Professional Documents
Culture Documents
Project 171 - Curtain Wall - Special Bottom Bracket (For W-25-C)
Project 171 - Curtain Wall - Special Bottom Bracket (For W-25-C)
74
www.hilti.com
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Special Bottom Bracket (For W-25-C) Date: 1/4/2022
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HUS-HR M14x80
Item number: 290181 HUS-HR 14x80 10/-
Effective embedment depth: hef = 52.1 mm, hnom = 69.8 mm
Material: A4
Evaluation Service Report: Hilti Technical Data
Issued I Valid: -|-
Proof: Design Method ACI 318 / AC193
Stand-off installation: eb = 0.0 mm (no stand-off); t = 6.0 mm
Anchor plate :
R lx x ly x t = 130.0 mm x 55.0 mm x 6.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 500.0 mm
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Seismic loads (cat. C, D, E, or F) no
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.74
www.hilti.com
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Special Bottom Bracket (For W-25-C) Date: 1/4/2022
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nua [kN] Capacity f Nn [kN] Utilization bN = Nua/f Nn Status
Steel Strength* 1.378 64.188 3 OK
Pullout Strength* 1.378 8.703 16 OK
Concrete Breakout Failure** 1.378 8.911 16 OK
ANc [mm ]
2
ANc0 [mm ]
2
ca,min [mm] cac [mm] y c,N
24,402 24,402 87.0 93.7 1.000
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.74
www.hilti.com
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Special Bottom Bracket (For W-25-C) Date: 1/4/2022
Fastening point:
4 Shear load
Load Vua [kN] Capacity f Vn [kN] Utilization bV = Vua/f Vn Status
Steel Strength* 0.309 24.888 2 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 0.618 11.557 6 OK
Concrete edge failure in direction x-** 0.618 4.307 15 OK
ANc [mm ]
2
ANc0 [mm ]
2
ca,min [mm] kcp cac [mm] y c,N
30,946 24,402 65.0 1 93.7 1.000
z z
bNV = bN + bV <= 1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.74
www.hilti.com
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Special Bottom Bracket (For W-25-C) Date: 1/4/2022
Fastening point:
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the
potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or
where pullout or pryout strength governs.
• Refer to the manufacturer's product literature for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to
https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.74
www.hilti.com
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Special Bottom Bracket (For W-25-C) Date: 1/4/2022
Fastening point:
7 Installation data
Anchor type and diameter: HUS-HR M14x80
Profile: no profile Item number: 290181 HUS-HR 14x80 10/-
Hole diameter in the fixture: df = 17.5 mm Maximum installation torque: 0.000 kNm
Plate thickness (input): 6.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 79.4 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 139.7 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.
Hilti HUS screw anchor with 69.85 mm embedment, M14x80, Stainless steel, installation per instruction for use
y
65.0 65.0
27.5
27.5
1 2
-0.0
x
27.5
27.5
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.74
www.hilti.com
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Special Bottom Bracket (For W-25-C) Date: 1/4/2022
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!