3.890244 1840.

5
1.65 3301.1
2.07963
3.709302 3664.6 3.15 6.3
4788.6 3.189855
2.808562
4 8
31.924 3.797619
4.092821

1365.8
2683.5
1.628679
2.45 4.9
17.89
3.252727
soil bearing capacity 150 kN/m2
Distance from c.g to c.g : 3.2 m
P1(working) 1822.26 Kn P1(ULT) 2733.39 Kn
P2(working) 1713.36 Kn P2(ULT) 2570.04 Kn
R(working) 3535.62 Kn R(ultimate) 5303.43 Kn
column dimensions
a1 0.8 m
b1 0.4 m
a2 0.67 m
b2 0.33 m
distance from corner of column2 to the corner of the footing (.5 :1) m 0.7 m
P.C footing thickness 0.4 m
concrete Fcu = 25 N/mm2
steel Fy = 360 N/mm3
Resultant of 2 loads is at : 1.649281 m from column 2
R.C footing length 5.4 m
P.C footing length 6.2 m
P.C footing width 3.85 m
R.C footing width 3.05 m
Actual normal stress on R.C footing(ult) Fact = 322.005464 KN/m2
Actual uniform load on R.C footing(ult) Wu.l = 982.116667 KN/m
Point of zero shear (Xo) = 2.783162 m
M1 287.3796 kN.m
M2 109.3563 kN.m
M3 -619.3345 kN.m
M4 144.0669 kN.m
M5 323.9815 kN.m
Mmax 323.9815 kN.m
d 325.9194 mm
t R.C 400 mm
Check depth in transverse direction :
Hidden beam 1: Hidden beam 2:
width of beam (L1) = 1.46 m width of beam (L2) = 1.33 m
F1act = 613.8311 Kn/m F2act = 633.560952 Kn/m
M1act = 538.8286 kN.m M2act = 585.917168 kN.m
Mmax new = 585.9172 kN.m
d new = 630 m #DIV/0!
t R.C 700 mm
Recheck depth in transverse direction :
Hidden beam 1: Hidden beam 2:
width of beam (L1) = 2.06 m width of beam (L2) = 1.93 m
F1act = 435.0454 Kn/m F2act = 436.598998 Kn/m
M1act = 381.8883 kN.m M2act = 403.766753 kN.m
Check shear at long direcion :
Q1 = 751.3193 Kn
Q2 = 1196.377 Kn
Q3 = 1224.54 Kn
Q4 = 687.4817 Kn
Qmax = 1224.54 Kn
Qcritical = 605.8067 Kn
Actual shear stress :
qu = 0.315278 kN/m2
Allowable shear stress :
qsh = 0.653197 N/mm2
qu must be less than qsh
Check Punching Shear :
Column1:- Column2:-
Punching force Punching force
Q1p = 2259.108 Kn Q2p = 2168.177 Kn
A1p = 4.92 m2 A2p = 4.52 m2
Actual punching shear stress : Actual punching shear stress :
q1pu = 0.459168 N/mm2 q2pu = 0.479685 N/mm2
qpu max= 0.479685 N/mm2
Allowable punching shear strength
qpcu = 1.290065 N/mm2
qpu max must be less than qpcu
Reinforcement of the footing :-
Longitudinal diection:
Sec1
C1 = #NUM! J (from table) = 0.826
As = -3204.272 mm2
As(mm2/m) = -1050.581 mm2/m
Check As min :
As min = 945 mm2
or = 565.2 mm2
As req = 945 mm2
dia of reinforcemen: 16 mm Number of bars = 5
Short direction :-
Hidden beam 1:
C1 = 5.097326 J (from table) = 0.826
As = 2038.512 mm2/m
As req = 2038.512 mm2/m
dia of reinforcemen: 16 mm Number of bars = 11 must less than 12
Hidden beam 2:
C1 = 4.957301 J (from table) = 0.826
As = 2155.299 mm2/m
As req = 2155.299 mm2/m
dia of reinforcemen: 16 mm Number of bars = 11
Sec2
C1 = 9.664966 J (from table) = 0.826
As = 1729.407 mm2
As(mm2/m) = 567.0186 mm2/m
As req = 945 mm2
dia of reinforcemen: 16 mm Number of bars = 5