MODEL: MLG
OPERATION PRINCIPLE
A vertical measuring chamber (1) is connected to the liquid vessel at each end (Side to Side,
Top to Side, Side to Bottom & Top to Bottom) contains a Float (2) with a built-in permanent
magnet (3) inside that rises and falls with the liquid level. The chamber is completely sealed
so that the only moving part that contacts the liquid is the FLOAT itself.
On the “Dry Side” of the chamber, a Magnetic strip Indicator (4), a
column of bi-color magnetic tabs (5) that form a vertical strip to
provide a visual indication of the fluid level attached.
As the float moves up or down, the permanent magnet mounted in its
top section of float “pulls” the tabs through a rotation of 180 Deg,
thus changing their color.
As the float rises the tabs are turned from white to red and as the
float falls, they changed back to white again.
This means that the liquid level inside the vessel is constantly
represented by a Red strips without use any external power supply.
The Magnetic level gauge, MLG can be attached with:
- MAGNETIC SWITCH
- LEVEL SENSORS & TRANSMITTER
MAGNETIC LEVEL GAUGE – MODEL: MLG-S
Technical Data
• Pipe Chamber : 2” Sch 10
• Chamber End Top :
- Welding Flat Top with vent plug, M10
• Chamber End Bottom:
- Flange with Drain Plug, M10 or ½” NPT
• Process Connection :
- Flange, ½” to 2” (JIS, DIN or ANSI)
- Screw, ½”to 1”, NPT or BSP
• Mounting : Please see page 8
• Length : 6000mm & 15,000mm (Special)
• Material : SS304 or SS316
• Pressure Maximum : 16 Bar
- Higher Pressure on request
•Temperature Maximum :
- 150 °C (Std), 200 °C & 400 ° C (Special)
• Float : See page 5
• Options:
• Magnetic Switch
• Level Sensor & Transmitter,4-20 Ma
• Drain Valve and Cm Scale
TYPICAL APPLICATION
FLOATS DATA AND SPECIFICATION
HOUSING:
• Aluminium anodized
• SS304 - Optional
MAGNETIC INDICATOR:
• Plastic Flap (FP-1 & FP-2)
• Ceramic Roller (CR)
COLOURS:
• Red / White
COVER:
• Polycarbonated
• Glass
TEMPERATURE MAX:
• FP-1 (150 °C) & FP-2 (200 °C)
• CR (400 °C)
PROTECTION RATING:
• IP-65
OPTIONAL:
• Cm Scale
MAGNETIC SWITCH
Magnetic Switch MS-1 is a Magnetic Switch that mounted at the side of the MLG ,Magnetic Level
Gauge. The Magnetic switch MS-1 that together with MLG Level Gauge can be used for control
pumps in Emptying or Filling process as well as monitoring of High and Low Level Alarms.
The MS-1 switch mounted at the rail of MLG magnetic Level Gauge and can be adjust at any
position by easy sliding.
Magnetic Switch, MS-1 also available in Explotion proof housing.
ORDERING CODE