Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 7

Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

Configuration RBS 6102 (Outdoor Cabinet)

1st Types of RUS.

According Bands.

RUS B8 for Band 900 (Site).

RUS B3 for Band 1800 (CO).

According No. Of Carrier .

RUS 01 Max No. Of carrier (4 TX).

RUS 02 Max No. Of carrier (8 TX).

For Example if you find RUS B3 02 its mean you have RUS for Band ( 1800 )and and Max
no. of carrier (8TX) .

Note :
For each DUG (Max No. of Carrier 12 TXRX).

2ND Configuration By Using OMT.

1-Open OMT
Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

2-Chose Create IDB

3-Chose Cabinet type as shown on P.S

Then ok
Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

4-Chose Antenna Sector type (According your configuration chose No. of sector then from
lower bottom determine no. Of RUS)
Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

5-Node Parameter for 1st DUG must be Master and Its node will be True as shown
In P.S

And Add EXT Node False and determine its position form SCU (A5 .A6,A7,A8
….. )
Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

6- Cabinet Layout

1st Chose RUS Position and determine Position of Each element at cabinet as shown In
PS.
Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

7-Ext Alarms .

1st smoke detector chose transmission then defined then chose SCU for three position all for
EXT Alarm.

2nd climate and Door chose SAU as shown in PS


Mohamed Abd EL-Rhman Site Engineer (HOI-MEA)

For IP Ran Change Type of Transmission in each DUG as Shown In P.S