Mimic Cabinet BUR-200

Autroprime Interactive Fire Detection System


Product Datasheet

Features
 Cabinet including 1 Mimic Driver BUR-200 and
16 programmable relays
 1 Mimic Driver is capable of driving 32 current
limited LEDs
 A Mimic Driver is provided with 8 standard
monitored inputs
 A maximum of 8 Mimic Drivers can be connected
to the RS-485 Panel Bus, providing a total of 256
outputs and 64 monitored inputs
 Powered by 24V DC, redundant, monitored
 Lamptest
 LED intensity control
 Designed to meet EN 54 and SOLAS
requirements, and conforms to CE standards

Application/Description
The Mimic Cabinet BUR-200 is specifically designed
for use in maritime applications. It consists of 1
Mimic Driver BUR-200 and 16 programmable relays.
Technical specifications
One Mimic Driver that is capable of driving 32 LEDs
with series resistors on a mimic panel for additional Dimensions (mm) 420 x 346 x 140
indication of alarms. In addition, 8 standard Weight (g) 8,0 kg
monitored inputs can be used for reading various Materials Steel cabinet
switches. Protection class IEC-529 / IP30
Operating -15oC to +70oC
The Mimic Driver is connected to the RS-485 Panel Temperature
Bus (see drawing on next page).
Storage -40oC to +70oC
Temperature
Power redundancy is achieved by using a daisy-
chain connection with master and slave drivers. Humidity 0 to 95% non-condensing
Power supply 24VDC (18-32V)
For detailed information on the Mimic Driver, refer to Current Maximum 25mA
separate datasheet for BUR-200. consumption
Total load BUR-200 Maximum 500mA
Communication RS-485 panel bus

Part number Description


116-71211551 BUR-200 Mimic Cabinet
BUR-200 Mimic Cabinet is delivered with the following
relays:
116-7624-030.0002 Relay PLC-RSC-24DC/21-21
116-7624-030.0001 Relay PLC-RSC-24DC/21

116-P-BUR200CABINET/CGB, Rev. C, 2010-09-22 Protecting life, environment and property…


Mimic Cabinet BUR-200

Schematics
Note:
2k Ohm resistors must be installed on the monitored
inputs J13 and J14. A jumper must be installed
between J12-1 and J12-2.

J13 J15 J16 J17 J18 J19


Inp. 1+
Inp. 1-
Inp. 2+
Inp. 2-
Inp. 3+
Inp. 3-
Inp. 4+
Inp. 4-

Manual
See

Out 32
Out 31
Out 30
Out 29
Out 28
Out 27
Out 26
Out 25

Out 24
Out 23
Out 22
Out 21
Out 20
Out 19
Out 18
Out 17

Out 16
Out 15
Out 14
Out 13
Out 12
Out 11
Out 10
Out 9

Out 8
Out 7
Out 6
Out 5
Out 4
Out 3
Out 2
Out 1
1
2
3
4
5
6
7
8

1
2
3
4
5
6

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8
Inp. 5+
Inp. 5-
Inp. 6+
Inp. 6-
Inp. 7+
Inp. 7-
Inp. 8+
Inp. 8-

Manual
See

+
+
+
+
+
+
+
+

+
+
+
+
+
+
+
+

+
+
+
+
+
+
+
+

+
+
+
+
+
+
+
+
1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8

1
2
3
4
5
6
7

J14 J12 J20 J21 J22 J23

K-16 K-15 K-14 K-13 K-12 K-11 K-10 K-9 K-8 K-7 K-6 K-5 K-4 K-3 K-2 K-1

Panel Bus Connection


The drawing below shows an example of a panel
bus interconnecting a BUR-200 Mimic Driver, a Fire
Alarm Control Panel BS-200M, a Repeater Panel
BS-211, and an Information Panel BV-210.

AUTRONICA FIRE AND SECURITY AS


Head office, Trondheim, Norway Tel: +47 73 58 25 00, fax: +47 73 58 25 01, e-mail: info@autronicafire.no
Oil and Gas division, Stavanger, Norway Tel: +47 51 84 09 00, fax: +47 51 84 09 99
Maritime division, Spikkestad, Norway Tel: +47 31 29 55 00, fax: +47 31 29 55 01

Visit Autronica Fire and Security AS’ website: www.autronicafire.com

You might also like