Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

CASA MAYA SDN. BHD.(985422-X)(GST ID NO.

: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

PERSATUAN ALUMNI TAIWAN, SELANGOR DAN WILAYAH PERSEKUTUAN


152-3F, Persiaran Raja Muda Musa,
41100 Klang,
Selangor ,
Malaysia
(O) 017-686 8037
(F) 03-3168 2952
Email: bc.ang@surimaju.com

Attention : Mr. Ang Boon Chin

Dear Sir/Madam,
PRPOSED TO SUPPLY & INSTALL ONE (1) SETS OF 8 PERSON PASSENGER LIFT
- PASSENGER LIFT QUOTATION
Further the discussion between you and the undersigned, and we are please to write and confirm our final
quotation as below:-

Item Description Unit Rate Qty Total Amount


A. P8-CO60-6S
Gearless Motor
(630kg speed 60mpm and 6stops) RM 108,150.00 1 set RM 108,150.00
Motor Room Type
B. Labor & Material to dismantle existing RM 6,000.00 1 lot RM 6,000.00
equipment and cart away the material
Total : RM 114,150.00
6% GST : RM 6,849.00
Total Amount: RM 120,990.00
Standard finishes
i. Finishes are Stainless Steel Hairline for 3 side Car wall
ii. Car Door is Stainless Steel Hairline Frame
iii. Landing Door are Stainless Steel Hairline c/w Hairline Narrow Frame
iv. Flooring Vinyl Tiles Provided
vi. Ceiling LF-01(Standard)

Material Excluded
1. Lift shaft and pit civil and structural works
2. Lift motor room lift switch board and Exhaust fan
3. Lift pit light and 13a/s/s/o
4. Structural Hacking & Touch Up Work
5. Separator Beam in hoistway (if required)
6. Incoming Power Supply Cable to Switchboard

1. Delivery of Equipment to Site


The equipment shall be delivered to site within Eight (8) weeks from date of receipt of the approved shop
drawings and down payment
2. Installation
The installation of the equipment at site shall require Three (3) weeks counting from the date of handing
over to us of the completed lift hoistway and machine room for our unimpeded work or arrival of
equipment to site whichever is later.

Authorise Distributor:
CASA MAYA SDN. BHD.(985422-X)(GST ID NO.: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

3. Testing and Commissioning


The testing and commissioning of the installation shall require a period of Two(2)weeks of normal
unimpeded working hours from the date of availability of AC 415V 3 phase 50Hz permanent electricity
power supply of sufficient capacity made available to the lift machine room by others.
4. Defect and Liability Period
We offer Twelve (12) months warranty from the date of approval by Building Certificate of Fitness or
Eighteen (18) months from the equipment is arrived whichever come first.

5. Free Maintenance Service


Free monthly maintenance service is provided during the Twelve (12) months free maintenance and
guarantee period as mentioned above. During this period, we shall also provide twenty –four (24) hours
breakdown service call.
TERMS OF PAYMENT (14 DAYS)
Our offer is based on the following payment terms:
On Each Lift Ordered
1. 30% of Contract Sum to be paid as non-refundable down payment
2. 50% of Contract Sum to be paid upon equipment delivery at site
3. 10% of Contract Sum to be paid upon completion of mechanical installation
4. 5% of Contract Sum to be paid upon completion of lift’s testing and commissioning
5. 5% of Contract Sum to be paid before lifts handing over for usage

TAX AND/OR DUTY FLUCTUATION


Our offer is inclusive of the five percent (5%) import duty currently levied by the Malaysia Government on the
imported lifts / escalator equipment. On the event of any further escalation of import duty or increasing GST rate
imposed, this shall be for the buyers account. If partial delivery is required, all taxes and duties payable at the time
of import for partial shipment shall be for your account.

Maintenance Service 1st ~ 3rd Year


1. General Service and Maintenance is RM 450.00 for every month.
2. Fully Comprehensive Service and Maintenance is RM 650.00 for every month.

VALIDITY
Our offer is valid for acceptance for a period of thirty (30) days counting from the date of this letter. There after it
is subjected to our reconfirmation.

We trust that you will find our offer competitive and look forward to the opportunity of discussing our offer in
greater details with you.

Thank You.

Yours faithfully, We sign and chop confirm on behalf of


CASA MAYA SDN.BHD.

Cheong MW
______________ _ ___ ________
CHEONG.MW Name: _________
GENERAL MANAGER Position: _________
Date: ________

Authorise Distributor:
CASA MAYA SDN. BHD.(985422-X)(GST ID NO.: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

LF-01
Ceiling : Hairline Stainless Steel frame with mirror
stainless steel pattern in center

Lift Car Interior


(Stainless Steel Hairline)

DB 06 Vinyl Tile

Car Operation Panel Board


Button EB960 (COP 1030)
Hall Call Station
(EH1030)

Authorise Distributor:
CASA MAYA SDN. BHD.(985422-X)(GST ID NO.: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

SPECIFICATION

TYPE Lift No. P1

USAGE PASSENGER LIFT

P8-CO60-6/6STOPS
MODEL

CONTRY OF ORIGINES AUSTRIAL/CHINA

FACTORY NAME ORNT

DESIGN STANDARD COMPLY WITH EN81 AND MALAYSIA FMA ACT

QUANTITY 1 SETS ; SIMPLEX CONTROL

CAPACITY 544KG / 8 PERSON

SPEED 60 MPM

NO.OF STOPS 6 STOPS

NO.OF NON-STOPS NIL

NO. OF OPENING 6

TRAVEL Approx. 18,500 MM

CONTROL AC VARIABLE VOLTAGE, VARABLE FREQUENCY (AC VVVF)

