CLC

You might also like

Download as pdf
Download as pdf
You are on page 1of 3
an52016 (Charges & Penalies - Tenaga Nasional Berhad # Typical load factor CUSTOMER TYPE [Typical Load Factor] Residential premises 035" Residential premises 0.44" Single shift| 0.15 - 0.25 industries|Double shift] 0.40 - 0.60 Triple shit] 0.60- 0.95 Deposit Payment Method For deposits less than RM2,000, customers are required to pay in cash. For deposits more than RM2,000, a bank guarantee is preferred. x Connected Load Charge (CLC) Connected Load Charge is a mitigating tools to discourage consumers from over declaring their load requirement. READ MORE CONNECTED LOAD CHARGE (CLC) + Connected Load Charge is a mitigating tool to discourage consumers from over declaring their load requirement. Over declaration will lead to over plant up and waste of resources and increase in reserve margin. Without CLC, other consumers have to also pay for the unnecessary higher cost of electricity due to wastage and this is unfair to those who properly declare. * Other utility who does not have CLC penalty, recover their demand component or fix cost via imposing contract capacity charge through their tariff rate based on consumer declaration. Affected customers + All new medium voltage and high voltage consumers (consumers with supply voltage at 6.6kV and above) are subjected to CLC for a period of 6 years from the date the supply was commissioned with CLC exemption for the first year only. + orany supply and/or load and/or voltage upgrade, the consumer will be levied new CLC based on the total maximum demand declared (i.e current maximum demand plus additional maximum demand). CLC calculation * CLC is applicable when the actual Maximum Demand (MD) recorded on any month is less than 75% of the declared maximum demand during the said period. a= * CLC is imposed based on the shortfall between the 75% of the declared maximum demand and maximum demand recorded in a month. CLC rate charges are RM8.50 per kilowatt and subjected to prevailing changes from time to time. bitpezwatnb com mylcommercia-Indusrillchargee-ponatos as016 (Charges Perales - Tenaga Nasional Berhad + Nevertheless, for the first 3 years, the CLC will be based on staggered percentage to assist consumer during the initial stage of their operation. * The method in determining Reference Maximum Demand? for calculating CLC are as follows: Year Reference Maximum Demand* vedo 1 0%x 75% x Declared Maximum Demand(CLC exempted for the first year only) "7 o 30% x 75% x [Declared MD or Highest Recorded MD, whichever is higher] ae ee #e 2 375% x 75% x (Declared MD or Highest Recorded MD, whichever is higher] $7 5' td 4 100% x 75% x [Declared MD or Highest Recorded MD, whichever is higher] 7 a ade 5 100% x 75% x [Declared MD or Highest Recorded MD, whichever is higher 2 30 iene 6 100% x 75% x Declared MD or Highest Recorded MD, whichever is higher] {7450 lyons Note: CLC is applicable when MD recorded < Reference MD. wn + A penalty of RM8.50/kW will be charged for every kW shortfall between the Actual Maximum Demand used compared to the Reference Maximum Demand (RMD). ask XPM hey a * CLC is calculated monthly. we © CLC penalty RM8.50 is well below the Maximum Demand rate... J ew 140 x» « Example of CLC calculation: he icanl gh \ wn . as : AAW ‘Maximum Demand Reference Actual Maximum Year — Declared(assume Maximum — Demand(AMD) —_CLC Penalty(RM) 10,000kW) Demand(RMD) (kw) 0% x 75% x : ; 1 10,000kW 10,000kW = OkW 100kW Not Applicable 50% x 75% x 2 10,000kW 10,000kW = 5,000kW No penalty, AMD > RMD 3,750kW 75% x 75% x CLC = RM8.50 x ( 3 10,000kW 10,000kW = 5,000kW 5,625KW - 5,000kW ) = 5,625kW RMS,312.50 100% x 75% x 4 10,000kW 10,000k 7,500kW No penalty. AMD > RMD 7,500kW . 100% x 75% x 5 10,000kW 10,000kW = 8,000kW No penalty. AMD > RMD 7,500kW 100% x 75% x 6 10,000kW 10,000kW = 8,000kW No penalty. AMD > RMD 7,500kW Few activities could be carried out by customers that assist in reducing MD charges such as: * Practicing demand side management such as peak shift ic. shifting their peak operation/consumption to off peak period as MD charges is not applicable during off-peak period for customer with peak/off- peak tariff «Opting for any promotional scheme offered by TNB relating to MD such as Sunday Tariff Rider ipssivww ib. com. myicommercia-industrelicherges-ponelties 48 D> 1, Plemtong. 8 Lines ities on Overs] Penalties: Declaration of, Demand Load KA informed that TNB will impose penzities on the consumer on under- ‘ilization of declared load demand as follows = (i) First Year ~ Zero penalty: @) ™ Year -335% of the differences perween the declared demand and |" the actual power consumption: Bolle Hk (@) 3" Year ~5625% of the differendes bem eep ‘the declared demand ‘and the actual power consumption; Cas, x 48%) (4) 4, 5® and 6" Year ~ 75% of the differences berween the declared emuand and the actual power consumption; ( 100 4. 8D) (5) 7? Year and onward — No mare penalty ‘The rate of charge Will be RM8.5 per EW per month on the difference.

You might also like