5/2 Pilot Operated, Single/ Double Solenoid, Subbase Mounted Valve
5/2 Pilot Operated, Single/ Double Solenoid, Subbase Mounted Valve
WETTED PARTS
Code B1 B5
Body Anodized Anodized SS 316
Aluminium Aluminium
Internals Aluminium, SS 316 SS 316
Brass and SS 316
Guide Assembly SS 304
Shadow-Ring Copper/ Silver/ None
Plunger, Insert SS 430
Spring/ Circlip SS 302/ Steel
Fasteners SS 304
Seat, Seals NBR, Viton, F. Silicon SPARES (Refer page 25 for ordering code)
Do not specify code if opted for. Refer Page 22 for Value of
SPARE KIT CODE
AMBIENT AND FLUID TEMPERATURE Seal Kit : Oring Set and Plunger Assembly 98
Repair Kit : Oring Set, Plunger Assembly,
-30 °C to 75 °C 99
Fastener, Springs, Manual Override,
Guide Assembly, Piston Kit
SPECIAL VERSION AND SUFFIX
Solenoid Kit : Solenoid, Gasket and Nut 34
Suffix :(Valve) OX, AM
Special version : (Solenoid) CO, FR, SS, LC, III
MEDIA APPROVAL
TYPE 4X, 6P
APPLICATION
DGMS
CCOE
IP67
IP66
IP67
PORT CONNECTION
UL *
EXHAUST
EXHAUST
EXHAUST
OUTLET
OUTLET
PILOT
INLET
1 2 4 3 5 6
Contact Rotex for
• Any other ambient, fluid temperature, media and application
• UL listed, C UL Listed general purpose Valve
R
The pressure drop at inlet port causes malfunction of the Valve. All equipment connected the header and the inlet port should
have a higher orifice compared to the solenoid Valve.
Select Manifold MF003/ MF004/ MF010/ MF013
Electrical failure Stayput, Air failure to reset. Applicable for 57424.
197
Specifications are subject to change without notice 7
5/2 PILOT OPERATED, SINGLE/ DOUBLE SOLENOID, SUBBASE MOUNTED VALVE
9 SPECIFICATION
PRE- SOLENOID ENCLOSURE
(LPM OF WATER @ 1 bar ΔP)
PORT BODY MATERIAL MANUAL POWER
SSURE SEALS EXPLOSION SUFFIX
REFERENCE NUMBER
CONNECTION AND INTERNALS OVERRIDE WEATHER VA
PILOT PRESSURE
bar PROOF PROOF
FLOW FACTOR kv
CONSTRUCTION
ORIFICE (mm)
VALVE TYPE
LARGE ENCLOSURE
TERMINAL BOX IP67
SQ. PLUG IN, IP67
EXPLOSION PROOF
ALUMINIUM + SS
SOLENOID SIZE
STAYPUT CUM
FLYING LEAD
MOMENTARY
AC HOLDING
ALUMINIUM
AC INRUSH
SS 316/ CF8
MAXIMUM
MINIMUM
OXYGEN
F. Silicon
HYTREL
AMONIA
BRASS
BSP(F)
NPT(F)
EPDM
IIC, IP67
Viton
SIZE
NBR
NIL
DC
5/2 SINGLE SOLENOID VALVE
SB
2 10 6 12 51400 B5 S2 S19 M0 M8 22 25 T E III 14 18 12 8 720
Cable Entry T E = Do not specify when opted for. Refer Page 22 for Value of
Ex d Ex ia Ex emb
= Options available
M20 x 1.5 19 39 87MS 66MS 58MS 58LTMS
M25 x 1.5 87 66 58 58LT
1/2” NPT 16 37 87NS 66NS 58NS 58LTNS
6 6
SOC. HD. SCREW
M20 x 1.5
C’BORE FOR M6
1/2” NPT
SOC. HD. SCREW
C’BORE FOR M6
N
145
145
K K
3 2 4
6
2 4
6
3
10
25
10
5
25
1
1 5
50 34 50 34
63 63
75 75
PLUG IN SOLENOID TYPE 22/ 25 TERMINAL BOX/ Ex d LARGE ENCLOSURE, TYPE 16, 19, 37, 39, 5 , 5 LT
198
Specifications are subject to change without notice
4
5/2 PILOT OPERATED, SINGLE/ DOUBLE SOLENOID, SUBBASE MOUNTED VALVE
53
53
N
N
M20 x 1.5 240
1/2” NPT
240
3
3
38
7
38
75
63
7
75
63
1
1
4
66
97
5
21
5
21
DP E DT E
6 6
M20 x 1.5
1/2” NPT
N
C’BORE FOR ‘J’ SOC.
3 3
HD. SCREW
HD. SCREW
2 1 4 2 1 4
H
5 5
A G A G
F F
B B
PLUG IN SOLENOID TYPE 22/ 25 TERMINAL BOX/ Ex d LARGE ENCLOSURE, TYPE 16, 19, 37, 39
NW K A B C DP DT E F G H J G H J CONST.
(PORT SIZE) REF.
VALVE TYPE : 51404
10 SUBBASE 61 122 171 66 97 30.5 95 61 35.5 M6 36 72 15 722
DP E DT E
M20 x 1.5
6 6
1/2” NPT
C’BORE FOR
C
C
3 J 3 J
M
M
M
M
2 1 4 2 1 4
G
G
5 5
A L A L
F F
B B
F
PLUG IN SOLENOID TYPE 22/ 25 TERMINAL BOX/ Ex d LARGE ENCLOSURE, TYPE 16, 19, 37, 39
NW K A B C DP DT E F G H J L M CONST.
(PORT SIZE) REF.
THIS MODEL IS DISCONTINUED.
VALVE TYPE : 57424
10 SUBBASE 61 122 171 66 97 30.5 95 35.5 M6 36 72 15 725
CONTACT ROTEX
10 SUBBASE 81 165 201 66 97 40.5 145IF MUST
47.5 TO21OFFER
M8 52 104 726 SPECIFIC MODEL.
25 SUBBASE 81 165 210 66 97 40.5 145 57.5 M8 68 130 21 727
ADOPTER PLATE Adopter plate is used for mounting 1 No. 51404 valve.
This has individual inlet, outlet and exhaust ports.
Pilot connection can be provided on the adopter plate
A
MODEL PORT SIZE L W H A
AP4A 1/4” 122 50 32 95
AP4B 3/8” 122 60 36 95
AP4C 1/2” 165 80 40 145
W