11 degree for temperature above 40 degree.
ALTERNATOR
NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor
for more detailed information.
®
ELECTRO-MAGNETIC COMPATIBILITY
AUTO START AND AUTO MAINS FAILURE BS EN 61000-6-2
EMC Generic Immunity Standard for
CONTROL MODULES the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES
ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
The DSE4610 Auto Start Control Monitoring engine speed, oil Through USB Communication both including Electrical Business Equipment
Module and the DSE4620 Auto pressure, coolant temperature, modules can be easily configured TEMPERATURE
Mains (Utility) Failure Control frequency, voltage, current, power using the DSE Configuration Suite BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
Module are suitable for a wide and fuel level, the modules will give PC Software or can be fully BS EN 60068-2-2
variety of single gen-set comprehensive engine and configured through the module's Bb/Be Dry Heat +70 oC
applications. alternator protection. This will be front panel editor.
VIBRATION
indicated on the largest back-lit BS EN 60068-2-6
Whilst maintaining functions LCD icon display in its class via an All DSE products are supported by Ten sweeps in each of three
major axes
included within higher end array of warning, electrical trip and the DSE global technical support 5 Hz to 8 Hz @ +/-7.5 mm,
controllers, such as generator or shutdown alarms. team which gives our customers 8 Hz to 500 Hz @ 2 gn
load power monitoring, the and end users access to 24 hour
HUMIDITY
DSE46xx range of especially Alternator sensing, engine support system help and advice. BS EN 60068-2-30
compact controllers provide the for diesel, gas and petrol engines Db Damp Heat Cyclic 20/55 oC
@ 95% RH 48 Hours
user with the ultimate size to all in one variant. With a number of BS EN 60068-2-78
feature ratio. flexible inputs, outputs and Cab Damp Heat Static 40 oC
protections, the modules can be @ 93% RH 48 Hours
easily adapted to suit a wide range SHOCK
of applications including lighting BS EN 60068-2-27
Three shocks in each of three major axes
towers with the added option for 15 gn in 11 mS
staged loading outputs.
DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the optional sealing gasket.
4 4 3
DSE4610/20
7
OTHER
MAINS (UTILITY) DC OUTPUT GENERATOR / DC OUTPUT GENERATOR CHARGE FUEL AND MAGNETIC PICK-UP
SENSING 1 OF 4 4620 LOAD CURRENT 1 OF 4 4620 SENSING ALTERNATOR CRANK OUTPUTS
(DSE4620) 1 OF 2 4610 1 OF 2 4610
VOLTS VOLTS
D+ +
+ + W/L
ISSUE 1
®
DSE4610/20 SPECIFICATION
DC SUPPLY
AUTO START AND AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CONTROL MODULES CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
FEATURES supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.
FREQUENCY RANGE
3.5 Hz to 75 Hz
OUTPUTS
OUTPUT A (FUEL)
10 A short term, 5 A continuous,
at supply voltage
OUTPUT B (START)
10 A short term, 5 A continuous,
at supply voltage