OPERATION SIMPLEX COLLECTIVE AND SELECTIVE CONTROLL

POWER REQUIPMENT 3 PHASE AC 415V , 50 Hz

STRUCTURE

TOTAL HEIGHT Appox. 25,000 MM

HOISWAY SIZE 1850W x 1700D (MM)

OVERHEAD 4,800MM UP TO SOFTIT OF MACHINE ROOM FLOOR SLAB

PIT DEPTH 1650MM

Authorise Distributor:
CASA MAYA SDN. BHD.(985422-X)(GST ID NO.: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

MACHINE ROOM MACHINE ROOM TYPE

MOTOR POSITION ABOVE HOISTWAY

2:1
TRACTION RATIO

CAR ENCLOSURE

INTERAL PATFORM SIZE Approx : 1400W x 1050D x 2300H

DOOR MATERIAL Stainless Steel Hairline

DOOR TYPE 2 – PANEL CENTER OPENING

DOOR SIZE 800W x 2100H (MM)

WALL MATERIAL : SIDE Stainless Steel Hairline

: REAR Stainless Steel Hairline


Stainless Steel Hairline
: FRONT RETURN
Stainless Steel Hairline
SKRTINGS

CEILING & ILLUMINATION FACTORY STADARD SUSPENDED CEILING

CAR VENTILATION ELECTRICA LINE FLOW FAN

FLOORING By Others

CAR DOOR SAFETY EDGE ELECTRONIC PHOTO BEAM SENSOR

LANDING ENTRANCE

DOOR MATERIAL : MAIN


Stainless Steel Hairline
FLOOR

: TYPICAL FLOOR Stainless Steel Hairline

DOOR TYPE 2 – PANEL CENTER OPENING

DOOR SIZE W 800 X H2100 MM

JAMB MATERIAL : MAIN


Stainless Steel Hairline
FLOOR

Authorise Distributor:
CASA MAYA SDN. BHD.(985422-X)(GST ID NO.: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

: TYPICAL FLOOR Stainless Steel Hairline

JAMB TYPE : MAIN FLOOR NARROW JAMB

:TYPICAL FLOOR NARROW JAMB

: TOP FLOOR NARROW JAMB WITH CONTROL PANEL

OPERATION AND SIGNAL FIXTURES


CAR SIDE
OPERATION PANEL
COP1030- STD
BOARD
CAR OPERATION
INCOPORATED IN COP
INDICATOR
DIRECTION ARROW
INCORATED AT THE TOP OF THE OPERATION PANEL BOARD
INDICATOR
MICRO STOKE PUCH BUTTON WITH FLOOR NUMBERING :-, G, 1,2,3,4,5 DOOR
BUTTON
OPEN, DOOR CLOSE, ALARM BELL AND DOOR OPEN CLOSE DELAY

HALL SIDE

HALL BUTTON STATION EH1030

HALL POSITION
DOT MATRIX
INDICATOR

MAIN FLOOR EH1030

TYPICAL FLOOR EH1030

DIRECTION ARROW
IN CORPORATED IN THE HALL POSITION INDICATOR PANEL
INDICATOR

OTHER STADARD FIXTURES

AUTOMATIC TURN OFF CONTROL PANEL WILL BE TURN OFF AUTOMATICALLY IN CASE 3 MINUTE
CONTROL PANEL THERE IS NO HALL CALL OR CAR TO SAVE ENERGY
AUTOMATIC TURN OFF LIFT CAR FAN WILL BE TURN OFF AUTOMATICALLY IN CASE 3 MINUTE
FAN THERE IS NO HALL CALL OR CAR TO SAVE ENERGY
AUTOMATIC TURN OFF LIFT CAR LIGHT WILL BE TURN OFF AUTOMATICALLY IN CASE 3 MINUTE
LIGHT THERE IS NO HALL CALL OR CAR TO SAVE ENERGY
WHEN THE CAR COMPLETES THE LAST UPWARD OR DOWNWARD
WRONG DIRECTION CAR
DIRECTION CHANGE, THE SYSTEM WILL AUTOMATICALLY DETECT AND
CALL BACK CANCELLING
CANCELL THE WRONG DIRECTION CALL STILL STOREDIN THE MEMORY.
WHEN THE LIFT DETECTS THAT MORE CAR CALL HAVE BEEN REGISTERED
ANTI-NUISANCE THAT THE MEASURED WEIGHT IN THE CAR THE CONTROL PANEL WILL
CANCELL THE CAR CALLS

Authorise Distributor:
CASA MAYA SDN. BHD.(985422-X)(GST ID NO.: 001618182144)
B-G-12 Red Ruby Shop Apartment Jalan Indah 2/12 Taman Universiti Indah 43300 Seri Kembangan Selangor
Tel: +603-8938 2780Fax:+603-8958 1526 E-mail: casamayasb@gmail.comWebsite:www.casamaya.com.my

Our ref: CSMY/CMW/QUO/1512-319 Date : 15th December 2015

ARD / UPS (NOT WHEN TNB POWER FAILURE, ARD/UPS WILL IMMEDIATE GENERATE
NCLUDED) POWER SUPPLY FOR RELEVEL THE LIFT AT NEAREST FLOOR
3 WAY INTERCOM SYSTEM LIFT CAR TO LIFT CONTROL PANEL TO GROUND
INTERCOM SYSTEM
FLOOR LIFT LOBBY

Authorise Distributor: