Professional Documents
Culture Documents
Technical Site Survey Report For Site Sharing (LTE) : 1. Information of Candidates
Technical Site Survey Report For Site Sharing (LTE) : 1. Information of Candidates
Technical Site Survey Report For Site Sharing (LTE) : 1. Information of Candidates
Sharing (LTE)
Site ID Site Name Candidate City/Province Customer PO
1. Information of Candidates
1 0 Accept
1.3. Rejected Sites List : (All list site identified by radio planning for which a SAR was not turned in)
1
Technical Site Survey Report For Site
Sharing (LTE)
2. General Existing Site Sharing information
GPS Coordinates:
Candidate Address: Medan, Sei Putih Tim. II, Kec. Medan Petisah, Kota Medan, Sumatera Utara 20114
Yes No
No 0 Length : 0 Width : 0
Sector 1 pemukiman.gedung.jalan
Sector 2 pemukiman.gedung.jalan
Sector 3 pemukiman.gedung.jalan.pohon
Technical Site Survey Report For Site
Sharing (LTE)
3. Radio Network Planning
Radio Requirement
Support/pole no. A B C A B C A B C
Number of antennas 1 1 1 1 1 1 1 1 1
Antenna Size (HxWxD ) 1870x320x80 1870x320x80 1870x320x80 1870x320x80 1870x320x80 1870x320x80 1870x320x80 1870x320x80 1870x320x80
Antenna beam width ( 65
65 65 65 65 65 65 65 65
horizontal )
Antenna Gain (dBi) 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5
Antenna Frequency 1710-2170 1710-2170 1710-2170 1710-2170 1710-2170 1710-2170 1710-2170 1710 - 2170 1710 - 2170
Antenna Height 20 20 20 20 20 20 20 20 20
Total Tilting 4 4 4 4 4 4 4 4 4
Feeder size/type (i.e. 7/8; 1 ; Feederless
Feederless Feederless Feederless Feederless Feederless Feederless Feederless Feederless
etc):
Feeder length/ Feeder less 50m 50m 50m 50m 50m 50m 50m 50m 50m
Technical Site Survey Report For Site
Sharing (LTE)
4. Existing Antenna (if available)
H3I CMA-B/6621/E02 30 21 A
1 TOWER 15 42
Technical Site Survey Report For Site
Sharing (LTE)
Note: Photo documentation should include but not limited to the following:
a. Actual proposed site status
b. Panoramic Photos.
c. Access information from the nearest road going to the actual site. Include information on the narrowest access
d. Power source. Including photo of the 3 Phase power source (i.e. 3 phase PLN pole) and nearest Transformer
e. Cable tray route and grounding route; including power route going to source
f. Incase there is need to demolish existing structure, photo of which should also be presented
0 30
60 90
120 150
180 210
240 270
300 330
Technical Site Survey Report For Site
Sharing (LTE)
Actual Proposed Site Status
Tower and All Existing Antenna (View A) Tower and All Existing Antenna (View B)
Tower and All Existing Antenna (View C) Tower and All Existing Antenna (View D)
Technical Site Survey Report For Site
Sharing (LTE)
8. COVERAGE PLOT
Horisontal cable tray and route available to Vertical cable tray and route available to
install: install: Other comments: 0
Yes Yes
Technical Site Survey Report For Site
Sharing (LTE)
12. Power Supply
Installation of aerial cable Yes No Additional poles required to reach the 3 phase supply: 0
allowed:
Power cable required to be installed Length of required underground installation : Ground condition where cables will pass:
underground:
No 0 Concrete
Others: 0
Distance from the nearest 0 Capacity of the PLN 0 Number of poles 0
transformer: Transformer: required:
Any private property which will be affected by pole location and Right of way for the PLN connection: Yes No
Length of power cable from the source to
Type of supply available: Spare breakers available for use: our proposed sub-meter:
single phase 0
0
Connect to Building: three phase
Supply permanent Distance of the proposed location from site: Soundproof required: Available space
Generator:
0 Yes No Rooftop
others 0
b. Complete proposed layout (tower/pole position/equipment/ACPDB/cable route,existing PLN/transformer pole etc. with all
dimensions including set back from property line on all sides)
c. Reflect any overhead/underground utilities crossing the site (powerline, telephone line, pipesetc.)
e. Reflect any high tension Cables running outside the building which can affect delivery (approx. height)
f. Sketch the proposed route for power connection; specify the distances as stated in above data
g. SITE CONTOUR / ELEVATION (reflect approximate contour of site/elevation view; provide the elevation reading per 3m)
Site Layout
Tower Layout
Proposed Equipment (on foundation) Proposed horizontal tray
Proposed Vertical Tray (ground to top) Proposed Vertical Tray (top to ground)
Existing Equipment
Type BTS TYPE Note B Type IP MW BSC RNC METRO E SDH Backbone Other
FMR/WRFU FMR/WRFU 0 0 0 0 0 0
Existing Rectifier
Current Capacity Quantity of Module Space for new Module Remark ( recti cover
Rectifier Brand Type of Module
Module (A) (pcs) of equipment)
1 Huawei 60 3 EPW30-48A 0 0
1 DELTA 60 2 0 4 RECTY OF
Existing Battery
Number of bank Quantity of Battery Capacity of Battery
Brand Space for new Battery Remark Rectifier
Battery(Pcs) (Pcs) (AH)
BATTERAY NOT
0 0 0 0 0 0
OPEN
Existing Rectifier Existing Battery
Technical Site Survey Report For Site
Sharing (LTE)
17. Existing Power
Power PLN
PLN Capacity Phase-R A (AC) Phase-S A (AC) Phase-T A (AC) Trafo Capacity Jarak trafo ke site Genset (kVA)
Phase R Phase S
Phase T Trafo
Genset Others
Technical Site Survey Report For Site
Sharing (LTE)
18. Far End Sites
Yes No
Undang Gani
Review Date
27-Aug-2020
Approval Date
Approval Comments